Spracht Cp 2012 Users Manual SP1040_5

CP-2012 to the manual 318abf6a-77f1-45e7-87f7-2ca4f2a49bea

2015-02-06

: Spracht Spracht-Cp-2012-Users-Manual-528345 spracht-cp-2012-users-manual-528345 spracht pdf

Open the PDF directly: View PDF PDF.
Page Count: 19

DownloadSpracht Spracht-Cp-2012-Users-Manual- SP1040_5  Spracht-cp-2012-users-manual
Open PDF In BrowserView PDF
Voice Center™
Conference Phone
Model CP-2012

User's Manual

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

2
2
3
3

Analog Telephone System
Setup with Analog Telephone System . . . . . . . . . . . . . . . . . . . . .
Selection of Tone or Pulse Dialing . . . . . . . . . . . . . . . . . . . . . .
Connection of Standard Phone for Private Conversations (Optional)
Keypad Functions with Analog Telephone System. . . . . . . . . . . . . .
Operation with Analog Telephone System . . . . . . . . . . . . . . . . . . .

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

4
5
5
6
7

Digital

Introduction and Quick Start Guide
Package Contents. . . . . . . . . . . . .
Safety Precautions . . . . . . . . . . . .
Analog or Digital Telephone System?
Setup Tips . . . . . . . . . . . . . . . . .

Analog

Table of Contents - Voice Center User’s Manual

Digital Telephone System
Setup with Digital Telephone System . . . . . . . . . . . . . . . . . . . . . . . . . 8
Keypad Functions with Digital Telephone System . . . . . . . . . . . . . . . . 10
Operation with Digital Telephone System . . . . . . . . . . . . . . . . . . . . . 11

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

12
12
13
13

General

General Setup Topics
Tips for Obtaining Optimal Acoustic Performance . . . .
Selecting Number of Built-in Microphones to be Active .
Installation of External Microphones . . . . . . . . . . . . .
Connection of an External Tape Recorder. . . . . . . . . .

Technical Reference
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Spracht Limited Warranty Policy . . . . . . . . . . . . . . . . . . . . . . . . . . 15
FCC Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

1

Introduction
Thank you for choosing the Voice Center Conference Phone, a high performance audio conferencing system.
Its features include:
• Full duplex communication – the Voice Center’s digital speech processing enables simultaneous
two-way communication. This eliminates clipped sentences and awkward one-way conversations,
allowing smooth and natural discussion.
• PBX compatible – the Voice Center Conference Phone has the versatility to function with virtually all
phone systems: standard analog lines, and (with optional digital adapter) even multi-line and digital
PBX systems.
• 360° coverage – four built-in microphones provide 360° coverage so all participants can speak and
be heard clearly from anywhere in the room.
• Convenient controls – The keypad provides control keys for volume, mute, redial, and “flash” (which
enables three-way conference calls). LEDs indicate call status and mute operation.
• Expandable – the Voice Center Conference Phone has input jacks for two external microphones for
use in larger conference rooms, and also includes an RCA output jack so conference calls can be
recorded.
For complete specifications, see page 14 of this manual.

Quick Start Guide
1. Package Contents
Check the package contents to confirm you have everything at hand.

For digital telephone systems, the DT-104 Digital Telephone System Interface (sold separately) is
also required. Contents of the DT-104 Digital Interface package:

2. Safety Precautions
The Voice Center Conference Phone is an electrical product. As with any electrical product,
observe reasonable precautions to avoid risk of fire or electrical shock. Specifically,
• Do not use this product near water, such as near a sink or bath tub, or in a wet area, such
as in a wet basement. Caution: This product is for indoor use only.
• Do not use a telephone during an electrical storm; there is some risk of electrical shock from lightning.
• Do not use this conference phone near a gas leak or vapors that could be ignited.
• Follow the instructions in this User’s Manual.

2

Quick Start Guide
3. Analog or Digital Telephone System?
Caution: if the Voice Center is connected to a digital telephone system using the Analog
Telephone System Interface, it will not operate correctly, and may cause damage to the AT-103
Analog Interface and cause it to overheat. It is therefore important to use the correct interface
for your telephone system.
How do you determine if your telephone system is analog or digital?
The best way is to consult the phone system’s documentation or - in a corporate environment to call your company’s teleservices department. Here is additional information to help you determine the type of phone system you have.

