Standard Industrie REWCASEV RECEIVER FOR AIRCHOC WIRELESS APPLICATION User Manual NOTREW US F1
Standard Industrie RECEIVER FOR AIRCHOC WIRELESS APPLICATION NOTREW US F1
User Manual
USER MANUEL NOTREW-US Produced on: December 6th, 2012 Checked on: By: DESIGN OFFICE By: BOISLEUX.M Revision Level: F1 Date: December 6th, 2012 Signature: HEAD OFFICE- Standard Industrie : 139-141 rue du Luxembourg-BP50207 59054 ROUBAIX CEDEX 1- FRANCE +33 (0)3 20 28 32 32 / @ : info@standard-industrie.com NOTREW-US.doc December 6th, 2012 CONTENTS 2-1 3-1 3-2 Principle of Airchoc Wireless Receiver unit characteristics Explanation of the symbol on the label Receiver unit Batteries Recommandation Device Recycling (environment) Warranty Wireless AIRCHOC receiver unit start-up Instructions NOTREW-US.doc page 3 page 4 Page 4 page 4 page 4 page 4 page 4 page 5 page 7 December 6th, 2012 1- Principle of Airchoc Wireless NOTREW-US.doc December 6th, 2012 2- Receiver unit characteristics Material : ABS V0 + Aluminum Dimensions : 100 x 114 x 83 mm Weight: 195 g without batteries Supply voltage: 2 x 3,6Vdc Service temperature : - 20 to +70°C Humidity : no more than 80% Max altitude : e.g up to 2000 m Pollution degree : Equipped with an 915 MHz RF module 2-1 Explanation of the symbol on the label : Direct current This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 3-Receiver Unit Batteries You must use only our batteries, Standard Industrie reference: BATACW Voltage : 7.2V-13Ah (2 x 3.6Vdc) Type : Lithium-ion non rechargeable Service temperature : - 20 to +85°C Max. storage temperature: 30°C Weight : 240 g for both 3-1.Recommendation Do not recharge, short-circuit, dispose of in fire, expose to temperatures greater than 100°C, immerse, or alter its shape. Any one of these actions may damage the battery, or cause it to combust or explode. Store in a dry place at constant temperature. Attention : it is forbidden to clean the receiver in the high-pressure water. The protection is impaired if equipment is used in a manner not specified by the manufacturer. 3-2. Device Recycling (environment) At the end of the batteries’, receiver units’, or Control panel’s service life, you must not dispose of these produces with ordinary household waste. They must be disposed of at an electrical and electronic device recycling point. Comply with applicable regulations in your country. 4. Warranty The warranty does not cover damage caused by external factors such as lightning, flooding, and fire. No warranty shall apply if the device was repaired or modified by the purchaser or if its serial number has been modified, removed, or rendered illegible. Comply with the instructions for use contained in the manual. NOTREW-US.doc December 6th, 2012 5- WIRELESS AIRCHOC RECEIVER UNIT START-UP Use a flat screwdriver with a max. blade thickness of 0.5. Remove the screw Open the cover CONNECT THE BATTERIES Attach the battery connectors to the device. Direction is unimportant. The batteries must be identical. Press on the connectors until you hear a click CLOSE THE COVER Find the MAC* address 4 characters *The MAC address will be used when registering the Airchoc and for communications between the Control panel and the receiver unit NOTREW-US.doc December 6th, 2012 ATTACH THE RECEIVER UNIT HOUSING TO THE SOLENOID VALVE Ensure than the manual solenoid valve control is correctly positioned in relation to the oblong hole The housing must abut the base TIGHTEN THE HOUSING TO THE SOLENOID VALVE Compress the cover until you are in front of the screw hole. The screw will tighten the housing through the solenoid valve NOTREW-US.doc December 6th, 2012 6 – Instructions Changes or modifications not expressly approved by Standard Industrie could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC’s radiation exposure limits set forth for an uncontrolled environment under the following conditions : 1. This equipment should be installed and operated such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and user’s/nearby person’s body at all times. 2. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. NOTREW-US.doc December 6th, 2012
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Berthaud Create Date : 2013:06:10 14:07:13+02:00 Modify Date : 2013:06:10 14:07:13+02:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : Microsoft Word - NOTREW-US-F1 Creator : Berthaud Producer : Acrobat Distiller 10.0.0 (Windows) Document ID : uuid:c1a20468-8e3b-4ce7-9109-5d18e2f20109 Instance ID : uuid:52effcc8-32c8-4366-9345-bc8df8658b20 Page Count : 7EXIF Metadata provided by EXIF.tools