Star Solutions M800-1 iPA-CDMA 1X Bi-directional Amplifier User Manual iPA

Star Solutions International Inc iPA-CDMA 1X Bi-directional Amplifier iPA

USERS MANUAL

Download: Star Solutions M800-1 iPA-CDMA 1X Bi-directional Amplifier User Manual iPA
Mirror Download [FCC.gov]Star Solutions M800-1 iPA-CDMA 1X Bi-directional Amplifier User Manual iPA
Document ID543548
Application IDPJKrczqdeYKFusN5bMIX2g==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.36kB (341973 bits)
Date Submitted2005-05-19 00:00:00
Date Available2005-05-19 00:00:00
Creation Date2005-05-09 13:19:03
Producing SoftwareAcrobat PDFWriter 4.0 for Windows
Document Lastmod0000-00-00 00:00:00
Document TitleiPA.PDF
Document CreatorMicrosoft Word
Document Author: Rob Stirling

MovingMedia® 2000
iCell CDMA2000 1X
iPA 800 MHz
Bi-directional Amplifier
BASIC INSTALLATION GUIDE
RELEASE 4.5
DRAFT 0.1
PART NUMBER NXX0306XXX
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 1 of 13
Copyright © 2004 UTStarcom Incorporated. All rights reserved.
Copyright © 2004, UTStarcom, Inc. All rights reserved. No part of this documentation may be reproduced in any form or by
any means or used to make any derivative work (such as translation, transformation, or adaptation) without prior written
permission from UTStarcom, Inc.
UTStarcom, Inc. reserves the right to revise this documentation and to make changes in content from time to time without
obligation on the part of UTStarcom, Inc. to provide notification of such revision or change.
UTStarcom, Inc. provides this documentation without warranty of any kind, either implied or expressed, including, but not
limited to, the implied warranties of merchantability and fitness for a particular purpose. UTStarcom may make improvements
or changes in the product(s) and/or the program(s) described in this documentation at any time.
UNITED STATES GOVERNMENT LEGENDS:
If you are a United States government agency, then this documentation and the software described herein are provided to
you subject to the following:
United States Government Legend: All technical data and computer software is commercial in nature and developed solely
at private expense. Software is delivered as Commercial Computer Software as defined in DFARS 252.227-7014 (June
1995) or as a commercial item as defined in FAR 2.101(a) and as such is provided with only such rights as are provided in
UTStarcom's standard commercial license for the Software. Technical data is provided with limited rights only as provided in
DFAR 252.227-7015 (November 1995) or FAR 52.227-14 (June 1987), whichever is applicable. You agree not to remove or
deface any portion of any legend provided on any licensed program or documentation contained in, or delivered to you in
conjunction with, this User Guide.
UTStarcom, the UTStarcom logo and MovingMedia 2000 are registered trademarks of UTStarcom, Inc. and its subsidiaries.
Other brand and product names may be registered trademarks or trademarks of their respective holders.
Regulatory
This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received including interference that may cause undesired operation.
Where appropriate, the use of the equipment is subject to the following conditions:
CAUTION! Unauthorized modifications or changes not expressly approved by UTStarcom could void compliance with
regulatory rules, and thereby your authority to use this equipment.
WARNING (EMI) - United States FCC Information - This equipment has been tested and found to comply with the
limits pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in an appropriate installation. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions, may cause harmful interference to radio communication.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON,
the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician
To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the
antenna cannot exceed ____ Watts EIRP and the antenna must be permanently installed in a fixed location that
