Spectralux 14114 Dlink+ w/CPDLC. All-in-one data communications, CPDLC and ACARS in a single LRU User Manual SP Avionics Logo v1 ai

Spectralux Corporation Dlink+ w/CPDLC. All-in-one data communications, CPDLC and ACARS in a single LRU SP Avionics Logo v1 ai

Contents

Installation Manual

Download: Spectralux 14114 Dlink+ w/CPDLC. All-in-one data communications, CPDLC and ACARS in a single LRU User Manual SP Avionics Logo v1 ai
Mirror Download [FCC.gov]Spectralux 14114 Dlink+ w/CPDLC. All-in-one data communications, CPDLC and ACARS in a single LRU User Manual SP Avionics Logo v1 ai
Document ID1874936
Application IDB5L6ArMp26GcVPZdrVezPg==
Document DescriptionInstallation Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize126.15kB (1576857 bits)
Date Submitted2013-01-08 00:00:00
Date Available2013-01-11 00:00:00
Creation Date2011-12-19 16:56:50
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2011-12-19 18:16:29
Document TitleSP_Avionics Logo v1.ai
Document CreatorAdobe Illustrator CS2
Document Author: Corbet Curfman

INST-14114-1
Dlink+ w/CPDLC Installation Manual
Installation Manual
For Dlink+ w/CPDLC
SLC Doc Number INST-14114-1
Revision -
12335 134th Court NE
Redmond, WA 98052
USA
Tel: (425) 285-3000
Fax: (425) 285-4200
Email: info@spectralux.com
RESTRICTION ON USE, PUBLICATION, OR DISCLOSURE OF PROPRIETARY INFORMATION
This document contains information proprietary to Spectralux Corporation, or to a third party to which Spectralux Corporation may
have a legal obligation to protect such information from unauthorized disclosure, use, or duplication. Any disclosure, use, or
duplication of this document or of any of the information contained herein for other than the specific purpose for which it was
disclosed is expressly prohibited, except as Spectralux Corporation may otherwise agree in writing.
Preparer:
Digitally signed by Larry S
DN: cn=Larry S, o=Systems Engineer,
ou=Engineering, email=larrys@spectralux.com, c=US
Date: 2011.12.19 18:16:19 -08'00'
Engineer:
Digitally signed by Larry S
DN: cn=Larry S, o=Systems Engineer,
ou=Engineering, email=larrys@spectralux.com, c=US
Date: 2011.12.19 18:16:29 -08'00'
Digitally signed by Robert W Bernstein
DN: cn=Robert W Bernstein, o=Director of Engineering,
ou=Engineering, email=bobb@spectralux.com, c=US
Date: 2011.12.19 18:10:15 -08'00'
Program Manager:
Digitally signed by David Cierebiej
DN: cn=David Cierebiej, c=US, o=Software Quality Analyst,
ou=Quality Assurance, email=davidc@spectralux.com
Date: 2011.12.19 16:57:56 -08'00'
Quality Assurance
Document Number: INST-14114-1
Rev. -
Page 1 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
CHANGE RECORD
Paragraph
All
Description Of Change
Initial release
Document Number: INST-14114-1
Rev. -
Approval/
Date
Revision
L.Sinn
12/19/2011
SVN
21090
Page 2 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
Table of Contents
Introduction .......................................................................................................................................... 4
Description and Operation.................................................................................................................. 4
Prepare for Installation ........................................................................................................................ 6
Installation and Test .......................................................................................................................... 10
Appendix A – 14114-1-XX Environmental Qualification Form .............................................................. 25
Document Number: INST-14114-1
Rev. -
Page 3 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
1 Introduction
A. This document provides the information required to install the following Dlink+ w/CPDLC part
numbers, including all modification levels:
•
14114-1-XX
“XX” designates the color of the Dlink+ w/CPDLC with a Keyboard Sub-Assembly (front panel). The
only difference is the color of the front panel. Therefore, throughout this document, we refer to the
Dlink+ w/CPDLC Part Number simply as 14114-1. The information contained in this document applies
to all color variants of the Dlink+ w/CPDLC.
