Spacelabs Healthcare 010-1471ABG 010-1471-00 User Manual 061 2050 00 Rev D
Spacelabs Healthcare, Inc. 010-1471-00 061 2050 00 Rev D
User Manual
91367 SL2200 Compact Monitor Summary The Ultraview SL™ 2200 is a compact monitoring system with a 10.4-inch resistive touchscreen display. Dual-battery slots allow this monitor to be used in transport, as well as at the bedside. The SL2200 includes one single-high module slot that is compatible with all Spacelabs modules. When used with the 91493 Integrated Module Housing (IMH), two additional parameter modules are supported. Features User Interface All controls are on-screen touch keys, with the exception of the power (ON/OFF) key; optional controls include mouse, keyboard, and remote control Size 21.11 cm (8.31 inches) wide 15.85 cm (6.24 inches) high Display Color thin film transistor (TFT) resistive touchscreen liquid crystal display (LCD) Sweep Speed A variety of speeds are available under module control Trace Height 4.2 cm (1.65 inches) 6 cm (2.36 inches) Parameter Capacity Provides three times the number of waveforms purchased, up to a maximum of 12 parameters Alarm Limit Review Provides a snapshot view of bedside alarm limits for all active parameters; this feature is only available with specific Ultraview SL modules Resolution 640 × 480 pixels 31.24 cm (12.3 inches) 10.4 in 27.05 cm (10.65 inches) 26.42 cm Depth: 16.51 cm (6.5 inches) Weight: 5.5 kg (12.1 pounds) with two batteries and recorder www.spacelabshealthcare.com 061-2050-00 Rev. D 9/09 91367 SL2200 Compact Monitor Trends Graphic 1-, 2-, 6-,12-, or 24-hour segments; data is stored in 1-minute resolution Tabular Time increments of 1, 5, 10, 15, or 30 minutes; 1, 1.5, or 3 hours Power An external direct current (DC) power supply provides power to the monitors and up to three Flexport® system interfaces Advanced Power Management Maximizes battery performance during transport; includes battery “fuel-gauge” optional; will send data, including all available waveforms and numerics, to the Ultraview SL network Connectors Three standard USB 1.1 connectors (keyboard, mouse or barcode scanner), synchronous data link control (SDLC for Flexport systems or module housings), RJ45 (10/100BaseT Ethernet), remote alarm light, VGA output (video), RS-232 serial connector Barcode Scanner Support Provides support for using third-party USB-powered barcode scanners; for entering patient demographic data into a patient’s Admit Record (limited to 128 ASCII characters); this feature is only available in the bedside mode. USB-powered bar code scanners must be purchased from the manufacturer Network Communication 10/100 BaseT modular connector (RJ45) provided; wireless is Options 03 Three display zones 04 Four display zones D Perioperative; provides customizable, user-specific display setups and start case/end case functions Note The SL2200 does not support the 91388 Remote Display Controller. N Vital Signs Calculations (Hemodynamics, Oxygenation, Ventilation, and Renal) O Drug Dose Calculations Q Data Shuttle® (for use with selected modules only) supports transfer for up to 24 hours of the database from the monitor, including continuous and episodic events, and trend information for all parameters monitored by modules and Flexport system interfaces www.spacelabshealthcare.com R Patient Data Logger; presents an ASCII data stream of patient name and vital sign data to the serial port in a pre-defined format Paper Speed 1.56, 3.12, 6.25, 12.5, 25, and 50 mm per second (depending on the monitor sweep speed selected) U Dual Channel Internal Recorder Alarm Record Records any parameters in an alarm state when alarm recording is active Printing Method Thermal array print head Resolution Eight dots per mm (vertical) and 32 dots per mm (horizontal) at 25 mm per second sweep speed Paper Heat-sensitive roll of paper, 50 mm wide × 30 m long Prints Manual and automatic alarm recordings for waveforms and vital sign data, trends, calculations; full annotations are included Frequency Response Determined by the parameter recorded Auto Run 20 seconds or duration of alarm violation (whichever is longer) Controls CONVERT TO CONTINUOUS, STOP RECORDING, SLOW ON/OFF, PRINTER ON/OFF Indicators Paper out, unit off Record Enables selection of up to two active monitor channels plus trends X Wireless Ethernet Communication; provides 802.11a/b/g wireless ethernet with WEP, WPA, and WPA2 security; requires site qualification survey to ensure adequate performance 061-2050-00 Rev. D 9/09 91367 SL2200 Compact Monitor Z Wireless Ethernet Communication; provides 802.11b wireless ethernet with WEP security; requires site qualification survey to ensure adequate performance Product Specifications Classification MDD Class IIb EN 