Sprint Nextel Unbundled Dark Fiber Users Manual
Unbundled Dark Fiber unbundled_dark_product_fiber_guide
Unbundled Dark Fiber to the manual af6b7a50-4460-49ce-8c03-6bab9865967d
2015-02-06
: Sprint-Nextel Sprint-Nextel-Unbundled-Dark-Fiber-Users-Manual-528463 sprint-nextel-unbundled-dark-fiber-users-manual-528463 sprint-nextel pdf
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
Unbundled Dark Fiber Product Guide Copyright © Sprint 2002. All rights reserved. The Sprint Brand, the Sprint name and the diamond logo are registered trademarks of Sprint Communications Company L.P. Unbundled Dark Fiber Table of Contents Product Overview ............................................................................................................................................. 3 Product Details .................................................................................................................................................. 4 Ordering Process............................................................................................................................................... 7 Interoffice Transport Orders........................................................................................................................... 7 Administrative Section............................................................................................................................... 8 Transport Section ....................................................................................................................................... 8 Loop Orders....................................................................................................................................................... 9 Service Tab ................................................................................................................................................ 10 Loop Tab ................................................................................................................................................... 11 CLEC Tab ................................................................................................................................................. 12 Invoicing Elements ......................................................................................................................................... 12 Requirements ................................................................................................................................................... 13 Frequently Asked Questions ......................................................................................................................... 16 10/02 Version 1 Copyright 2002 Sprint Communications Company 2 Unbundled Dark Fiber Product Overview Unbundled Dark Fiber (UDF) is unlit fiber optic cable strands between two points in the Sprint network. UDF is an existing, single-continuous transmission path that terminates on a Sprint Fiber Patch Panel (FPP). UDF can be between two Sprint wire centers, between a Sprint wire center and the end-user premises or between a Sprint wire center and an appropriate Outside Plant (OSP) structure such as a digital loop carrier or a hub in a cabinet. UDF can also be provided between two OSPs or between an OSP and the end-user premises. The availability of UDF allows a Competitive Local Exchange Carrier (CLEC) to construct its facilities using existing spare Sprint optical fiber between locations. With the proper electronics, UDF offers unlimited bandwidth availability. Use of a high-speed backbone allows aggregation of lower speed traffic, which saves on plant investment. However, Sprint does not make any representations as to the transmission capability of these facilities. UDF consists of the following elements: • Interoffice Facility: This element provides a route between two existing Sprint wire centers. • Loop: This element provides a route between a Sprint wire center and end-user premises. • Subloop: This element provides a portion of an existing UDF Loop. A subloop terminating in an OSP is designated as feeder fiber. Subloop from a FPP in a remote OSP location to another remote OSP location or end-user premises is designated as distribution fiber. Unbundled Dark Fiber can also be a combination of these elements. The CLEC must submit a Bona Fide Request (BFR) for an element not listed. Sprint offers UDF via optical cross-connect or fiber jumper from the Sprint FPP to a collocated CLEC FPP. Sprint will provide UDF where it is both available and accessible for the dedicated transport and unbundled loop network elements. Additional splicing of fiber strands is not an element of this product offering, but is available on an individual case basis (ICB) from Sprint. Sprint provides UDF to a CLEC in increments of a single strand. The CLEC will be required to submit a Dark Fiber Application with the application fee to their local account manager. The application process will verify the availability of the requested route, provide price quote information and reserve the requested dark fiber route for 10 business days. For additional information to initiate the process refer to the Requirements section of this guide. 