Skidata EXGR400 Parking column using RFID User Manual Cover ColumnSPT400 1 0 en

Skidata AG Parking column using RFID Cover ColumnSPT400 1 0 en

User manual

Download: Skidata EXGR400 Parking column using RFID User Manual Cover ColumnSPT400 1 0 en
Mirror Download [FCC.gov]Skidata EXGR400 Parking column using RFID User Manual Cover ColumnSPT400 1 0 en
Document ID420917
Application IDcEuvBx7bk7nWpDwxeM7i0w==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize109.79kB (1372407 bits)
Date Submitted2004-05-07 00:00:00
Date Available2004-05-06 00:00:00
Creation Date2004-05-06 16:05:02
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2004-05-06 16:05:02
Document TitleCover-ColumnSPT400-1-0-en.cdr
Document CreatorPScript5.dll Version 5.2
Document Author: bebe

Parking Columns System SPT 400
Parking Column EN/EX EMPTY 400
Parking Column ENTRY LCD 400
Parking Column ENTRY GR MON 400
Parking Column EXIT LCD 400
Parking Column EXIT GR MON 400
Parking Column EN/EX EMPTY 400 - US
Parking Column ENTRY LCD 400 - US
Parking Column ENTRY GR MON 400 - US
Parking Column EXIT LCD 400 - US
Parking Column EXIT GR MON 400 - US
Manual and operational description
Manual and operational description
Version February 2004
Parking Columns System SPT 400
SKIDATA AG
Technical Documentation
Untersbergstrasse 40
A-5083 Gartenau
Telephone
+43 6246 888-0,
Telefax
+43 6246 888-7
Internet
http://www.skidata.com
e-mail
docu@skidata.com
Copyright
© 2004 by SKIDATA AG. All rights reserved. All information in the
following document is protected by copyright law. No part of this
document may be reproduced without the written consent of SKIDATA AG. SKIDATA AG reserves the right to make any changes
of specification and other information in this document without
further notice.
Please note
During the compilation of this Technical Documentation, great
care has been taken to ensure the accuracy of the information
contained in it. However, despite our constant effort to ensure the
highest degree of accuracy and comprehensiveness possible,
the information provided cannot be guaranteed to be absolutely
error-free.
Trademarks
This documentation may contain representations of registered
product or service trademarks owned by SKIDATA AG or third
parties, as well as references to proprietary know-how protected
by copyright laws or other legal provisions. In any case the intellectual property rights remain exclusively with their respective
owners.
Declaration of Conformity
The Parking Columns of System SPT 400 except the model versions where the name ends with the characters “-US” have been
developed, designed and manufactured in accordance with the
following EU directive:
R&TTE (99/5/EC)
0408
Page 2
© SKIDATA AG, February 2004
Manual and operational description
Parking Columns System SPT 400
Important : The FCC-specific notes apply only to the model versions where the name ends with the characters “-US”.
FCC 15.19:
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC 15.21:
IMPORTANT: Any changes to or modifications of Parking Columns of System SPT 400 unless expressly approved by SKIDATA AG, may void the user's authority to operate this device.
© SKIDATA AG, February 2004
Page 3
Manual and operational description
Parking Columns System SPT 400
Parking Columns System SPT 400
Document Management – Version Table
Tab. 1: Document Version Table for Installation & Maintenance Instructions
Section Document
Pages
25
Page 4
Parking Columns System SPT 400
Version
1.0
Date
2004-02-11
© SKIDATA AG, February 2004
1
Parking Column
Parking Columns
System SPT 400
Version 1.0
25 pages
Copyright 2004 by SKIDATA AG
1
1.1
Parking Column
Contents
1.1
Contents
1.1
Contents
1.2
1.2.1
1.2.2
1.2.3
1.2.4
1.2.5
Parking Column for System SPT 400
Installation
Power supply
Stripping connection wires
Cross-sectional area of cable leads
11
Connection terminals for control lead and
intercom
11
Connection loop detector
13
Connection SIO, Arcnet
14
Changing the fuse
16
Earthing connection
17
Surge protection for external devices
18
Weather protection
18
MANUAL OPEN/CLOSE switch
20
Installing devices in the front panel
21
Opening the front panel
23
Closing the Parking Column
25
1.2.6
1.2.7
1.2.8
1.2.9
1.2.10
1.2.11
1.2.12
1.2.13
1.2.14
1.2.15
Page 2
© SKIDATA AG, Version 1.0
1
Parking Column
Parking Column for System SPT 400
1.2
1.2
Parking Column for System
SPT 400
Fig. 1:
Parking Columns for System SPT
400
General Warning:
PCBs are sensitive to electrostatic discharge and should be
handled with great care to avoid damage to the circuitry.
