Strix Systems ACCESS-ONE-21 802.11 a/g Wireless, Mesh Type Networking Device User Manual ows hardware installation manual

Strix Systems, Inc. 802.11 a/g Wireless, Mesh Type Networking Device ows hardware installation manual

Users Manual V

Download: Strix Systems ACCESS-ONE-21 802.11 a/g Wireless, Mesh Type Networking Device User Manual ows hardware installation manual
Mirror Download [FCC.gov]Strix Systems ACCESS-ONE-21 802.11 a/g Wireless, Mesh Type Networking Device User Manual ows hardware installation manual
Document ID743852
Application ID/VJZw2OTEbnVh39dK/HRwg==
Document DescriptionUsers Manual V
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize99.29kB (1241129 bits)
Date Submitted2007-01-04 00:00:00
Date Available2007-01-04 00:00:00
Creation Date2006-04-13 10:57:41
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2006-04-13 12:08:49
Document Titleows_hardware_installation_manual.book
Document CreatorFrameMaker 6.0
Document Author: Bill Wareing

Access/One® Network
OWS Field Installation
Strix Outdoor Wireless System (OWS)
Field Installation
April 13th, 2006
210-0014-01 Rev. F
Copyright © 2003 – 2006 Strix Systems, Inc.
26610 Agoura Road
Calabasas, CA 91302
USA
http://www.strixsystems.com
OWS Field Installation
Copyright Notice
Copyright © 2003 – 2006 Strix Systems, Inc. All rights reserved. This document may not be reproduced or
disclosed in whole or in part by any means without the written consent of Strix Systems, Inc. Access/One
Network is a registered trademark of Strix Systems, Inc. All other trademarks and brand names are marks of
their respective holders.
FCC Notice
The enclosed wireless network device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation.
This wireless network device has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This wireless network device generates, uses, and radiates
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this wireless network device does cause harmful interference to radio or television
reception, which can be determined by turning the wireless network device off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
◗
Reorient or relocate the receiving antenna.
◗
Increase the separation between the wireless network device and the affected receiver.
◗
Connect the wireless network device into an outlet on a circuit different from that to which the
receiver is connected.
◗
Consult the dealer or an experienced radio/TV technician for help.
Other Notices
Industry Canada Notice
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
VCCI Notice
This is a Class B wireless network device based on the standard of the Voluntary Control Council for
Interference from Information Technology Equipment (VCCI). If this wireless network device is used near a
radio or television receiver in a domestic environment, it may cause radio interference. Install and use the
wireless network device according to the instruction manual.
European Community (EC) Directives and Conformity
This wireless network device is in conformity with the Essential Requirements of R&TTE Directive 1999/5/EC
of the European Union.
ii
OWS Field Installation
OWS Field Installation
Non-Modification Statement
Unauthorized changes or modifications to Strix devices are not permitted. Modifications to Strix devices will
void the warranty and may violate FCC regulations.
RF Exposure Requirements
To ensure compliance with FCC RF exposure requirements, the antenna used for this wireless network device
must be installed to provide a separation distance of a minimum of 2 meters (6.56 feet) or more from all
persons, and must not be co-located or operated in conjunction with any other antenna or radio transmitter.
Installers and end-users must follow these installation instructions.
Safety Warnings
This unit must be installed by a trained professional installer only. Read the following safety warnings before
commencing an installation.
General Safety Warning
Always be aware of electrical power lines!
You can be killed if any antennas come near electrical power lines. Carefully read and follow
all instructions in this manual.
By performing these installation instructions, you may be exposed to hazardous
environments and high voltage. Use caution when installing the Strix OWS product.
Electrical Power Warning
This unit must be installed by a trained professional installer only. Read the installation
instructions before you connect the wireless network device to its power source.
Lightning Activity Warning
Do not connect or disconnect cables during periods of lightning activity.
For each antenna, a surge protective device meeting IEC 61000-4-5, Level 4 or IEEE C 62.41
A3/B3 requirements must be used to prevent potential damage from very high surges (for
example, surges caused by lightning).
Explosive Device Proximity Warning
Do not operate your wireless network device near unshielded blasting caps or in an
explosive environment.
OWS Field Installation
iii
OWS Field Installation
Antenna Placement Warning
Do not locate any antenna near overhead power lines or other electric light or power
circuits, or where the antenna can come into contact with such circuits. When installing
antennas, take extreme care not to come into contact with such electrical circuits, as they
can cause serious injury or death.
For the correct installation and grounding of antennas, please refer to national and local
codes (for example, US:NFPA 70, National Electrical Code, Article 810; in Canada:
Canadian Electrical Code, Section 54).
Ground Warning
You must ALWAYS install an external grounding wire. The ground connection must be
complete before connecting power to the OWS enclosure—a simple continuity check
between the enclosure and the ground termination point can confirm this. Grounding of the
OWS must comply with National Electrical Code (NEC) requirements, unless local codes in
your area take precedence over the NEC code.
Power Cord Assembly Caution
An assembled power cord is not supplied with the OWS. The power cord must be assembled
by a professional installer, and the final assembly must comply with National Electrical Code
(NEC) requirements, unless local codes in your area take precedence over the NEC code.
Battery Caution
This product contains a non-rechargeable, non-user-serviceable lithium ion battery. Exercise
caution to avoid shorting the terminals of this device.
Consult local laws and regulations for the proper disposal of batteries in your area.
Solar Shield
A solar shield is required for any installation where the OWS product will receive direct
exposure to sunlight. Failure to install a solar shield where required may cause damage to the
product and will void its warranty. Contact your Strix authorized distributor or Strix Systems
for Solar Shield model numbers and ordering information.
iv
OWS Field Installation
OWS Field Installation
Limited Warranty
Strix Systems, Inc. (“Strix”) warrants the Access/One Indoor Wireless System (“IWS”) and Outdoor Wireless
System (“OWS”): (i) the hardware (“Hardware”) will be free of defects in materials and workmanship from the
date of shipment as set forth below and (ii) the embedded software (“Firmware”) to the Hardware and any
separately provided software product (“Software”) are provided “AS-IS” and such items will substantially
conform to their respective published product documentation (collectively the “Product”) for the periods
indicated below, commencing (as applicable) on the date of shipment.
