AF-4000TRHH Operation description Modified by Javy 2008/04/11   This remote control SYSTEM offers the user a battery-operated remote control that operates most millivolt gas valves used in some heater rated gas logs, gas fireplaces and other gas heating appliances.  The transmitter operates on (2) 1.5V AAA batteries.  It is recommended that ALKALINE batteries always be used for longer battery life and maximum operational performance.  Before using the transmitter,  install the (2) AAA transmitter batteries into the battery compartment. (Use caution that batteries are installed in the proper direction)         KEY SETINGS  MODE Changes unit to ON / Thermo / OFF mode position. UP / DOWN Changes temperature, time(r) and other functions’ value. Fn Changes each function by the key and uses UP/DOWN key to change that’s value.  SET Sets temperature, time(r) and other functions.
 LCD  1. SUN/MON/TUE/WED/THU/FRI/SAT  Indicates the day. 2. P1/P2 Indicates program is enable or not in own     period time. 3. TIMER / TIME Appears the time and the countdown timer. 4. ON / THERMO / OFF  Indicates current mode 5. ROOM °F OR °C Indicates current room temperature. 6. SET °F OR °C Appears the desired temperature to indicate   setting room temperature during the time of   setting in the thermo operation.  7. Battery icon       Indicates the battery is low or not 8. Swing Indicate the swing scale between require temperature and room temperature. 9. Continuous Pilot Indicates continuous pilot enable/disable. 10. AUX Indicate the Auxiliary equipment is enable or not. 11. LIGHT Indicates light/valve in operation. 12. FAN Indicates Fan/valve in operation. 13. REAR Indicates Rear burner/valve in operation. 14. MAIN Indicates Main burner/valve in operation.
 MANUAL FUNCTION  Initial Setup Hold SET and UP buttons simultaneously for 5 seconds to enter set-up. Each function scale setting is changed by “UP” or “DOWN” key.  Setting of C/F conversion: C/F conversion: Use UP or DOWN key to choose Celsius or Fahrenheit, Press "SET" button to continue to gas type setup.  Setting of Swing Scale: Swing Scale: Use UP of DOWN key to change the swing value (1° to 3°F (1° to 2°C), Press "SET" button to continue to clock set up.     Clock Setup:   Use UP of DOWN key to select the day of the week. Use UP or DOWN key to set HOUR, then press SET to enter “Minute” setting. Use UP or DOWN key to set “Minute”, and then press SET to enter AM/PM setting. Use UP or DOWN key to set AM/PM, the press SET to enter day of week setting.  Mode To operate the system in the manual “MODE” does the following.  ON OPERATION  Press the “MODE” key into the ON mode. The appliance flame and fan will come on. During this time the screen will show ON. All the functions could be chosen that MAIN FLAME/ REAR FLAME / FAN/ LIGHT/ AUX/ TIMER /Program, will be active.   THERMO OPERATION  Press the “MODE” key into the THERMO mode. The transmitter will check the ROOM temperature and SET temperature to decide the situation THERMO ON or THERMO OFF. After 2 seconds the LCD screen will display the situation by temperature detected that is comparing with the SWING temperature scale.  OFF OPERATION
Press the “MODE” key into the OFF mode. The appliance flame and fan will shut off. During this time the screen will show OFF. All the functions, MAIN FLAME/ REAR FLAME / FAN/ TIMER, will be shut down exception of LIGHT/ Aux/ Program functions.   THERMOSTAT FUNCTION  SETTING DESIRED ROOM TEMPERATURE  This remote control system can be thermostatically controlled when the transmitter is in the THERMO mode. To set the THERMO MODE and DESIRED room temperature,  During the THERMO mode, Press “Up” / “DOWN” key the LCD screen set numbers will increase / decrease between 45° and 99°(*) then loop the temperature.  THERMO ON situation  During this mode the screen will display the set flame/valve, rear flame/valve, and fan/value at the same time enable the functions setting.  THERMO OFF situation  During the situation the functions,    MAIN FLAME/ REAR FLAME / FAN, will be shut down exception of LIGHT/ AUX/ Program functions  NOTE: (*) The highest SET temperature is 99° Fahrenheit (32° Celsius) and the lowest temperature is (45° Fahrenheit (6° Celsius)    FCC Compliance Statement: This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.  Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.  Such modifications could void the user’s authority to operate the equipment.

Navigation menu