Sleep Number 6000A Dual Temperature Engine User Manual

Select Comfort Corp Dual Temperature Engine

User Manual

TEMPERATURE BALANCING LAYER INSTRUCTION MANUALDualTempSMIf you ever have product questions or need additional assistance obtaining optimal comfort, please visit us at sleepnumber.com or call 1.800.472.7185Representatives are available:(Central Standard Time):Monday–Friday 8 a.m. – 6 p.m.Saturday 8:30 a.m. – 5 p.m.Sunday ClosedConnect with us on Facebook and TwitterFacebook.com/SleepNumber       Beds.com/TwitterHelp is just a click or phone call away.®Click to see DualTemp™ in actionFPO2:00 2:00Sara
TEMPERATURE BALANCING LAYER INSTRUCTION MANUALDualTempSMIf you ever have product questions or need additional assistance obtaining optimal comfort, please visit us at sleepnumber.com or call 1.800.472.7185Representatives are available:(Central Standard Time):Monday–Friday 8 a.m. – 6 p.m.Saturday 8:30 a.m. – 5 p.m.Sunday ClosedConnect with us on Facebook and TwitterFacebook.com/SleepNumber       Beds.com/TwitterHelp is just a click or phone call away.2:00 2:00Sara
5 6The DualTemp™ system features an extraordinary comfort layer that can be added to any bed and an innovative cooling and heating source. It allows you to select your ideal temperature on each side at the simple touch of a button. So you both can achieve a balanced, blissful night’s sleep. DualTemp™ Comfort Layer (1)Heating and Cooling Source (2)Remote (2) Batteries includedPower Supply (2)Power Cord (2) DualTemp™ Layer It’s a new degree of sleep.What’s Inside.
AssemblyFollow these 6 simple steps to correctly assemble your DualTemp™ comfort layer.Place the DualTemp™ comfort layer on the bed with the lighter side facing up.1Place the heating and cooling source on the floor next to your bed or underneath it on a level surface.2Insert batteries in the remote and press the   button to bind the remote to the heating and cooling source.2:00Sara6Connect the power supply to the heating and cooling source and to the power cord. Plug the power cord into an outlet or surge protector.3Plug the power supply into the first heating and cooling source. 4Attach the connector to the heating and cooling source by aligning the notch on the connector to the silver ball on the heating and cooling source. Push together until you hear a click.5Repeat steps 2–6 on the other side of the DualTemp™ comfort layer with the second heating and cooling source and it’s remote.
Remote FunctionUse the up/down buttons to control the warming/cooling levelsCooling levelslow medium high2:00Heating levelsFanlow medium highAfter installing batteries, press the   button and follow the on-screen instructions to set up your remotes.2:00SaraThere are three levels of cooling, with the fan speed increasing as the setting gets cooler. The cool air circulates underneath you to keep you sleeping cool and comfortably, so you won’t wake up hot. Blows room-temperature air underneath you for extra breathability;  it may feel cool.There are three levels of heating, with the fan speed increasing as the setting gets warmer. The warm air circulates underneath you to keep you comfy and cozy with a warm sleeping environment.
