Sit La Precisa S p A FRC584001 FRC 584 User Manual Manual 1

S.I.T. La Precisa S.P.A. FRC 584 Manual 1

manual

Download: Sit La Precisa S p A FRC584001 FRC 584 User Manual Manual 1
Mirror Download [FCC.gov]Sit La Precisa S p A FRC584001 FRC 584 User Manual Manual 1
Document ID259752
Application IDG+fyl6a6ULXTTArgDXhxcA==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize60.58kB (757243 bits)
Date Submitted2002-07-30 00:00:00
Date Available2002-07-30 00:00:00
Creation Date2002-06-17 15:25:35
Producing SoftwareAcrobat PDFWriter4.0 per Windows
Document Lastmod0000-00-00 00:00:00
Document TitleManual-1.PDF
Document CreatorMicrosoft Word
Document Author: pirgia

584 FRC
ENGLISH
Read the instructions before use. This control must be installed in accordance with the rules in force.
FCC NOTICE
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in
a residential installation.
This equipment generates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, these is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by tuning the equipment off and on, the
user is encouraged to try to correct the interference by one or more the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
n FRC 584.0xx
Transmitter RF Control for 820 NOVA Millivolt System
FRC is the new SIT RF Control for a Millivolt System to be used togheter with the SIT 820
NOVA mV system equipped with the 584.101 or 584.201 receiver.
With the FRC you can turn your gas fireplace on or off; use a timer to shut down the
fireplace automatically at the desired time, increase or decrease flame height, set the fan
speed and other useful functions.
Three pre-progammed flame time profiles are avilable.
A wide clear display gives you many information as room temperature, set temperature,
flame height, fan speed level, timer condition, as well as a low battery indication.
This Owner’s Guide describes in details how to use in the best way this product.
1. General description of the remote control
The surfing between the various options is achieved by functions sliding.
With reference to the four keys displaced in around, the upper and lower keys (functions
sliding) allow the selection of the functions available in the remote control, while the left
and right keys (decrement and increment of the set points) allow to modify the working
levels/states of the selected function.
The device will transmit when a key is pressed and the transmission time will not be
longer than 1 second even if the key is maintained pressed.
Upper function sliding
(PREVIOUS STEP key)
Set point decrement
(DOWN key)
Set point increment
(UP key)
ON/OFF key
Lower function sliding
(NEXT STEP key)
At the start-up the device sets itself for the flame height
control.
The available functions are:
Flame height control
Program selection (only with 0584101 receiver)
Room thermostat
Fan speed selection (only with 0584101 receiver)
Timer
AUX output opening or closing (this function must be
operated only by qualified personnel)
Insert three 1.5V AAA style batteries in the remote control.
Do not reverse the polarity of the batteries.
Display indications
2. System start-up
4.1
Preliminary check of the receiver
Operations to be done on the receiver, before
switching on the remote control:
1) With the 0.584.201 battery powered receiver,
insert the batteries (4 x 1.5V AA style) in the
proper hollow and wait for the generation of the
beep”) as a confirmation that
the receiver is working.
With the 0.584.101 line powered receiver,
connect the power soket to the power plug of
the receiver and wait for the generation of the
acoustic signal (“beep”) as a confirmation that
the receiver is working.
2) Set the MAN/AUTO switch in the AUTO position (to the left) to let the remote control
operate the gas valve.
Note all the above operations can be done without turning on the pilot flame in the
fireplace.
4.2
Check of the functionality of the remote control
The remote control can work only if properly powered.
The power is supplied by 3 1.5V AAA style batteries to
be inserted in the proper hollow with the correct
polarity.
The correct power of the remote control can be checked
observing the presence of the icon “little house” with at
its side the measurement of the room temperature. This
indication will be always presente when power is applied
to the remote control.
When the ON/OFF key is pressed, after a short time you
can seen may other icons on the LCD display. This
indicates that the remote control is “ON”.
4.3
Check of the communication between the remote control and the receiver
When the ON/OFF key is pressed to switch on the remote control the “transmission” icon
is activated to indicate the transmission of a command to the receiver.
At the same time an acoustic signal will be generated to indicate the reception of the
command by the receiver.
If the acoustic signal isn’t generated switch the remote control OFF, take place at a lower
distance from the receiver and switch the remote control on again.
If again the acoustic signal isn’t generated, execute the address setting procedure
described in the remote control operating manual.
3. Valve operation
Start-up procedure
Set the thermostat, if present, to the lowest level.
Press slightly and turn the control knob clockwise
to the “OFF” position and wait five minutes;
thus allowing any gases to escape which
may have accumulated in the combustion chamber.
NOTE: LP gases do not vent upward.
Pilot flame ignition
Press slightly and rotate the “OFF/ PILOT/ ON”
control knob to the “PILOT” position. Press the
knob and light the pilot flame, keeping the knob
fully depressed for at least thirty (30) seconds
until air in the pilot line vents and a strong pilot
flame is present. Release the knob and verify
that the pilot flame remains lit.
Igniting the main burner
Confirm that the thermostat is closed. Turn the
“HI/LO” knob to the “LO” setting. Turn the
control knob to the “ON” position. The gas path
to the main burner is now open. The maximum
gas flow to the burner is obtained with the knob
fully turned counter-clockwise (“HI” position).
Stand-by position
To maintain a flame at the pilot burner with
the main burner off, turn the control knob to
the “PILOT” position.
Turning off