Analog
Analog phones are used for public switched telephone networks plain old telephone service (POTS) from Ma Bell. However, some
private exchanges support analog telephones, fax machines, and
modems. Look at the back of your telephone; if it says, “complies
with Part 68, FCC Rules,” and has a Ringer Equivalence Number
(REN), the phone and line are analog.
For analog telephone systems, use the Voice Center AT-103
Analog Interface shown at right (supplied with the Voice Center
Conference Phone), and follow the installation and operating
instructions that begin on page 4.

Digital
Digital telephone systems are usually found in corporate environments.
Most PBXs (private branch exchanges) are digital. Signs that the
phone and line are digital: phones with multiple function keys and/or
multiple lines, the need to dial 9 for an outside line, no fax machines or
modems connected directly to the phone line. Caution: if analog
equipment is connected directly to a digital telephone system, it will not
work, and the equipment can be damaged.
For digital telephone systems, use the Voice Center DT-104 Digital
Interface shown at right (sold separately from the Voice Center
Conference Phone). The Digital Interface is the same size and shape
as the Analog Telephone System Interface, but has different circuitry;
the Digital Interface can be identified by the 4-position switch on its
front side. For digital telephone systems, follow the installation and
operating instructions that begin on page 8.

4. Setup Tips
• Choose an appropriate location for the Conference Phone.
– Use the Conference Phone in an environment as free as possible from background noise.
– To minimize echoes, position the conference phone at the center of the room, or at least
away from walls.
– Avoid items that could cause noise or acoustic interference.
• Set up the Conference Phone following the instructions for the type of telephone system you are using:
– Instructions for an Analog Phone System begin on page 4.
– Instructions for a Digital Phone System begin on page 5.
• Make adjustments (as necessary) to obtain optimal acoustic performance.
Important: The Voice Center Conference Phone's digital sound processing actively responds to
the acoustic environment. In small and/or reflective rooms, resonance (echoes) can cause
variable performance. Some small adjustments can dramatically improve results. See page 12
for tips to improve acoustic performance.

3

Analog Telephone System
Setup with Analog Telephone System
If you are connecting the Voice Center Conference Phone to an analog telephone system, follow the
instructions below. In North America, use the AT-103 Analog Telephone System Interface supplied with
the conference phone; in Europe, use the AT-104 European Telephone System Interface (available in the
EK-102 international adapter kit). Throughout the instructions, the Voice Center Conference Phone is
referred to as "Conference Phone" and the Analog Telephone System Interface (whether AT-103 for North
America or AT-104 for Europe) is referred to as “Analog Interface”.
1. Connect Conference Phone to Analog Interface using the RJ-45 conference phone cable supplied
with the Conference Phone.
• Plug one end of the RJ-45 conference phone cable (larger than a standard
RJ-11 cable) into the connector labeled “Control Box” on the underside of
the Conference Phone.
• Place the Conference Phone on the table where it will be used. For best
acoustics, place the Conference Phone at least 20 inches (0.5 m) from any
wall and at least 6 inches (0.15 m) from the edge of the table.

• Plug the other end of the RJ-45 cable into the Analog Interface
connector labeled “Conference Phone.”
PHONE

LINE

CONFERENCE
PHONE

DC 15V

PHONE

LINE

CONFERENCE
PHONE

DC 15V

CONFERENCE
PHONE

DC 15V

2. Connect Analog Interface to telephone jack using RJ-11 telephone cable.
• Plug one end of RJ-11 telephone cable supplied with the Conference
Phone into the Analog Interface connector labeled “Line.”
• Plug the other end of that RJ-11 cable into a telephone jack.
3. Connect Conference Phone power adapter to Analog Interface.
In North America, use 120 VAC power adapter (PA-102, supplied with
Conference Phone); in Europe, use 230 VAC power adapter (PA-202,
available in EK-102 European adapter kit).
• Plug DC plug on power adapter cord into the Analog Interface connector
labeled “DC15V.”
• Plug power adapter into a nearby electrical outlet (do not exceed
voltage rating of power adapter).
Note: At this point, the Conference Phone will emit a musical jingle; this
self-test allows it to automatically calibrate its performance for the acoustic environment.
PHONE

4

LINE

Analog Systems
Wall Mounting of Analog Interface (Optional)
• Install the two mounting screws supplied with the Analog Interface in the
wall. Leave approximately 3/16 in. (0.5 cm) between screw head and wall.
• Place the Analog Interface over the mounting screws and slide it down
to fix it in position.

