Stanley Black and Decker 1950217 Wireless Vacuum Gauge User Manual hilmor WirelessVacuumGauge indd

Stanley Black & Decker Wireless Vacuum Gauge hilmor WirelessVacuumGauge indd

Manual

Download: Stanley Black and Decker 1950217 Wireless Vacuum Gauge User Manual hilmor WirelessVacuumGauge indd
Mirror Download [FCC.gov]Stanley Black and Decker 1950217 Wireless Vacuum Gauge User Manual hilmor WirelessVacuumGauge indd
Document ID3714799
Application IDv1aLqEdtlE8tCF/kNMAfOQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize113.68kB (1421018 bits)
Date Submitted2018-01-15 00:00:00
Date Available2018-01-18 00:00:00
Creation Date2017-07-14 11:41:59
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2017-07-14 11:42:01
Document Titlehilmor_WirelessVacuumGauge.indd
Document CreatorAdobe InDesign CC 2017 (Macintosh)

Wireless
Vacuum Gauge
Operation and Maintenance Instructions
Model
1950217
TABLE OF CONTENTS
Introduction.........................................................................................................2
Safety & Limited Warranty.............................................................................3
Certifications.......................................................................................................4
Quick Start Guide...............................................................................................5
Wireless Vacuum Gauge Components......................................................6
Screen & Button Layouts................................................................................ 7
Technical Specifications.................................................................................8
Operating Instructions.............................................................................. 9-10
Advanced Setting............................................................................................. 11
Maintenance...................................................................................................... 12
Troubleshooting............................................................................................... 13
1-800-628-8810
INTRODUCTION
It is important to read the entire instruction manual carefully
for a complete understanding of the hilmor® Wireless Vacuum
Gauge features, limitations, and specifications before use.
hilmor® products are designed and manufactured to be used
by trained and licensed HVAC/R technicians. Incorrect use may
result in accidents, injuries or death. Refer to page 3 for safety
precautions.
The hilmor® Wireless Vacuum Gauge come with a two-year
limited warranty. Visit hilmor.com/registration to register
the gauge and activate the warranty.
The hilmor® Wireless Vacuum Gauge offers the ability
to replace the remote sensor if the original one gets
contaminated. This manual should also be referred to when
changing out the remote vacuum sensor.
The serial number can be found on the product label located on
the backside of both the Handheld Display and Remote Sensor
unit.
hilmor® Wireless Vacuum Gauge Replacement Sensor
part number: 1950219
hilmor.com
SAFETY/LIMITED
WARRANTY
SAFETY PRECAUTIONS:
• To prevent personal injury, please read the operating manual carefully and
operate only as instructed.
• Wear safety glasses, gloves and all other recommended safety gear when
		 working with refrigerants. Contact with refrigerants may cause injury. Please
		 see any warnings associated with refrigerants.
LIMITED WARRANTY:
• The hilmor® Wireless Vacuum Gauge has a 2-year limited warranty from the
purchase date.
• Product must be registered at hilmor.com/registration to
activate the warranty.
• Warranty service claims are subject to authorized inspection for product
defects. If found defective, hilmor will repair or replace registered products
within warranty period.
• Often, a returned hilmor® Wireless Vacuum Gauge can be serviced with field
maintenance, such as cleaning or replacing the remote sensor or making
minor adjustments found in the Troubleshooting section of this manual. If
the problem persists, contact hilmor Technical Support at 1-800-642-0010
or visit the hilmor website, hilmor.com.
1-800-628-8810
CERTIFICATIONS
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that
may cause undesired operation of the device.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause
undesired operation of the device.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisee aux deux conditions suivantes : (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
hilmor.com
QUICK START GUIDE
	Install batteries into Handheld Display and Remote Sensor.
Power On Handheld Display and Remote Sensor.
Handheld Display and Remote Sensor will sync automatically:
observe reading on Handheld Display.
Connect Remote Sensor to Valve Core Removal Tool or Refrigerant
Hose using Female-Female Adaptor if needed.
Pull vacuum to desired vacuum reading.
Quick Change-Out Guide for Replacement Sensor:
Purchase the hilmor® Wireless Vacuum Gauge Replacement Sensor.
Unscrew the 2 flathead screws on the back of the Remote Sensor.
Disconnect the 2 white plugs that connect the Remote Sensor
to the Replacement Sensor.
Plug in the new Replacement Sensor and gently tuck the wires into
the Remote Sensor body.
Screw the door back on to the Remote Sensor to secure the
Replacement Sensor.
Turn on the Handheld Display to automatically sync.
1-800-628-8810
WIRELESS VACUUM
GAUGE COMPONENTS
Remote Sensor
SYNC Indicator Light
Power/SYNC Button
Remote Sensor
Transmitter
Replacement Vacuum
Sensor
1/4" Female-to-Female
Adapter
1/4" Male Fitting
Handheld Display
LCD Screen
Power/Backlight
Button
Function Button
hilmor.com
Up/Down Arrows
SCREEN & BUTTON
LAYOUTS
SCREEN ICONS
Sync /
Signal Strength
check sensor
Check Sensor –
Connection Lost
check sensor
Battery Level
.8.8.8.8.8.8
.0.0.0.8
Pressure Reading
Pa kPa mTorr Torr mmHG micron
Units of Vacuum
units/min
alarm
moisture
.8.8.8. 8.8.8.8
low point
.0.0.0.8
units/min
Rate of Change
alarm
Alarm ON
moisture
Moisture Detected
high point
Alarm Set Value - Low
Alarm Set Value - High
Vacuum Progress Bar
BUTTONS
Power/Backlight Button
Function Button
Scroll Up
Scroll Down
1-800-628-8810
TECHNICAL
SPECIFICATIONS
Part Number
1950217
Replacement Sensor Part Number
1950219
Batteries
Handheld Display
AA Alkaline (3)
Remote Sensor
AAA Alkaline (3)
Wireless Range
33 Feet unobstructed
Remote Sensor Connection Fitting
1/4" male flare
Adapter Accessory
