SmartLabs DR01 INSTEON DIN Rail Dimmer and On/Off Modules User Manual Dimmer

SmartLabs, Inc. INSTEON DIN Rail Dimmer and On/Off Modules Users Manual Dimmer

Contents

Users Manual Dimmer

2452-222/2452-422/2452-522 Rev. 8/13/2012 9:25 AM / See Owner’s Manual for Warranty Information. Protected under U.S. and foreign patents (see www.insteon.com) © Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845   Quick Start Guide INSTEON® DIN Rail Dimmer Model: 2452-222/2452-422/2452-522  About INSTEON DIN Rail Dimmer The compact INSTEON DIN Rail Dimmer module installs directly onto the DIN rail to give you fully dimmable remote control over compatible lights. Note: Installation should only be performed by a qualified electrician or a homeowner who is familiar and comfortable with electrical circuitry. If you have questions, consult an electrician or call the INSTEON Support Line at 800-762-7845.  In the Box - INSTEON DIN Rail Dimmer  What’s Needed - Flathead screwdriver  - Wire cutter/stripper  - Voltage meter  Before Installation Before you install DIN Rail Module behind a switch, you must determine which switch operation mode applies to your switch—latching, single momentary or dual momentary—as each is wired differently:   Latching (default mode): Switch has no central position. It can be tapped on both the top and bottom and remains in that state once released.  Single momentary: Switch can only be tapped in one location. It returns to central position once released.  Dual momentary: Switch can be tapped on both the top and bottom. It returns to central position once released.  Once you have identified your switch type, install DIN Rail module according to the corresponding wiring diagram, then see “Switch Operation Mode” to program DIN Rail module for your specific switch type.  Install INSTEON DIN Rail Dimmer 1)  Turn off breaker/fuse and verify that the power is off 2)  At the DIN rail, strip away wire coating until you have 10mm (1/3”) of bare wire on the ends 3)  After ensuring the wires are not touching, turn on breaker/fuse 4)  Use a voltage meter to identify the fixture’s line, load and neutral wires, then turn off breaker/fuse again 5)  For reference, write down the INSTEON I.D. (on the side of the module) and the load it is controlling 6)  Snap module onto DIN rail. (If installing next to another module, allow 2cm between modules for heat dissipation.) 7)  Connect line, load, neutral and sense wires according to the diagram corresponding to your switch type:  Neutral Line LED Set button Sense #2 ConnectedloadSense #1 Paddle top (on/brighten)Fuse Paddle bottom (off/dim)
2452-222/2452-422/2452-522 Rev. 8/13/2012 9:25 AM / See Owner’s Manual for Warranty Information. Protected under U.S. and foreign patents (see www.insteon.com) © Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845        8)  After ensuring wires are firmly connected and that there is no exposed wire, turn on breaker/fuse Light will turn on and DIN Rail module LED will turn on green 9)  Test connection by tapping DIN Rail module paddle top and bottom Light will turn on and off 10)  If you are installing a single momentary or dual momentary switch, follow the instructions in Switch Operation Mode below to program the correct mode for your switch 11)  If you are planning to manually link DIN Rail module to any INSTEON devices, do so now (see Make DIN Rail Module a Responder and Make DIN Rail Module a Controller below) 12)  Test installation by tapping switch connected to DIN Rail module on and off Light will turn on and off  Switch Operation Mode By default, DIN Rail module is programmed for a latching switch. Program the switch operation for single momentary mode, dual momentary mode or back to latching mode according to your switch type.
2452-222/2452-422/2452-522 Rev. 8/13/2012 9:25 AM / See Owner’s Manual for Warranty Information. Protected under U.S. and foreign patents (see www.insteon.com) © Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845   To determine DIN Rail module’s current switch operation mode, simply tap Set button:   If it beeps, DIN Rail module is configured for a single momentary switch   If it double-beeps, DIN Rail module is configured for a dual momentary switch   If it triple-beeps, DIN Rail module is configured for a latching switch (default) Change to Single Momentary Mode 1)  Press and hold Set button until it beeps LED will start blinking green 2)  Press and hold Set button until it beeps again LED will start blinking red 3)  Press and hold Set button until it beeps a third time LED will start blinking green 4)  Slowly tap Set button four times LED will continue blinking green 5)  Press and hold Set button until it double-beeps LED will stop blinking 6)  Test mode change by tapping switch on and off Light will respond appropriately  Change to Dual Momentary Mode 1)  Press and hold Set button until it beeps LED will start blinking green 2)  Press and hold Set button until it beeps again LED will start blinking red 3)  Press and hold Set button until it beeps a third time LED will start blinking green 4)  Slowly tap Set button five times LED will start double-blinking green 5)  Press and hold Set button until it double-beeps LED will stop blinking 6)  Test mode change by tapping switch top and bottom Light will respond appropriately  Change to Latching Mode (default) 1)  Press and hold Set button until it beeps LED will start blinking green 2)  Press and hold Set button until it beeps again LED will start blinking red 3)  Press and hold Set button until it beeps a third time LED will start blinking green 4)  Slowly tap Set button six times LED will continue blinking green 5)  Press and hold Set button until it double-beeps LED will stop blinking 6)  Test mode change by tapping switch on and off Light will respond appropriately  Make DIN Rail Dimmer a Responder 1)  Press and hold controller Set button until it beeps Controller LED will start blinking green 2)  Adjust load connected to DIN Rail module to desired brightness level 3)  Press and hold DIN Rail module Set button until it double-beeps Controller will double-beep and its LED will stop blinking
2452-222/2452-422/2452-522 Rev. 8/13/2012 9:25 AM / See Owner’s Manual for Warranty Information. Protected under U.S. and foreign patents (see www.insteon.com) © Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845   4)  Test by tapping controller button on and off The light will turn on and off  Make DIN Rail Dimmer a Controller 1)  Press and hold DIN Rail module Set button until it beeps DIN Rail module LED will start blinking green 2)  Adjust responder to desired brightness state (such as on, 50% or even off) 3)  Press and hold responder Set button until it double-beeps DIN Rail module LED will stop blinking 4)  Test by tapping DIN Rail module paddle top and bottom to turn on/off or brighten/dim Responder will turn on and off  Owner’s Manual and Tech Support Owner’s Manual and Quick Start Guide: http://www.insteon.com/support Call: INSTEON Support Line at 800-762-7845   FCC Compliance This device complies with FCC Rules Part 15. Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference that may be received or that may cause undesired operation.   The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: • Re-orient or re-locate the receiving antenna of the device experiencing the interference. • Increase the distance between this device and the receiver. • Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver. • Consult the dealer or an experienced radio/TV technician. WARNING! Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.   IC Compliance This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.   Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Navigation menu