Selection of Tone or Pulse Dialing
The user may select either pulse or tone dialing (DTMF, dual-tone multi-frequency).
To change the dialing mode:
• Slide the switch located on the side of the Conference Phone to match the
dialing mode of the telephone network being used. Factory setting is Tone.

Connection of Standard Phone for Private Conversations (Optional)
To conduct private conversations using a handset, you may connect a
standard analog telephone to the Voice Center Analog Interface:
• Plug a standard RJ-11 cable from the analog telephone into the
connector in the Analog Interface labeled ”Phone”.

PHONE

LINE

CONFERENCE
PHONE

DC 15V

The standard phone is then connected to the telephone line in parallel with the Conference Phone, and
the standard phone and Conference Phone can be used independently.
To transfer a call from the Conference Phone to an external analog telephone connected as noted above:
• Pick up the analog telephone handset while the Conference Phone is on.
• Turn off the Conference Phone by pressing its ON/OFF key.
To transfer a call from the external analog telephone to the Conference Phone:
• While the private call is in progress, turn on the Conference Phone by pressing its ON/OFF key.
• Hang up the handset of the external telephone.

5

Analog Systems
Keypad Functions with Analog Phone System

ON/OFF
Pressing the ON/OFF key turns the Conference Phone on to obtain a dial tone, or turns it off to
terminate a call. When the Conference Phone is on, green LEDs illuminate by all active microphones.
REDIAL
If a dial tone is available, pressing the REDIAL key redials the last number dialed on the
Conference Phone.
Note: you do not need to press ON/OFF before REDIAL.
FLASH
This key provides access to special telephone service features - if you have enrolled in these
services from your local telephone company:
• Call waiting - pressing FLASH key switches between calls (requires subscription to local telephone company’s call waiting service).
• Three-way calling - pressing FLASH key places present call on hold and provides a dial tone;
after dialing another call, pressing the FLASH key once more begins the three-way call (if you
have subscribed to local telephone company’s three-way call service).
Standard 12-button Telephone Keypad (10 digits plus ✱ and # )
Use 12 keys to dial telephone numbers.
▼ (reduce volume)
Pressing ▼ key when phone is ringing (or no call is in progress) decreases the ringer volume.
Pressing ▼ key while a call is in progress decreases the speaker volume.
▲ (increase volume)
Pressing ▲ key when phone is ringing (or no call is in progress) increases the ringer volume.
Pressing ▲ key while a call is in progress increases the speaker volume.
MUTE
Pressing the MUTE key during a call turns off all microphones. Microphone LEDs change to red
to indicate conference phone participants cannot be heard at the other end of the line. Pressing
the MUTE key again reactivates the microphones (and microphone LEDs change from red to
green).

6

Analog Systems
Conference Phone Operation with Analog Phone System
Answering a call
When the Conference Phone rings, press the ON/OFF key to answer the call. The green LED illuminates
to indicate the Conference Phone is on.
Adjusting the speaker volume
While a call is in progress use the ▼ (decrease volume) and ▲ (increase volume) keys to adjust the
speaker volume. The speaker volume setting is saved until adjusted again.
Adjusting the ringer volume
When the phone is ringing (and a call is not in progress) use the ▼ (decrease volume) and ▲ (increase
volume) keys to adjust the ringer volume. The ringer volume setting is saved until adjusted again.
Placing a call
Press the ON/OFF key to obtain a dial tone, then dial the call using the Conference Phone keypad.
Redialing a call
While the Conference Phone is off (green LED not lit), press the REDIAL key to call the last number
dialed. To cancel the automatic redial, press the REDIAL key again.
Muting a conversation
To turn off all microphones during a conversation, press the MUTE key. Microphone LEDs change to red
to indicate conference participants cannot be heard at the other end of the line.
Ending a call
Press the ON/OFF key. The green LED will extinguish.
Accessing special telephone service features
These features are only available if you have enrolled in these services with your local telephone company:
Call waiting:
Press FLASH key to switch between calls.
Three-way calling:
1. Press FLASH key to place present call on hold and obtain a dial tone.
2. Dial the second call.
3. Press the FLASH key once more to begin the three-way call.
Using a standard phone connected to the Analog Interface
A standard analog telephone may be connected to the Voice Center Analog Interface to allow private
conversations using a handset (see setup instructions on page 5), The following instructions explain how
to transfer calls between the Conference Phone and an external telephone connected to the Analog
Interface.
• To transfer a call from the Conference Phone to the external analog telephone:
1. Pick up the telephone handset while the Conference Phone is on.
2. Turn off the Conference Phone by pressing its ON/OFF key.
• To transfer a call from the external analog telephone to the Conference Phone:
1. While the private call is in progress, turn on the Conference Phone by pressing its ON/OFF key.
2. Hang up the handset of the external telephone.