provides at least ____ cm of separation from all persons.
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 2 of 13
1 PREFACE
1.1 Objective
This document provides installation and configuration instructions for setting up an iCellCDMA2000 1X iPA system. It covers physical installation only.
1.2 Organization
The major sections of this guide are as follows:
Table 1-1: Organization Table
Chapter
Title
Description
Chapter 1
Preface
Introduction to the Installation Guide.
Chapter 2
iCell System Description
Describes the System components
Chapter 3
iPA Physical Installation
Provides mechanical installation
and wiring instructions.
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 3 of 13
1.3 Reference Documents
The following table summarizes the applicable reference documents.
Table 1-2: Reference Documents
Ref.
Title
User Manual Pico BTS
iCell CDMA2000 1X Alarms and Statistics
iCell CDMA2000 1X Configuration Guide
Number
1.4 Acronyms and Abbreviations
The following table summarizes the acronyms and abbreviations used throughout the
document.
Table 1 -3: Acronyms and Abbreviations
1PPS
One Pulse Per Second
AAA
Authentication, Authorization, and Accounting function
Abis
Protocol interface between sBSC and BTS
ASN.1
The language used to define the MIB of the NE
EM
Element Manager
GPS
Global Positioning System
HLR
Home Location Register
sBSC
iCell Base Station Controller
BTS
iCell Base Station Transceiver Subsystem
BSS
Base Station Subsystem (BSC+BTS)
iMB
iCell Main Board
IOS
Inter-Operability Standard; A-Interface between sBSC and MSC
IP
Internet Protocol
iPA
iCell Power Amplifier
MIB
Management Information Base
MS
Mobile Station (phone)
MSC
Mobile Switching Center
NE
Network Element or agent
NOC
Network Operations Center
OID
Object Identifier
OMC
Operations & Maintenance Center
PA
Power Amplifier
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 4 of 13
PDSN
PSTN
RF
SMSC
Packet Data Serving Node
Public Switch Telephone Network
Radio Frequency
Short Message Service Center
Simple Network Management Protocol
SNMP
Simple Network Timing Protocol To Be
SNTP
TBD
TCP
Defined
Transmission Control Protocol
Time Of Day
TOD
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 5 of 13
2 iCell MACRO SYSTEM DESCRIPTION
This chapter provides an iCell system description.
2.1 Introduction
The iCell is an IP-based solution for CDMA2000 1X radio access networks.
The iCell system provides the overall functionality of a CDMA2000 1X Base station
transceiver subsystem (BTS) and soft base station controller (sBSC), providing an IP
over Ethernet interface to the core network. For Macro coverage small footprint iPA Bidirectional amplifier is added to the basic BTS configuration. Figure 2-1 shows the
system architecture.
Figure 2-1: iCell Macro BSS using iPA
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 6 of 13
2.2 iPA System Components
The iPA is only used when the iCell is installed in a 19" rack-mounted configuration. The
iPA is a three sector bi-directional amplifier that incorporates:
A high power amplifier (HPA)
Two low noise amplifiers (LNA) for receive diversity, frequency
conversion and selectivity capabilities (for each sector).
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 7 of 13
3 BTS PHYSICAL INSTALLATION
3.1 General
This chapter provides physical installation and wiring instructions for the iPA.
3.2 Unpacking
Upon receipt of, and before opening the iCell packages, inspect for any damage that
might have occurred during shipping. If the package shows any signs of external
damage or rough handling, notify your carrier's representative.
CAUTION
All modules are susceptible to electrostatic discharge (ESD) even while
installed. Take the necessary precautions to minimize electrostatic damage
while handling modules.
Carefully remove all parts and hardware out of the
packages. Carry out a full inventory before installation
procedure starts.