10/02 Version 1 Copyright 2002 Sprint Communications Company 3 Unbundled Dark Fiber Product Details Sprint offers Unbundled Dark Fiber in the following configurations: Sprint Central Office (CO) to Sprint Central Office Route Type 1) Central office to central office (interoffice transport) Description The CLEC must have a collocation presence at each end of the fiber route. Fiber jumpers join the Sprint fiber, terminated on a patch panel, to the CLEC. Note: Transport routing can be provided through intermediate central offices. Collocation is not required in the intermediate offices. Terminating central offices need not be in adjacent wire centers. Sprint Central Office to End-user Premises Route Type 2) Central office to an end-user premises located FPP (loop) 10/02 Version 1 Description The CLEC must have a collocation presence in the Sprint CO. Fiber jumpers join the Sprint fiber, terminated on a patch panel, to the CLEC. Copyright 2002 Sprint Communications Company 4 Unbundled Dark Fiber Product Details (Continued) Sprint Central Office to Sprint Remote Site Route Type Description 3) Central office to remote site (feeder subloop) The CLEC must have a collocation presence in the Sprint CO and the remote site. A fiber jumper connects the Sprint FPP to the CLEC FPP. Additional fiber cable and splicing will be provided on an ICB at the remote site. Sprint Remote Site to Sprint Remote Site Route Type 4) Remote to remote (distribution subloop) 10/02 Version 1 Description The CLEC must have a collocation presence in both remote sites. A fiber cable may terminate from the Sprint FPP to CLEC outside plant (OSP) facility. Copyright 2002 Sprint Communications Company 5 Unbundled Dark Fiber Product Details (Continued) Sprint Remote Site to End-user premises Route Type Description 5) Remote site to an end-user premises located FPP (distribution subloop) The CLEC must have a collocation presence at the end-user premises. A fiber jumper provided through the collocation agreement connects the Sprint FPP to the CLEC FPP. At the remote site (OSP) a fiber cable provided under ICB will connect the Sprint FPP to the CLEC facilities. Note: Sprint also provides Route Types 2, 3, 4 and 5 (above) with Interoffice Transport. 10/02 Version 1 Copyright 2002 Sprint Communications Company 6 Unbundled Dark Fiber Ordering Process UDF must be ordered via a Local Service Request (LSR) or an Access Service Request (ASR), depending on the type of route requested. Refer to Table 1 below to determine which type of order to use. Submission of a UDF firm order indicates that the CLEC agrees to pay the quoted monthly recurring and non-recurring charges. Sprint will provide the UDF route to the CLEC within 20 business days after a firm order is received from CLEC. Sprint will begin invoicing of the monthly recurring and non-recurring charges upon completion of the order. Table 1 – Order Types for Unbundled Dark Fiber Route Type Definition 1) CO to CO (interoffice transport) 2) CO to an end-user premises located FPP (loop) 3) CO to remote (feeder subloop) Dark fiber transport is between two Sprint FPPs in two separate Sprint offices. Dark fiber loop is between a Sprint FPP located in a Sprint CO and a Sprint FPP located at an end-user premises. 4) Remote to remote (distribution subloop) 5) Remote to an enduser premises located FPP (distribution subloop) Dark fiber feeder is between two Sprint FPPs - one located in a Sprint CO and one at a remote location served by that CO. Dark fiber distribution can be between Sprint FPPs at two remote locations, such as digital loop carriers. Dark fiber distribution can be between a Sprint FPP located outside a Sprint CO (e.g., remote site) and a FPP located at end-user premises. Order Type ASR LSR LSR LSR LSR Interoffice Transport Orders Route Type 1 is considered Interoffice Transport. Route Type 1 should be ordered via an ASR and submitted to the Sprint National Access Service Center (NASC). Additionally, orders may be placed in Access Request Management System (ARMS) via Sprint’s Host on Demand. The entries required for Interoffice Transport orders placed into ARMS are provided on the sample screens below. Each field should be populated with end-user specific information. 