7

Digital Telephone System
Setup of Conference Phone with Digital Phone System
Note: The DT-104 Digital Telephone System Interface is required for use of the Voice Center
Conference Phone with a digital phone system.
Follow the steps below to set up the system. Throughout the instructions, the Voice Center Conference
Phone is referred to as “Conference Phone” and the DT-104 Digital Telephone System Interface is
referred to as “Digital Interface.”
1. Connect Conference Phone to Digital Interface using the RJ-45
conference phone cable supplied with the Conference Phone.
• Plug one end of the RJ-45 conference phone cable (larger than a
standard RJ-22 cable) into the connector labeled “Control Box”
on the underside of the Conference Phone.

• Plug the other end of the RJ-45 cable into the Digital Interface
connector labeled “Conference Phone.”
PHONE

LINE

CONFERENCE
PHONE

DC 15V

2. Connect Digital Interface to digital telephone using RJ-22 telephone handset cables.
• Unplug handset “curly cord” from digital telephone and plug it into
the Digital Interface connector labeled “Handset.”
PHONE

LINE

CONFERENCE
PHONE

DC 15V

• Plug one end of RJ-22 telephone handset cable supplied with the Digital
Interface into the Digital Interface connector labeled “Phone.”

• Plug the other end of that RJ-22 cable into the handset jack on the
digital telephone (from which the handset curly cord was disconnected).
See diagram at top of page 9.
Hang up the handset on the digital telephone.
3. Connect Conference Phone power adapter to Digital Interface.
In North America, use 120 VAC power adapter (PA-102, supplied
with Conference Phone); in Europe, use 230 VAC power adapter
(PA-202, available in EK-102 international adapter kit).
• Plug DC plug on power adapter cord into the Digital Interface connect labeled “DC15V.”
• Plug power adapter into a nearby electrical outlet (do not exceed
voltage rating of power adapter).
Note: At this point, the Conference Phone will emit a musical jingle;
this self-test allows it to automatically calibrate its performance for
the acoustic environment.
Note: See system illustration on next page.

8

PHONE

PHONE

LINE

LINE

CONFERENCE
PHONE

CONFERENCE
PHONE

DC 15V

DC 15V

Digital Systems

4. Use Digital Interface’s 4-position switch to adjust audio level by
making a test call.
• Lift digital telephone handset from its cradle, then press
Conference Phone’s “On/Off” key.
Important: the digital telephone handset must be “off-hook” for
the duration of the call; the Digital Interface disables the handset
microphone when the Conference Phone is on.
• Place the call from the digital telephone’s keypad.
Note: The Conference Phone keypad cannot be used to dial calls
through most digital phone systems; the keypad on the digital telephone must be used.
• Adjust the audio level with the 4-position switch (level 1 is highest,
level 4 is lowest). If the setting is too high for the digital telephone,
the party at the other end of the line may get noise feedback (buzz,
tone, or squeal); if the setting is too low, your voice may be too
faint to be heard.
• End the call by pressing the Conference Phone’s “On/Off” key and
hanging up the digital telephone handset.

Wall Mounting of Digital Interface (Optional)
• Install the two mounting screws supplied with the Digital Interface
in the wall. Leave approximately 3/16 in. (0.5 cm) between screw
head and wall.
• Place the Digital Interface over the mounting screws and slide it down
to fix it in position.