Covered Product
IWS products
Warranty Period
12 months
(Including but not limited to the BMEx, WM11x,
NWSV-x, Antennas, AMECs, MTKIT, PSWW, SLCDT
and SLCKIT)
OWS2400/OWS3600
12 months
OWS11xx (Radio Board)/OWS-NSxx (Network Servers)
12 months
Repaired or Replacement Items
90 days, or the balance of the original
item warranty, whichever is the greater
This limited warranty extends only to the original user of the Product and such user's sole and exclusive
remedy and the entire liability of Strix, at its option, will be to repair or replace the Hardware or component
thereof and in the case of Firmware or Software Strix will make available the then available updated version of
the Firmware or Software. Notwithstanding the foregoing, in no event does Strix warrant that the Product will
operate with any software or hardware other than that provided by Strix or specified in the applicable Product
documentation, that the Product is error free or will operate without problems or interruptions, or that the,
Product will be free of vulnerability to intrusion or attack, or that the Product will satisfy any party's own
specific requirements. The repair or replacement of the Product does not include any labor or other costs
related to the subsequent installation thereof. The obligations of Strix hereunder are conditioned upon the
return of the Hardware in accordance with the Strix then-current Return Material Authorization (RMA)
procedures (please contact your authorized Strix Systems reseller for return instructions). Repair or
replacement of the defective Product or parts thereof shall neither extend nor decrease the warranty period.
Exceptions
The foregoing limited warranties of the Product do not apply if the Product (i) has been altered or modified,
except by Strix or its duly trained and authorized service provider, (ii) has not been installed, operated,
repaired, or maintained in accordance with written instructions of Strix, (iii) has been subjected to abnormal
physical or electrical stress, misuse, negligence or accident, (iv) has been operated outside of the
environmental specifications for the Product or (v) is related to configuration of customer's network beyond
that necessary to the use or installation of the Strix Products. The Strix limited Firmware or Software warranty
does not apply to Firmware or Software corrections or upgrades. Repair of Products or the supply of updated
Firmware or Software requested after the expiration of the warranty period shall be at then current Strix repair
or update charges.
OWS Field Installation
OWS Field Installation
DISCLAIMER; LIMITATION OF LIABILITY
EXCEPT FOR THE WARRANTIES SPECIFICALLY DESCRIBED HEREIN, STRIX DISCLAIMS ANY AND ALL
WARRANTIES AND GUARANTEES, EXPRESS, IMPLIED OR OTHERWISE, ARISING, WITH RESPECT TO THE
PRODUCTS OR SERVICES DELIVERED HEREUNDER, INCLUDING BUT NOT LIMITED TO THE
WARRANTY OF MERCHANTABILITY, THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND
ANY WARRANTY OF NON-INFRINGEMENT OF THE INTELLECTUAL PROPERTY RIGHTS OF ANY THIRD
PARTY. LIABILITY OF STRIX FOR LOSS UNDER THIS CONTRACT IS LIMITED TO THE TOTAL AMOUNT
PAID TO STRIX BY CUSTOMER DURING THE PREVIOUS CALENDAR YEAR. STRIX WILL HAVE NO
OBLIGATION OR LIABILITY, WHETHER ARISING IN CONTRACT (INCLUDING WARRANTY), TORT
(INCLUDING ACTIVE, PASSIVE OR IMPUTED NEGLIGENCE, STRICT LIABILITY OR PRODUCT LIABILITY)
OR OTHERWISE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT DAMAGES
INCLUDING BUT NOT LIMITED TO LOSS OF USE, LOSS OF DATA, BUSINESS INTERRUPTION, LOSS OF
REVENUE, LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION
WITH ANY OF THE PRODUCTS OR OTHER GOODS OR SERVICES FURNISHED BY STRIX UNDER THIS
AGREEMENT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
STRIXSYSTEMS® (including the design) and ACCESS/ONE® are registered trademarks of Strix Systems, Inc.
vi
OWS Field Installation
OWS Field Installation
Table of Contents
Copyright Notice .................................................................................................................................... ii
FCC Notice ............................................................................................................................................ ii
Other Notices ........................................................................................................................................ ii
Safety Warnings ....................................................................................................................................iii
General Safety Warning ..................................................................................................................iii
Electrical Power Warning ...............................................................................................................iii
Lightning Activity Warning .............................................................................................................iii
Explosive Device Proximity Warning ..............................................................................................iii
Antenna Placement Warning .......................................................................................................... iv
Ground Warning ............................................................................................................................ iv
Power Cord Assembly Caution ....................................................................................................... iv
Battery Caution ............................................................................................................................... iv
Solar Shield .................................................................................................................................... iv
Limited Warranty ................................................................................................................................... v
OWS Field Installation ................................................................................................................. 1
Theory of Operation ............................................................................................................................... 1
Important Safety Information .................................................................................................................. 1
Planning Your Installation ...................................................................................................................... 2
Local Guidelines ............................................................................................................................. 2
Site Surveys ..................................................................................................................................... 2
Power Source .................................................................................................................................. 2
Installing the OWS Enclosure ................................................................................................................. 3
Mounting the OWS on a Vertical Pole ............................................................................................. 3
Mounting the OWS on a Wall ......................................................................................................... 7
Installing Antennas ................................................................................................................................. 8
Notes About Antenna Installations ................................................................................................... 8
Maximum Power Settings for Antennas ............................................................................................ 9
Channels for IEEE 802.11b/g ..................................................................................................... 9
Channels for IEEE 802.11a ...................................................................................................... 10
Attaching an Omni Antenna Directly to the OWS Enclosure ......................................................... 12
Mounting a Directional Antenna on a Pole .................................................................................... 14
Mounting a Sectored Antenna on a Pole ........................................................................................ 16
Mounting an Omni Antenna on a Pole .......................................................................................... 19
Antenna Connector Wiring Configurations ........................................................................................... 22
OWS Field Installation
vii
OWS Field Installation
Physical Layout (Enclosure) ...........................................................................................................22
Physical Layout (Wireless Modules) ............................................................................................... 23
Routing the Antenna Cables ................................................................................................................. 23
Grounding the OWS Enclosure ............................................................................................................ 24
Configuring the Power Cord ................................................................................................................. 25
AC Wiring Configurations .............................................................................................................. 27
Connecting the Ethernet Cable ............................................................................................................. 28
Powering Up the OWS ......................................................................................................................... 30
Powering Up from an AC Power Source ........................................................................................ 30
Powering Up from a DC Power Source .......................................................................................... 30
OWS Product Specifications ................................................................................................................ 31
Appendix I: Setting the Output Power .................................................................................................. 32
Appendix II: Installing the Band Pass Filter ........................................................................................... 33
Index .......................................................................................................................................... 35
viii
OWS Field Installation
OWS Field Installation
OWS Field Installation
This field installation manual provides instructions for installing the Strix OWS 2400 and OWS 3600 products
safely and is intended for trained technical professionals. You must read the Safety Warnings on page iii
before commencing with the installation.
Theory of Operation
The Strix Systems, Access/One® Network OWS provides up to 3 independent channels of 802.11g support,
and 3 independent channels of 802.11a support through its external connections. This configuration allows
the installer to separate the client 802.11g traffic from the backhaul traffic which is carried through the
802.11a channels.
As shipped from the factory, the OWS is self-configuring and self-healing. In addition, multiple configuration
options are possible and the installer should refer to the Access/One® Network User's Guide (part number
210-0007-01) for detailed information about these configurations.
Important Safety Information
The Federal Communications Commission (FCC) with its action in ET Docket 96-8 has adopted a safety
standard for human exposure to RF electromagnetic energy emitted by FCC certified equipment. All Strix
products, including the OWS, meet the uncontrolled environmental limits found in OET-65 and ANSI
C95.1, 1991. The proper operation of this wireless device, according to the instructions found in this
manual and the associated Access/One® Network software User’s Guide, result in user exposure that is
substantially below the FCC recommended limits.
The following are guidelines to ensure safe operation of the Strix OWS product:
◗ Do not touch or move the antenna(s) while the unit is transmitting or receiving.
◗ Do not hold any component containing a radio such that the antenna is very close to or touching any
exposed parts of the body—especially the face or eyes—while transmitting.
◗ Do not operate the OWS or attempt to transmit data unless the antenna (or a 50 ohm terminator) is
connected, otherwise the wireless module(s) may be damaged.
◗ Usage in specific environments:
– Do not operate any wireless equipment near unshielded blasting caps or in an explosive
environment.
– The use of wireless devices in hazardous locations is limited to the constraints posed by the safety
directors or such environments.
– The use of wireless devices on airplanes is governed by the Federal Aviation Administration (FAA).
– The use of wireless devices in hospitals is restricted to the limits set forth by each hospital.
◗ The Strix OWS must only be used with Strix-approved components and antennas, or equivalent.
OWS Field Installation
OWS Field Installation
Planning Your Installation
To ensure safe and durable wiring, the installation of the Strix OWS must follow the appropriate electrical and
building codes. Observe the National Electrical Code (NEC) requirements, unless local codes in your area
take precedence over the NEC code.
Local Guidelines
The Strix OWS is a radio device and therefore susceptible to interference that can reduce throughput and
range. Follow these simple guidelines to optimize product performance:
◗ Install the OWS in an area where trees, buildings, and large steel structures do not obstruct radio
signals to and from the antenna(s). Direct line-of-sight operation is always best.
◗ Install the OWS away from microwave ovens or other devices operating in the 2.4 GHz range.
◗ Install the OWS away from other possible source of 2.4 GHz WLAN interference, such as cordless
phones, home surveillance equipment, frequency-hopping (FHSS) and DSSS Local Area Network
transceivers, electronic news gathering video links, radars, amateur radios, land mobile radio services,
local government sties (for example, law enforcement), fixed microwave services, local TV
transmission, and private fixed point transmitters.
Site Surveys
Due to variations in product configuration, placement, and the physical environment, each installation is
unique. Before installing the Strix OWS, we recommend that you perform a site survey to determine the
optimum placement of the product to achieve the best possible range, coverage and network performance.
Consider the following points:
◗ Data Rates—Sensitivity and range are inversely proportional to data bit rates. The maximum wireless
range is achieved at the lowest data rate. A decrease in receiver threshold sensitivity occurs as wireless
data increases.
◗ Antenna Type and Placement—Using the correct antenna configuration is a critical factor when trying
to maximize wireless range. As a general rule, the range increases in proportion to the antenna height
and gain.
◗ Physical Environment—Clear or open areas offer better wireless coverage than closed or filled areas.
The less cluttered the operating environment, the greater the range.
◗ Obstructions—A physical obstruction, such as a building or tree, can block or hinder wireless services.
Avoid placing antennas in locations where there is an obstruction between the sending and receiving
antennas.
◗ Building Materials—Wireless penetration is influenced by the building materials used in construction.
For example, drywall construction permits greater range than concrete blocks. Steel and alloy materials
can be a barrier to wireless signals.
◗ Diversity—The Strix OWS supports RX diversity, which requires two antennas.
Power Source
The Strix OWS supports both AC and DC input power.
OWS Field Installation
OWS Field Installation
Installing the OWS Enclosure
This section provides instructions for mounting the OWS enclosure.
Mounting the OWS on a Vertical Pole
Parts Required
◗ OWS enclosure.
◗ Pole.
◗ 2 vertical mounting brackets.
◗ 4 screws, for attaching the mounting brackets to the OWS enclosure.
◗ 2 U-bolt assemblies, for mounting the OWS enclosure to a standard 1 7/8 inch diameter steel pole.
◗ 2 straps, for mounting the OWS enclosure to a pole with a diameter greater than 1 7/8 inches.
Tools Required
◗ Flat blade screwdriver
◗ 7/16 inch nut wrench
◗ 5/16 inch nut driver
Mounting Brackets (x2)
1. Attach the vertical mounting
brackets (2) to the OWS
enclosure.
Screws (x4)
2. Secure the vertical mounting
brackets to the OWS enclosure
with the four screws (2 for each
bracket).
Tighten all four screws to 10–12
lbf.ft (1.38–1.66 kgf.m).
OWS Field Installation
OWS Field Installation
3. For a standard 1 7/8 inch
diameter steel pole installation,
use the 2 U-bolt assemblies to
attach the enclosure to the pole
via the vertical mounting
brackets—finger tighten only.
If installing the OWS on a wider
pole (for example, a utility pole),
go directly to Step 7—skip Steps
3 through 6.
Tip: You may find it easier to
loosely attach the U-bolts to the
brackets, then slide the
completed enclosure assembly
over the pole (instead of holding
the enclosure against the pole
and attaching each U-bolt
separately).
U-Bolt Assembly (x2)
Includes:
◗ U-bolt
◗ Washers (2)
◗ Nuts (2)
4. Adjust the OWS enclosure to the
desired position on the pole (up
and down or rotational).
OWS Field Installation
OWS Field Installation
5. Use a 7/16 inch nut wrench to
tighten the U-bolts (4 nuts) and
secure the OWS enclosure in
place.
Tighten all four nuts to 10–12
lbf.ft (1.38–1.66 kgf.m).
When tightening the U-bolts,
ensure that the bolts are not
twisted—the ends of each U-bolt
should be protruding through the
bracket evenly (the same
distance).