B. For required test and repair instructions specific to the Dlink+ w/CPDLC, reference Spectralux
Component Maintenance Manual 23-20-02. The instructions and procedures defined in the CMM are
necessary to ensure the product operates satisfactorily over its service lifetime. Shop level repair is
limited to replacement of Circuit Boards.
C. Spectralux Corporation contact information:
12335 134th Court NE, Redmond, WA 98052, USA
Telephone: +1 425-285-3000
Fax: +1 425-285-4200
Cage Code: 51896
D. The conditions and tests for TSO approval of this article are minimum performance standards. Those
installing this article, on or in a specific type or class of aircraft, must determine that the aircraft
installation conditions are within the TSO standards. TSO articles must have separate approval for
installation in an aircraft. The article may be installed only according to 14 CFR part 43 or the
applicable airworthiness requirements.
2 Description and Operation
A. The Dlink+ w/CPDLC provides Aircraft Communication Addressing and Reporting System (ACARS)
and Controller Pilot Data Link Communications (CPDLC) message capability in one cockpit mounted
Line Replaceable Unit (LRU). The Dlink+ w/CPDLC is a Class 7 transceiver that can be tuned to any
25 kHz channel over the frequency range of 118.000 to 136.975 MHz with a RF output power on all
frequencies shall not be less than 10 watts in the air.
B. The Dlink+ w/CPDLC works in conjunction with a device called the “Personality Module” mounted
separately. The personality module is a serial EEPROM that houses the unit’s configuration and
database. When the unit is powered ON, the unit reads the data from the personality module. The
configuration information determines the aircraft specific information such as tail number and the
hardware configuration (what IO ports are connected and the type of devices connected to those
ports). The personality module is attached to the aircraft in which the Dlink+ w/CPDLC is installed
and connects to the Dlink+ w/CPDLC when installed on the aircraft via the Dlink+ w/CPDLC 11 pin
Mil-Circular connector. Any Dlink+ w/CPDLC that is connected to a given personality module will
operate with the same configuration.
C. The Dlink+ w/CPDLC is cooled through its case and a rear mounted cooling fan. Under normal
operating conditions no additional cooling is required.
D. Figure 2-1 is a perspective view of the Dlink+ w/CPDLC.
Document Number: INST-14114-1
Rev. -
Page 4 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
Figure 2-2 - Perspective View of Dink+ (14114-1 shown)
E. General Specifications
•
DZUS Mount 5.75” W x 4.5” H x 8.71” D (14.6 cm W x 11.4 cm H 22.1 cm D)
•
Weight: 5.1 pounds (2.3 kg)
•
Operating Temperature: -15°C to +55°C
•
Short Time Operating Temperature: -40ºC to +70ºC with reduced power output at greater than
+55ºC
•
Storage Temperature: -55°C to +85°C
•
Environmental: DO-160E
F. Inputs
•
28 VDC (20.5 – 32.2 VDC), 25 watts standby, 160 watts transmitting
•
RF (118 – 136.975 MHz)
•
ARINC 429 Receivers 8
•
Discretes 8
•
10 Base-T Ethernet 1
G. Outputs
•
RF (118 – 136.975 MHz), 10 watts minimum
•
ARINC 429 Transmitters 4
•
Discretes 4
•
10 Base-T Ethernet 1
Document Number: INST-14114-1
Rev. -
Page 5 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
3 Prepare for Installation
A. Installations must be performed per the requirements of FAA Advisory Circular (AC) 43.13-1B and
43.13-2B or later current revisions of these documents and any applicable documents referenced in
these ACs. The ACs describe installation processes including how to locate the Dlink+ w/CPDLC,
antenna requirements, wiring requirements, cable routing, mounting, circuit breaker information and
other required steps. The ACs also include inspection steps and best practice guidance. Personnel
who perform installations must be qualified and must meet all applicable FAA requirements.