9

Digital Systems
Keypad Functions with Digital Phone System

ON/OFF
Pressing the ON/OFF key turns the Conference Phone on to connect a call, or turns it off to
terminate the Conference Phone conversation. When the Conference Phone is on, green LEDs
illuminate by all active microphones.
With a digital telephone system, Conference Phone calls go through the digital telephone
connected to the DT-104 Digital Interface, and that digital telephone’s handset must be off hook
for the duration of the call. When the Conference Phone is turned on, it disables the microphone
in the digital telephone handset so conversation is conducted only through the Conference Phone.
Standard 12-button Telephone Keypad, REDIAL, FLASH
When using the Conference Phone with a digital telephone system, you must dial calls on the
digital telephone connected to the DT-104 Digital Interface. The standard 12-button telephone
keypad, REDIAL, and FLASH keys do not function with most digital telephone systems.
▼ (reduce volume)
Pressing ▼ key when phone is ringing (or no call is in progress) decreases the ringer volume.
Pressing ▼ key while a call is in progress decreases the speaker volume.
▲ (increase volume)
Pressing ▲ key when phone is ringing (or no call is in progress) increases the ringer volume.
Pressing ▲ key while a call is in progress increases the speaker volume.
MUTE
Pressing the MUTE key during a call turns off all microphones. Microphone LEDs change to red
to indicate conference participants cannot be heard at the other end of the line. Pressing the
MUTE key again reactivates the microphones (and microphone LEDs change from red to green).

10

Digital Systems
Conference Phone Operation with Digital Phone System
Answering a call
1. When the phone rings, pick up the digital telephone handset to accept the call.
2. Press the ON/OFF key to take the call on the Conference Phone. The green LED illuminates to indicate the Conference Phone is on; the microphone in the digital telephone handset is disabled while
the Conference Phone is on.
Note: the digital telephone handset must remain off-hook for the duration of the call.

Adjusting the speaker volume
While a call is in progress use the ▼ (decrease volume) and ▲ (increase volume) keys to adjust the
speaker volume. The speaker volume setting is saved until adjusted again.
Note: When a call is not in progress, pressing the volume keys adjusts the ringer volume. The ringer
volume setting is saved until adjusted again.
Placing a call
1. Pick up the digital telephone handset and dial the call.
2. Press the ON/OFF key to take the call on the Conference Phone.
Note: with a digital telephone system, you must use the digital telephone to dial all calls. You cannot
use the Conference Phone keypad to dial or redial calls with a digital telephone system.
Note: the digital telephone handset must remain off-hook for the duration of the call.
Muting a conversation
To turn off all microphones during a conversation, press the MUTE key. Microphone LEDs change to red
to indicate conference participants cannot be heard at the other end of the line. Press the MUTE key
again to turn on the microphones.
Ending a call
Hang up the digital telephone handset.
Press the ON/OFF key. The green LED will extinguish.

11

General Setup Tips

Tips for Obtaining Optimal Acoustic Performance
• To minimize echoes, place the Conference Phone at the center of the room, or at least away from
walls (at least 20 inches/0.5 m from any wall).
• It is important to place the Conference Phone on the surface where it will be used before applying
power. When power is applied to the Conference Phone, it emits a series of self-test tones to automatically calibrate its performance for the acoustic environment.
• If you significantly change the acoustic environment (for example, by placing the Conference Phone in
a different location), cycle the power (unplug the power adapter, then plug it in again). This allows
the Conference Phone to adapt to its new surroundings and deliver optimal performance.
• Do not move the Conference Phone during a conversation.
• Use the Conference Phone in an environment as free as possible from background noise.
• Whenever possible, keep items that could cause noise or acoustic interference away from the
Conference Phone and (if used) External Microphones. Items that could compromise audio quality
include plants, cups, and papers near the microphones.
• Have speakers direct their voices toward the Conference Phone or (if used) External Microphone.
• Speak at normal conversational volume.
• To obtain best audio quality, adjust the microphone setup for the room size and arrangement:
– In a small, closed room without sound-absorbing walls, use the microphone selection switch to
activate only one of the Conference Phone’s built-in microphones.
– For large rooms and irregular layouts (such as L-, U-, and T-shaped conference tables), connect
External Microphones (EM-101 purchased separately).

Selecting Number of Built-in Microphones That Will Be Active
The user can select how many of the Conference Phone’s built-in microphones
will be active - two, three, or all four. The factory setting is four, but in
smaller rooms and asymmetric conference arrangements, better audio
quality sometimes can be obtained by deactivating one or two of the built-in
microphones. The microphone selection switch is located on the side of the
Conference Phone, and is labeled to indicate the number of microphones
activated.