Avoid touching the boards unnecessarily. Before mounting the
column, check the entire device for possible transport damage.
Before accessing electronical or mechanical parts, the entire
deviced must be disconnected from the mains.
© SKIDATA AG, Version 1.0
Page 3
1
1.2
Parking Column
Parking Column for System SPT 400
Ensure the following before proceeding with the installation:
„The concrete foundation must be exactly horizontal. Installing
the device on an uneven surface may cause the chassis to
become warped or damaged. If levelling of the surface is not
possible, the parking column must be level-adjusted, e.g. by
using additional hexagon nuts (see Fig. Hexagon nuts as
spacers); in that case the threaded rods must be allowed to
protrude further.
„The surface of the concrete foundation must be even and exactly horizontal
„Cable protection tubes should be cut approx. 2 cm above the
concrete surface
1.2.1
Installation
„The threaded rods should protrude approx. 50 mm from the
concrete surface
„The fastening tension of the hexagon nuts must not exceed
20 Nm
„Use washers with large outer diameter (∅ = 30 mm, as per
UN 737 standard)
„The parking column must be aligned exactly horizontally
Page 4
© SKIDATA AG, Version 1.0
1
Parking Column
Parking Column for System SPT 400
1.2
Fig. 2: Column installation
© SKIDATA AG, Version 1.0
Page 5
1
1.2
Parking Column
Parking Column for System SPT 400
Installation on non-level surfaces (applies only in exceptional circumstances)
Fig. 3:
Hexagon nuts as spacers
All three No. 2 washers must be absolutely level (use a spirit
level if necessary).
Important:
Avoid drilling dust from getting into the device during installation, as electrostatically charged dust may cause damage to
the electronic assemblies inside the column.
Page 6
© SKIDATA AG, Version 1.0
1
Parking Column
Parking Column for System SPT 400
1.2.2
1.2
Power supply
Two types of Parking Columns are available : 120 V und 230 V
Important notes:
Electric installation and maintenance work may be carried
out only by appropriately qualified, licensed electrical
technicians.
Mains connections must be hardwired.
Please ensure full compliance with all applicable national
and international rules and regulations concerning electric connections, and all applicable safety regulations.
When all electric lines are properly connected, replace and fasten
the cover.
© SKIDATA AG, Version 1.0
Page 7
1
1.2
Parking Column
Parking Column for System SPT 400
Fig. 4:
Column interior:
Mounting plate configuration
Page 8
© SKIDATA AG, Version 1.0
1
Parking Column
Parking Column for System SPT 400
1.2
Ensure the following before proceeding with electrical connections:
„Check for proper mains supply voltage (120 V or 230 VAC)
„Mains connections must comply with national standards and
guidelines
„When using flexible stranded wires, all filaments must be
placed inside the terminal clamps (use wire-end sleeves, if
necessary)
„The mains supply line must be fused in accordance with applicable regulations (6 A fuse recommended)
„Check the isolation resistance of the cables to make sure it
exceeds 0.5 MΩ
„Fix cables to mounting plate by way of tension relieve tongues
and cable ties
„Check the network cables to ensure the proper loop impedance
Important: Always make sure that the device is completely
disconnected from the mains while fitting electric wiring.
1.2.3
Stripping connection wires
To avoid danger of short circuit with wires or chassis parts, wires
should not be stripped by more than 6 mm (recommended
value). Uninsulated wire sections must be inserted completely
into the connection terminals.
When attaching connecting wires, the insulation should cover the
wire up to the point where it connects to the terminal.
Fig. 5:
Correct connector wiring
© SKIDATA AG, Version 1.0
Page 9
1
1.2
Parking Column
Parking Column for System SPT 400
Fig. 6:
Power supply on sd591
** see 1.2.4 Section Cross-sectional area of cable leads
Page 10
© SKIDATA AG, Version 1.0
1
Parking Column
1.2
Parking Column for System SPT 400
Caution:
The OUT terminal on connection control board sd591 is not
fused and cannot be deactivated by way of the on-board mains
switch.
