Smarfid Security Equipment MG321356M Magic Series 13.56 MHz Reader User Manual

Shanghai Smarfid Security Equipment Co, Ltd. Magic Series 13.56 MHz Reader Users Manual

Users Manual

Keypad & Proximity Flash Mount Reader Installation Manual Mounting: 1.  Install the metal plate on the wall with two or four screws, which depends on different kinds of gang box being installed1.  2.  The cover shall clip on the upper edge 2 the push in the bottom part as show in diagram3.  3.  Tighten the secure non-dropout screw, which located underneath of the reader to fix the reader and the back plate4, installation is completed.    Specification:    Recommendation: 1.  Linear DC Power Supply; 2.  22AWG shielded cable; it’s required to do “one-point” ground. (As shown in the diagram)   Wiring:  Power up Sequences:  1.  When reader is powered up, the Green back will flicker for 5 seconds. The reader will beep Input Voltage (at Reader end)  DC10V~15V  Typical Read range  > 5cm Operating Current  160mA (max)  Maximum Cable Length  150m Operating Temperature  -30ºC~70 ºC  Number pad format 4 bits burst by defaultColor  Label  Description Red  +12V dc  Power Supply to the reader Black  GND  Signal GND Green  Data0  Wiegand Output data, D0 White  Data1  Wiegand Output data, D1 Yellow  RED LED  RED LED control, active low. Blue  Green LED  Green LED control, active low Brown  Buzzer  Buzzer input, active low Orange  Tamper  Tamper output (open collector, Active low, max 100mA)
Keypad & Proximity Flash Mount Reader Installation Manual once and the reader is in Ready mode. 2.  Present the card. The Blue LED will flicker once; buzzer will beep once.   3.  When card is present and read by the reader, blue back lit will flash once; and buzzer will beep once as well. The card data will then transmit to the controller. After, weather the back lit of the reader will remain ON or Flash or change to Green or Red color, this shall depend on the Green and Red LED inputs. 4.  For number pad reader, when a number is pressed and successfully detected, the back lit under the number will flash 1 time and the buzzer will beep once. The number being pressed will burst out by default (4 bits burst).  Physical Dimension:       Troubleshooting:      Trouble List  Solution No Response when Power Up z  Discount the power and confirm that the power supply cable is correctly connected (See “Wiring” above). z  Check the input voltage is sufficient (See “Specifications” above). Auto Restart  z Check the input voltage is sufficient (See “Specifications” above). Cannot read card number correctlyz  Check the format setting on the controller if it is the same as the card format. Use approved card (known format and Facility Code) to test. z  Check if the shield cable is correctly connected to Classis Ground at ONE point only. Reader beeps but No card data infoz  Check if data 0 & data 1 cable is correctly connected (See “Wiring” above). z  Check the input voltage at the card reader end is correct (See “Specifications” above). Buzzer error  z  Check if the buzzer cable is correctly connected (See “Wiring” above). Back Lit Error z  Check the Led cable is correctly connected (See “Wiring” above). z  Use Default Configuration Card to set it back to normal.

Navigation menu