1/4" 45˚ Flare Female x 1/4" 45˚Flare Female
Acuracy
+/- 5% of reading +/- 10 microns
5 to 2,000 microns - 1 micron
2,000 to 5,000 microns - 100 microns
Resolution
5,000 to 10,000 microns - 250 microns
10,000 to ATM - 1,000 microns
Units
micron, mTorr, Torr, mmHg, mBar, kPa and Pa
Operating Temperature
-20˚C to 50˚C, -4˚F to 122˚F
Operating Humidity
Up to 75% relative humidity
Temperature Compensation Range
0˚C to 50˚C , 32˚F to 122˚F
Max Momentary Overpressure
300 PSI
Refresh Rate
Every 0.5 seconds
Set Point Alarm
User Programmable - See Advanced Settings
Power Management
Sleep Mode and configurable backlight - See Advanced
Settings
Battery Life
80 hours without backlight
Dimensions
Handheld Display
Remote Sensor
Weight
Hand Held Display
Remote Sensor Unit
hilmor.com
2.95" x 4.62" .90"
2.20" x 5.7" 1.5"
9 oz.
4.8 oz.
OPERATING
INSTRUCTIONS
BATTERIES:
1.	Use a flat head screwdriver to open the battery compartment on the
backside of both the Handheld Display and Remote Sensor.
2.	Install (3) AA Alkaline batteries into the Handheld Display according to
polarity.
3. Install (3) AAA Alkaline batteries into Remote Sensor according to 		
		polarity.
4. Re-secure Handheld Display and Remote Sensor battery doors.
POWER ON:
1.	Press power button on Handheld Display and Remote Sensor.
2.	Confirm sync has been established by observing a pressure reading on
Handheld Display and by viewing signal strength icon.
VACUUM GAUGE SYSTEM CONNECT:
Connect Remote Sensor to Valve Core Removal Tool side flare or Refrigerant
Hose using Female-Female Adaptor if needed (included).
Best Practices:
		• Minimize the number of hoses and fitting connections
		 (including manifold) to reduce leaks.
		 • Use hilmor® Valve Core Removal Tool accessory port as close as
		 possible to the system for more accurate readings.
TO CHANGE THE UNIT OF MEASURE ON THE HANDHELD DISPLAY:
1.	Hold down the Function button to open menu.
2. Press Function button to navigate to unIt submenu.
3. Press arrow button to change unit of measure: micron, mTorr, Torr,
		 mmHg, mBar, kPa and Pa.
4. Hold down Function button to save and exit.
1-800-628-8810
OPERATING
INSTRUCTIONS CONT.
Moisture Function
When the vacuum pump is blanked off to observe vacuum level and the pressure is
below 1,000 microns, moisture detection feature will activate automatically. If the
feature detects moisture the handheld unit will display the moisture icon and beep
3 times. If the pressure rises above 2,000 microns the feature is deactivated.
REPLACEMENT SENSOR
To change out the Replacement Sensor:
1. Remove the batteries from the Remote Sensor.
2. Purchase the hilmor® Wireless Vacuum Gauge
Replacement Sensor (1950219).
3. Unscrew the 2 flathead screws on the back of
the Remote Sensor to remove the door.
Note - these are captive screws, designed so
that they cannot fall out and be lost.
4. Gently remove the replaceable sensor from the
Remote Sensor housing and disconnect the
wires.
5. Plug the new Replacement Sensor in by
carefully connecting the male ends of the white
plugs to the female white plugs on the Remote
Sensor Transmitter. Gently tuck the colored
wires inside of the Remote Sensor body.
6. Re-attach the 2 flathead screws to secure the
Replacement Sensor.
7. The Replacement Sensor has been precalibrated by hilmor, so it does not need any
calibration.
8. Make sure the Handheld Display is powered on
and the new Remote Sensor should auto-sync.
10
hilmor.com
ADVANCED
SETTINGS
High And Low Pressure Point Alarms
To set high and low alarm values:
1. Hold down Function button to open menu.
2. Press Function button to navigate to H Po or L Po submenu.
3. Press arrow button to scroll through desired alarm.
4. Hold down Function button to save and exit.
Backlight
To adjust backlight settings:
1. Hold down Function button to open menu.
2. Press Function button to scroll to the BL submenu.
3. Use arrow buttons to select backlight condition: ON, 1 minute, 5 minute,
10 minute, or OFF.
4. Hold down Function button to save and exit.
5. Note – while the backlight is ON, press the SYNC button to toggle on or off
from the home screen.
Sound
To turn sound on/off:
1. Hold down Function button to open menu.
2. Press Function button to scroll to the BEEP submenu.
3. Use arrow buttons to select ON or OFF.
4. Hold down Function button to save and exit.
1-800-628-8810
11
MAINTENANCE
Battery Replacement: Replace batteries as needed. Battery indicator will show when
level is low. Connection between Handheld Display and Remote Sensor may also be
lost when battery level is low.
Cleaning the Sensor area:
1. Remove batteries from the Remote Sensor unit.
2. Use tweezers to carefully remove the fabric filter element.
3. Fill the opening halfway with denatured alcohol.
4. Cover the opening and shake Remote Sensor unit for about 15 to 30
seconds, allowing the alcohol to clean the sensor.
5. Dry the sensor cavity by draining onto clean cloth.
6. Repeat process at least three times for best results.
7. Re-install batteries.
Notes:
Do not attempt to clean with cotton swab or other similar products.
After contamination, cleaning the vacuum gauge sensor using the above
procedure may improve sensor accuracy but, for most accurate reading,
replace suspect sensors.
12
hilmor.com
TROUBLESHOOTING
Issue
Failure to
Achieve
Proper
Vacuum
No
Measurements
displaying on
Handheld
Erratic
Potential Cause
Solution
One of the unused inlet fitting
caps is loose
Tighten all caps securely
O-Rings on Hoses, Vacuum
Pump or Adapter is damaged
Replace O-Rings
Insufficient or Contaminated
Oil
Add new hilmor vacuum
pump oil to proper level
System Leak
Pressure check the system
for leaks
Vacuum Pump performance
issue
Choose the correct CFM
and vacuum pump for the
system
Contaminated or Damaged
Sensor
Clean or replace remote
sensor
Power issue
Restart Handheld and
Remote Sensor
SYNC Lost - Remote Sensor
will flash quickly & handheld
"No SYNC" icon is displayed
Ensure remote sensor &
handheld are within 33ft.
Range unobstructed. If this
does not solve the problem,
replace batteries
Low Battery - LED indicator
will flash
Replace Batteries
Contaminated or Damaged
Sensor
Check sensor filter for
discoloration. Clean or
replace if necessary
Sensor damaged from overpressurization
Replace remote sensor
Readings
If these procedures do not correct the issue, contact your nearest hilmor
distributor or call hilmor® Technical Support at 1-800-642-0010
1-800-628-8810
13
hilmor.com + 1-800-628-8810
©2017 hilmor