Tighten (4 places)
6. Check that the U-bolts are tight
and that the OWS enclosure is
securely anchored to the pole.
OWS Field Installation
OWS Field Installation
Straps (x2)
7. For poles wider than 1 7/8 inch
diameter, use two straps (hose
clamps)—not provided. Feed one
strap through each of the vertical
mounting brackets.
Recommended straps:
Type 301 SS with Type 305 SS
screw, 3.125 x 6 inches, available
from McMaster-Carr (part
number 54155K36).
8. Loosely attach the OWS
enclosure to the pole with the 2
straps.
Adjust the enclosure to the
desired position on the pole (up
and down or rotational). Use a
flat blade screwdriver or 5/16
inch nut driver to tighten both
straps to 10–12 lbf.ft (1.38–1.66
kgf.m).
OWS Field Installation
OWS Field Installation
Mounting the OWS on a Wall
Parts Required
◗ OWS enclosure.
◗ 4 nylon hangers, for mounting the OWS enclosure to a wall.
◗ 4 screws (10-32 x 0.375), for attaching the nylon hangers to the enclosure.
Tools Required
◗ Flat blade screwdriver
◗ Power drill and drill bit (if necessary)
1. Attach the 4 nylon hangers to the
OWS enclosure using the 4
screws provided.
Nylon Hanger (x4)
2. Mount the OWS enclosure to any
wall surface, ensuring that the
unit is level and secure (4 places).
If mounting the enclosure to a
masonry wall, you will need a
power drill, masonry drill bit, and
wall plugs.
OWS Field Installation
OWS Field Installation
Installing Antennas
This section provides instructions for installing and connecting antennas. The antennas shown in this section
are a representative sample only and are provided as a guideline for installation—your specific antenna(s)
may be different, in which case refer to the instructions provided with the antenna(s).
Antenna Warning
Antennas must be installed by a trained professional installer only.
Do not locate any antenna near overhead power lines or other electric light or power
circuits, or where the antenna can come into contact with such circuits. When
installing antennas, take extreme care not to come into contact with such electrical
circuits, as they can cause serious injury or death.
For the correct installation and grounding of antennas, please refer to national and local
codes (for example, US:NFPA 70, National Electrical Code, Article 810; in Canada:
Canadian Electrical Code, Section 54).
Applying Power Before an Antenna is Connected
Do not apply power to the transmitter until the antenna is connected, otherwise
permanent damage may result.
Strong RF Fields are Present
When the unit is operation, avoid standing directly in front of the antenna. Strong RF
fields are present when the transmitter is ON.
Notes About Antenna Installations
Read the following notes before installing any antenna.
◗ The system installer should always ensure that antenna radiation patterns do not overlap.
◗ A sector antenna should point towards the center of the sector covered by the antenna.
◗ Fixed point-to-point backhaul antennas should point towards the desired Strix Systems Access/One®
Network device intended for the backhaul connection.
◗ Unused antenna ports must be terminated with a 50 ohm terminator.
◗ Only antennas approved by Strix Systems (or equivalent) may be used with the Access/One® Network
Outdoor Wireless System (OWS).
◗ Only one antenna may be used on each antenna port.
◗ When installing antennas that require mounting brackets and U-bolts, it is easier to loosely attach the
U-bolts to the brackets, then slide the completed antenna assembly over the pole (instead of holding
the assembly against the pole and attaching each U-bolt separately—mounting brackets are shipped
with the U-bolts pre-assembled. For this reason, do not install an omni antenna at the top of the pole
before installing any directional/sectored antennas that will reside below it.
OWS Field Installation
OWS Field Installation
◗ Depending on the selected antenna(s) for your application, it may be necessary to configure the output
power of your OWS 2400 or OWS 3600 product. It is the installer’s responsibility to ensure the output
power is set correctly for the chosen antenna(s). To set the output power, go to Appendix I: Setting the
Output Power on page 32. Operation of the OWS 2400 or OWS 3600 in a manner other than as
represented here is a violation of FCC rules.
Maximum Power Settings for Antennas
The following are the maximum power settings for each antenna1 type, based on wireless technology,
antenna type and channels:
Channels for IEEE 802.11b/g
12 dBi Omni Antenna (2.4 GHz)
Power Level (dBm) *
Channel
Identifier
Frequency
(MHz)
Filter
2412
CCK
ODFM
Yes
Half (+24dBm)
Half (+23dBm)
2417
Yes
Half (+24dBm)
Half (+23dBm)
2422
Yes
Half (+24dBm)
Half (+23dBm)
2427
Yes
Half (+24dBm)
Half (+23dBm)
2432
Yes
Half (+24dBm)
Half (+23dBm)
2437
Yes
Half (+24dBm)
Half (+23dBm)
2442
Yes
Half (+24dBm)
Half (+23dBm)
2447
Yes
Half (+24dBm)
Half (+23dBm)
2452
Yes
Half (+24dBm)
Half (+23dBm)
10
2457
Yes
Half (+24dBm)
Half (+23dBm)
11
2462
Yes
Half (+24dBm)
Half (+23dBm)
* Listed power level settings are average power.
1. To comply with FCC standards for broadband emissions, a band pass filter is required
for 802.11g transmissions on channels 1 and 11 in the United States (RF Linx
Corporation part number 2400BPF-8-FB or equivalent), and for 802.11a transmissions
in the 5.725 - 5.850 GHz band when using the 23 dBi Patch Panel antenna in the United
States (K&L Microwave part number 6C50-5787.5/U120-n/n or equivalent). For
additional information, go to Appendix II: Installing the Band Pass Filter on page 33.
OWS Field Installation
OWS Field Installation
16.4 dBi Sector Antenna (2.4 GHz)
Power Level (dBm) *
Channel
Identifier
Frequency
(MHz)
Filter
2412
CCK
ODFM
Yes
Quarter (+21dBm)
Quarter (+20dBm)
2417
Yes
Quarter (+21dBm)
Quarter (+20dBm)
2422
Yes
Quarter (+21dBm)
Quarter (+20dBm)
2427
Yes
Quarter (+21dBm)
Quarter (+20dBm)
2432
Yes
Quarter (+21dBm)
Quarter (+20dBm)
2437
Yes
Quarter (+21dBm)
Quarter (+20dBm)
2442
Yes
Quarter (+21dBm)
Quarter (+20dBm)
2447
Yes
Quarter (+21dBm)
Quarter (+20dBm)
2452
Yes
Quarter (+21dBm)
Quarter (+20dBm)
10
2457
Yes
Quarter (+21dBm)
Quarter (+20dBm)
11
2462
Yes
Quarter (+21dBm)
Quarter (+20dBm)
* Listed power level settings are average power.