10/02 Version 1 Copyright 2002 Sprint Communications Company 7 Unbundled Dark Fiber Interoffice Transport Orders (Continued) Administrative Section Additional entries as noted in Table 2 are required in the Administrative section of the ASR. Table 2 – Administrative Entries Field Access Customer Terminal Location (ACTL) Unbundled Network Element (UNE) Request Type (REQTYP) All other fields Entry The CLEC Common Language Location Identifier (CLLI) code Y SD Complete with standard entries Figure 6 highlights the entries described above. Figure 6 – Administrative Screen ASR ADMINISTRATIVE DATA - 1 NON ACCESS Y ADMINISTRATIVE SECTION ORD NO ___________ MORE? _ ICSC MG07 PON DARKFIBEREXAMPLE VER __ NOR __ OF __ ASR NO __________________ D/T SENT 10 - 30 - 01 - 0301PM QA _ DDD 11 - 30 - 01 PROJECT ________________ RTR F CC 1811 CNO ____________ UNE Y WST _ QNAI __ QSA __ CBD __ REQTYP SD ASC-EC ____ ACT N SUP _ AFO ____ EXP _ AENG _ ALBR _ SPA TQ __ CCNA ZZZ CUST CLEC AGAUTH _ DATED __ - __ - __ LUP ___ CKR _____________________________________________________ PIU 000 PLU 100 ECCKT _____________________________________________________ UNIT _ QTY 0000004 FBA ____ FNI _____________ CFNI ____________________ PBT _ QTY _______ BAN 999 - XXX - XXXX ASG ______ ACTL HLSMMOXARS0 APOT ___________ AI _ AFG _ BIC _ BIC TEL ___ - ___ - ____ BIC ID ____________ TSC ________ FDT ______ BSA _ SPEC _______ PSL ___________ PSLI _ LTP ____ RORD _________________ RPON ________________ CCVN ______ TSP _________ - __ PPTD __ - __ - __ PFPTD __ - __ - __ WSTN ___ - ___ - ____ LA _ LADATED __ - __ - __ LANM _______________ REMARKS: APPLICATION NO. 1234HLSMMO-001 FOR UNBUNDLED DARK FIBER. Transport Section Additional entries as noted in Table 3 required in the Transport section of the ASR. Table 3 – Transport Entries Field Network Channel (NC) Network Channel Interface (NCI) Secondary NCI (SECNCI) Secondary Location (SECLOC) All other fields 10/02 Version 1 Entry LX-01QBF.LLX 01QBF.LLX E Complete with standard entries Copyright 2002 Sprint Communications Company 8 Unbundled Dark Fiber Transport Section (Continued) Figure 7 highlights the entries described above. Figure 7 – Transport Screen TRANSPORT: NC LX-- NCI 01QBF.LLX____ TLV _____ T _____ R SECNCI 01QBF.LLX___ SECTLV _____ T _____ R NSIM _ SR ___ S25 _______ ER _ SSS _ ATN ____________ TRF _ MST _ HVP _ OTC ____ ISDN SEQ __ OF __ CKLT ___________ NSL __ CFAU _ CFA _______________________________________ DIR _ CPT _____ - _____ SCFA __________________________________________ SDIR _ SECLOC E___________ MUXLOC ___________ HBAN ___ - ___ - ____ PRI ADM ___________ SEC ADM ___________ CLK _ NVC ___ PSPEED _______ LMP _ N/U _ ZLG _ BSC ETET _ CCEA ____________________________________________________________ SCCEA ____________________________________________________________ GETO _ GBTN ___ - ___ - ____ GCON _________________________ GTEL ___ - ___ - ____ - ____ CTX TEL ___ - ___ - ____ CTX LSTD NM _________________________ W1 ____________________________________ W2 _______________________________ REMARKS ___________________________________________________________ Loop Orders Route Types 2, 3, 4 and 5 are considered Loop activity. They should be ordered via an LSR and submitted to the National Exchange Access Center (NEAC). Orders for theses Route Types may be placed through Sprint’s Integrated Request Entry System (IRES). Examples of the special entry instructions for IRES described below are provided on the following pages. Entries in all other tabs within IRES are completed with standard entries. Special entry instructions apply for the CLLI code information in IRES as reflected in Table 4. Table 4 – IRES Special Entry Requirements Route Types 2, 3, 4, 5 Tab Service Field ACTL 3, 4 Service 2, 5 End User Additional Point of Termination (APOT) Address fields 10/02 Version 1 Entry Location Z, the CLLI associated with the point of interface (POI) CLLI at the CO or OSP Location A, the POI CLLI at the OSP End-user (EU) address Copyright 2002 Sprint Communications Company 9 Unbundled Dark Fiber Loop Orders (Continued) Table 5 provides the appropriate location information by Route Type. Table 5 – Route Type Information Route Type 2) Central Office to an end-user premises located FPP (loop) 3) Central Office to remote (feeder subloop) 4) Remote to remote (distribution subloop) 5) Remote to an end-user premises located FPP (distribution subloop) Location Z POI CLLI at the CO (CLLI Z) Location A End-user address POI CLLI at the CO (CLLI Z) POI CLLI at the OSP (CLLI A) POI CLLI at the OSP (CLLI A) End-user address POI CLLI at the OSP (CLLI Z) POI CLLI at the OSP (CLLI Z) Service