Note:
Electrical leads and wires must comply wirth applicable national guidelines concerning
– mechanical stress
– tension resistance
– cross-sectional area with respect to voltage drop
– current carrying capacity and short-circuit rating
„To install electrical fittings, you must first remove the cover of
control board sd591
1.2.4
Cross-sectional area of cable leads
Tab. 1: Cable leads – Technical characteristics
wires
Max. torque at terminals
Rigid
Solid
Flexible
Twisted
0,22 – 0,25 Nm
0,14 – 1,5 mm²
0,14 – 1,5 mm²
**
0,5 – 0,6 Nm
0,20 – 2,5 mm²
0,20 – 2,5 mm²
***
0,22–0,25 Nm
0,14 – 1,5 mm²
0,14 – 1,0 mm²
1.2.5
© SKIDATA AG, Version 1.0
Connection terminals for control lead and
intercom
Page 11
1
1.2
Parking Column
Parking Column for System SPT 400
Fig. 7:
Connection terminals for control
lead and intercom
* see Section 1.2.4 Cross-sectional area of cable leads
Page 12
© SKIDATA AG, Version 1.0
1
Parking Column
Parking Column for System SPT 400
1.2.6
1.2
Connection loop detector
Fig. 8:
Connection terminals for loop
detector
© SKIDATA AG, Version 1.0
Page 13
1
1.2
Parking Column
Parking Column for System SPT 400
1.2.7
Connection SIO, Arcnet
Fig. 9: Connections on control board sd582
*** see Section 1.2.2 Power supply
Page 14
© SKIDATA AG, Version 1.0
1
Parking Column
Parking Column for System SPT 400
1.2
Fig. 10:
sd582 – I/O circuit connections
Note on wire twisting:
When connecting Arcnet and loop cables, make sure that the
wires are twisted up to the connection terminal (approx. 5
twists per 10 cm).
Shield connections must be as short as possible and insulated
against contact with the chassis wall by means of a protective
tube.
© SKIDATA AG, Version 1.0
Page 15
1
1.2
Parking Column
Parking Column for System SPT 400
1.2.8
Changing the fuse
Important Note:
A blown fuse indicates a device defect that requires the attention of a trained service technician. The fuse must be replaced by a new one of the same type and technical
characteristics (see below). Before replacing the fuse, the
lead in the power distributor must be deactivated (i.e., disconnected from the mains).
Fuse characteristics:
120 VAC = 5 A–T
230 VAC = 2.5 A–T
Model:
Type:
Time lag:
High breaking capacity:
Ceramic tube
Page 16
Schurter
SPT 5x20
© SKIDATA AG, Version 1.0
1
Parking Column
1.2
Parking Column for System SPT 400
1.2.9
Earthing connection
The protective earth conductor of the lead must be attached to
the central earthing point by way of a ring lug.
Fig. 11:
Earthing point
Fig. 12:
Protective earth
conductor
„After installation, ensure proper metal contact of all aluminium
parts, i.e. the cable lug and/or metal part (check by measuring)
„If necessary, mill off any aluminium parts at the contact point
to ensure proper conductivity (the resistance of the earth conductor must not exceed 0.1 ȍ)
After connecting the earth conductor, proceed as follows:
„Check the strain relief clamps for proper fit
„Check to make sure the cables leading to the connection ter-
minals are properly placed in accordance with applicable
norms
„Perform a visual check of the insulation to ensure it is in
proper condition
© SKIDATA AG, Version 1.0
Page 17
1
1.2
Parking Column
Parking Column for System SPT 400
„Slightly tug at the wires to check whether the terminal screws
are fastened properly
„Check to ensure the connectors are plugged in properly
„Reattach the cover of sd591
„Perform a visual check and manual inspection of the earthing
connection
„Check to make sure that none of the wires are strained
Note:
If the Parking Column is powered up at temperatures below
2 °C, the control assembly will not start up to prevent possible
damage. In that case, the built-in temperature control system
will activate the heater (make sure that all doors are closed to
allow for the device to warm up as quickly as possible).