Channels for IEEE 802.11a
12 dBi Omni Antenna (5.25 – 5.35 GHz)
Power Level (dBm) *
Channel
Identifier
Frequency
(MHz)
Filter
52
5260
No
Quarter (+17dBm)
56
5280
No
Quarter (+17dBm)
60
5300
No
Quarter (+17dBm)
64
5320
No
Quarter (+17dBm)
ODFM
* Listed power level settings are average power.
10
OWS Field Installation
OWS Field Installation
12 dBi Omni Antenna (5.725 – 5.85 GHz)
Power Level (dBm) *
Channel
Identifier
Frequency
(MHz)
Filter
149
5745
No
Half (+23dBm)
153
5765
No
Full (+26dBm)
157
5765
No
Full (+26dBm)
161
5805
No
Full (+26dBm)
165
5825
No
Half (+23dBm)
ODFM
* Listed power level settings are average power.
23 dBi Patch Panel Antenna (5.25 – 5.35 GHz)
Power Level (dBm) *
Channel
Identifier
Frequency
(MHz)
Filter
52
5260
No
Minimum (+5dBm)
56
5280
No
Minimum (+5dBm)
60
5300
No
Minimum (+5dBm)
64
5320
No
Minimum (+5dBm)
ODFM
* Listed power level settings are average power.
23 dBi Patch Panel Antenna (5.725 – 5.85 GHz)
Power Level (dBm) *
Channel
Identifier
Frequency
(MHz)
Filter
149
5745
Yes
Half (+23dBm)
153
5765
Yes
Full (+26dBm)
157
5765
Yes
Full (+26dBm)
161
5805
Yes
Full (+26dBm)
165
5825
Yes
Half (+23dBm)
ODFM
* Listed power level settings are average power.
OWS Field Installation
11
OWS Field Installation
Attaching an Omni Antenna Directly to the OWS Enclosure
Parts Required
◗ Omni Antenna, with optional adapter (no special tools required).
1. If necessary, connect the optional
antenna adapter to the desired
antenna port at the bottom of the
OWS enclosure.
Hand tighten, making sure the
adapter is firmly in place—you
can use an adjustable wrench,
but do not overtighten or damage
the adapter.
Adapter
12
OWS Field Installation
OWS Field Installation
2. Thread the omni antenna onto
the antenna adapter—the
electrical connection between
the antenna and the enclosure is
established via the adapter.
There are no external cables
required when attaching an omni
antenna directly to the OWS
enclosure.
See also, Antenna Connector
Wiring Configurations on
page 22.
Adapter
Omni Antenna
OWS Field Installation
13
OWS Field Installation
Mounting a Directional Antenna on a Pole
Parts Required
◗ Pole.
◗ Directional antenna (includes adjustable mounting bracket).
◗ 2 straps, for mounting the antenna to a standard 1 7/8 inch diameter steel pole.
◗ Antenna cable.
Tools Required
◗ Flat blade screwdriver
1. Attach the 2 straps (hose clamps)
to the mounting bracket.
Antenna
Straps (x2)
2. Mount the antenna to the pole
with the 2 straps.
Adjust the antenna to the desired
position, then use a flat blade
screwdriver or 5/16 inch nut
driver to tighten both straps to
10–12 lbf.ft (1.38–1.66 kgf.m).
14
OWS Field Installation
OWS Field Installation
Vertical Adjustment
3. Using a flat blade screwdriver,
fine tune the position of the
antenna by adjusting the
mounting bracket along the
vertical axis and the horizontal
axis.
Tighten the mounting bracket
adjustment screws to 10–12 lbf.ft
(1.38–1.66 kgf.m).
Horizontal Adjustment
4. Connect one end of the antenna
cable to the directional antenna,
then connect the other end of the
cable to an available antenna
port on the OWS enclosure.
See also, Antenna Connector
Wiring Configurations on
page 22 and Antenna Connector
Wiring Configurations on
page 22.
Antenna Cable
Connect between the directional
antenna and a free antenna port on
the OWS enclosure
OWS Field Installation
15
OWS Field Installation
Mounting a Sectored Antenna on a Pole
Parts Required
◗ Pole.
◗ Sectored antenna.
◗ 2 U-bolt assemblies, for mounting the antenna to a standard 1 7/8 inch diameter steel pole.
◗ Adjustable mounting bracket (including antenna mounting plate and U-bolt assemblies).
◗ Antenna cable.
Tools Required
◗ 7/16 inch nut wrench
1. If not already assembled,
assemble the adjustable
mounting bracket.
Secure the antenna mounting
plate to the antenna body with 4
x 7/16 inch screws and spring
washers. Use a 7/16 inch nut
wrench to tighten the screws to
10–12 lbf.ft (1.38–1.66 kgf.m).
Attach the mounting bracket to
the antenna mounting plate with
6 x 7/16 inch screws and spring
washes—finger tighten only.
The U-bolts are pre-assembled
with the mounting bracket.
Antenna Mounting Plate
Secure to antenna body
with 4 x 7/16 inch screws
and spring washers
16
Mounting Bracket
Attach to mounting plate
with 6 x 7/16 inch screws
and spring washers—finger
tighten only
OWS Field Installation
OWS Field Installation
2. Attach the sectored antenna to
the pole—finger tighten only.
3. Adjust the antenna to the desired
position on the pole (up and
down or rotational).
4. Use a 7/16 inch nut wrench to
tighten the U-bolts (4 nuts) and
secure the sectored antenna in
place.
Tighten all four nuts to 10–12
lbf.ft (1.38–1.66 kgf.m).
When tightening the U-bolts,
ensure that the bolts are not
twisted—the ends of each U-bolt
should be protruding through the
mounting bracket evenly (the
same distance).
OWS Field Installation
17
OWS Field Installation
Vertical Adjustment (up to 30 degrees)
5. If necessary, use a 7/16 inch nut
wrench to loosen the 6 bolts on
the adjustable mounting bracket.
Make your vertical adjustment to
the sectored antenna (up to 30
degrees), then tighten all 6 bolts
to 10–12 lbf.ft (1.38–1.66 kgf.m).
6. Connect one end of the antenna
cable to the sectored antenna,
then connect the other end of the
cable to an available antenna
port on the OWS enclosure.
See also, Antenna Connector
Wiring Configurations on
page 22 and Antenna Connector
Wiring Configurations on
page 22.