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c138 79.159824, 2016/09/14-01:09:01
Create Date                     : 2017:07:14 11:41:59-04:00
Metadata Date                   : 2017:07:14 11:42:01-04:00
Modify Date                     : 2017:07:14 11:42:01-04:00
Creator Tool                    : Adobe InDesign CC 2017 (Macintosh)
Instance ID                     : uuid:e8c8e0f1-cbd2-0045-acc6-a69738633d57
Original Document ID            : xmp.did:754f3a7a-2a37-4446-99d5-7e9408a4f03e
Document ID                     : xmp.id:d9ce2824-a858-41e9-87d7-31e0c6932d72
Rendition Class                 : proof:pdf
Version ID                      : 1
Derived From Instance ID        : xmp.iid:ca61ffd7-8128-4d42-9f45-a8e62173224d
Derived From Document ID        : xmp.did:0cd34704-1d19-4e35-af8d-5a1a000546b3
Derived From Original Document ID: xmp.did:754f3a7a-2a37-4446-99d5-7e9408a4f03e
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Macintosh)
History Changed                 : /
History When                    : 2017:07:14 11:41:59-04:00
Format                          : application/pdf
Title                           : hilmor_WirelessVacuumGauge.indd
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
GTS PDFX Version                : PDF/X-4
Page Count                      : 16
Creator                         : Adobe InDesign CC 2017 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YJ71950217

Navigation menu