Skytech II 3003TRRX Wireless Thermostat Receiver User Manual learn key
Skytech II, Inc. Wireless Thermostat Receiver learn key
Rcvr User Manual
Travis 3003 User’s Manual (Note: The User Manual is for Both Receiver and Transmitter) (Receiver Model No: 3003TR / 3003TR RX) This remote control SYSTEM offers the user a battery-operated remote control that operates most millivolt gas valves used in some heater rated gas logs, gas fireplaces and other gas heating appliances. The transmitter operates on (2) 1.5V AAA batteries. It is recommended that ALKALINE batteries always be used for longer battery life and maximum operational performance. Before using the transmitter, install the (2) AAA transmitter batteries into the battery compartment. (Use caution that batteries are installed in the proper direction) Receiver (Receiver Model No: 3003TR / 3003TR RX) TO WORK WITH TRANSMITTER Put the receiver’s plug in the socket. Connect the Fan / Light / Gas valves to the jack of Receiver Use the transmitter to control the power on/off of Fan / Light / Gas valves. KEY SETINGS MODE – Changes unit to ON / Thermo / OFF mode position. UP / DOWN – Changes temperature, time(r) and other functions’ value. TIMER / FAN / FLAME / LIGHT - Changes each function to enable or disable. OK - Sets temperature, time(r) and other functions. LCD 1. ON / THERMO / OFF Indicates current mode. 2. ROOM °F OR °C Indicates current room temperature. 3. LIGHT Indicates light/valve in operation. 4. AUX Indicates auxiliary function enable/disable.. 5. FLAME Indicates burner/valve in operation. 6. SET °F OR °C Appears the desired temperature to indicate setting room temperature during the time of setting in the thermo operation. 7. Battery icon Indicates the battery is low or not. 8. FAN Indicates fan/valve in operation. 9. TIMER / TIME Appears the time and the countdown timer. MANUAL FUNCTION Initial Setup Press the “ “ key and the “LIGHT” key on the transmitter at the same time. this will into the initial setup mode. Each function scale setting is changed by “UP” or “DOWN” key. 1. Setting °F / °C Scale The setting is for changing temperature °F / °C. 2. Setting Swing Scale The setting is for swing temperature. 3. Setting Gas Type The setting is for gas type NG / LP. 4. Setting Time The setting is for time. Mode To operate the system in the manual “MODE” does the following. ON OPERATION Press the “MODE” key into the ON mode. The appliance flame and fan will come on. During this time the screen will show ON. All the functions, FAN / FLAME / TIMER, will be active. THERMO OPERATION Press the “MODE” key into the THERMO mode. The transmitter will check the ROOM temperature and SET temperature to decide the situation THERMO ON or THERMO OFF. After 2 seconds the LCD screen will display the situation by temperature detected that is comparing with the SWING temperature scale. OFF OPERATION Press the “MODE” key into the OFF mode. The appliance flame and fan will shut off. During this time the screen will show OFF. All the functions, FAN / FLAME / TIMER, will be shut down exception of LIGHT function. THERMOSTAT FUNCTION SETTING DESIRED ROOM TEMPERATURE This remote control system can be thermostatically controlled when the transmitter is in the THERMO mode. To set the THERMO MODE and DESIRED room temperature, During the THERMO mode, Press “Up” / “DOWN” key the LCD screen set numbers will increase / decrease between 45° and 99°(*) then loop the temperature. THERMO ON situation During this mode the screen will display the set flame/valve and fan/value at the same time enable the functions setting. THERMO OFF situation During the situation the functions, FAN / FLAME / TIMER, will be shut down exception of LIGHT function NOTE: (*) The highest SET temperature is 99° Fahrenheit (32° Celsius) and the lowest temperature is (45° Fahrenheit (6° Celsius) FCC Compliance Statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Notice 15.21 Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Company : CMT Source Modified : D:20071009040849 Create Date : 2007:10:09 12:09:38+08:00 Creator Tool : Acrobat PDFMaker 7.0 for Word Modify Date : 2007:10:09 12:09:49+08:00 Metadata Date : 2007:10:09 12:09:49+08:00 Document ID : uuid:c089ceca-83de-4373-909c-6a99c021c192 Instance ID : uuid:4f877649-3ccf-421d-8901-dfa37206af35 Version ID : 3 Format : application/pdf Title : learn key: Creator : jiang Subject : Headline : Page Count : 5 Page Layout : OneColumn Author : jiangEXIF Metadata provided by EXIF.tools