Antenna Cable
Connect between the
sectored antenna and a
free antenna port on the
OWS enclosure
18
OWS Field Installation
OWS Field Installation
Mounting an Omni Antenna on a Pole
Parts Required
◗ Pole.
◗ Omni antenna.
◗ 2 U-bolt assemblies, for mounting the antenna to a standard 1 7/8 inch diameter steel pole.
◗ Mounting bracket.
◗ Antenna cable.
Tools Required
◗ 1/2 inch nut wrench
◗ 7/8 inch nut wrench
Omni Antenna
1. Attach the omni antenna to the
mounting bracket, using the
washer and locknut provided.
Mounting Bracket
The U-bolts are pre-assembled
with the mounting bracket.
Washer
2. Use a 7/8 inch nut wrench to
tighten the locknut to 10–12 lbf.ft
(1.38–1.66 kgf.m).
U-Bolt Assembly (x2)
Includes:
◗
◗
◗
◗
U-bolt
Plain washers (2)
Spring washers (2)
Nuts (2)
Locknut
OWS Field Installation
19
OWS Field Installation
3. Attach the omni antenna to the
pole—finger tighten only.
4. Adjust the omni antenna to the
desired position on the pole (up
and down or rotational).
5. Use a 1/2 inch nut wrench to
tighten the U-bolts (4 nuts) and
secure the omni antenna in
place.
Tighten all four nuts to 10–12
lbf.ft (1.38–1.66 kgf.m).
When tightening the U-bolts,
ensure that the bolts are not
twisted—the ends of each U-bolt
should be protruding through the
mounting bracket evenly (the
same distance).
Tighten (4 places)
20
OWS Field Installation
OWS Field Installation
6. Check that the U-bolts are tight
and that the omni antenna is
securely anchored to the pole.
7. Connect one end of the antenna
cable to the omni antenna, then
connect the other end of the
cable to an available antenna
port on the OWS enclosure.
See also, Antenna Connector
Wiring Configurations on
page 22 and Antenna Connector
Wiring Configurations on
page 22.
Antenna Cable
Connect between the omni
antenna and a free antenna port on
the OWS enclosure
OWS Field Installation
21
OWS Field Installation
Antenna Connector Wiring Configurations
The following table shows the antenna connector wiring configurations for the OWS family of products:
Antenna Connector Wiring
Product
Enclosure Connector
Module Connector
2400 series and 3600 series
ant. 1
G ANT1 – J24
2400 series and 3600 series
ant. 2
A ANT1 – J21
2400 series and 3600 series
ant. 3
G ANT1 – J24
2400 series and 3600 series
ant. 4
A ANT1 – J21
2400 series and 3600 series
ant. 5
G ANT1 – J24
2400 series and 3600 series
ant. 6
A ANT1 – J21
3600 series only
ant. 7
A ANT1 – J21
3600 series only
ant. 8
G ANT1 – J24
Physical Layout (Enclosure)
The following diagram shows the physical layout of antenna connectors on the OWS 3600 enclosure (the
OWS 2400 does not have the ant. 7 or ant. 8 antenna options).
ant. 1
ant. 2
ant. 3
ant. 4
ant. 5
ant. 6
ant. 7
ant. 8
22
OWS Field Installation
OWS Field Installation
Physical Layout (Wireless Modules)
The following diagram shows the physical layout of antenna connectors on the OWS wireless modules (top
view, looking down on module when the enclosure door is open).
G ANT1
G ANT2
A ANT2
A ANT1
Routing the Antenna Cables
It is important that when you install the antenna cables they are not hanging randomly and that the cables are
secured. This section provides a sample routing scenario.
1. If mounting the OWS on a pole,
route the antenna cables through
the OWS enclosure mounting
bracket and secure with cable
ties.
Ensure that the cables are not
twisted.
2. If mounting the OWS on a wall,
the cables should be fixed to the
wall with a suitable cable clamp.
OWS Field Installation
23
OWS Field Installation
Grounding the OWS Enclosure
This section provides instructions for grounding the OWS enclosure.
Grounding Caution
You must ALWAYS install an external grounding wire. The ground connection must be
complete before connecting power to the OWS enclosure—a simple continuity check
between the enclosure and the ground termination point can confirm this. Grounding of
the OWS must comply with National Electrical Code (NEC) requirements, unless local
codes in your area take precedence over the NEC code.
Parts Required
◗ Ground wire assembly (with ring terminator)—must be 18 gauge AWG wire, or greater.
Tools Required
◗ 3/16 inch nut wrench
◗ Wire stripper (if necessary)
1. Connect the ground wire to the
ground terminal on the bottom of
the OWS enclosure.
Make sure the lock washer is in
place and that the nut is securely
fastened.
2. Connect the other end of the
ground wire to a grounding strap
attached to a grounded surface,
such as a cold water pipe (or
other suitable ground termination
point, compliant with NEC and
local standards).
On pole-mounted OWS
enclosures, if the pole (or pole
stand) is already grounded, you
may use one of these items as the
ground termination point.
24
Ground Wire
Connect to a
suitable ground
termination
OWS Field Installation
OWS Field Installation
Configuring the Power Cord
This section provides instructions for configuring the power cord (not supplied) for either AC or DC operation,
and connecting the power cord to the OWS enclosure.
Electrical Power Warning
This unit must be installed by a trained professional installer only. Read the installation
instructions before you connect the wireless network device to its power source.
Power Cord Assembly Caution
The power cord must be assembled by a professional installer, and the final assembly
must comply with National Electrical Code (NEC) requirements, unless local codes in
your area take precedence over the NEC code.
Parts Required
◗ AC or DC power cord (not supplied), cut to the desired length.
◗ AC/DC plug assembly.
Tools Required
◗ Wire stripper
◗ Flat blade screwdriver
Pin 5
Pin 1
Pin 4
Pin 2
1. Review the pin connections.
◗
◗
◗
◗
◗
Pin 1 – AC Neutral
Pin 2 – DC Positive (+)
Pin 3 – Ground
Pin 4 – DC Negative (–)
Pin 5 – AC Line
The example opposite shows an
AC plug assembly.
Pin 3
2. Assemble the plug and connect
the plug to the power cord of
your choice for the electrical
configuration you need, either
AC or DC.
Plug Assembly
Power Cord
The power cord must be
assembled by a professional
installer.
Collar
Shield
Locking Ring
OWS Field Installation
25
OWS Field Installation
3. Attach the plug to the enclosure’s
power receptacle.
Power Receptacle
Plug
4. Turn the locking ring of the plug
and hand tighten to make the
connection.
5. Install an appropriate AC or DC
connector at the other end of the
power cord.