Tab In IRES, entries are required in the ACTL and APOT fields on the Service tab when two CLLI codes are required (Route Types 3 and 4). When one CLLI code and one address are required (Route Types 2 and 5), the only field requiring an entry is the ACTL field. In addition, entries are required in the NC, NCI and SECNCI fields on the Service tab. Table 6 provides the codes for loop Route Types 2, 3, 4 and 5. Table 6 - Codes Route Type 2) Central Office to an end-user premises located FPP (loop) 3) Central Office to remote (feeder subloop) 4) Remote to remote (distribution subloop) 5) Remote to an end-user premises located FPP (distribution subloop) NC LX-- NCI 01QBF.LLX SECNCI 01FCF.X LX-LX-LX-- 01QBF.LLX 01QEF.X 01QEF.X 01QEF.X 01QEF.X 01FCF.X Figure 8 illustrates the required entries described above. The remaining fields highlighted on the Service tab should be completed with standard entries. 10/02 Version 1 Copyright 2002 Sprint Communications Company 10 Unbundled Dark Fiber Service Tab (Continued) Figure 8 – Service Tab Loop Tab The CLEC should enter the appropriate cable identification and channel pair in the Loop tab as shown in Figure 9. Figure 9 – Loop Tab 10/02 Version 1 Copyright 2002 Sprint Communications Company 11 Unbundled Dark Fiber CLEC Tab The CLEC should enter the application number as shown on the Dark Fiber Application (DFA) confirmation on the CLEC Tab in the Remarks to Sprint section as shown in Figure 10. Figure 10 – CLEC Tab Invoicing Elements UDF is provided using loop and interoffice (transport) invoicing elements. Pricing is included in the interconnection agreement or its addenda. No volume or term discount plans are provided. Invoicing Elements may include: • • • • Unbundled Dark Fiber Loop Unbundled Dark Fiber Interoffice Transport Unbundled Dark Fiber Local Feeder (office to remote subloop) Unbundled Dark Fiber Local Distribution (remote to remote or remote to end-user subloop) Other invoice components include non-recurring charges for initial installation, monthly and nonrecurring charges for fiber patch cords, fiber patch panels and end-to-end testing after initial installation. Special construction charges may apply for central office interconnection cabling and fiber patch cords. 10/02 Version 1 Copyright 2002 Sprint Communications Company 12 Unbundled Dark Fiber Requirements CLECs must have UDF language and rates identified in their Master Interconnection and Resale Agreement prior to submitting a Sprint Dark Fiber Application (DFA) and the appropriate application fee. Sprint will provide access to the CLEC for accessible and available UDF facilities. The CLEC is responsible for obtaining and connecting electronic facilities to the UDF. Sprint will not remove, and CLEC will be permitted to use, any regenerating equipment in existing facilities. The CLEC must have an established collocation with an FPP at the end points of the UDF transport facility, at the serving wire center of the UDF loop or at the feeder subloop. No collocation is required at intermediate wire centers where the fiber route passes through that wire center. The CLEC may request UDF prior to collocation build. The CLEC must complete a Sprint DFA in order to determine availability of the requested route. Once verification of availability is obtained, the CLEC has 10 business days to submit a firm order for that route. Once the UDF route is complete, all recurring and non-recurring charges will be applied. Use restrictions applied for leased dark fiber are consistent with those for loop, transport and EELs. Sprint will reserve a minimum of four fibers per sheath and up to a maximum of 12 for testing and maintenance use by Sprint. In addition, Sprint reserves the right to take back fiber to meet Sprint’s carrier of last resort obligations. Refer to the Master Interconnection Agreement for details. The CLEC will be required to submit a DFA prior to submitting a firm order for UDF. Refer to Figure 11 for a sample application. The CLEC initiates the process by submitting an application for UDF with the appropriate application fee to the local account manager. The purpose of the application is to verify that the requested UDF route is available and to provide pricing of the route prior to ordering. Within 20 business days of receipt of the DFA, Sprint will provide the CLEC with an analysis and response regarding route availability and cost details. Refer to Figure 12 for a sample analysis and response. If UDF is available, the CLEC is required to notify Sprint of acceptance or rejection of the price quote. Acceptance must be via a firm order, within 10 business days of receipt of the quote. Sprint will reserve the requested dark fiber