B. The Dlink+ w/CPDLC is designed to fit into a standard, 5.75” (14.6 cm) by 4.5” (11.43 cm) Dzus rail
mounting slot. There are two military circular connectors (one 11 pin connector and one 61 pin
connector) and one RF TNC connector mounted to the rear of the unit. These connectors provide all
input/output connections to the Dlink+ w/CPDLC. Tables 1 and 2 show the 11 pin and 61 pin
connections.
C. Connections:
•
The Dlink+ w/CPDLC RF output is a TNC connector that is used to connect to the coaxial cable
running to an aircraft mounted VHF antenna. Use double-shielded coaxial cable RG400, or
equivalent.
The antenna will be vertically polarized and have a frequency range of 118.000-136.975 MHz.
The antenna installation should conform to the applicable RTCA DO-224, Signal-in-Space
Minimum Aviation System Performance Standards for Advanced VHF Digital Data
Communications Including Compatibility with Digital Voice Techniques. The VHF Communication
antenna must have a 50-ohm RF impedance with a maximum VSWR of 3:1. Maximum loss into
the antenna must be less than 5.5 dB. The maximum VSWR presented to the Dlink+ w/CPDLC
TNC connector must be 2:1 tested per RTCA DO-281.
•
The 11-pin connector provides the power/ground, 5 Volt dimming bus, and personality module
interfaces. The 11-pin connector mates with an MS3476L18-11S connector with appropriate
strain relief. This mating connector uses #16 socket crimp contacts (M39029/5-116).
Non-emergency +28 VDC aircraft power is routed to the connector. This power is provided using
one or two 16 AWG wires. The wires are terminated with MS39029/5-116 contacts. The
contacts are inserted into the connector’s “A” and/or “L” positions. If both “A” and “L” connector
positions are used, they must be wired to the same power bus. A 7.5 amp circuit breaker must be
used for protection.
The 28 VDC return (ground) is provided using one or two 16 AWG wire(s). The wires are
terminated with MS39029/5-116 contacts. The contact is inserted into the connector’s “B” and/or
“K” position.
Chassis ground is connected using one 14 AWG wire into the connector’s “J” position.
The personality module may be tie wrapped to the power cable or mounted to a nearby bulkhead.
See installation instructions below.
•
The 61-pin connector provides the unit’s signal interfaces. The 61-pin connector mates with an
MS3476L24-61S connector. This connector uses #20 socket crimp contacts (M39029/5-115).
Single wires for discretes and paired wires for ARINC 429 signals and for ethernet signals must
be used.
The unit was DO-160E qualified in two configurations.
One configuration used shielded single wires and shielded twisted pairs with the shields attached
to ground at both ends. Glenair backshells from the 40 series were used at the Dlink+ w/CPDLC
for short termination of shields to chassis.
Document Number: INST-14114-1
Rev. -
Page 6 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
The other configuration used unshielded single wires and shielded twisted pairs. The shields
were grounded at both ends. At the Dlink+ w/CPDLC end, grounding was accomplished by
connecting the shields to ground pins of the 61-pin connector. The cable was stabilized by a
strain relief. To achieve passing RF emissions results with this configuration, it was necessary to
install Quell Corp. 18-11.9 and 24-61.35 FilterSeals in J1 and J2, respectively.
Other grounding and shielding schemes may be acceptable.