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 8 of 13
3.3.1 BTS 19" Rack Mount
See Figure 3-1 and Figure 3-2.
1. Insert the BTS 1X 19" unit into a 19" rack. Secure with four NF10 screws.
2. Connect BTS 19" Rack Mount according to paragraph 3.4.2.
Figure 3-1: BTS 19' Rack Mont Rear View
Figure 3.2: BTS 19” Rack Mount Front View
Figure 3.3: iPA Front View
Figure 3.4: iPA Rear View (AC input Power) (-48v DC version also available)
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 9 of 13
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 10 of 13
3.4 Interface Connections
3.4.1 BTS and iPA Interface Connections
Verify that the power switch is off on both the iPA and the BTS unit
3.4.2 BTS to iPA Interface Connection
Figure 3-1 illustrates the wiring diagram of the BTS and iPA for Macro coverage.
Table 3-1 provides the wiring parameters.
Figure 3.1: BTS and iPA wiring diagram
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 11 of 13
iWAN Installation Guide
Table 3-1: iBTS 19" Wiring
iBTS
Destination
Name
Type
Cable
MCN
S3 RX1
SMA
45-89330-M3
iPA RX3 Diversity
SMA
S3 TX/RX0
SMA
45-89330-M3
iPA TX/RX3
Diversity
SMA
S2RX2
SMA
45-89330-M3
iPA RX2Diversity
SMA
S2 TX/RX0
SMA
45-89330-M3
iPA TX/RX2
Diversity
SMA
S1 RX2
SMA
45-89330-M3
iPA
RX1 Diversity
SMA
S1 TX/RX0
SMA
45-89330-M3
iPA
TX/RX1 Diversity
SMA
iPA 1
RJ45S
45-89331-M2
iPA Com 1
DB-9
iPA 2
RJ45S
45-89331-M2
iPA Com 2
DB-9
iPA 3
RJ45S
45-89331-M2
iPA Com 3
DB-9
19.2 MHz
SMA
45-89330-M3
iPA SMA
19.2
MHz
Pri Eth
RJ45S
Standard CAT5
Ethernet Switch
RJ45
Console
RJ45S
45-89331-M2
PC
DB9
GPS TOD
RJ45S
45-89332-M3
GPS DB9 Serial
DB9
1 PPS IN 1
SMA
GPS 1 PPS
BNC
AC Power
Power
Supply
Switching
Name
Type
363-06097-0015
or
363-02155-0002
External Source
Power
NOTE
All SMA connectors that are not connected should be terminated.
3-9
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 12 of 13
3.4.2.1 Connecting to iPA for three sector case:
To Connect the iBTS to the iPA:
Connect the iBTS iPA 1 RJ-45 connector to the iPA COM 1 DB-9
connector with cable MCN 45-89330-M3.
Connect the iBTS iPA 2 RJ-45 connector to the iPA COM 2 DB-9
connector with cable MCN 45-89330-M3.
Connect the iBTS iPA 3 RJ-45 connector to the iPA COM 3 DB-9
connector with cable MCN 45-89330-M3.
Connect the iBTS S1 RX1 SMA Connector to the iPA RX1 Diversity SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS S1 TX/RX0 SMA Connector to the iPA TX/RX1 SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS S2 RX1 SMA Connector to the iPA RX2 Diversity SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS S2 TX/RX0 SMA Connector to the iPA TX/RX2 SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS S3 RX1 SMA Connector to the iPA RX3 Diversity SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS S3 TX/RX0 SMA Connector to the iPA TX/RX3 SMA
connector with cable MCN 45-89331-M2.
Connect the iBTS 19.2 MHz SMA connector to iPA 19.2 MHz SMA
Connector with cable MCN 45-89331-M2.
3.4.2.2 Miscellaneous Connections for both iPA and BTS units
To connect the remainder connections:
• For AC Rack mount version, just connect the AC cord to 110 or 220 V AC
supply.
• For DC Rack Mount version, make sure the main rack breaker is off and the
BTS power switch is in the off position. Connect the –48v wire as indicated
on the rear of the unit marked “–“ or “–48v” and the positive (Bat. Rtn) wire
to the terminal marked “+” or Bat Return.
The BTS and iPA are now ready for configuration. Refer to iCell CDMA2000 1X Configuration
Guide.
MovingMedia 2000 iCell Macro with iPA Installation Guide
Page 13 of 13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 13
Creator                         : Microsoft Word
Create Date                     : 2005:05:09 13:19:03
Title                           : iPA.PDF
Author                          : Rob Stirling
Producer                        : Acrobat PDFWriter 4.0 for Windows
EXIF Metadata provided by EXIF.tools
FCC ID Filing: S52M800-1

Navigation menu