Spectrum Tracking Systems PROX100 Personal Security Base Transmitter User Manual 52794

Spectrum Tracking Systems, Inc. Personal Security Base Transmitter 52794

8

Download: Spectrum Tracking Systems PROX100 Personal Security Base Transmitter User Manual 52794
Mirror Download [FCC.gov]Spectrum Tracking Systems PROX100 Personal Security Base Transmitter User Manual 52794
Document ID52794
Application ID4azAfkJ0rHm4Dbc8tf6vxA==
Document Description8
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize13.32kB (166471 bits)
Date Submitted1999-08-09 00:00:00
Date Available1999-02-10 00:00:00
Creation Date2001-05-25 19:51:09
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2001-05-25 19:51:17
Document Title52794.pdf
Document Author: VicodinES /CB /TNN

LambdaMetrics, Inc .
Test Report LM05158A
For: ProNet , IncA
NBI—PROXIOO
EXHIBIT E
PROX-100 Installation |nstructions
Installation Instructions
for PROX-IOO Ceiling
Mount
Model: PROX-100C
1.0 Sgecifl ns:
Enclosure:
Dome-Style Enclosure, Figure
Environmental: Operating Ternp.:-20°C to 60“C
Storage Temp: »20"C to 70"C
Rel. Humidity: 5 to 95%
Power: 24V DC, l30mA Typical
RF Frequency: 902 - 928 MHz ISM Band
Figure I, Domesryle Enclosure
Nate: T he PROX-I 00C is shipped completely
assembled and tested DO NOT open plastic
housing as this may harm sensitive electronic
components I/PROX-IOUC is not petforming
properly, please advise Customer Service.
2.0 Mounting:
Mounting locations must be based upon most
recent site survey. The PROX-lOOC should be
mounted as close as possible to identified
locations recorded in site survey.
Installation Orientation:
The PROX-IOOC must be suspended above
acoustic tile in a drop ceiling with dome
protruding through acoustic tile,
NBI—PROXI 00
Installation Location:
Mounting Position: PROX-IOOC should be
mounted in a drop ceiling with supplied
installation hardware (See Section 4.0,
Hardware), Mounting position must be at least
1 foot away from and metal objects such as
HVAC duets, fire sprinkler system lines or other
plumbing lines.
Multiple-Level Installations: PROX-IOOC
detectors must be mounted as directly over one
another as practical itmultiple levels are being
installed.
installation Tips:
- Select a mounting location that is at least 1
foot away from any metal objects such as
HVAC ducts. fire sprinkler system lines or
other plumbing lines.
- Select a mounting location that is not easily
tampered with, obstructed or damaged by
typical traffic in installed area.
- Select a mounting location that is easily
accessible to installed busline and pig-tail
connector to the PROX—lOOC.
- Select a mounting location that the PROX»
100C can be secured firmly to the drop
ceiling.
- Select proper installation hardware to
secure the PROX- l 00W to the construction
ofthe drop ceiling
- Refer to Figure 2 for typical busline loading
and Table 1 for total length per segment
restrictions of PROX—IOOC detectors.
I,500 feet Max. Length
Segm ent- l
Segment-2
Segm cut-3
Segment-4
Figure 2, Typical Busline Loading
Tampus—gl l
_1_
CT-20002
PRONET Communiwfions
5340 LBJ Fro-my, Dill-ll, TX. USA, 75240
Total Number PROX-l 00C PROX-lOOC
of PROX-IOOC Evenly Spaced End Cluster
per Segment
I l500 fl. 1500 H.
2 I 100 R. 700 R.
4 650 fi. 350 fl.
6 450 R. 250 it.
8 300 it. l50 fl.
Table 1. Total Length Per Segment Restrictions
(Assuming 18 AWG Wire. Contact Customer
Service for other Options)
3.0 W ng:
WARNING!!! DO NOT apply power to
segments until all connections have been made
and inspected.
Pig- Tail Assembly:
Fahricate pig—tail assembly as shown in Figure
3. Length ofpig»tail is determined by
installation personnel. Pig-tail length may not
exmd 5 feet.
BLACK. PIN-l
RED. PlNrZ
(DC POWER)
PIN-2, PIN—1
PIN-4 PIN-3
BLACK. PIN-J
WlllTl", PIN-4
(SIGNAL lINFS)
Figure 3. Pigtail Assembly
NBI-PROX l 00
Connecting the PROX-100C:
Feed pi glail assembly through Wirem old". metal