Table 1 - 11-Pin Connector Connections
11 Pin Military Circular Connections – Identifier - J1
Description
Pin(s)
+28V DC POWER
28V DC RETURN
Personality Module CLOCK
Personality Module DATA
Personality Module +3.3V
Personality Module GND
Cockpit Dimming 5V
Cockpit Dimming COMMON
Chassis GROUND
A, L
B, K
Table 2 - 61-Pin Connector Connections
61 Pin Military Connections - Identifier– J2
Description
Ground
429 Transmit + Channel 1
Ethernet Transmit +
429 Receive + Channel 8
429 Transmit - Channel 1
Ethernet Transmit 429 Receive - Channel 8
429 Receive + Channel 1
Ethernet Receive +
429 Receive + Channel 7
429 Receive - Channel 1
Ethernet Receive 429 Receive - Channel 7
429 Receive + Channel 2
Not Used
429 Receive - Channel 2
Output Discrete 1
Input Discrete 7
Output Discrete 2
Input Discrete 8
Not Used
Input Discrete 1
Output Discrete 3
Document Number: INST-14114-1
Pin(s)
A, F, N, a, i, p, s, x, z, GG, KK
AA
BB
CC
DD
EE
FF
HH
Rev. -
Page 7 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
61 Pin Military Connections - Identifier– J2
Description
Pin(s)
Not Used
Input Discrete 2
Output Discrete 4
Input Discrete 5
Not used
Input Discrete 6
Not used
Not used
Input Discrete 4
Not Used
429 Transmit + Channel 2
Not Used
Not Used
429 Transmit - Channel 2
JJ
LL
MM
NN
PP
T/ R TRIGGER
(Factory test use only. Not
used on aircraft)
429 Receive + Channel 3
429 Receive - Channel 3
429 Transmit + Channel 3
429 Receive + Channel 4
429 Transmit - Channel 3
429 Receive - Channel 4
429 Transmit + Channel 4
429 Receive + Channel 5
429 Transmit - Channel 4
429 Receive - Channel 5
429 Receive + Channel 6
Input Discrete 3
429 Receive - Channel 6
D. Figure 3-1 provides the front, rear and side views.
E. Items required for installation will depend on the specific aircraft and situation. Installation items are
not furnished by Spectralux. The following items are required and should be selected and installed
per this document and the Advisory Circulars referenced above.
•
Mounting hardware for Dlink+ w/CPDLC and personality module.
•
Antenna with sealant.
•
Cabling with proper connectors, routing and service loops.
F. Installation approval - The conditions and tests required for TSO approval of the Dlink+ w/CPDLC and
antenna are minimum performance standards. It is the responsibility of the installer to determine that
the aircraft installation standards for a specific type or class of aircraft are in compliance with all
applicable airworthiness standards. Installation in environments in excess of those listed in Appendix
A is not permitted.
Document Number: INST-14114-1
Rev. -
Page 8 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
G. Before installation, perform a pre-modification avionics systems test to verify that the systems that will
be connected to the Dlink+ w/CPDLC are working properly in accordance with their appropriate
maintenance manuals.
H. Visually inspect the Dlink+ w/CPDLC packaging for evidence of shipping damage. Carefully unpack
and inspect the Dlink+ w/CPDLC and associated equipment and verify all the items have been
received. Reject any damaged items before beginning installation. Retain the shipping container and
packaging materials in case reshipment or return to the supplier is necessary.
Figure 3-2 - Front, Side and Rear View (Dimensions in Inches)
I.
The following in needed to configure and load the database:
a. Laptop with ConfigurationLoader software and Ethernet cable.
b.
Aircraft specific information:
i. Aircraft Registration (Tail number, 7 chars max)
ii. ICAO Address (6 characters)
iii. Avionics Indication Display Capability (3 characters)
iv. NSAP Address (40 characters)
v. Agency Code (2 chars)
Document Number: INST-14114-1
Rev. -
Page 9 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
4 Installation and Test
A. Install the Dlink+ w/CPDLC system components per the referenced ACs:
•
The Dlink+ w/CPDLC will be installed in available space in a standard 5.75” (14.6 cm) by 4.5”
(11.43 cm) Dzus rails mounting slot after all cables have been routed and connected.
Temporarily install in place and check for fit issues if necessary. Do not completely tighten
installation hardware until all system components and cables have been installed.
•
VHF Antenna: If not already mounted, install the vertically polarized 118.000-136.975 MHz
antenna. The antenna installation must conform to the applicable RTCA DO-224, Signal-inSpace Minimum Aviation System Performance Standards for Advanced VHF Digital Data
Communications Including Compatibility with Digital Voice Techniques and must have a 50-ohm
impedance with a maximum VSWR of 3:1.
