Strix Systems MWS100NA 802.11 a/g Wireless Networking Device User Manual MWS100 Config A3

Strix Systems, Inc. 802.11 a/g Wireless Networking Device MWS100 Config A3

User Guide

Download: Strix Systems MWS100NA 802.11 a/g Wireless Networking Device User Manual MWS100 Config A3
Mirror Download [FCC.gov]Strix Systems MWS100NA 802.11 a/g Wireless Networking Device User Manual MWS100 Config A3
Document ID930816
Application IDupjU0vlRzQemn6kBh3jK5w==
Document DescriptionUser Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize41.97kB (524564 bits)
Date Submitted2008-04-21 00:00:00
Date Available2008-04-21 00:00:00
Creation Date2008-04-14 22:36:47
Producing SoftwarePrimoPDF
Document Lastmod2008-04-14 22:36:47
Document TitleMicrosoft Word - MWS100_Config_A3.doc
Document CreatorPrimoPDF http://www.primopdf.com/
Document Author: Richard

Access/One ® Edge
MWS100 Configuration Guide
MWS100
Mobile Wireless System
Revision A3
April 14, 2008
Copyright © 2003 – 2008 Strix Systems, Inc.
26610 Agoura Road
Calabasas, CA 91302
USA
Networks Without Wires®
MWS100 Configuration Guide
FCC Notice
This wireless network device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: 1. This device may not cause harmful
interference. 2. This device must accept any interference received, including interference
that may cause undesired operation. This wireless network device has been tested and
found to comply with the limits for a Class B digital device pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This wireless network device generates, uses,
and radiates radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this wireless
network device does cause harmful interference to radio or television reception, which
can be determined by turning the wireless network device off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna; Increase the separation between the wireless
network device and the affected receive; Connect the wireless network device into an
outlet on a circuit different from that to which the receiver is connected; Consult the
dealer or an experienced radio/TV technician for help.
European Community (EC) Directives and Conformity
This wireless network device is in conformity with the Essential Requirements of R&TTE
Directive 1999/5/EC of the European Union.
Non-Modification Statement
Unauthorized changes or modifications to Strix devices are not permitted. Modifications
to Strix devices will void the warranty and may violate FCC or other regulations.
RF Exposure Requirements
To ensure compliance with FCC RF exposure requirements, the antenna used for this
wireless network device must be installed to provide a separation distance of a minimum
of 40cm or more from all persons, and must not be co-located or operated in conjunction
with any other antenna or radio transmitter. Installers and end-users must follow these
installation instructions.
Professional Installation Only
This unit must be installed by a trained professional installer only.
MWS100 Configuration Guide
Table of Contents
1.
Introduction.............................................................................................................. 1
2.
Front Panel Indicators ............................................................................................. 2
3.
Rear Panel Connectors ........................................................................................... 3
4.
Installation ............................................................................................................... 4
5.
Wireless Station Configuration................................................................................. 6
6.
Wireless Access Point Configuration ....................................................................... 8
7.
Configuration and Status Monitoring ........................................................................ 9
MWS100 Configuration Guide
1.
Introduction
1 Introduction
The MWS100 is intended for mobile wireless broadband applications and is
designed for vehicular deployment. The MWS100 is a member of the Strix
Access/One® Edge product family, and interoperates with Strix Access/One®
Mesh Nodes. Within a region where Strix Access/One® Mesh Nodes are
deployed, the MWS100 provides broadband data access and seamless roaming
between nodes, even at high vehicle speeds.
The MWS100 contains two 802.11-type radios. One is an 802.11g radio that
operates in the 2.4 GHz band. The other is an 802.11a radio that operates in
either the 5 GHz band or the 4.9 GHz U.S. Public Safety band. One of these
radios will operate as a Wireless Station (STA) and be used to connect wirelessly
to s Strix Access/One® Mesh Network. The other radio may optionally be used as
a Wireless Access Point (AP). An Ethernet connector is also provided for
connection to devices within the vehicle.
The MWS100 operates as a bridge between its Station Radio, Access Point
Radio, and Ethernet Port. This bridging function is accomplished using Layer 2
Network Address Translation (L2NAT). The purpose for this is to allow multiple
client devices, each with a unique IP address, to be supported by a single
wireless association with the Access/One® Mesh Network.
Note: Different MWS100 models exist for different regions
and regulatory domains. Availability of specific bands,
channels within those bands, and operating modes varies
depending upon the specific MWS100 model.
Strix Systems Access/One Edge
MWS100 Mobile Wireless System
MWS100 Configuration Guide
2.
Front Panel Indicators
2 Front Panel Indicators
PWR LED – This indicator displays the
status of the MWS100 power source. It
will illuminate when power is applied top
the unit.
SIG LED – This indicator displays the