for the CLEC during those 10 business days. If, however, the CLEC does not submit a firm order within 10 business days, the fiber reservation expires. Additionally, if the CLEC has not accepted the price quote after 10 business days of receipt, the CLEC must submit another DFA and application fee. 10/02 Version 1 Copyright 2002 Sprint Communications Company 13 Unbundled Dark Fiber Requirements (Continued) Figure 11 – Sample Dark Fiber Application DARK FIBER APPLICATION Customer Provided Information: CLEC Name: ***CLEC Name*** 4 Requested # of Fibers: CLLI A: 11 Character CLLI CLLI Z: 11 Character CLLI OR OR Customer Address 1: Address 2: City: State: Zip: Customer Address 1: Address 2: City: State: Zip: CLEC Remarks: Inquiry is for 4 fibers from CLLI A to CLLI Sprint Provided Information: FSM Name: *Application Number: Date Received: Date Returned to CLEC: State/Territory (See fee below): Requested Fiber Route Available: Reason (If Unavailable): Type of Firm Order Required: (If completed quote results in an order) MO Yes Not Applicable ASR * NOTE: Any firm order (ASR or LSR as specified in the completed application) resulting from this application MUST include the Application Number shown above in the remarks section of the ASR or LSR. Terms and Conditions: This Dark Fiber Application will not be processed unless the above information is complete, and it is submitted with a check in the amount shown at the right, for the state and territory indicated above. $267.32 Upon providing the pricing and availability for the requested Dark Fiber route, Sprint will reserve the fiber route (if available) for up to 10 business days pending the receipt of a firm order. Beyond 10 business days, if an ASR/LSR has not been received, a new application and fee will be required. The pricing information outlined in this quote is applicable until the expiration or mutually agreed upon amendment of the interconnection agreement. 10/02 Version 1 Copyright 2002 Sprint Communications Company 14 Unbundled Dark Fiber Requirements (Continued) Figure 12 provides an example of a Sprint analysis and response prepared for cost details for a requested dark fiber route. Figure 12 – Cost Details Example Cost Details For Dark Fiber Route Requested Non Recurring Charges USOC Loop NRCs: Patch Cord Inst Co Interconnection Research Special Const. Pigtail Transport End-to-end Testing Other Subtotal: Quantity Price Total 1 $27.8900 $27.89 1 $63.1200 $63.12 DFLOP $91.01 DFINO $0.00 Interoffice NRCs: Patch Cord Inst Co Interconnection Research Special Const. Pigtail Transport End-to-end Testing Other Subtotal: Total NRC: Monthly Recurring Charges Loop MRCs: Feeder Distribution Patch Panel Patch Cord Subtotal: $91.01 USOC Price Total 2 $189.0000 $378.00 2 2 $0.7000 $0.8600 $1.40 $1.72 $381.12 147,660 $0.0076 $1,122.20 Quantity DFLOP Interoffice MRCs: Interoffice Patch Panel Patch Cord Subtotal: DFINO Total MRC: 10/02 Version 1 Copyright 2002 Sprint Communications Company $1,122.20 $1,503.32 15 Unbundled Dark Fiber Frequently Asked Questions Number 1 2 3 4 5 5 10/02 Version 1 Question Answer Does Sprint UDF require collocation? Yes. UDF requires collocation at each Sprint CO or OSP facility where UDF is terminated. Where is UDF available? UDF route availability is determined through the Dark Fiber Application process based on route end points and strand quantities requested. Can UDF be provided where fiber is UDF is provided only where facilities are not accessible? both available and accessible. Any other requested arrangements must be submitted via a BFR. What are other considerations for UDF terminates at a Sprint FPP. Additional UDF? fiber cable and necessary splicing for connecting to the CLEC facilities will be provided as requested under ICB at the remote site. For that reason, an ICB request must be made for connectivity beyond the physical UDF termination. UDF service is priced using distance-sensitive rate elements. These distances are determined using actual footage. For this reason, the actual physical length of the route, not airline mileage, determines UDF prices. What testing is performed? Sprint will provide end-to-end testing for UDF routes during the firm order provisioning process. Sprint does not make any representation as to the transmission capability of these facilities. Who should be contacted if additional The local account manager should be information is needed? contacted for additional information. Copyright 2002 Sprint Communications Company 16
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2002:11:07 13:21:31 Producer : Acrobat Distiller 4.05 for Windows Modify Date : 2002:11:07 13:48:39-06:00 Page Count : 16EXIF Metadata provided by EXIF.tools