When the Conference Phone is on, a green LED illuminates by each active microphone.

Setting up the Conference Phone Global Region
The regional switch can be found on the side of the conference as indicated by the arrow.
Please select the appropriate setting for your region 0.6 for Australia
0.3 for the United States
0.1 for Europe.

12

'ENERAL
)NSTALLATIONOF%XTERNAL-ICROPHONES/PTIONAL	
4HE6OICE#ENTER#ONFERENCE0HONEHASBUILT
INMICROPHONESFOR
COMPLETE  COVERAGEINAREASUPTOXFTXM	
4HE6OICE#ENTER#ONFERENCE0HONEHAS2*
INPUTJACKSFORTWOEXTERNAL
MICROPHONESTOEXTENDCOVERAGEINLARGERAREASANDTOALLOWFORIRREGULAR
LAYOUTS6OICE#ENTER%XTERNAL-ICROPHONES3PRACHTCATALOGNO%-
	
ARESOLDSEPARATELYFROMTHE6OICE#ENTER#ONFERENCE0HONE!N%-

%XTERNAL-ICROPHONECOMESWITHAINCHM	CABLEWITH2*

CONNECTOR
4O INSTALLANEXTERNALMICROPHONE
 0LUGTHE2*
MICROPHONECONNECTORINTOONEOFTHETWOMICROPHONE
CONNECTORSONTHESIDEOFTHE#ONFERENCE0HONETHEMICROPHONE
CONNECTORSARELABELEDh%84%2.!,-)#v

 0LACETHEEXTERNALMICROPHONEATLEASTINCHESM	FROMTHE
#ONFERENCE0HONEANDIFPRESENT	ANOTHEREXTERNALMICROPHONE4HE
DIAGRAMSBELOWSHOWSOMECOMMONARRANGEMENTSFOREXTERNAL
MICROPHONESWITHTHE#ONFERENCE0HONE

#ONNECTIONOFAN%XTERNAL2ECORDING$EVICE/PTIONAL	
4HE6OICE#ENTER#ONFERENCE0HONEPROVIDESAN2#!JACKFORCONNECTION
OFANEXTERNALRECORDINGDEVICESUCHASATAPERECORDER	4HIS
PROVIDESACONVENIENTMEANSTORECORDATELECONFERENCEHELDWITH
THE#ONFERENCE0HONEANDTOOBTAINTHEHIGHESTQUALITYRECORDING
POSSIBLE
4HECONNECTIONFORTHEEXTERNALRECORDINGDEVICEISANAUDIO2#!
COAXIALCONNECTORLOCATEDONTHESIDEOFTHE#ONFERENCE0HONE
!NYRECORDINGDEVICECONNECTEDTOTHEPORTMUSTHAVEAN!#!
APPROVEDLINEISOLATIONDEVICEFITTED



Specifications
Conference Phone
Controls and Interface
Switches
LED indication lights
Speakerphone connections

Electrical specifications
Power
Current draw
Output of loudspeaker
Microphone sensitivity
Mechanical specifications
Speakerphone (main body)

Microphone switch to turn on
2, 3 or all 4 built-in microphones
Green LEDs (one by each active
microphone) indicates unit is on
Inputs:
RJ-45 for telephone interface cable
2 RJ-22 jacks for external mics

Tone/pulse switch to select
telephone dialing mode
4 red LEDs (one by each microphone)
indicate mute is activated
Output:
1 RCA jack for connection to
external recorder (not supplied)

15 VDC; 120 VAC adapter supplied (input 120 VAC 60 Hz, output 900mA at 15 VDC)
Standby: 110 ± 10 mA
Operation: 220 mA and above
5W at 81
4 internal microphones: -47 ± 4 dB

13.75 inch (350 mm) diameter
1 lb. 10 oz. (740 g)

Comes with 20 ft (6 m) RJ-45 cable

Telephone System Interface
Connections
Both analog and digital
Analog
Digital

Inputs:
15 VDC for power adapter
RJ-11 for telephone line
RJ-22 for telephone handset

Outputs:
RJ-45 cable to conference phone
RJ-11 for external telephone (neither
cable nor telephone supplied)
RJ-22 cable connection to handset jack

Dimensions
4.6 in. wide x 1.6 in. tall x 1 in. deep (118 x 45 x 25 mm)
Weight
1.9 oz. (53 g)
May be mounted by telephone jack
Note: Data apply for both analog and digital telephone system interfaces unless otherwise noted.