1.2.10
Surge protection for external devices
In case additional devices (e.g., relays, controls, etc.) are installed inside the chassis (on the top-hat rail), any relay contacts
and coil connections must be protected against transient voltage
by means of appropriate components (e.g., diodes, RC elements,
varistors, etc).
1.2.11
Weather protection
Important:
Opening the device while it is exposed to rain or snowfall may
cause damage to the components inside.
To avoid moisture damage when performing installation work,
you can protect the open device against moisture by means of
an umbrella (see illustration below).
Before opening the device during or shortly after a rain or
snow shower, use a cloth to wipe down the top cover and upper edge of the front panel to avoid moisture getting inside
while opening the device.
Page 18
© SKIDATA AG, Version 1.0
1
Parking Column
Parking Column for System SPT 400
1.2
Fig. 13:
Using an umbrella for moisture
protection when performing maintenance work
Fig. 14:
Column top – Detail: umbrella
holding frame
© SKIDATA AG, Version 1.0
Page 19
1
1.2
Parking Column
Parking Column for System SPT 400
1.2.12
MANUAL OPEN/CLOSE switch
Fig. 15:
OPEN/CLOSE switch on sd591
Switch positions
„Position 0: Normal operation
„Position 1: Keep CLOSED
„Position 2: Keep OPEN
Single gate passage
„Briefly set the switch to position 2; after the barrier opens, set
it back to the 0 position
„If no vehicle passes through the gate, the barrier will close
automatically after approximately ten seconds
Page 20
© SKIDATA AG, Version 1.0
1
Parking Column
Parking Column for System SPT 400
1.2.13
1.2
Installing devices in the front panel
Fig. 16:
Installing devices in the front
panel
Fig. 17:
Installing devices in the front
panel – inner side – Top view
© SKIDATA AG, Version 1.0
Page 21
1
1.2
Parking Column
Parking Column for System SPT 400
Important: Devices and cables intended for subsequent installation must bear a CE label (EU countries) or UL/CSA label (USA; Canada) and must comply with all national and
international standards and guidelines. Installation of such
components may only be performed by qualified electricians.
CAUTION:
When installing devices in the front panel, ensure a minimum
clearance of 5 cm above the fan/heater (see illustration).
The fan/heater must never be covered to avoid the danger
of fire.
To avoid damage to the device, make sure that the fastening
screws of the mounting plate are not screwed in too tightly
(max. torque 0.5 Nm).
When cutting out the metal plate, make sure it is not warped,
as this may cause water to leak into the device.
After installing the desired device(s), check the chassis for
tightness against water and snow.
Page 22
© SKIDATA AG, Version 1.0
1
Parking Column
Parking Column for System SPT 400
1.2.14
1.2
Opening the front panel
To open the front panel, open the column door and pull the locking lever on the inside of the chassis wall forward (see illustration).
© SKIDATA AG, Version 1.0
Page 23
1
1.2
Parking Column
Parking Column for System SPT 400
Fig. 1: Unlocking lever
Page 24
© SKIDATA AG, Version 1.0
1
Parking Column
Parking Column for System SPT 400
1.2.15
1.2
Closing the Parking Column
„Close the top cover and the front panel
„After locking the column door, slide the dust cover back over
the lock
Important:
If the front panel is not closed tightly, water or snow may get
inside the device, causing damage to the electronic assemblies.
After closing the front panel, pull at it slightly to make sure it is
properly closed and locked shut.
Fig. 18:
Closing the column top section
© SKIDATA AG, Version 1.0
Page 25

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 29
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:234a81ab-56d8-4c1c-98fd-81873f27d82c
Producer                        : Acrobat Distiller 6.0 (Windows)
Create Date                     : 2004:05:06 16:05:02+02:00
Modify Date                     : 2004:05:06 16:05:02+02:00
Metadata Date                   : 2004:05:06 13:15:47+02:00
Creator Tool                    : PScript5.dll Version 5.2
Document ID                     : uuid:d8ff8e76-cf8f-4aaa-b848-fd790c8882e4
Format                          : application/pdf
Creator                         : bebe
Title                           : Cover-ColumnSPT400-1-0-en.cdr
Author                          : bebe
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QSS-EXGR400

Navigation menu