Southco H3EM67 Electronic Swinghandle User Manual General open questions

Southco,. Inc Electronic Swinghandle General open questions

Users Manual

Download: Southco H3EM67 Electronic Swinghandle User Manual General open questions
Mirror Download [FCC.gov]Southco H3EM67 Electronic Swinghandle User Manual General open questions
Document ID1963307
Application ID1xNyq+hjWRm3PsODYF2egw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize31.87kB (398313 bits)
Date Submitted2013-05-13 00:00:00
Date Available2013-05-13 00:00:00
Creation Date2013-05-07 15:02:49
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2013-05-07 15:02:49
Document TitleGeneral open questions:
Document CreatorMicrosoft® Word 2010
Document Author: BBarger@southco.com

H3-EM-67-100 Electronic Swinghandle
Operating Instructions
Package Contents
Specifications
H3-EM-67-x00 Electronic Swinghandle
with Proximity Reader (qty1)
EM-0-45827 M3x25 POZIDRIV® Mounting Screws (qty 4)
EM-0-47151 M3x14 POZIDRIV® Mounting Screw (qty 1)
EM-0-45825 Rotation Limiter (qty 1)
E5-C-04 Pawl Screw (qty 1)
M3-0-24943-11 Lock Plug Screw (qty 1) (optional)
EM-0-45826 Top Mounting Bracket (qty 1)
EM-0-45822 Bottom Mounting Bracket (qty 1)
Operating Instructions (qty 1)
H3-EM-67-x00 Electronic Swinghandle with Proximity Reader
Actuator Module
Supply Voltage (VSUPPLY): 12VDC to 24VDC (NOTE: Status LED will blink
red if the supply voltage is out of range.)
Standby Current:
50mA maximum at 12VDC
Operating Current:
200mA maximum at 12VDC (with no external
mechanical load applied to handle
Stall Current:
1A maximum (at 12VDC, limited to 2 seconds)
Operating Transit Time: 1 second maximum (NOTE: Power must be
present during transit times. If power is
removed while the lock slide is moving to the
unlock position, then the control input signal
must be asserted again. If power is removed
while the lock slide is moving to the lock
position, it will complete it’s cycle when power is
restored.)
Electronic Unlock Time: 3 seconds minimum
Open Collector Outputs: Rated for VSUPPLY, 100mA maximum load
Proximity Reader Module
Supply Voltage (VCC):
Operating Current:
12VDC to 24VDC
60mA maximum (no external devices
attached)
Transmit Frequency:
13.56MHz
DATA Signal Voltage:
5VDC
DATA Pulse Interval Time: 40µs
DATA Signal Delay:
2ms
Mounting and Installation
Please refer to Southco trade drawing J-H3-EM-67-100 for mounting and
installation details.
NOTE: Use a #1 POZIDRIV® driver when installing the mounting
screws. See Southco trade drawing J-H3-EM-67-100 for additional details.
1.
2.
3.
4.
Handle
Prox Reader
Tri-Color Status LED
Lock Plug (optional)
Wiring Diagrams
The H3-EM-67-x00 contains two separate functional modules: the actuator
module and proximity reader module. The actuator module controls and
monitors the locking function of the swinghandle. The proximity module
reads the contents of a compatible proximity card and converts it to
Wiegand format.
Features
Installed 13.56MHz proximity reader module with Wiegand data
output
Compatible with MIFARE® Classic cards with 4 or 7byte Unique
Identifier (UID)
Remote lock and unlock capability
Single or multi-point lock actuation
Momentary or continuous lock actuation
Tri-color LED (blue/magenta/red) to indicate lock and handle
status
DIN lock manual override
Accommodates both left and right doors
For indoor use only
These two modules operate independently of each other and require
connection to an access control unit (not provided), as illustrated below,
for the entire product to be fully functional.
WARNING: The H3-EM-67-000 is shipped without a lockplug. This
product must be paired with a Southco-approved lock to function properly.
Use with an unapproved lockplug voids the product warranty.
Contact Southco for additional support.
J-H3-EM-67-100-M_revA
visit www.southco.com for latest version of this document
Page 1 of 4
H3-EM-67-100 Electronic Swinghandle
Operating Instructions
The actuator module of the swinghandle is accessed with a six-position
connector on the rear of the unit, shown below.
NOTE: The mating connectors/harnesses are not provided with the
H3-EM-67-x00. Refer to Southco trade drawing J-H3-EM-67-100 for
mating connector/harness requirements.
Wiegand Data Output
The prox module will read the 4 or 7byte UID from a compatible prox card,
and covert to Wiegand data format, including upper and lower parity bits,
as shown below.
4B UID
lower parity bit
(odd)
upper parity bit
(even)
7B UID
Control Input Signal
Pin
Description
VGND
VSUPPLY
N/C
Control Signal
Electronic Lock
Status
Mechanical Lock
Status
Note
ground (must be same as proximity reader
module)
12 to 24 VDC power supply input (may be
connected to prox reader VCC input)
no connect
command input (9VDC up to supply
voltage, 100 milliseconds minimum)
open collector output (rated for VSUPPLY,
100mA max. load)
open collector output (rated for VSUPPLY,
100mA max. load)
The proximity reader module of the swinghandle is accessed with a fourposition connector attached to a harness connected to the module’s circuit
board. The module’s connector pinout is:
This signal is used to control the electronic lock slide position.
for UNLOCKED position: Supply 9VDC minimum (do not exceed
supply voltage) for at least 100 milliseconds. The lock will
remain unlocked for as long as the signal is present, or a
minimum of 3 seconds. Signal timing can typically be adjusted
at the access control device. The control signal current draw is
less than 10mA.
for LOCKED position: Supply an open contact or 0VDC (0 to
0.5V)
Electronic Lock Status Output and Mechanical Lock Status Output
Signals
Electronic Lock Status Output Signal