External Microphone
Connection
Microphone sensitivity
Weight

14

Comes with 70 in. (1.8 m) cable with RJ-22 connector
-47 ±4 dB
2.4 oz. (69 g)

Spracht Limited Warranty Policy
Spracht warrants it products against defects or malfunctions in material and workmanship under normal use and service, with the
exceptions stated below. This warranty lasts for one year from the original date of purchase. Coverage terminates if you sell or
otherwise transfer the product. In order to keep this warranty in effect, the product must have been handled and used as prescribed in the instructions accompanying the product.
Spracht shall (at its option) repair or replace a defective unit covered by this warranty, or shall refund the product purchase price.
Repair, replacement with a new or reconditioned unit, or refund, as provided under this warranty, is your exclusive remedy. This
warranty does not cover any damages due to accident, misuse, abuse, or negligence. Spracht shall not be liable for any incidental
or consequential damages. Some states do not allow limitation or exclusion of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. Implied warranties of merchantability and fitness for a particular purpose are limited in
duration to the duration of this warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.
To make a warranty claim, the purchaser must obtain a return authorization number from Spracht (serial number and purchase
date required), and then return the product to Spracht at purchaser’s expense. A copy of the original dated receipt or shipping
document must accompany the product. To obtain a return authorization, see “Warranty” on our Web site at www.spracht.com,
send an e-mail to info@spracht.com, or contact us at:
Spracht
Tel:
650-318-8061
Fax: 650-318-8060
2672 Bayshore Parkway, Bldg 900
Mountain View, CA 94043
USA
For repair or replacement of failed product, allow 4 to 6 weeks for processing and shipment.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Extended Warranty Coverage
Spracht offers two extended warranties for the Voice Center Conference Phone for an additional charge.
• The Spracht E-CP-3 extended warranty provides the same coverage as the Limited Warranty set forth above, but extends coverage
to a 3-year period.
• The Spracht E-CP-3+ extended warranty extends coverage to 3 years, and also offers advance replacement of a faulty product.
Spracht will provide a functioning unit within five business days (within the continental U. S.) from the issuance of the RA number;
you return the faulty product to Spracht after the replacement is received.
Under both the E-CP-3 and E-CP-3+ extended warranties, Spracht agrees to repair or replace your Voice CenterTM Conference Phone in
accordance with the terms of the Limited Warranty set forth above for a period of three years from the date of purchase. The extended
warranties do not cover preventive maintenance, and are subject to the limitations described above with respect to proper use of the
product by the purchaser. The extended warranties are not transferable and apply only to the original purchaser of the product.
An extended warranty must be purchased within 30 days of purchase, and may be purchased using a credit card for payment,
either using the registration and order form enclosed with the product, or by contacting Spracht at 650-318-8061 (be ready with
all information on the registration and order form)

15

16

Federal Communications Commission Statement
Note: The Voice Center Conference Phone equipment has been tested and found to comply with the limits for a Class B Digital Device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. The equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communication.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
connect the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Declaration of Compliance
The Voice Center Conference Phone complies with Part 68 and part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
REN: 0.1

17

Made in Taiwan
Rev. 8/04
SP1040
Spracht and Voice Center are trademarks of ODI.
© 2003 Spracht

SPRACHT
Tel: 650-318-8061
Fax: 650-318-8060
2672 Bayshore Parkway, Bldg 900
Mountain View, CA 94043 USA
www.spracht.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 19
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:4ab14f21-9344-4616-9461-dcd4299fd316
Producer                        : Acrobat Distiller 6.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2004:08:04 16:47:58-07:00
Create Date                     : 2004:08:04 16:47:58-07:00
Document ID                     : uuid:e75cfd3a-6106-42b2-a249-8b632da46715
Format                          : application/pdf
Title                           : SP1040_5.pdf
Creator                         : Tin Hoang
Author                          : Tin Hoang
EXIF Metadata provided by EXIF.tools

Navigation menu