Skytech II AF3003TX Remote Control Transmitter User Manual

Skytech II, Inc. Remote Control Transmitter

user manual

Download: Skytech II AF3003TX Remote Control Transmitter User Manual
Mirror Download [FCC.gov]Skytech II AF3003TX Remote Control Transmitter User Manual
Document ID904091
Application ID42qoO18iJaNaVU/AGrFA0A==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize57.72kB (721495 bits)
Date Submitted2008-02-20 00:00:00
Date Available2008-02-21 00:00:00
Creation Date2008-01-15 17:53:21
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2008-02-13 12:28:24
Document TitleMicrosoft Word - AF-4000CFMHH function description _English_.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: huang_javy

AF-4000CFMHH Operation description
This remote control SYSTEM offers the user a battery-operated remote
control that operates most millivolt gas valves used in some heater rated gas
logs, gas fireplaces and other gas heating appliances.
The transmitter operates on (2) 1.5V AAA batteries.
It is recommended that ALKALINE batteries always be used for longer
battery life and maximum operational performance.
Before using the transmitter, install the (2) AAA transmitter batteries into the
battery compartment. (Use caution that batteries are installed in the proper
direction)
KEY SETINGS
MODE
Changes unit to ON / Thermo / OFF mode position.
UP / DOWN
Changes temperature, time(r) and other functions’
value.
FAN / MAIN FLAME/REAR FLAME / TIMER / LIGHT
Changes each function by UP/DOWN key.
SET
Sets temperature, time(r) and other functions.
PROG TIMER
Set / Activate Program Mode.
LCD
1. ON / THERMO / OFF
Indicates current mode.
2. ROOM °F OR °C
Indicates current room temperature.
3. LIGHT
Indicates light/valve in operation.
4. FAN
Indicates Fan/valve in operation.
5. MAIN FLAME
Indicates Main burner/valve in operation.
6. REAR FLAME
Indicates Rear burner/valve in operation.
7. SET °F OR °C
Appears the desired temperature to indicate setting room temperature during the time of setting in the
thermo operation.
8. Battery icon
Indicates the battery is low or not.
9. Continuous Pilot
Indicates continuous pilot enable/disable.
10. TIMER / TIME
Appears the time and the countdown timer.
11. Program Function
Indicates program is enable or not in own period time.
MANUAL FUNCTION
Initial Setup
pressing the FLAME REAR and PROG/TIME buttons simultaneously for 5 seconds. this will into the initial
setup mode. Each function scale setting is changed by “UP” or “DOWN” key.
Setting of C/F conversion:
C/F conversion: Use UP or DOWN key to choose Celsius or Fahrenheit, Press "SET" button to continue to
gas type setup.
Gas Type Conversion:
NG/LP conversion: Use UP of DOWN key to choose Natural Gas or Liquid Propane, Press "SET" button to
continue to clock set up.
Clock Setup:
Use UP or DOWN key to set HOUR, then press SET to enter “Minute” setting.
Use UP or DOWN key to set “Minute”, and then press SET to enter AM/PM setting.
Use UP or DOWN key to set AM/PM, the press SET to enter day of week setting.
Use UP of DOWN key to select the day of the week.
Mode
To operate the system in the manual “MODE” does the following.
ON OPERATION
Press the “MODE” key into the ON mode. The appliance flame and fan will come on. During this
time the screen will show ON. All the functions, FAN / MAIN FLAME/REAR FLAME / TIMER / LIGHT,
will be active.
THERMO OPERATION
Press the “MODE” key into the THERMO mode. The transmitter will check the ROOM temperature
and SET temperature to decide the situation THERMO ON or THERMO OFF. After 2 seconds the LCD
screen will display the situation by temperature detected that is comparing with the SWING temperature
(2°F / 1°C) scale.
OFF OPERATION
Press the “MODE” key into the OFF mode. The appliance flame and fan will shut off. During this
time the screen will show OFF. All the functions, FAN / MAIN FLAME/REAR FLAME / TIMER, will be
shut down exception of LIGHT function.
THERMOSTAT FUNCTION
SETTING DESIRED ROOM TEMPERATURE
This remote control system can be thermostatically controlled when the transmitter is in the
THERMO mode. To set the THERMO MODE and DESIRED room temperature,
During the THERMO mode, Press “Up” / “DOWN” key the LCD screen set numbers will increase /
decrease between 45° and 99°(*) then loop the temperature.
THERMO ON situation
During this mode the screen will display the set flame/valve and fan/value at the same time enable the
functions setting.
THERMO OFF situation
During the situation the functions, FAN / FLAME / TIMER, will be shut down exception of LIGHT
function
NOTE: (*) The highest SET temperature is 99° Fahrenheit (32° Celsius) and the lowest temperature is (45°
Fahrenheit (6° Celsius)
FCC Compliance Statement:
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
This device must accept any interference received, including interference that may
cause undesired operation.
Note: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the
user’s authority to operate the equipment.
15.19 FCC Compliance Statement
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
15.21 Statement
Changes or modifications not expressly approved by the party
responsible for
compliance could void the user’s authority to operate the equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
About                           : uuid:c5e7bf06-fdb9-4d85-ab3f-0d48eee5a448
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2008:02:13 12:28:24+08:00
Create Date                     : 2008:01:15 17:53:21+08:00
Metadata Date                   : 2008:02:13 12:28:24+08:00
Document ID                     : uuid:fbbde890-5830-4113-9944-0b9a39fdd1ca
Instance ID                     : uuid:d74e653d-83a1-4326-ae31-c1dbe4d6406a
Format                          : application/pdf
Title                           : Microsoft Word - AF-4000CFMHH function description _English_.doc
Creator                         : huang_javy
Has XFA                         : No
Page Count                      : 4
Author                          : huang_javy
EXIF Metadata provided by EXIF.tools
FCC ID Filing: K9LAF3003TX

Navigation menu