Optimize  DualTemp™ comfort layer performance • Tomaximizethermalcomfort,itisrecommendedtoturnonthe DualTemp™ comfort layer 20 minutes prior to going to bed. Keep the layer covered with a blanket/comforter/quilt to maintain the desired temperature.• TheDualTemp™ comfort layer is meant to be used on top of your mattress/mattress pad and underneath a fitted sheet only. For best results, place a blanket/comforter/quilt on top of the bed to create a comfortable micro-climate.  • DonotplaceamattresspadontopoftheDualTemp™ comfort layer.  Doing so will greatly reduce the performance of the system.    • Usesheetsmadefromabreathablematerialthatwillallowthe air to flow through. Flannel and micro-fleece sheets are not recommended; they will reduce the airflow and the effectiveness of the system.• Optional:Formoreairowtothefootofthebed,ortoreduce the level of white noise created from air blowing in the DualTemp™ comfort layer, you may place the layer on the bed with the connectors at the foot of the bed. Be sure the lighter gray side of the comfort layer is facing up.• Ifyouoftenwakeuptoowarmortoocold,itisrecommended to set the timer for your DualTemp™ system to turn off after 3-5 hours.  Optimize heating and cooling source performance• Systemairtemperatureisdependentontheroomtemperature. In a cool room, the settings will be cooler,  than in a warmer room.    • TheDualTemp™ system is not a replacement for  air-conditioning or heating your home.• Ifyouhaveabedskirtandwanttooptimizethecomfortlayer’s thermal performance you may need to place the heating and cooling source next to the bed vs. underneath, or consider removing your bed skirt.• Ifyoustoreitemsunderyourbed,ensureyouhavea1footopen perimeter around the heating and cooling source. • Theltersontheheatingandcoolingsourceshouldbecleaned or replaced every 6 months. They may be washed and reused or additional filters may be purchased from Sleep Number. See page 13 for instructions on cleaning/replacing filters. NOTE: When using the cooling mode in a high humidity environment, water can collect in the bottom of the  heating and cooling source. The water will automatically  be removed during the refreshing system cycle. Do not unplug and avoid moving the heating and cooling source  until the cycle is complete.Warnings• TheDualTemp™ System is not to be used with an adjustable base.• Theconnectorattheheadofthebedshouldnotbepinched between the bed and any other object, as this will degrade system performance.DualTemp™ System OperationUsing the TimerThe timer may be set to turn off the DualTemp™ system after a specified length of time. The timer can be set for 1–9 hours. To set the timer, press the button on the side of the remote. Then press the up arrow on the front of the remote until you reach the desired length of time. If you do not set the timer, the system will automatically shut off after 10 hours.
My heating and cooling source will not turn on • Makesurethepowersupplyissecurelypluggedintotheheating and cooling source and the power cord is securely plugged into a working wall outlet or surge protector.NOTE: A grounded electrical surge protection device is recommended. Test outlet by plugging in another working appliance.• Checktomakesuretheoutletisnotcontrolledbya wall switch.  • Verifythatthepowersupplylightisilluminated.My DualTemp™ comfort layer is not getting warm/cool • ItisimportanttoturnontheDualTemp™ comfort layer for 20 minutes to achieve the desired temperature. •Thesystemwarms/coolsbasedontheroomtemperature. If your room is extremely cold it may affect the comfort layer’s performance. Increasing the temperature of your bedroom should assist the layer in achieving the warmth level desired. •Iftheroomistoohotitmayaffectthelayer’sperformance.Decreasing the temperature of your bedroom should assist the layer in achieving the level of coolness desired.• Coverthebedwithablanket/comforter/quilttoinsulateandkeep the warm/cool air from escapingMy remote does not work •Checkthebatteries.Ifthebatteriesarenotworkingtheyshould be replaced.• Verifythatyouareusingthecorrectremotefortheappropriate side of the bed.My heating and cooling source does not shut off • Therefreshingsystemcyclemayrunthedryingfansupto14hours after use. Once the system has completed refreshing it will shut off on its own.One or both of the sides of the DualTemp™ system turn off while in use • TheDualTemp™ system is designed for 10 hours of continuous use. There is an automatic shutoff after 10 hours of use.• Checktoensuretheconnectorisattachedtotheheatingandcooling source. • Verifythatthesleeptimerwasnotset.The foam has an odor • WhenremovingyourDualTemp™ comfort layer from its packaging, you may notice a new product scent. The scent is non-toxic, normal and is associated with the production of the foam.• Ifyouwishtoreducethevolumeofthescent,simplyallowthe product to air out in a well-ventilated, shaded, open space for up to 48 hours.The system is noisy • Youmayexperiencethewhitenoiseofthefansastheyoperate the heating and cooling source. Wood or tile floors may create slightly more white noise. Place a carpet or other sound absorbing material directly beneath the heating and cooling source.• Operateatalowersettingtoreducewhitenoise.My connector is not long enough or my heating and cooling source does not touch the floor • Placetheheatingandcoolingsourceonabookorboxtolift it.Troubleshooting