operational status of the MWS100 radios.
Rapid blinking (4 blinks per second) indicates
that the radios are beginning operation
(rebooting). Slow blinking (once per second)
indicates that the OWS100 Station radio is
seeking a signal from a Strix OWS Access
Point. A sequence of two or more slow blinks
indicates that a connection with a Strix OWS
access point has been achieved, then the
relative signal strength (2 blinks indicates low
signal strength, 5 blinks indicates high signal
strength).
Strix Systems Access/One Edge
MWS100 Mobile Wireless System
MWS100 Configuration Guide
3.
Rear Panel Connectors
3 Rear Panel Connectors
PWR – Attach the
supplied fused
power cable.
RST – Performs a
restart.
LAN – 10/100
BASE-T Ethernet
with 802.3af PoE
input.
AUX – R-SMA
secondary antenna
connector.
MAIN – R-SMA primary
antenna connector.
Strix Systems Access/One Edge
MWS100 Mobile Wireless System
MWS100 Configuration Guide
4.
Installation
4 Installation
Note: The MWS100 is designed for professional installation. Failure to comply
fully with these instructions may void the MWS100 warranty and/or violate local
safety or radio regulations.
1. Select a mounting location for the MWS100. The MWS100 is designed for
mounting in an interior compartment or trunk of an automobile. It is not
intended for outdoor deployment. The MWS100 must not be exposed to
liquids. Mount the MWS100 using the chassis mounting holes and hardware
suitable for the particular installation.
2. Select antennas with gain specifications according to the table below.
Note: The maximum allowable power for each antenna type is noted in the last column. The
installer must set the power correctly for the chosen antennas.
Frequency
Antenna Type
Connection Method
Maximum
Gain
Maximum
Power Setting
2412-2462MHz
5150-5250MHz
5745-5850MHz
Linear Polarized
Dome
LMR200 Cable (> 3 ft.
length)
4 dBi
Full
2412-2462MHz
5150-5250MHz
5745-5850MHz
Omni-directional
Direct connection to
MWS100
3 dBi
5 dBi
5 dBi
Full
2412-2462MHz
Omni-directional
LMR200 Cable (> 3 ft.
length)
8 dBi
Full
5745-5850MHz
Omni-directional
LMR200 Cable (> 3 ft.
length)
12 dBi
-3dB (23dBm)
4940-4990MHz
Omni-directional
LMR200 Cable (> 3 ft.
length)
11 dBi
Full
3. Mount the selected antennas securely onto the vehicle following all antenna
manufacturer instructions and recommendations. Provide a suitable length of
LMR-200 type antenna cable between each antenna and the MWS100. If
using only one antenna, connect it to the port labeled “MAIN”. Connect a
second antenna to the port labeled “AUX”.
Strix Systems Access/One Edge
MWS100 Mobile Wireless System
MWS100 Configuration Guide
4. Using the supplied fused power cable, connect the BLACK wire to the vehicle
ground and then attach the RED wire to the vehicle positive DC supply. The
MWS100 is designed to operate from a minimum of 11 VDC* to a maximum
of 52 VDC and a maximum current draw of 2 A.
* A low-voltage cut-off circuit prevents the MWS100
from draining the vehicle battery. The unit will
automatically power down when the DC voltage falls
below 10.5 VDC. Operation will be restored once the
DC voltage rises above 11.5 VDC.
The MWS100 may also be powered over its Ethernet
port (LAN) by a PoE power injector capable of
sourcing 20 W.
5. Provide an Ethernet cable for connecting the MWS100 to a computer or
router.
6. Attach the supplied fused power cable to the PWR connector on the
EWS100 rear panel. Observe the LED indicator activity as described on page
2.
Strix Systems Access/One Edge
MWS100 Mobile Wireless System
MWS100 Configuration Guide
5.
Wireless Station Configuration
5 Wireless Station Configuration
MWS100 configuration screens may be accessed by connecting its LAN port to a
computer running Microsoft Internet Explorer Version 7. The default address of
http://169.254.1.250 may be used. The username for configuration is “Admin” (without
the quotes). The default password is “Admin” (also without quotes).
Important: After changing any parameter on any
configuration screen, an “Update” button will appear near
the upper-right corner of the screen. This must be pressed
for any change to take effect. Some changes require that
the MWS100 be re-booted. This is indicated by the
appearance of a “Reboot” button, which must be pressed
for the change to take effect.
The first step to configure an MWS100 is to select which radio will be used as a Wireless
Station to connect to the Strix Access/One® mesh network. The 11a radio is the default
for this. This may be changed from the “Configure  WiFi  General” screen.
Press the “Update” button if Station Radio selection is changed, followed by the “Reboot”
button.
Strix Systems Access/One Edge
MWS100 Mobile Wireless System
MWS100 Configuration Guide
The next step is to configure the selected Station radio to connect to the network. This is
performed on the “Configure  Wi-Fi  Station Configuration” screen. The default AP
Selection Method is “SSID” and is correct for most applications. Enter the SSID used by
the network for MWS100 applications, and then select the Security Mode and Security
Keys associated with that SSID. This information should be available from the operator
of the Strix Access/One® Mesh network.
After setting the Station radio parameters, press the “Update” button.
Strix Systems Access/One Edge
MWS100 Mobile Wireless System
MWS100 Configuration Guide
6.
Wireless Access Point Configuration
Wireless Access Point
Configuration
The Access Point radio may now be configured on the “Configure  Wi-Fi  AP
Configuration” screen. Set the SSID which client radios will use to connect to the
MWS100. The default behavior is for this SSID to be broadcast. This may be overridden
with the “Suppress SSID” checkbox. Enter Security Mode and Keys. