SmartLabs 2474DWH Wireless Remote Control AC Dimmer User Manual 2474DWH Owners Manual

SmartLabs, Inc. Wireless Remote Control AC Dimmer 2474DWH Owners Manual

Users Manual

Download: SmartLabs 2474DWH Wireless Remote Control AC Dimmer User Manual 2474DWH Owners Manual
Mirror Download [FCC.gov]SmartLabs 2474DWH Wireless Remote Control AC Dimmer User Manual 2474DWH Owners Manual
Document ID1649837
Application IDXbuPJ+ushf/d2Bv4p37Ilg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize45.11kB (563840 bits)
Date Submitted2012-03-06 00:00:00
Date Available2012-03-09 00:00:00
Creation Date2012-03-06 10:12:33
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2012-03-06 10:14:32
Document TitleMicrosoft Word - 2474DWH Owners Manual.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: jlockyer

On-Line Owner’s Manual Containing
Cautionary FCC & IC Statements
March 6, 2012
Wireless Remote Control AC Dimmer
INSTEON SwitchLinc 2-Wire Dimmer Model: 2474DWH
SMART Wall Dimmer 2-Wire Model: 4742A3
FCC ID: SBP2474DWH IC: 5202A-2474DWH
The owner’s manual below may be accessed freely via the Internet
with any web browser and supports the PDF format.
http://www.smarthome.com/2474DWH.html
Complies with Section 5 of FCC document 784748 D01 Labeling Part 15 18 Guidelines v07 where
cautionary statements in the user manual may be provided over the Internet.
SwitchLinc™ 2-Wire Dimmer
Owners Manual
#2474DWH
Page 3 of 32
2474DWH- Rev: 3/6/2012 10:13 AM
Product Requirements Document...........................................................................................................1
Installation ................................................................................................................................................5
Identifying the Electrical Wires in your Home..........................................................................................5
Installation ..............................................................................................................................................6
Local Control ............................................................................................................................................7
Setup Local Settings ................................................................................................................................7
Local On-Level........................................................................................................................................7
Local Ramp Rate ....................................................................................................................................7
Change LED Brightness (or turn it off) ....................................................................................................8
INSTEON Setup ........................................................................................................................................8
INSTEON Controllers, Responders and Links ........................................................................................8
Make SwitchLinc a Responder................................................................................................................8
Make SwitchLinc a Controller..................................................................................................................9
Groups (keeps devices synchronized) ....................................................................................................9
Scenes....................................................................................................................................................9
Add Multiple Responders...................................................................................................................... 10
Stop SwitchLinc from Responding to an INSTEON Controller .............................................................. 10
Stop SwitchLinc from Controlling an INSTEON Responder .................................................................. 10
Stop SwitchLinc from Controlling Multiple INSTEON Responders ........................................................ 10
Factory Reset ....................................................................................................................................... 11
Changing the Paddle and LED Colors .................................................................................................. 12
Specifications ......................................................................................................................................... 13
Troubleshooting ..................................................................................................................................... 15
Certification and Warranty..................................................................................................................... 16
Certification........................................................................................................................................... 16
FCC & Industry Canada Compliance Statement ................................................................................... 16
ETL / UL Warning (Safety Warning)...................................................................................................... 16
Limited Warranty................................................................................................................................... 16
About SwitchLinc 2-Wire Dimmer ......................................................................................................... 17
Features & Benefits................................................................................................................................ 17
Product Requirements ........................................................................................................................... 19
This specification covers only information that is not already covered in the manual or its specification
table above. .......................................................................................................................................... 19
Competitive Information ........................................................................................................................ 19
Suggested Implementation in HouseLinc.............................................................................................. 19
Firmware Description............................................................................................................................. 20
INSTEON Commands Supported ......................................................................................................... 20
Memory Map......................................................................................................................................... 31
Page 4 of 32
2474DWH- Rev: 3/6/2012 10:13 AM
Installation
CAUTIONS AND WARNINGS
Read and understand these instructions before installing and retain them for future reference.
This product is intended for installation in accordance with the National Electric Code and local regulations in the United States or
the Canadian Electrical Code and local regulations in Canada. Use indoors only. This product is not designed or approved for use
on power lines other than 120V 60Hz, single phase. Attempting to use this product on non-approved power lines may have
hazardous consequences.
Recommended installation practices:
Use only indoors or in an outdoor rated box
Be sure that you have turned off the circuit breaker or removed the fuse for the circuit you are installing this product into.
Installing this product with the power on will expose you to dangerous voltages.
Connect using only copper or copper-clad wire
This product may feel warm during operation. The amount of heat generated is within approved limits and poses no hazards.
To minimize heat buildup, ensure the area surrounding the rear of this product is as clear of clutter as possible.
Each INSTEON product is assigned a unique INSTEON ID, which is printed on the product’s label.
To reduce the risk of overheating and possible damage to other equipment, do not use this product to control loads in excess
of the specified maximum(s) or, install in locations with electricity specifications which are outside of the product’s
specifications. If this device supports dimming, please note that dimming an inductive load, such as a fan or transformer,
could cause damage to the dimmer, the load bearing device, or both. If the manufacturer of the load device does not
recommend dimming, use a non-dimming INSTEON on/off switch. USER ASSUMES ALL RISKS ASSOCIATED WITH
DIMMING AN INDUCTIVE LOAD.
Identifying the Electrical Wires in your Home
Line - usually Black, may also be called HOT, LIVE or Power, carries 120VAC/60Hz electricity into the wall box
Neutral - usually White commonly daisy chained from box to box usually appearing as a White wire bundle
Load – usually Black from a separate cable jacket
Ground - Bare wire or metal fixture (if grounded)
IMPORTANT!
If you have any difficulties or questions, consult an electrician. If you are not knowledgeable about, and comfortable with electrical
circuitry, you should have a qualified electrician install the product for you.
In the Box
SwitchLinc 2-Wire Dimmer
Three wire nuts
Quick Start Guide
Page 5 of 32
Tools Needed
Slotted screwdriver
Phillips screwdriver
Wire cutter / stripper
Voltage Meter
Optional Accessories
RemoteLinc 2
SmartLinc
2474DWH- Rev: 3/6/2012 10:13 AM
Installation
1)
2)
3)
4)
5)
6)
7)
8)
At electrical panel, turn off circuit breaker(s) feeding wall box (verify that power is off)
Remove wallplate and unscrew the switch you are replacing and gently pull out
Disconnect wires from switch1
Turn breaker on
Use a voltage meter to identify the line and load wires which connected to the switch
Identify ground
Turn breaker back off
Connect wires
SwitchLinc Wire
Bare copper
Red
Black
Wall Box Wire (common colors)
Ground (bare copper, green wire or green screw)
Light / load (red or blue)
Line (black)
9) Gently place SwitchLinc into wall box, oriented with the LED bar on left and screw into place
10) Turn breaker on
Light will turn on
LED turns white and indicates brightness of light
11) Verify SwitchLinc is working properly by turning the light on and off
12) Reinstall the wallplate
If the wires cannot be detached by unscrewing them, cut the wires where they enter the switch, then strip ½” of insulation off the ends
Page 6 of 32
2474DWH- Rev: 3/6/2012 10:13 AM
Local Control
Follow these instructions to control the connected light/load (as well as responders, if any) from the dimmer paddle.
SwitchLinc Paddle
Top
Bottom
Tap
Press & hold
Double-tap
LED
On
Brighten
On
ramped
until release or 100%
instant
Off
Dim
Off
Bottom
ramped
until release or off
instant
LED Off
White
Setup Local Settings
Local On-Level
The local on-level is the brightness that the light physically wired to SwitchLinc will come on at when turned on at
the SwitchLinc paddle. The default is 100% brightness. Local on-level can be set to any one of 32 fixed brightness
levels (3% to 100%) or “resume bright” (brightness prior to last being turned off).
1) Adjust the light to the desired brightness
2) Tap the Set button once
SwitchLinc will (Beep)
3) Test by pressing On/Off
Local Ramp Rate
The local ramp rate is the time it takes for the lamp to brighten from off to 100% brightness when controlled at the
paddle. It is adjustable from instant to 8 minutes (with software) and instant to 9 seconds (using Set button). Default
ramp rate is 0.5 seconds.
Setting Ramp Rate is done using brightness level as an indicator for how fast SwitchLinc should ramp.
a. Use the Up / Down paddle on SwitchLinc to set brightness

Set Brighter level for a faster Ramp Rate
o 100% corresponds to a 0.1-second Ramp Rate (fast Ramp Rate)

Set Dimmer for a slower Ramp Rate
o Full-off corresponds to a 9-second Ramp Rate (slow Ramp Rate)
1) Adjust the connected light(s) to brightness corresponding to desired Ramp Rate
2) Double-tap Set button on your SwitchLinc
SwitchLinc will (Beep)
3) Test Ramp Rate settings by tapping On/Off paddle on your SwitchLinc or Controller
Connected light(s) will ramp up and down at the new rate
4) Start again if the ramp rate is not as desired or, if your double tap was not fast enough you may have
accidentally changed the Local On-Level instead of the Local Ramp Rate
Note:


Page 7 of 32
Software allows you to set on-levels and Ramp Rates exactly as desired and consistently around the
house
Ramp Rates can be extended up to 8 minutes via home automation software
2474DWH- Rev: 3/6/2012 10:13 AM
Change LED Brightness (or turn it off)
1)
2)
3)
4)
5)
Press & hold SwitchLinc set button until it beeps (3 seconds)
SwitchLinc LED will begin blinking green
Press & hold set button until it beeps again (3 seconds)
SwitchLinc LED will start blinking red
Press & hold set button until it beeps a third time (3 seconds)
SwitchLinc LED will stop blinking
SwitchLinc Status LED will illuminate at current LED brightness level
Use the paddle to brighten or dim the LEDs to desired brightness
a. Press & hold paddle top to brighten
b. Press & hold paddle bottom to dim
Once you have reached the desired brightness for your LEDs, tap set button once
SwitchLinc will beep
LED’s now set to new brightness level
INSTEON Setup
INSTEON Controllers, Responders and Links
Let’s define a few terms.

The INSTEON “transmitter” is called a Controller

The INSTEON “receiver” is called a Responder

The association between the controller and responder is called a Link
Link
Controller
Responder
Please note that a link is one way. If you wish to have control “the other way”, simply repeat link setup process “the
other way”. Most INSTEON devices can store hundreds of links. Furthermore, a controller can simultaneously
control from 1 to hundreds of responders using what are called groups and scenes. Each link can have its own
properties (e.g. 50% brightness at a 4 second ramp rate).
Make SwitchLinc a Responder
Follow the steps below to create a link, enabling another INSTEON device to control SwitchLinc.
1) Press & hold controller button until beep (or LED blinks)
Controller LED will start blinking
2) Adjust SwitchLinc to desired brightness / state for link
Load turns on and LED turns white
3) Press & hold SwitchLinc set button until double-beep
Controller will (beep)-(beep) & LED stops blinking
4) Test by tapping controller button on and off
SwitchLinc will turn on and off
Link
Controller
SwitchLinc
(Responder)
Notes:
- The link just created is one-way, see “Make SwitchLinc a Controller” to add another link to keep the two
products in synch.
Page 8 of 32
2474DWH- Rev: 3/6/2012 10:13 AM
-
If you wish the load to be off when link is activated (such as for an “all off” scene), turn the load off in step #2
Make SwitchLinc a Controller
Follow the steps below to control a different INSTEON device from SwitchLinc.
Press & hold SwitchLinc set button until it beeps
SwitchLinc LED will start blinking green
2) Turn responder on
Link
3) Press & hold responder set button until it double-beeps
SwitchLinc LED will stop blinking2
Responder
Responder LED will stop blinking and (Beep)-(Beep) 3
SwitchLinc
5) Test by tapping SwitchLinc paddle on and off
(Controller)
Responder will toggle on and off
Notes:
- If you wish to add another responder, repeat steps 1-5
- The link just created is one-way, see “Make SwitchLinc a Responder” to add another link to keep the two
products in synch.
1)
Groups (keeps devices synchronized)
Devices in a group will all remain synchronized. Every device in a group is a controller of all the other devices as
well as a responder of all the other devices. The most common example of a group is a 3-way lighting circuit (2
switches). For simplicity, we will assume that the desired group level is on.
Example of a 3 way circuit with switches “A” and “B”
1) Turn A and B on
2) Press & hold A set button until it beeps
A status LED will start blinking green
3) Press & hold B set button until it double-beeps
A will (Beep)-(Beep) and its LED will stop blinking
4) Press & hold B set button until it beeps
B LED will start blinking green
5) Press & hold A set button until it double-beeps
B will (Beep)-(Beep) and its LED will stop blinking
6) Test the group by controlling the load from A and then B
The load, A LED and B LED will remain in synch
Scenes
INSTEON scenes allow a controller to set the mood by setting multiple responders to any number of desired levels,
all simultaneously. Software is recommended when setting up and maintaining scenes.
Create a scene with 1 controller and SwitchLinc as a member
1) Press & hold controller button until beep
Controller LED will start blinking green
2) Tap controller set button
Controller LED will start double-blinking green
3) Tap SwitchLinc on & adjust to desired scene state
SwitchLinc LED will be white
4) Press & hold SwitchLinc set button until double-beep
5) For each additional scene member
a. Adjust member to desired scene brightness / state
b. Press & hold set button until double-beep
6) Press & hold controller set button until double-beep
Controller LED stops blinking
If the responder is a multi-Scene device such as a KeypadLinc, tap the Scene button you wish to control until its LED is in the desired Scene state (on or off). You can any state, not just on,
for the responder’s link.
If either the SwitchLinc or responders LED continues to blink, the addition failed. Tap the device’s Set button until LED stops blinking and try again.
If either the SwitchLinc or responders LED continues to blink, the addition failed. Tap the device’s Set button until LED stops blinking and try again.
Page 9 of 32
2474DWH- Rev: 3/6/2012 10:13 AM
7) Test by tapping controller button on and off
SwitchLinc and other scene responders will all respond appropriately
Add Multiple Responders
1) Press & hold SwitchLinc set button until beep
LED will start blinking green
2) Tap SwitchLinc set button
LED will start double-blinking green
3) For each responder you are adding
- adjust responder to desired link/scene state
- press & hold set button until double-beep (or LED flashes)
4) Press SwitchLinc Set button once
SwitchLinc will beep once
LED stops blinking
5) Test by tapping the SwitchLinc on and off
All the responders will turn on and off
Stop SwitchLinc from Responding to an INSTEON Controller
If you no longer want a controller button to control SwitchLinc follow these directions. Note: If you ever wish to uninstall SwitchLinc, it is important that you remove all SwitchLinc responder links. Otherwise, controllers will retry
commands repetitively, creating network delays.
1) Press & hold controller button until beep3
LED will start blinking green
2) Again, press & hold controller button until beep
LED will start blinking red
3) Press & hold SwitchLinc set button until double-beep
Controller LED stops blinking
4) Test by tapping controller button on and off
SwitchLinc will no longer respond
Stop SwitchLinc from Controlling an INSTEON Responder
If you no longer want SwitchLinc to control another device (or are removing SwitchLinc) it is important that you
follow the instructions below for each responder.
1) Press & hold SwitchLinc set button until beep
LED will start blinking green
2) Again, press & hold SwitchLinc set button until beep
LED will start blinking red
3) Press & hold responder set button until double-beep (or LED blinks)
SwitchLinc will (Beep)-(Beep) and LED stops blinking
4) Test by tapping SwitchLinc on and off
Responder will not respond
Stop SwitchLinc from Controlling Multiple INSTEON Responders
1) Press & hold SwitchLinc set button until beep
LED will start blinking green
2) Again, press & hold SwitchLinc set button until beep
LED will start blinking red
3) Tap SwitchLinc set button
LED will start double-blinking red
4) For each responder you are removing
For devices without beepers hold until its LED begins blinking (this may take 10+ seconds)
Page 10 of 32
2474DWH- Rev: 3/6/2012 10:13 AM
- press & hold set button until double-beep
5) Press SwitchLinc Set button once
SwitchLinc will beep once
LED stops blinking
6) Test by tapping the SwitchLinc on and off
None of the former responders will respond
Factory Reset
NOTE: All settings and scenes will be erased
1) Pull set button out (creating an air gap)
2) Wait 10 seconds
3) Press the set button in as far as you can and hold
SwitchLinc will begin a long beep
4) Continue pressing SwitchLinc set button until beep stops
5) Release set button
SwitchLinc LED indicator will turn on momentarily, then turn off
A few seconds will pass
SwitchLinc will (beep)-(beep)
LED will return to normal brightness
The connected lights will come on to full brightness
Page 11 of 32
2474DWH- Rev: 3/6/2012 10:13 AM
Changing the Paddle and LED Colors
You can remove the LED light pipes and/or front paddle and trim frame assembly before or after SwitchLinc is
installed. During the changeover process, power and load may remain on and operating. There are no dangerous
voltages or unsafe areas under the paddle.
1) If SwitchLinc is already installed in the wall, remove the
wallplate from the switch junction box
2) Remove the four Phillips screws that hold the paddle
assembly to the metal frame
3) Pull the entire paddle straight away from the switch. You may
have to wiggle the bottom of the frame to get it free from the
Set button.
Figure 1: Paddle assembly and SwitchLinc body
separated
4) Using a flat blade or needle nose pliers, remove the large light pipe as
shown in Figure 2. Light pipe will snap out of the frame. Do the same
for the small light pipe.
Figure 2: Snap out the light pipes with a
flat tool
5) Choose which LEDs and/or paddle and trim frame you would like to install into SwitchLinc
6) Orient the new small light pipe with its protrusion facing toward center
of the new frame and snap it into place. If placed in backwards or
reversed, it will not click into place. Refer to Figure 3.
7) Orient the new large light pipe with side that has the most protrusions
facing toward the center of the new frame. Using only finger pressure,
snap the light pipe into the frame. Refer to Figure 3.
Figure 3: Insert the new light pipes with the
protrusions facing the center
8) If both light pipes are installed correctly, they will stick straight out from back of the frame, as
shown in Figure 4. If installed incorrectly, they will appear to be tilted as shown in Figure 5.
Page 12 of 32
2474DWH- Rev: 3/6/2012 10:13 AM
Figure 4: Installed correctly
Figure 5: Installed incorrectly
9) Gently place the paddle assembly back onto front of SwitchLinc. A little force may be necessary
to snap the assembly over the Set button. Reinstall four screws that you removed in step 2.
Specifications
General
Product name
SwitchLinc 2-Wire Dimmer - INSTEON Remote Control
Dimmer
Brand / manufacturer
INSTEON
Manufacturer product number
2474DWH
UPC
813922010817
Warranty
2 years, limited
INSTEON
INSTEON powerline mesh
No
INSTEON RF mesh
Yes
INSTEON controller
Yes
INSTEON responder
Yes
Maximum links / scenes
400
Load brightness levels
32 locally (256 with software)
LED Behavior
White when load is on, bottom white LED is on when load is off
Blinks red when responder does not acknowledge (can be
disabled via software).
Blinks red or green during setup.