DualTemp™ comfort layer care1.  Outer Cover  • Machinewashgentlecycleincoldwater.Linedry.NOTE: The top of the comfort layer can be zipped off for washing. It is recommended that only the top portion of the cover be removed for washing.2.  Comfort layer  • Ifnecessary,spotcleanfoamwithawarm,soapysolutionusing a mild detergent. Do not saturate. Air dry.3.  Active layer  • Ifnecessary,spotcleanwithawarm,soapysolutionanddamp cloth using a mild detergent. Do not saturate.  Air dry.4.  Heating and cooling source and remote  •Wipebodyofheatingandcoolingsourceandremotewith a clean cloth dampened with a mild soap and water solution. Do not immerse in water or place in dishwasher.•Wipethedisplayscreenoftheremotewithaclean,dry,lint-free cloth.Replacing the filters  •Removethemagneticlterframefromthetop of the heating and cooling source.  Next, remove the used filter and replace it with the new shorter filter. Replace the magnetic filter frame.•Removethemagneticlterframefromthe front/side of the heating and cooling source. Remove the used filter and replace it with the new longer filter. Replace the magnetic filter frame.•Replacementlterscanbeorderedat a Sleep Number® store, online at sleepnumber.com or by telephone at  1-800-472-7185.Cleaning the filters  •Removethemagneticlterframefromthetopofthe heating and cooling source, then remove the filter. Replace the magnetic filter frame. Remove the magnetic filter frame from the front/side of the heating and cooling source and remove the second (longer) filter. Replace the magnetic filter frame.•Heatingandcoolingsourcelterscanbehandwashed with a mild liquid soap. Air dry the filters completely before replacing them in the heating and cooling source.•Toreplacethecleanlters,removethemagneticfilter frame from the top of the heating and cooling source and place the shorter filter in the rectangular space. Replace the magnetic filter frame. Repeat with the magnetic filter frame on the front/side of the heating and cooling source and the longer filter.Product Care12
30 Day In-Home TrialWe are confident that you will be completely satisfied with your Sleep Number DualTemp™ system. Please take into consideration that it may take several weeks to adjust and get completely comfortable. After 30 days, if for any reason you decide to return the system, contact Customer Service before packing  it up. Simply call us toll-free within 45 days of delivery to authorize its return. Upon receipt, we’ll reimburse the full purchase price less your initial shipping or Home Delivery and Setup fees. You pay return shipping. All merchandise being returned must be in good condition and be given a Return Merchandise Authorization number from Customer Service, which will expire 30 days from date of issue. All refunds will be issued to the original method of payment within approximately 15 business days after all products have been received at Sleep Number. All shipping and incidental charges to return the bed are the customer’s responsibility.3-Year Limited Warranty  What is covered: • SelectComfort(“SleepNumber”)providesalimitedwarranty for your DualTemp™. The limited warranty provides protection from defects in materials and workmanship for a period of 20 years from the original purchase date. Warranty is limited to product repair or replacement only.• SleepNumber,atitsoption,willrepairorreplacethewarranted product or component.• SleepNumberreservestherighttosubstituteproductsor components of equal or better quality, and to use or deliver refurbished products or components in the repair or replacement of any product under this Limited Warranty.What is not covered:• Conditionsarisingfromnormalwearandtear.(Conditionsarising from normal wear and tear include, but are not limited to: foam compression or discoloration of components)• Damagefromtamperingwithanycomponentorfromopening the heating and cooling system• Damagefrommisuseorabuseofthewarrantedproductorcomponent• Damagefromlaunderingordry-cleaning• Actsofnature,suchasbutnotlimitedtolightningdamage• Sale,transferorotherdisposalofthewarrantedproduct or componentWhat you must do:• Returnthewarrantedproductorcomponentinsanitarycondition to an authorized Sleep Number® service center. Sleep Number will incur the cost of shipping.• PleasetelephoneourCustomerServicedepartmentatthenumber on the back cover to locate the nearest authorized service center and arrange for the return of the warranted product or component.Important Safety Instructions  • Theremoteisnotatoyandshouldonlybeusedunder adult supervision.• Donotopenheatingandcoolingsourceorremote(s) (with the exception of the battery compartment). The warranty  is void if these units are tampered with.• Keeptheheatingandcoolingsourceandremote(s)awayfrom heat sources such as radiators, heat registers, etc.• Heatingandcoolingsourceandremote(s)arenotwaterresistant. Do not use or store near water – for example, in a wet basement,  near an open window, etcWarning: There are no user serviceable parts inside the heating  and cooling source. Any attempt to do so shall void the warranty.FCC Compliance Electrical components are rated for 110/120 voltage, 60Hz, 3.9 amp. Components meet Class B digital device rating (Part 15, FCC rules) for residential use.Warning: Any attempt to make changes or modifications to the remote (e.g. an intentional radiator) could void the user’s authority to operate the remote according to FCC certification (section 15.231).Per FCC 15.19(a)(3) and (a)(4) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Warranty & Notification

Navigation menu