60601-1 Class 1 Requires outlet with safety ground (Protective Earth) conductor. Rated for continuous operation. CISPR11, Group 1, Class B Suitable for use in domestic establishments connected to a low-voltage supply network configuration and setup, for up to 600 charge/discharge cycles; operating time is dependent on configuration and usage; 2 hours are required to charge batteries to 100% of capacity with AC connected and the monitor powered OFF; 3-hour charge time required with monitor powered ON. Width 31.24 cm (12.3 inches) Weight 5.5 kg (12.1 pounds) with two batteries and recorder Altitude 0 to 12,192 meters (0 to 40,000 feet) Humidity 95% (non-condensing) Electrical Specifications Mains Power 100 to 240 VAC, 50 to 60 Hz, 2 A Batteries One or two 12-volt (2.45 Ah NiMH) batteries may be used, providing 2.5 to 4 hours of operation with two batteries (TFT display), depending on monitor Isolation Chassis leakage current meets AAMI, UL 60601-1, CSA Std. C22.2 No. 601.1, and IEC 60601-1 standards Physical Dimensions Height 27.05 cm (10.65 inches) Depth 16.51 cm (6.5 inches) Environmental Requirements Storage Temperature -25° to 60° C (-13° to 140° F) Humidity 95% (non-condensing) Operating Temperature 0° to 50° C (32° to 122° F) Altitude 0 to 4,572 meters (0 to 15,000 feet) Electromagnetic Compatibility EN 60601-1-2: 2001 Immunity Emissions (CISPR 11) EN 55011, Class B IEC 61000-4-2 ESD, 8 kV contact/15 kV air IEC 61000-4-4 Burst, 1 kV data and I/O ports/2 kV power ports EN 61000-3-2 Harmonics IEC 61000-4-3 RF fields, 20 volts/meter, 80 MHz to 2.5 GHz IEC 61000-4-5 Surge, 1 kV differential/ 2 kV common mode EN 61000-3-3 Flicker www.spacelabshealthcare.com IEC 61000-4-6 Conducted RF, 3 Vrms 150 kHz to 80 MHz 061-2050-00 Rev. D 9/09 91367 SL2200 Compact Monitor IEC 61000-4-8 Magnetic field (50/60 Hz), 60 Amps/meter IEC 61000-4-11 Power quality, voltage, and frequency variations Accessories P/N 010-1114-01 Dual external NiMH/SLA battery charger, 100 to 240 V P/N 146-0055-00 Rechargeable NiMH battery 90360-01 Remote keypad P/N 016-0369-00 Bedrail hook/quick release mounting plate P/N 010-1622-00 Mouse, USB Length 14.4 cm (5.67 inches) P/N 010-1621-00 Keyboard (U.S. English only; other keyboards are available for use outside the U.S.) Depth 4.19 cm (1.65 inches) P/N 119-0480-00 Power supply* Height 7.14 cm (2.81 inches) Weight 0.455 kg (1.0 pounds) * This accessory is included. A variety of GCX-brand mounting and mobility solutions are available from Spacelabs or GCX directly. Documentation Ultraview® Operations Documents CD-ROM (P/N 084-1101-xx) Spacelabs Healthcare Service Documents CD-ROM (P/N 084-0700-xx) Spacelabs Healthcare Supplies and Accessories Catalog CD-ROM (P/N 084-1201-xx) Regulatory Approvals ® US CSA certified: Meets IEC 60601-1, CSA C22.2 No. 601.1, and UL 60601-1 for electrical safety. IECEE CB Scheme. www.spacelabshealthcare.com 0123 Meets EN 60601-1. CE marked in accordance with the Medical Device Directive 93/42/EEC. 061-2050-00 Rev. D 9/09 91367 SL2200 Compact Monitor 0981 FCCID: CM6010-1471ABG IC: 2434A-01047100 Option X, private wireless 802.11a/b/g 0168 FCC ID: H9PLA4137 IC: 1549104431A Option Z, private wireless 802.11b The embedded wireless options 802.11a/b/g (X) and 802.11b (Z) of this device comply with part 15 of the FCC Rules, with RSS-210 of Industry Canada, and are CE marked in accordance with the RTTE Directive 1999/5/EC. Operation of wireless options X and Z are subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To comply with the FCC’s RF safety Specific Absorption Rate (SAR) requirements, the user must ensure that the monitor, which contains the radiating element of the antenna, is located at least 20 cm (8 inches) away from a person’s head or body. The radio-transceiver may only be used for Wireless Local Area Network (WLAN) operation within a medical facility. It is not intended for home or vehicle use. Changes or modifications not expressly approved by Spacelabs Healthcare will void the user’s authorization to operate this equipment. Ultraview, Ultraview SL, Ultraview Care Network, Flexport, and Data Shuttle are trademarks of Spacelabs Healthcare. Brands and product names are trademarks of their respective owners. www.spacelabshealthcare.com 061-2050-00 Rev. D 9/09
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Title : 061-2050-00 Rev D.fm Creator : robins Create Date : 2009:09:09 13:54:46-07:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2009:09:11 14:10:56-07:00 Metadata Date : 2009:09:11 14:10:56-07:00 Producer : Acrobat Distiller 8.0.0 (Windows) Document ID : uuid:8adecc56-1fd8-4879-959d-3fd1399ab32f Instance ID : uuid:ea9f70f5-2f36-4018-98a3-9b320b11108f Page Count : 5 Author : robinsEXIF Metadata provided by EXIF.tools