Locking Ring
The AC1 connector you use at the
other end of the power cord
depends on the AC power source
you are connecting to. Refer to
AC Wiring Configurations on
page 27.
1. If using an AC power source, to comply with FCC standards for
radiated spurious EMF emissions a 30 MHz to 1 GHz ferrite core must
be attached to the AC power cord in a double-turn configuration (as
close to the OWS enclosure as possible. A suitable ferrite core for this
purpose can be obtained from Fair-Rite Products Corporation, part
number 0444164181 (round cable snap-it model).
26
OWS Field Installation
OWS Field Installation
AC Wiring Configurations
The following diagrams show alternative wiring configurations for AC input power options.
120 VAC Single Phase (two wire service)
240 VAC Single Phase (two wire service)
208 VAC Three Phase (two wire service – grounded/Wye)
240 VAC Three Phase (two wire service – Delta)
OWS Field Installation
27
OWS Field Installation
Connecting the Ethernet Cable
This section provides instructions for configuring the CAT5 Ethernet cable.
Parts Required
◗ Plenum-rated CAT5 Ethernet cable, cut to the desired length (not supplied).
◗ RJ45 plug assembly.
Tools Required
◗ Wire stripper
1. Review the pin connections.
◗
◗
◗
◗
◗
◗
◗
◗
28
Pin 1 – TXD+ (TX Data)
Pin 2 – TXD- (TX Data)
Pin 3 – RXD+ (RX Data)
Pin 4 – Not used
Pin 5 – Not used
Pin 6 – RXD- (RX Data)
Pin 7 – Not used
Pin 8 – Not used
◗ Continuity checker
Pin 4
Pin 5
Pin 3
Pin 6
Pin 2
Pin 7
Pin 1
Pin 8
OWS Field Installation
OWS Field Installation
2. Assemble the RJ45 plug/cable.
◗
◗
◗
◗
◗
Item 1 – Shielded RJ45 plug
Item 2 – Gasket seal
Item 3 – Plug holder
Item 4 – Coupling ring
Item 5 – Seal assembly
When assembling the plug, take
care not to lose the gasket seal
(item 2)—it must be in place
when the assembly is complete.
3. Install an RJ45 plug at the other
end of the cable.
4. Perform a continuity check on
each pin to verify that the
Ethernet cable1 has been
assembled correctly.
5. Unscrew the protective cap, then
connect the Ethernet cable to the
OWS enclosure.
Turn the coupling ring clockwise
(1/4 turn) to make the
connection.
Cap
The connection is locked when
you feel and hear a click.
1. To comply with FCC standards for radiated spurious EMF emissions a
30 MHz to 1 GHz ferrite core must be attached to the Ethernet cable in
a double-turn configuration. A suitable ferrite core for this purpose can
be obtained from Fair-Rite Products Corporation, part number
0444167281 (round cable snap-it model).
OWS Field Installation
29
OWS Field Installation
Powering Up the OWS
This section provides instructions for powering up the OWS from both an AC and DC power source.
Powering Up from an AC Power Source
Important Note (AC Power)
AC input: 100 – 240 VAC (50/60 Hz) at 1.0 Amp maximum, supplied by a separate
branch circuit with 2 Amp over-current protection (2 Amp circuit breaker).
The OWS must always be grounded before applying power to the unit—see Grounding
the OWS Enclosure on page 24.
1. Verify that the AC service voltage is 120 VAC to 240 VAC.
2. Check that the power is turned OFF at the designated circuits.
3. If necessary, install 1/2 inch liquid-tight conduit from the power source to within 3 feet of the OWS,
then connect the conduit to a junction box. The conduit and junction box must be IEEE/ANSI
compliant and suitable for outdoor use.
4. Connect the OWS power cord to the AC supply.
5. Close the enclosure’s door (the OWS door interlock will actuate).
6. Turn ON the AC supply.
Powering Up from a DC Power Source
Important Note (DC Power)
DC input: 12 – 24 VDC at 9.0 Amp maximum, supplied by an external separate 250 VA
power-limited (or less) and isolated DC source with 15 Amp over-current protection (15
Amp circuit breaker).
The OWS must always be grounded before applying power to the unit—see Grounding
the OWS Enclosure on page 24.
1. Verify that the DC service voltage is 12 VDC to 24 VDC.
2. Check that the power is turned OFF at the designated circuits.
3. If necessary, install 1/2 inch liquid-tight conduit from the power source to within 3 feet of the OWS,
then connect the conduit to a junction box. The conduit and junction box must be IEEE/ANSI
compliant and suitable for outdoor use.
4. Connect the OWS power cord to the DC supply.
5. Close the enclosure’s door (the OWS door interlock will actuate).
6. Turn ON the DC supply.
30
OWS Field Installation
OWS Field Installation
OWS Product Specifications
WIRELESS
ENVIRONMENTAL
◗ Wireless Standards: IEEE 802.11a/g
◗ Frequency Bands:
802.11a
- 5.25 - 5.35 GHz
- 5.725 - 5.850 GHz
802.11g
- 2.4 - 2.4835 GHz (Americas, FCC)
◗ Data Rates (Mbps):
- 6, 9, 12, 18, 24, 36, 48, 54 (802.11a/g)
- 12, 18, 24, 36, 48, 72, 96, 108 (802.11a Turbo)
◗ Wireless Medium:
802.11a – OFDM, 802.11g – DSSS
◗ Modulation:
- 802.11a: BPSK, QPSK, 16 QAM, 64 QAM
- 802.11g: DBPSK, DQPSK, CCK
◗ Operating Channels:
802.11a
- 12 (Americas, FCC), includes 3 turbo channels
802.11g
- 11 (Americas, FCC)
◗ Transmit Power:
Configuration dependent—contact Strix
◗ Receiver Sensitivity:
Configuration dependent—contact Strix
◗ LO (crystal) Frequency Stability:
+/-10PPM within normal op. range of 0° to 55°C
◗
◗
◗
◗
◗
◗
◗
◗
ELECTRICAL
◗ Power Input:
Auto-sensing 120/240 VAC, 50/60 Hz, single
phase, with ANSI/IEEE C62.41 category C3
integrated branch circuit protection
◗ AC Power Consumption:
25W typical, 90W maximum
◗ DC Input:
12/24V, 9A maximum
PROTECTION CIRCUITS
◗ Antenna Lightning Protection (optional):
< 9µJ for 6kV/3kA @ 8/20µs waveform
◗ Electrical Protection:
ANSI/IEEE C62.41, UL 1449 2nd edition; 10kA @
8/20 µs waveform, 36kA per phase; L-L, L-N, L-PE
◗ Data Protection:
EN61000-4-2 Level 4 ESD Immunity
EN61000-4-5 Level 4 AC Surge Immunity
EN61000-4-4 Level 4 Elect. Fast Transient Burst
Immun.