Turn the control knob to the “OFF” position.
Caution: After shutting down, wait at least five minutes before re-igniting. This will
allow the safety interlock to reset.
Final checks
1. WARNING
Fire or Explosion hazard.
Can cause damage to property and severe injury or death.
Do not force the control knob. Use only your hand to turn the knob. If the knob does not
move by hand, the valve should be replaced by a trained service technician.
Shutdown performance check
2. WARNING
Fire or Explosion Hazard.
Can cause severe injury or death.
Perform the safety shutdown check any time work is done on a gas system.
1. Place appliance in operation with the pilot and main burners lit.
2. Place gas control knob in “PILOT” position. Main burner should extinguish and
pilot should remain lit.
3. Extinguish pilot flame. Pilot gas safety shutoff proves complete shutdown due to
the fact the safety shutoff valve prohibits main burner and pilot gas flow.
4. Wait at least five minutes for the safety magnet to reset and residual gas to clear
from the combustion chamber.
Relight pilot burner and operate the system through one complete cycle to ensure all
functions operate correctly.
3. Remote control operation
3.1 Manual flame height control
With this function it is possible to manually control the flame height.
To enter this function press the Previous Step or Next Step key
Previous
Next Step
until the great flame in the upper part of the display is
selected (see figure)
Then press the Up or Down key
Dow
Up
Up to the desired flame level. Six flame levels are
available, from 1 (min) to 6 (max).
3.1
Modulating flame sequence selection
WARNING: this function is available only with the 0.584.101 line powered
receiver.
With this function it is possible to select among three different flame modulation
sequences that will be executed automatically by the system.
With these programs the flame modulates between the min and max levels following the
time sequences described below:
1st sequence
sample duration 5s
livello
1.
tempo
2.
livello
2nd sequence
sample duration 5s
tempo
livello
3.
3rd sequence
sample duration 5s
tempo
6 -> max level
0 -> off
1 -> min level
To enter this function press the Next Step or Previous Step key
Previous
Next Step
until the flame sequence function is selected (note the
small arrow to the left)
then press the Up or Down key
Dow
to select the desired program.
Up
3.2
Room thermostat function
With this function it is possible to transform your remote control in a room thermostat to
control the room temperature.
To enter this function press the Next Step or Previous Step key
Previous
Next Step
Until the room thermostat function is selected.
then, use the Up or Down key
Dow
Up
to set the temperature to the desired value.
3.3
Fan speed setting
WARNING: this function is available only with the 0.584.101 line powered
receiver.
With this function it is possible to set the speed of the warm air fan that could be present
in the appliance. One of four speeds can be selected (4 indicates the full speed) or the fan
can be halted.
OFF
To enter this function use the Next Step or Previous Step
Previous
Next Step
and select the fan icon (note the small arrow to the left)
then use the Up or Down key
Dow
to set the desired fan speed.
Up
3.4
Timer setting (sleep function)
WARNING: this function is available only with the 0.584.101 line powered
receiver.
With this function it is possible to set a sleep time. After the sleep time has elapsed
the appliance is automatically switched off.
The maximum sleep time is 90 minutes
To enter this function use the Next Step or Previous Step key
Previous
Next Step
and select the sleep timer function
then use the Up or Down key
Dow
Up
to set the desired sleep time; then use again the
Next Step or Previous Step key to exit the function and
start the downcount.
The sleep time step is 15 minutes.
3.5
Auxiliary output control (AUX)
WARNING: this function is available only with the 0.584.101 line powered
receiver
With this function it is possible to activate (close) or deactivate (open) the electric contact
present in teh receiver. The function is active when the “AUX ON” indication appears. On
the contrary, the function is not active when “AUX OFF” indication appears.
To enter this function use the Next Step or Previous Step key
Previous
Next Step
and select the AUX function icon (not the small arrow to
the left).
Then use the Up or Down key to turn the function ON or
OFF.
3.7 Safe Child function
With this function it is possible to deactivate the remote
control keys. The function is active when the lock icon is lit
(see figure).
To activate this function press the ON-OFF key and after 1 sec the Next Step key, then
releas first the ON-OFF key and then the Next Step key.
Operate the same sequence to deactivate the function.
Next Step
ON-OFF
3.8
Fahrenheit – Celsius temperature indication
To choose the measurement unit for the temperature use the Next Step or
Previous Step key
Previous
Next Step
and select the AUX function.
then press five times the Down
Down
3.9
Receiver search
With this function it is possible to start a receiver search sequence.
To enter this function use the Next Step or Previous Step key
Previous
Next Step
and select the AUX function
then press 5 times to start the receiver search
Up
A “ beep “ will advice you of the connection between the transmitter and the receiver.
As you hear the “beep” press the Up key to stop the search and fix the address of the
transmitter.
3. Warnings
Do not let the 584 FRC remote contraol fall.
Do not let the remote control near to heat sources (it can be dameged by high
temperatures)
Do not let the remote control unattended
The functions:
- automatic flame sequence
- fan speed setting
- AUX function
are available only with the 0.584.001 line powered receiver
Functional Drawings

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 20
Creator                         : Microsoft Word
Create Date                     : 2002:06:17 15:25:35
Title                           : Manual-1.PDF
Author                          : pirgia
Producer                        : Acrobat PDFWriter4.0 per Windows
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QFA-FRC584001

Navigation menu