This output will be LOW (GND) when the lock slide is electromechanically
moved to the unlocked position. It will be in the open collector state (highimpedance) when in the locked position.
Mechanical Lock Status Output Signal
Pin
Wire Color
Black
Description
GND
Red
VCC
Green
White
DATA0
DATA1
J-H3-EM-67-100-M_revA
Note
ground (must be same as actuator
module)
12 to 24VDC power supply input
(may be connected to EML VSUPPLY
input)
DATA0 output
DATA1 output
This output will be LOW (GND) when the handle is in the open position or
when the keylock in the actuator is manually unlocked. It will be in the
open collector state (high-impedance) when in the secured position.
NOTE: These outputs are open collector outputs rated for VSUPPLY with
a maximum load of 100mA. To avoid damage to the H3-EM, do not
exceed voltage and current ratings.
visit www.southco.com for latest version of this document
Page 2 of 4
H3-EM-67-100 Electronic Swinghandle
Operating Instructions
Status LED and Output Signals
Mechanically Released
The latch is equipped with a tri-color (blue/magenta/red) LED visible from
the front of the latch. This LED provides a visible notification of the latch
status. The different latch states are described below. Please refer to the
Control Input Signal, Electronic Lock Status Output Signal, and
Mechanical Lock Status Output Signal sections for further details on
these signals.
The latch is released by opening the handle or moving the cam from its
lock position.
The Status LED will flash blue.
The electronic lock status output will be at its open collector state
if the electronic lock slide is in the locked position. It will be 0V if
the lock slide is in the unlocked position.
The mechanical lock status output is 0V.
Secured
The latch is securely closed, prohibiting access.
The Status LED will be solid blue.
The electronic lock status output is at its open collector state.
The mechanical lock status output is at its open collector state.
handle secured
in housing, cam
in locked
position
NOTE: The lock sensor is an optical device that senses the presence
of the lock pawl. Reflectivity of the lock pawl material can affect sensing.
Use only Southco-supplied locks.
electronic
lock slide in
locked
position
electronic lock
slide in locked
position
electronic
lock slide in
unlocked
position
lock plug in
unlocked
position
“Secured” State
“Mechanically Released” State
Electronically Released
Handle not Fully Closed
The electronic lock slide is in the unlocked position and the handle can be
pulled open.
The Status LED will alternate flashing blue/magenta.
The electronic lock status output is 0V while the lock slide is in
the unlocked position.
The mechanical lock status output is at its open collector state.
This is an interim state and may occur while closing the handle when the
cam is not secured by the electronic lock slide. The latch is not fully
secured during this state.
The Status LED will alternate flashing blue/red if the cam is not
detected. It will flash blue/red/red if the cam is detected, but the
lock plate is not in the right position. This could be due to
mechanical failure or tampering.
The electronic lock status output is 0V if the lock slide is in the
unlocked position. It will be at its open collector state if it is in the
lock position.
The mechanical lock status output is 0V if the cam is not
detected. It will be at its open collector state if it is detected.
electronic
lock slide in
unlocked
position
handle
secured in
housing, cam
in locked
position
cam not
detected by
latch
cam
detected by
latch
“Electronically Released” State
“Handle not Fully Closed” State
J-H3-EM-67-100-M_revA
visit www.southco.com for latest version of this document
Page 3 of 4
H3-EM-67-100 Electronic Swinghandle
Operating Instructions
Electronic Lock Slide Error
POZIDRIV® is a registered trademark of the Phillips Screw Company
The electronic lock slide does not respond to the command input signal.
The Status LED will flash magenta if the latch is secured. It will
alternate flashing red/magenta if the latch is mechanically
released.
The electronic lock status output is at its open collector state.
The mechanical lock status output will be at its open collector
state if the cam is in its lock position. It will be 0V if the
mechanical key is moved from its lock position.
MIFARE and MIFARE Classic are trademarks of NXP B.V.
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1)
2)
This device may not cause harmful interference and
This device must accept any interference received, including interference that may cause undesired operation.
Industry Canada Compliance Statement
This device complies with Industry Canada license-exempt RSS-210 standard. Operation is subject to the following two conditions:
1)
2)
This device may not cause harmful interference and
This device must accept any interference received, including interference that may cause undesired operation.
For technical support of this product contact: info@southco.com or visit: www.southco.com.
J-H3-EM-67-100-M_revA
visit www.southco.com for latest version of this document
Page 4 of 4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 4
Language                        : en-US
Tagged PDF                      : Yes
Title                           : General open questions:
Author                          : BBarger@southco.com
Creator                         : Microsoft® Word 2010
Create Date                     : 2013:05:07 15:02:49-04:00
Modify Date                     : 2013:05:07 15:02:49-04:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YKRH3EM67

Navigation menu