EN61000-4-3 EMV Field Immunity
OWS Field Installation
Operating Temperature: -40°C to +55°C
Storage Temperature: -55°C to +85°C
Humidity: 10% to 90% non-condensing
Weather Rating: IP67 weather tight
Wind Survivability: <165 mph
Wind Loading (165 mph): <1024 newtons
Salt/Fog/Rust Resistance: Mil-STD-810F 509.4
Shock & Vibration:
ESTI 300-192-4 spec T41.E
Class 4M3 and Mil-STD-810
◗ Transportation: ISTA 2A and Mil-STD-810
PHYSICAL
◗ Dimensions:
3600 Series: 14” high x 12” wide x 8” deep (without
accessories)
2400 Series: 12” high x 10” wide x 6” deep (without
accessories)
◗ Weight:
3600 Series: 16.5lbs (7.48 Kg)
2400 Series: 14.5lbs (6.58 Kg)
◗ NEMA 4 rated for outdoor enclosures
SECURITY
◗ Authentication:
802.1x support, including RADIUS client, EAP-MD5,
EAP-TLS, and PEAP-TTLS, WPA
◗ Encryption:
IEEE 802.11i (WPA) with AES, and WEP
REMOTE MANAGEMENT
◗ Web, CLI and SNMP interfaces
◗ Supports BOOTP, DHCP, Telnet, SSH, HTTP, HTTPs, and
FTP
◗ SNMP: MIB II, 802.11 MIB, and Strix private MIBs
APPROVALS
◗
◗
◗
◗
◗
◗
◗
FCC CFR47 Part 15, Class B
Industry Canada RSS210
EN60950 cTUVus Listed I.T.E
UL 579/IEC 60529 IP67, rated for outdoor use
UL 1449 2nd edition / IEC 60664-1
CAN/CSA-C22.2 60950-00
VCCI Class B
WARRANTY
◗ One year parts and labor
31
OWS Field Installation
Appendix I: Setting the Output Power
Use the following procedure to set the output (transmit) power for the chosen antenna:
1. Establish a Telnet connection with the selected wireless module (radio).
2. Log in to the radio.
3. Type the command get power.
The system displays the current power settings for the selected radio.
If the radio is set to the desired power setting, no further action is required and you can log out,
otherwise go to Step 4. The following list shows the available power settings:
◗ Full – sets the maximum (normal) transmit power. This is the default setting.
◗ Half – sets the transmit power to a fractional half of the full power.
◗ Quarter – sets the transmit power to a fractional quarter of the full power.
◗ Eighth – sets the transmit power to a fractional eighth of the full power.
◗ Minimum – sets the transmit power to its minimum.
4. To set the power output for the selected radio, type the command set power and append the desired
setting to the command. For example, to set the output power to minimum, type set power min. Or,
to set the output power to one quarter, type set power quarter.
When the command is entered, the system displays the new power setting automatically. However, if
you need to verify the output power setting for any radio, use the command get power. The following
graphic shows the output power for a radio being changed from full to one quarter.
32
OWS Field Installation
OWS Field Installation
Appendix II: Installing the Band Pass Filter
The band pass filter must be installed as close to the OWS enclosure as possible. The following graphic shows
the filter installed on the OWS at its preferred location (connected directly to the antenna connector on the
enclosure).
Antenna
Pole
OWS Enclosure
Antenna Cable
Band Pass Filter
OWS Field Installation
33
OWS Field Installation
34
OWS Field Installation
OWS Field Installation
Index
FCC notice ii
Federal Aviation Administration 1
filter 33
AC power 30
adapter 12, 13
airplanes
use in 1
antenna
directional 14
antenna adapter 13
antennas
cable routing 23
directional 14
installing 8
omni 12, 19
placement 2
routing cables 23
sectored 16
type 2
gasket seal 29
ground termination 24
grounding 24
band pass filter
installing 33
building codes 2
building materials 2
CAT5 28
CAT5 cable 28
contact information i
continuity check 29
copyright notice i, ii
coupling 29
data rates 2
DC power 30
directional antenna 8, 14
adjusting 15
enclosure 3
enclsure
grounding 24
environmental limits 1
Ethernet cable 28
European Community (EC) conformity ii
explosive device proximity iii
FAA 1
OWS Field Installation
hazardous locations 1
hospitals
use in 1
Industry Canada notice ii
limited warranty v
local guidelines 2
maximum power settings 9
mounting 3
brackets 3
on a vertical pole 3
on a wall 7
NEC code 2, 24, 28
non-modification statement iii
notices ii
European Community (EC) ii
FCC ii
Industry Canada ii
VCCI ii
obstructions 2
omni antenna 8, 12, 19
output power
setting 32
over-current protection 30
OWS 2400 1
OWS 3600 1
OWS enclosure 3
grounding 24
physical environment 2
planning the installation 2
planning your installation 2
pole 3
35
OWS Field Installation
power settings 9
power source 2
powering up 30
product specifications 31
RF exposure iii
RJ45 plug assembly 29
safety information 1
safety warnings iii
sectored antenna 16
setting the transmit power 32
site survey 2
site surveys 2
solar shield iv
specifications 31
straps 3, 6
Strix contact information i
survey 2
table of contents vii
theory of operation 1
transmit power 32
u-bolts 3, 4
VCCI notice ii
vertical mounting brackets 3
vertical pole 3
warnings iii
antenna placement iv
electrical power iii
general safety iii
grounding the unit iv
lightning activity iii
warranty v
36
OWS Field Installation

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 44
Page Mode                       : UseOutlines
Page Layout                     : SinglePage
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:32698a85-577d-4f6b-9ef3-7f7c33421f74
Producer                        : Acrobat Distiller 6.0 (Windows)
Create Date                     : 2006:04:13 10:57:41Z
Creator Tool                    : FrameMaker 6.0
Modify Date                     : 2006:04:13 12:08:49-07:00
Metadata Date                   : 2006:04:13 12:08:49-07:00
Document ID                     : uuid:f30b85ab-cd27-467e-8203-a82bc82630ad
Format                          : application/pdf
Title                           : ows_hardware_installation_manual.book
Creator                         : Bill Wareing
Author                          : Bill Wareing
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RFM-ACCESS-ONE-21

Navigation menu