raceway if pigtail is exposed below drop ceiling.
Raceway length should be sulficient to shield
pig-tail From Iine-of-sight of typical traffic.
Afier mounting orientation and position have
been identified use template to cut hole in
acoustic tile (see page 3 for PROX—IOOC hole
template). Place dome halo through hole in
acoustic tile and fold over tabs (3 Places) to
secure dome halo to acoustic rile. This will
beautify the hole previously cut in the acoustic
tile. The PROX-IOOC is now ready to be hung
from the drop ceiling ”r rails using Caddy"
Hardware.
Next. connect the pigtail to the segment busline
using Skotchlok'", 804 (Blue) moisture-resistant
tap connector. This connection is accomplished
by opening a portion ofthe husline outer
insulation wrap to reveal the four conductors in
the busline. Splice pig-tail to busline with
Skotchlok'". 304 (Blue) moisture-resistant tap
connector and be certain to keep busline a
continuous line for other PROX-lOOC detectors
to be spliced into the conductive pathway of the
segment.
Engage connector end of pig—tail to PROX-IOOC
wire harness . Connector may sent into channel
afier coupling has been made, but is not
necessary to seat in channel to function
properly.
4.0 Hardware:
Dome Halo: CT-l0005
Hanger Bracket Assembly: Caddy" BHC
Installation Hanger: CaddywSIZ
Molex Connector: 39700—0039
Molex Pin: 39-01-2040
Molex Hand Crimp Tool: ll-OI-0I97
Beldin Wire: 9156
Skotchlok" 304 (Blue)
Crimping/Striping Pliers
WireMold" V500 Metal Raceway, Ivory
Scufitoathinish
o-o---.
ampus—
PRONET Comm
6340 LBJ Freeway, DIIIII, TX, USA. 75240
CT»20002
ions
NBl-PROXIOO
CUT TEMPLATE FOR
PROX—lOOC DETECTOR
1) PLACE TEMPLATE AT IDENTIFIED
MOUNTING LOCATION OF ACOUSTIC TILE
2) CUT HOLE
CUT HERE /
ampus— -3- (IT-20002
PRONEF Communications
6340 LBJ From-y, mun, Tx,u5A, 152441
Phone: (972) 587-2000 (sax) 225-1911 FAX: (972) 774-0540
NBI—PROX l 00
Installation Instructions
for PROX-IOO Wall
Mount
PROX- 100W
Mod
1.0 Specifications:
Enclosure: Patch-Style Enclosure. Figure 1
Environmental: Operating Temp.:-20°C to 60°C
Storage Temp.: —20°C to 70°C
Rel. Humidity: 5 to 95%
Power: 24V DC. lJOmA Typical
RF Frequency: 902 , 928 MHZ ISM Band
Figure l. Patch-Style Enclosure
Nate: The PROXJ 00W is shipped completely
assembled and tested. DO NOT open plastic
housing as this may harm sensitive electronic
components. 1fPRUX-100Wis not performing
properly, please advise C usmmer Service.
2.0 Mounting:
Mounting locations must be based upon most
recent site survey. The PROX-IOOW should be
mounted as close as possible to identified
locations recorded in site survey.
Installation Orientation:
Alignment ofchannel is to be placed “up" for
indoor applications and “down" for
outdoor/high moisture applications, DO NOT
mount channel to “side.” Please refer to Figure
l.
Campus-91 1w - I-
Installatt'an Location:
Mounting Height: PROX-IOOW should be
mounted 6 feet iiom floor. Maintain eonsistent
heights for all FROX—IOOW detectors. PROX-
IOOW should be placed at a minimum of2 feet
from ceiling. Placing the PROX-lOOW too close
to the ceiling may cause interference with
detector on level above (if multiple levels are
being installed) resulting in the reduction of
level to level location accuracy.
Multiple»Level Installations: PROX-l 00W
detectors must be mounted as directly over one
another as practical ifmulliple levels are being
installed. Maintain consistent heights from
floor and ceiling for all PROX-lOOW detectors
on all levels of building being installed.
Installation Tips:
0 Select a mounting location that is at least 1
foot away from any metal objects such as
HVAC ducts‘ fire sprinkler system lines or
other plumbing lines.
a Select a mounting location that is 6 feet
from floor and 2 feet from ceiling.
- Select a mounting location that is not easily
tampered with, obstructed or damaged by
typical trafiic in installed area.