¾
Measure the distance from the antenna to the back of the Dlink+ w/CPDLC and plan for
proper cable routing, securing and service loops.
¾
Cut the RF cable to length and terminate one end of the cable with a TNC plug for connection
to the Dlink+ w/CPDLC and the other end with the proper connector for attachment to the
antenna.
¾
Connect the RF cable to the 50-ohm interface on the antenna. Route the RF cable and verify
the VSWR does not exceed 2:1, per RTCA DO-281, when measured from the Dlink+
w/CPDLC end. Connect to the RF TNC connection on the back of the Dlink+ w/CPDLC.
¾
Ensure the antenna is properly sealed and the installation complies with the requirements of
the referenced ACs.
•
Test mate samples of the proposed 11-pin and 61-pin connectors to the Dlink+ w/CPDLC to
ensure compatibility.
•
Connect the 11-pin connector to provide power/ground, 5 Volt dimming bus, and personality
module interfaces:
•
¾
Mate the 11-pin connector to an MS3476L18-11S connector using #16 socket crimp contacts
(M39029/5-116).
¾
Route non-emergency +28 VDC aircraft power to the connector using one or two 16 AWG
wires. Terminate the wire(s) with the MS39029/5-116 contacts and insert the contacts into
the connector’s “A” and/or “L” positions. If two wires are used, both must be attached to the
same power bus. Protect the circuit using one 7.5 amp circuit breaker per AC 43.13-1B.
¾
Provide 28 VDC return (ground) using one or two 16 AWG wire and terminate the wires using
the MS39029/5-116 contacts and insert the contact into the connector’s “B” and/or “K”
positions. The length of the wire should be kept as short as possible, but always less than 3
feet (1 meter).
¾
The chassis ground is to be a 14 AWG wire in position “J”. The length of the wire should be
kept as short as possible, but always less than 3 feet (1 meter).
¾
If the personality module is tie wrapped to the power cable, the wires are 24 AWG and should
be no longer than 6 inches (15 cm). If the personality module is to be mounted on a nearby
bulkhead then the wiring must be two pairs of twisted shielded pairs up to 3 feet (1 m) long.
The +3.3V and Data lines should be in one pair and the GND and CLK should be in the other
pair with the shields tied to the GND at both ends of the wire.
Connect the 61-pin connector to provide the unit’s signal interfaces:
Document Number: INST-14114-1
Rev. -
Page 10 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
¾
Mate the 61-pin connector to an MS3476L24-61S connector using #20 socket crimp contacts
(M39029/5-115).
¾
The Ethernet pins are to be routed to a convenient bulkhead so there is easy access to the
Ethernet socket. Use CAT5 cable or equivalent to connect from the 61-pin socket to the
bulkhead RJ-45 socket and swap the transmit and receive lines so a standard Ethernet cable
can be used to connect to a PC.
Dlink+ w/
CPDLC
Laptop
Computer
Crossed
Dlink+ w/
CPDLC
Crossed
RJ45
Straight
TX+ (1)
TX+ (B)
Laptop
Computer
TX+
TX- (C)
TX- (2)
TX-
RX+ (D)
RX+ (3)
RX+
RX- (E)
RX- (6)
RX-
Figure 4-1 RJ45 Connection
¾
Refer to section 3C of this document for information about shielding.
•
Secure power cables and interconnecting cables and wiring. Ensure cables are routed away
from interfering areas on the aircraft, are protected from chafing and have required service loops
per the referenced ACs.
•
Inspect the Dlink+ w/CPDLC system installation per the referenced ACs.
•
Complete the Dlink+ w/CPDLC system installation by tightening any temporarily installed
hardware.
B. Load the configuration and database
•
Power up the Dlink+ w/CPDLC. Allow 10 seconds before trying to load the configuration. If none
have been loaded, the Dlink+ w/CPDLC should show its splash screen:
Document Number: INST-14114-1
Rev. -
Page 11 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
•
Connect a Laptop PC containing the ConfigurationLoader software to the Ethernet connector.
•
Load the provided test or customer database as follows. Start theConfigurationLoader software.
Document Number: INST-14114-1
Rev. -
Page 12 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
The configuration file is supplied by Spectralux and is customized for the installation. To select the
configuration click on Browse for Write Configuration and select the appropriate file.
Document Number: INST-14114-1
Rev. -
Page 13 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
Select Open. To write the file, click on Write Configuration:
Document Number: INST-14114-1
Rev. -
Page 14 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
The Dlink+ w/CPDLC will reboot after loading of the configuration is complete and the screen should look
as follows:
Document Number: INST-14114-1
Rev. -
Page 15 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
The Aircraft Specific Information must now be entered, start by selecting MAINT>:
MAINTENANCE MENU


FAIL STATUS>
NEXT
And then select CONFIG>:
Document Number: INST-14114-1
Rev. -
Page 16 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
And then USER EDIT:
Enter the User Password and press ENTER:
Document Number: INST-14114-1
Rev. -
Page 17 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
Now enter the above information.
NOTE: The AC REG (NCC1702), ICAO ADDRESS (123456) and AVIONICS IND (024) are default entries
in the database and are examples only.
Entered information first appears on the text entry line (just above A/B) and when all the text has been
entered for a particular item, select that item.
For example, to enter the AC REG (Tail number), enter the information:
And then select AC REG:
Document Number: INST-14114-1
Rev. -
Page 18 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
Continue in like process until all the information is entered:
To enter the NSAP address & Agency code, press A/B:
Document Number: INST-14114-1
Rev. -
Page 19 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
And the select ADDRESSES:
Enter the 40 digit NSAP number, first 20 digits on “NSAP 01-20” and last 20 digits on “NSAP 21-40”
Note: There is a default entry that needs to be overwritten.
Document Number: INST-14114-1
Rev. -
Page 20 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
After entering the 2nd NSAP line, press A/B,
And enter the agency code:
Select RETURN:
Document Number: INST-14114-1
Rev. -
Page 21 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
Make sure L1 says YES, and select ), select , and press A/B:
Then select ACARS PING:
Document Number: INST-14114-1
Rev. -
Page 23 of 25
INST-14114-1
Dlink+ w/CPDLC Installation Manual
To send a single ping simply press LSK L2 to change the TEST CONTROL to GO. It will send a
message and then change to WAIT until the response is received then go back to STOP. DELAY
CNT will count seconds until the response is received. AVG SEC will show the time it takes to
receive a response. If no response is received after the timeout period the TEST CONTROL will
display FAIL. To send several messages change MSG COUNT to the number of messages. After all
messages have been sent AVG SEC will display the average response time.
Select RETURN:
The *LINK TEST key will send a link test message.
Use the main Maintenance menu (press the USER key, select MAINT>, select 
Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Signing Date                    : 2011:12:19 16:57:56-08:00
Signing Authority               : David Cierebiej
Modification Permissions        : Fill forms, Create page templates, Sign
Form Fields                     : Signature2.3
Field Permissions               : Disallow changes to specified form fields
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : Adobe Illustrator CS2
Create Date                     : 2011:12:19 16:56:50-08:00
Modify Date                     : 2011:12:19 18:16:29-08:00
Metadata Date                   : 2011:12:19 18:16:29-08:00
Thumbnail Width                 : 256
Thumbnail Height                : 64
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 6860 bytes, use -b option to extract)
Document ID                     : uuid:7C9D8AC80613DC11BCADDD4945735780
Instance ID                     : uuid:57ab5253-d1b1-46af-b046-28e2e6e1e041
Derived From Instance ID        : uuid:07144aa7-f679-43e4-9c61-e350191b22e7
Derived From Document ID        : uuid:AF1520440213DC11BCADDD4945735780
Format                          : application/postscript
Title                           : SP_Avionics Logo v1.ai
Creator                         : Corbet Curfman
Has XFA                         : No
Page Count                      : 25
Author                          : Corbet Curfman
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R2H14114

Navigation menu