Somfy Systems URTSII Universal RTS Interface II URTSII (#1810872 User Manual urtsi2

Somfy Systems Universal RTS Interface II URTSII (#1810872 urtsi2

User manual

Download: Somfy Systems URTSII Universal RTS Interface II URTSII (#1810872 User Manual urtsi2
Mirror Download [FCC.gov]Somfy Systems URTSII Universal RTS Interface II URTSII (#1810872 User Manual urtsi2
Document ID967955
Application IDL9zZhrJEuGvtjCh+cdbfNg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize14.19kB (177406 bits)
Date Submitted2008-07-09 00:00:00
Date Available2008-07-09 00:00:00
Creation Date2008-07-02 18:58:26
Producing SoftwareCorel PDF Engine Version 3.0.0.576
Document Lastmod2008-07-02 18:58:26
Document Titleurtsi2.cdr
Document CreatorCorelDRAW
Document Author: oconte01

UNIVERSAL RTS INTERFACE II
Operating Instructions
DESCRIPTION
The addressable Universal RTS Interface II (URTSI II) can be used to communicate
between home automation or other third party systems and SOMFY’s RTS Motors and
controls. It is capable of individual or group control, and can be operated via infrared
remote, RS232 and RS485 serial communication. Once an input is activated, an RTS
radio command is sent to the automated window treatment.
Part Number: 1810872
IR Sensor Modular Pin-Out
CONNECTION DIAGRAM
Pin 4
Back of Interface control box
Common
+5V DC
Power
Antenna
Pin 1
IR Sensor Input
IR Signal
RS485 Input/Output
RS232/RS485 Pin-Out
Pin 8
RS232 Input
or RS485 Input
N/C
Common
RS232TX
+5V DC
Pin 1
789
DOWN Button
3 4 56
STOP Button
F01
Power/Transmit LED
UP Button
B CDE
Front of Interface control box
RS232TX
RS485 B
RS485 A
URTSI Address or
RTS Channel
Rotary Switch
NOTE: Do Not remove antenna.
If a new antenna is needed, it
must be ordered from Somfy to
ensure FCC requirements are
maintained.
Program Button
FCC INFORMATION
This device complies with Part 15 of the FCC Results. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including that which may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and , if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna
2. Increase the separation between the equipment and receiver
3. Connect the equipment into an outlet on a circuit different from that to which receiver is connected
4. Consult the dealer or experienced radio/TV technician for help.
WARNING
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
OPERATION
A. INITIAL SETUP
1. Connect a 9v DC transformer (included) to the receptacle on the back of the control box. The LED will light green to indicate power.
2. Be careful not to mount or enclose Interface on or in metal, as this may effect radio reception.
3. Set the RTS Receiver or motor into its Programming Mode. Refer to the installation instructions of the relevant RTS receiver or motor for this procedure.
NOTE: for initial programming provide power only to the motor or control being programmed.
4. Using the rotary switch, select the channel to be programmed. Letters A through F stand for channels 10 through 15, 0 for 16. Briefly press the programming button
(1 sec. max), the window treatment will jog to indicate the channel has been memorized.
5. Repeat the steps above for each channel or product to be memorized, up to 16.
6. To test the control operation, simply press the UP, STOP or DOWN buttons on the front of the control. The window treatment should move appropriately. The LED will
flash red to indicate the radio signal has been transmitted.
B. INFRARED OPERATION
1. The RTS Interface is compatible with Somfy’s multichannel transmitter. Connect an infrared sensor to the appropriate connector on the
back of the Interface.
2. Each individual motor is activated by first aiming the transmitter at the sensor and pressing the desired unit number on the transmitter and then
pressing the UP or DOWN buttons. Press the center button to STOP the window treatment at any time.
C.
1.
2.
3.
RS232 OPERATION
The Somfy RS232 interface uses the following communications settings: 9600 Baud, 8 Data Bits, 1 Stop Bit, No Parity
Set the rotary switch to position 1.
The basic format for communication is as follows: URTSI ADDR MOTOR CHAN DIR
The URTSI address is 01.
The motor channel should be 2 digits from 01 to 16.
The directional commands are:
U = Up D = Down S = Stop
4. Examples:
Motor 1 UP:
01 01 U
Motor 5 DOWN:
01 05 D
Motor 12 STOP:
01 12 S
D. RS485 OPERATION
1. The Somfy RS485 interface uses the following communications settings: 9600 Baud, 8 Data Bits, 1 Stop Bit, No Parity
2. With RS485, it is possible to connect 16 Universal RTS Interfaces on one network. Each Interface will have its own address. To select the address, set the
rotary switch to the desired number. Letters A through F stand for addresses 10 through 15, 0 for 16.
3. The basic format for communication is as follows: URTSI ADDR MOTOR CHAN DIR
The URTSI address should be 2 digits from 01 to 16.
The motor channel should be 2 digits from 01 to 16.
The directional commands are:
U = Up D = Down S = Stop
4. Examples:
URTSI 1, Motor 1 UP:
01 01 U
URTSI 3, Motor 12 DOWN:
03 12 D
URTSI 14, Motor 9 STOP:
14 09 S
URTSI 10, Motor 15 UP:
10 15 U
MECHANICAL SPECIFICATIONS
Overall Dimensions:
L: 3 in.
W: 4 in.
ELECTRICAL SPECIFICATIONS
D: 1 3/8 in.
Power: 9V DC, 200mA
Frequency: 433.42 Mhz
Typical Range (Optimal Conditions): 65 ft.
ORDERING INFORMATION
Description
Part Number
Description
Part Number
Universal RTS Interface II
1810872
1810498
9012093
DB9 to RJ45 Adapter for RS232
DB9 to RJ45 Adapter for RS485
9015028
9015029
MultiChannel Infrared Transmitter
Mini Infrared Sensor
SOMFY CANADA
SOMFY SYSTEMS, INC.
6315 Shawson Drive, Unit #1
Mississauga, Ontario L5T1J2
47 Commerce Drive
Cranbury, NJ 08512
SOMFY SYSTEMS, INC. reserves the right to change,
update or improve this document without prior notice.
Ref. No. 2500872
C SOMFY SYSTEMS, INC. 6/08

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
Create Date                     : D:20080702185826
Modify Date                     : D:20080702185826
Producer                        : Corel PDF Engine Version 3.0.0.576
Author                          : oconte01
Creator                         : CorelDRAW
Title                           : urtsi2.cdr
EXIF Metadata provided by EXIF.tools
FCC ID Filing: DWNURTSII

Navigation menu