Strata Proximity Systems SPS-USZON Mining Safety Proximity Transmitter User Manual Underground PAD Users Manual

Strata Proximity Systems LLC Mining Safety Proximity Transmitter Underground PAD Users Manual

manual

Download: Strata Proximity Systems SPS-USZON Mining Safety Proximity Transmitter User Manual Underground PAD Users Manual
Mirror Download [FCC.gov]Strata Proximity Systems SPS-USZON Mining Safety Proximity Transmitter User Manual Underground PAD Users Manual
Document ID1622285
Application IDPCdSoJmV5S5EHfwpxop3nw==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize71.93kB (899086 bits)
Date Submitted2012-01-17 00:00:00
Date Available2012-01-18 00:00:00
Creation Date2011-12-19 14:39:14
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2011-12-19 14:39:14
Document TitleUnderground PAD Users Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Tom Michaud

2011
Strata Proximity Systems
Underground Silent Zone Generator
Users Manual v1.0
Strata Proximity Systems, LLC
1769 Jeff Road
Huntsville, AL 35806
1.800.691.6601
Strata Proximity Systems Underground Silent Zone Generator Users Manual v1.0
Confidential
Confidential and Proprietary
December 12,
2011
Table of Contents
Overview .............................................................................................................................3
1.1
Theory of Operation ......................................................................................................3
1.2
Frequency of Operation ................................................................................................3
1.3
Label Information..........................................................................................................3
1.4
FCC Information ............................................................................................................4
Operation ............................................................................................................................5
2.1
Installation Information ................................................................................................5
2.1.1
Interoperability Warning ........................................................................................5
2.2
Charging ........................................................................................................................5
2.3
Alerts ............................................................................................................................5
2.4
Maintenance .................................................................................................................6
Warranty .............................................................................................................................6
Revision History ...................................................................................................................6
4.1
Version 1.0 – December 12, 2011..................................................................................6
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 2 of 6
Strata Proximity Systems Underground Silent Zone Generator Users Manual v1.0
Confidential
Confidential and Proprietary
December 12,
2011
Overview
The Underground Silent Zone Generator is part of a complete HazardAvert™ Proximity
Detection System from Strata Proximity Systems which provides warnings to both individuals
and to machinery to alert them that the individual has entered too close to an operating piece
of equipment and is in a dangerous situation. The Underground Silent Zone Generator is
mounted on a vehicle or piece of machinery and is connected by an interface cable to an
Underground controller. The Underground Silent Zone Generator is mounted on the vehicle or
machinery in an area near where the operator would normally be while operating the
machinery.
1.1
Theory of Operation
The function of the Underground Silent Zone Generator is:

To transmit a 73 kHz “Silent Zone” field around a small portion of the vehicle or piece of
machinery in which the operator is allowed to work or enter as part of his normal activities.
The Underground Silent Zone Generator is connected to a HazardAvert™ Underground
Controller which generates a 73 kHz signal for creating a Silent Zone around the area of a
machine where the operator is located. This 73 kHz signal is connected to the Silent Zone
Generator via a wire bundle. Inside the Underground Silent Zone Generator is a wire/ferrite
radiator element to which the 73 kHz signal is connected. The 73 kHz signal passing through this
wire/ferrite radiator element generates a “Silent Zone” electromagnetic field which
encompasses only the small area of the machine in which the operator can be during operation.
The operator is required to wear a Personal Alarm Device (PAD) which is another component of
the HazardAvert™ system which detects and responds to the presence of 73 kHz fields. As long
as the operator is within this “Silent Zone” his PAD will know he is within a defined area and not
alarm. If the operator exits this Silent Zone area, his PAD will function to alert him and other
machines equipped with the HazardAvert™ system of his proximity to dangerous conditions
due to his distance from machine or vehicle hazards.
1.2
Frequency of Operation
The Underground Silent Zone Generator will transmit on a frequency of 73 kHz.
1.3
Label Information
The Underground Silent Zone Generator label is located on the face of the unit. A picture of the
Strata label is below:
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 3 of 6
Strata Proximity Systems Underground Silent Zone Generator Users Manual v1.0
Confidential
Confidential and Proprietary
December 12,
2011
The Strata label defines the model and serial number of the Underground Silent Zone
Generator also MSHA and Commonwealth of Pennsylvania information.
1.3.1.1
MSHA Blasting Distance
MSHA has published Program Policy Letter P11-V-07 concening Two Way Communications and
Blasting Circuits.
SPS magnetic field generators produce a magnetic field that at 100 kHz or .1000 MHz does not
achieve the Critical H Field until 1.42 m with a blasting cap having a pickup area of 10 sq.
meters.
SPS magnetic field generators are safe to 1.42 m from the blasting caps. SPS does recommend
a minimum distance of 25’ as a precaution.
1.3.1.2
Pennsylvania Blasting Distance
At this date, Pennsylvania has not made a recommendation or statement concerning surface
systems.
1.4
FCC Information
The FCC ID for the Underground Silent Zone Generator is ZQ3-SPS-USZON. When configured by
Strata for underground use, the device complies with Part 15 of the FCC Rules. Operation is
subject to the following conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received including interference that may
cause undesired operation.
Any intentional or unintentional changes or modifications to the configuration of the
Underground Silent Zone Generator not specifically detailed in this document could void the
user’s authority to operate the equipment.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 4 of 6
Strata Proximity Systems Underground Silent Zone Generator Users Manual v1.0
Confidential
Confidential and Proprietary
December 12,
2011
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Operation
2.1
Installation Information
The Underground Silent Zone Generator is mounted on a vehicle or piece of machinery. Metal
near the Underground Silent Zone Generator may impact performance. After installing the
Underground Silent Zone Assembly on the machine, performance of the unit should be verified
by calibration and test.
2.1.1 Interoperability Warning
The Underground Silent Zone Generator may experience erratic responses when in very close
proximity to some electronic devices. Electrical devices may transmit an electrical field and
noise from these fields may cause interference with the Generator. A safe guideline is to keep
the Underground Silent Zone Generator at least 75 mm away from any electrical devices
included but not limited to methane monitor, radio, mobile phone, GPS, PDA, battery charger
and laptop computers.
2.2
Charging
The Underground Silent Zone Generator is directly powered from the controller board and
requires no internal battery or charging.
2.3
Alerts
The Underground Silent Zone Generator has no alert system.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 5 of 6
Strata Proximity Systems Underground Silent Zone Generator Users Manual v1.0
Confidential
Confidential and Proprietary
2.4
December 12,
2011
Maintenance
The Underground Silent Zone Generator should be regularly cleaned to reduce buildup of dust
and dirt.
Warranty
Initial system hardware components will be warranted to be free of defects for a period of one
(1) year from in service date. Subsequent component purchases will be warranted one (1) year
from receipt acknowledgement. Warranted replacement or repair is not applicable in cases of
physical damage or abuse as determined at the time of return or inspection.
Revision History
4.1
Version 1.0 – December 12, 2011
Original release. No revision history
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 6 of 6

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 6
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Underground PAD Users Manual
Author                          : Tom Michaud
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2011:12:19 14:39:14
Modify Date                     : 2011:12:19 14:39:14
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZQ3-SPS-USZON

Navigation menu