LED brightness
Adjustable, from off to bright
Local on-level
Adjustable, 32 fixed brightness levels or resume dim
Local ramp-rate
Adjustable from 0.1 seconds to 9 seconds locally (0.1 seconds
to 8 minutes via software)
Local control
Yes
Commands supported as controller
Page 13 of 32
On
Off
Fast-on
Fast-off
Begin bright
Begin dim
End bright
End dim
2474DWH- Rev: 3/6/2012 10:13 AM
Commands Supported as responder
On
Off
Fast-on
Fast-off
Begin bright
Begin dim
End bright
End dim
Incremental bright
Incremental dim
Beep
Go to specific brightness level
Software Configurable
Yes
RF Range
Up to 100’ open air
Phase detect beacon
No, RF only product
INSTEON Device Category
0x01 Dimmable Lighting Control
INSTEON Device Subcategory
0x24
X10
No X10 Support (RF only product)
Mechanical
Mounting
Single gang electrical box
Screw clamp connections
Black – line (16 gauge)
Red – load (16 gauge)
Copper – ground (16 gauge)
NA
Case Color
White paddle (color change kits available), clear back case
Set button
1, clear
Air Gap
Yes (set button pulled out)
Plastic
UV stabilized polycarbonate
Beeper
Yes
LED
9 white brightness LEDs, 1 green/red status LED
Dimensions
4.1" H x 1.8" W x 1.2" D
Weight
3.6oz
Operating Environment
Indoors
Operating Temperature Range
0°C to 40°C (32°F to 104°F)
Operating Humidity Range
0-90% Relative Humidity
Storage temperature range
-5 to 158 F (-21 to 70 )
Wires
Electrical
Voltage
120VAC ±10%, split single phase
Frequency
60Hz
Load type(s)
Wired-in incandescent lighting
Maximum load
600 watts
Minimum load
25 watts
Hardwired remote control
NA
Page 14 of 32
2474DWH- Rev: 3/6/2012 10:13 AM
Retains all settings without power
Yes, saved in non-volatile EEPROM
Standby power consumption
< 1 watt
Certifications
FCC, IC Canada
FCC ID
SBP2474DWH
Safety Approved
ETL (Intertek Testing Services)
Troubleshooting
Problem
Possible Cause
Solution
Make sure circuit breaker is on
LED won’t come On
SwitchLinc not getting power
Check the junction box wires to ensure all
connections are tight and no bare wires are
exposed
Check that a standard incandescent bulb is installed
and is rated for 25-watts or more
SwitchLinc won’t Add to
Scene as a Responder
The Controller may have dropped out
of Add to a Scene mode, or Added
another device
Try Adding SwitchLinc to the Controller again
The INSTEON signal may not be
getting to the “vicinity” of SwitchLinc
Make sure phases are bridged, add additional
INSTEON devices and/or move around existing
INSTEON devices
Controller is a powerline only device
(SwitchLinc 2-Wire is RF only)
You'll need to add a Dual-Band INSTEON device to
bridge between powerline only and RF only devices
Ramp Rate may be extremely slow
Re-Add to Controller with fast Ramp Rate.
See Local Ramp-Rate
The Controller turns
SwitchLinc Off, but not On
SwitchLinc may be Added to the Scene Turn on the light and then re-Add SwitchLinc to the
in the Off state
Controller scene
SwitchLinc is taking a long
time to respond to a
Controller
The load turned on by
itself
The Controller may be sending
commands to a different Responder
that is no longer in use. Commands for
the unused Responder are being
resent and slowing down
communication signals to SwitchLinc.
If the above doesn’t work, perform a factory reset
on the Controller
Ramp Rate may be extremely slow
Re-Add to Controller with fast Ramp Rate.
See Local Ramp-Rate
Another Controller or a timer could
have triggered SwitchLinc
Monitor for recurrence and remove device from the
SwitchLinc’s scene if you can determine what it is. If
necessary perform a factory reset.
The load doesn’t appear to
The Ramp Rate may be set too slow
turn on right away
SwitchLinc is locked up
Remove from the Scene any unused Responders
from the Controller
HINT: If you are using home automation software,
you can easily check and eliminate unnecessary
Scene Memberships
A surge on the powerline may have
glitched it
Set a faster Ramp Rate. See Local-Ramp-Rate
Remove power to SwitchLinc by pulling out the Air
Gap for ten seconds and then push back in. If that
doesn’t work, perform a factory reset
The lights flicker when on The SwitchLinc is not getting enough
Change the light bulb to a standard incandescent
and the SwitchLinc
power from the light bulb. The
bulb of at least 25 watts. You can always set the
repeatedly turns the load
SwitchLinc needs to ‘steal’ some of the brightness level to some lower level and still have
off and on
bulb’s wattage for powering its circuits. the effect of a small-wattage bulb.
If you have tried these solutions, reviewed this Owner’s Manual, and still cannot resolve an issue you are having with SwitchLinc,
please call: 800-762-7845
Page 15 of 32
2474DWH- Rev: 3/6/2012 10:13 AM
Certification and Warranty
Certification
This product has been thoroughly tested by Intertek - ETL SEMKO, a nationally recognized independent third-party testing laboratory. The North American ETL
Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U.S. and Canadian device safety
standards, that the manufacturing site has been audited, and that the manufacturer has agreed to a program of quarterly factory follow-up inspections to verify
continued conformance.
FCC & Industry Canada Compliance Statement
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS-210. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions
suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement.
The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15B of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there
is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off
and on, the user is encouraged to eliminate the interference by one or more of the following measures:
- Re-orient or relocate the receiving antenna of the device experiencing the interference
- Increase the distance between this device and the receiver
- Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver
- Consult the dealer or an experienced radio/TV technician
WARNING: Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
ETL / UL Warning (Safety Warning)
CAUTION: To reduce the risk of overheating and possible damage to other equipment, do not install this device to control a receptacle, a motor-operated appliance,
a fluorescent lighting fixture, or a transformer-supplied appliance.
Gradateurs commandant une lampe a filament de tungstene – afin de reduire le risqué de surchauffe et la possibilite d’endommagement a d’autres materiels, ne pas
installer pour commander une prise, un appareil a moteur, une lampe flourescente ou un appareil alimente par un transformateur.
Limited Warranty
Seller warrants to the original consumer purchaser of this product that, for a period of two years from the date of purchase, this product will be free from defects in
material and workmanship and will perform in substantial conformity to the description of the product in this Owner’s Manual. This warranty shall not apply to defects
or errors caused by misuse or neglect. If the product is found to be defective in material or workmanship, or if the product does not perform as warranted above
during the warranty period, Seller will either repair it, replace it, or refund the purchase price, at its option, upon receipt of the product at the address below, postage
prepaid, with proof of the date of purchase and an explanation of the defect or error. The repair, replacement, or refund that is provided for above shall be the full
extent of Seller’s liability with respect to this product. For repair or replacement during the warranty period, call INSTEON support at 800-762-7845 with the Model #
and Revision # of the device to receive a RMA # and send the product, along with all other required materials to:
Smarthome
ATTN: Receiving
16542 Millikan Ave.
Irvine, CA 92606-5027
Limitations
The above warranty is in lieu of and Seller disclaims all other warranties, whether oral or written, express or implied, including any warranty or merchantability or
fitness for a particular purpose. Any implied warranty, including any warranty of merchantability or fitness for a particular purpose, which may not be disclaimed or
supplanted as provided above shall be limited to the two-year of the express warranty above. No other representation or claim of any nature by any person shall be
binding upon Seller or modify the terms of the above warranty and disclaimer.
Home automation devices have the risk of failure to operate, incorrect operation, or electrical or mechanical tampering. For optimal use, manually verify the device
state. Any home automation device should be viewed as a convenience, but not as a sole method for controlling your home.
In no event shall Seller be liable for special, incidental, consequential, or other damages resulting from possession or use of this device, including without limitation
damage to property and, to the extent permitted by law, personal injury, even if Seller knew or should have known of the possibility of such damages. Some states
do not allow limitations on how long an implied warranty lasts and/or the exclusion or limitation of damages, in which case the above limitations and/or exclusions
may not apply to you. You may also have other legal rights that may vary from state to state.
Protected under U.S. and foreign patents (see www.insteon.com), International patents granted and pending
© Copyright 2012 Smarthome, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845
Page 16 of 32
2474DWH- Rev: 3/6/2012 10:13 AM

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Create Date                     : 2012:03:06 10:12:33-08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2012:03:06 10:14:32-08:00
Metadata Date                   : 2012:03:06 10:14:32-08:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Format                          : application/pdf
Title                           : Microsoft Word - 2474DWH Owners Manual.doc
Creator                         : jlockyer
Document ID                     : uuid:6c269fa5-e4cc-4a0d-9f57-7eb127efe84f
Instance ID                     : uuid:b95ad352-a63b-49f9-ac93-be494f20bd34
Page Count                      : 15
Author                          : jlockyer
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SBP2474DWH

Navigation menu