- Select a mounting location that is easily
accessible to installed busline and pig-tail
connector to the PROX- 100W.
- Select a mounting location that the PROX-
IOOW can be secured firmly to the wall,
- Select proper installation hardware to
secure the PROX-lOUW to the construction
ofthe wall, (Le, plastic or lead anchors)
& Refer to Figure 2 for typical busline loading
and Table 1 for total length per segment
restrictions of PROX-lOOW detectors.
CT-20001
PRONET Communicafions
6340 LBJ Freeway, Dallas, TX. USAV 75140
Phone: (972) 557-2000 (sea) 2257911 FAX: (972) 77s-asqo
Concentrator
1,500 feet Max. Length
”if
Segm ent~l
Segm ent-Z D
Segment-3 IL!
Segment-4 EL:
Figure 2, Typical Busline Loading
Total Number PROX- I 00W PROX- IO0W
of PROX-IOOW Evenly Spaced End Cluster
per Segment
I 1500 it. [500 it.
2 l 100 it. 700 it.
4 650 it. 350 fi.
6 450 ft. 250 fll
8 300 it. ISO 0.
Table 1. Total Length Per Segment Restrictions
(Assuming ls AWG Wire. Contact Customer
Service for other Options)
3.0 W g:
WARNING!!! DO NOT apply power to segments
until all connections have been made and inspected
Pig-Tail Assembly:
Fabricate pig-tail assembly as shown in Figure 3.
Length of pig—tail is determined by installation
personnel. Pig-tail length may not exceed 5 feet.
NBI~PROXl 00
BLACK, PIN-l
RED, PIN—2
(DC POWER)
PIN-Z PIN-l
PIN-3
HI ACK, PIN-3
WHITE, PIN4
(SIGNAL LINES)
Figure 3, Pigtail Assembly
Connecting the PROX—100W:
Feed pigtail assembly through Wiremold'" metal
raceway. Raceway length should be sufficient to
shield pig-tail fi’om line-of-sight oftypical
t'rafiic.
After mounting orientation, height and position
have been identified use template to drill holes (See
page 4 for the PROX-IOOW hole template) for
anchors or to directly secure the unit to wall
material. Connect the pigtail to the segment
busline using Skotchlokm 804 (Blue) moisture-
resistant tap connector. This connection is
accomplished by opening a portion of the busline
outer insulation wrap to reveal the four conductors
in the busline. Splice pig-tail to busline with
Skotchlok“, 804 (Blue) moistureresistant tap
connector and be certain to keep busline a
continuous line for other PROX-lOOW detectors to
be spliced into the conductive pathway ofthe
segment.
Engage connector end ofpig-tail to PROX-lOOW
and secure to wall using listed hardware options.
Connector will seat into channel when mounted to
wall.
Campus-9] IM -2-
CT-20001
PRONET Communluflom
5340 LBJ me, Dallas, TX, USA. 75240
Phone: (972) 637-2000
(sea) 226-7911
FAX: (972) 774-0640
NBI-PROXI 00
4.0 Hardware:
- Molex Connector: 39-00-0039
. Molex Pin: 39»01-2040
. Molcx Hand Crimp Tool: [1-01-0197
- Beldin Wire: 9156
- Sketchlok'“ 304 (Blue)
. Crimping/Striping Pliers
- 810 Plastic Anchors (Sheet-Rock applications)
a $410 Lead Anchors (Concrete Applications)
- #10 PPH Tamperproof Driver
- No, 3 Drill Bit (Anchor Mount)
- N0. 27 Drill Bit (SelfTapping Moum)
- WireMoldm V500 Mam Raceway, Ivory Scufi’Coat‘ Finish
Campus-9] 1 —3— CT-ZOOOI
PRONEY Communicatlons
aw LBJ Freeway. Dallas. Tx, USA, 75140
Phone: (912) 551-2000 1888) 228-7911 FAX: (072) 114.0640
NBI»PROX 1 00
(DRILL HERE)——> Gr)
DRILL TEMPLATE FOR
PROX-IOOW DETECTOR
_OMENTATION OF CHANNEL—>
(UP / DOWN)
1) PLACE TEMPLATE AT IDENTIFIED
MOUNTING LOCATION
2) DRILL HOLES (4 PLACES) PER
MOUNTING HARDWARE REQUIRED
69
(DRILL HERE)——> <9
Campus-91 1 .4. 0120001
PRONET Communications
am LBJ mew-y, mun. TX, USA, 75240
Phone: (972) 667-2000 (no) 226-1911 FAX: (972) 11441540

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2001:05:25 19:51:09
Producer                        : Acrobat Distiller 4.0 for Windows
Author                          : VicodinES /CB /TNN
Title                           : 52794.pdf
Modify Date                     : 2001:05:25 19:51:17-04:00
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NBI-PROX100

Navigation menu