Spot AX630 Direct Sequence Spread Spectrum Module User Manual 630 Transmitter FCC RPT

Spot LLC Direct Sequence Spread Spectrum Module 630 Transmitter FCC RPT

Contents

Updated Users Manual

Download: Spot AX630 Direct Sequence Spread Spectrum Module User Manual 630 Transmitter FCC RPT
Mirror Download [FCC.gov]Spot AX630 Direct Sequence Spread Spectrum Module User Manual 630 Transmitter FCC RPT
Document ID145682
Application IDY19aUDsGpWSEuZgLovNCsw==
Document DescriptionUpdated Users Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize1.07kB (13400 bits)
Date Submitted2001-04-19 00:00:00
Date Available2001-05-15 00:00:00
Creation Date2001-04-19 14:21:16
Producing SoftwareAcrobat PDFWriter 4.05 for Windows NT
Document Lastmod2001-04-19 17:21:46
Document Title630 Transmitter FCC RPT.PDF
Document Creator630 Transmitter FCC RPT.doc - Microsoft Word
Document Author: David Alley

Axonn Corporation
AX630
Transmitter
Users Manual
RF Transmitter Installation Instructions
The AX630 Transmitter is a member of our Spread Spectrum RF family of products. This transmitter
should only be installed by qualified service personnel.
The transmitter detects level, low battery or other data signals from the external binary inputs and
broadcasts that data to the system's host receiver.
MOUNTING LOCATION
The AX630 Transmitter is a module as defined by the FCC and therefore must be mounted to
another host device in order to function.
NOTICE TO CUSTOMER
Any Axonn customer incorporating the AX630 transmitter module into its own product must have
an external notice affixed to its product. This notice must be placed in a conspicuous location
and can use wording such as: “Contains FCC ID: L2VAX630” or “Contains Transmitter Module FCC
ID: L2VAX630”. Any similar wording that expresses the same meaning may be used.
INSTALLATION INSTRUCTIONS
1. Supply the transmitter with DC power by inserting a 3Volt battery into the battery holder on the
customers host application circuit board.
2. The unit will come pre-programmed with Transmitter ID and Property Code. There will be no
field programming of the unit.
3. When installing the AX630 you should avoid areas near screens, metal window frames, circuit
breaker boxes, air conditioners and heaters if a suitable location for the unit may be found
elsewhere.
TESTING THE TRANSMITTER
Following system installation, system testing is mandatory. This should be performed by locating
the AX630 in its final location and powering up the unit. On initial power-up, the AX630 will send
out RF messages every 4 seconds or more depending on programming. This will establish
communications with the Host receiver and the information collected will then be used to judge
system performance.
FCC NOTICE
The Model AX630 transmitter generates and uses radio frequency energy. If not installed and used
in accordance with the manufacturer's instructions, it may cause interference to radio and
television reception. The transmitter has been tested and found to comply with the specifications
in Part 15 of FCC Rules for Spread Spectrum Intentional Radiators and FCC Part 15 Subpart C,
Specifications.
If this equipment causes interference to radio or television reception - which can be determined by
turning the equipment on and off - the installer is encouraged to correct the interference by one or
more of the following measures: 1) Reorient the antenna of the radio/television. 2) Connect the
AC transformer to a different outlet so the control panel and radio/television are on different
branch circuits. 3) Relocate the control panel with respect to the radio/television.
If necessary, the installer should consult an experienced radio/television technician for
additional suggestions, or send for the "Interference Handbook" prepared by the Federal
Communications Commission. This booklet is available from the U.S. Government Printing
Office, Washington, D.C., 20402, stock number 004-000-00450-7.
CAUTION: Axonn Corporation does not support field changes or modifications to any of the
Axonn Corporation RF equipment unless they are specifically covered in this manual. All
adjustments must be made at the factory under the specific guidelines set forth in our
manufacturing processes. Any modification to the equipment could void the user's authority
to operate the equipment and render the equipment in violation of FCC Part 15, Subpart C,
15.247.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
CAUTION:
This device is required to comply with FCC RF exposure requirements for mobile transmitting
devices. A separation of 20 cm (8 inches) or more must be maintained between the antenna
and all persons during device operations to satisfy RF exposure compliance.
LIMITED WARRANTY
THERE ARE NOT WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE
HEREOF. In no case shall Seller be liable to anyone for any consequential or incidental
damages for breach of this or any other warranty, express or implied, or upon any other basis
of liability whatsoever, even if the loss or damage is caused by Seller's own negligence or fault.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Creator                         : 630 Transmitter FCC RPT.doc - Microsoft Word
Create Date                     : 2001:04:19 14:21:16
Title                           : 630 Transmitter FCC RPT.PDF
Author                          : David Alley
Producer                        : Acrobat PDFWriter 4.05 for Windows NT
Modify Date                     : 2001:04:19 17:21:46-04:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: L2VAX630

Navigation menu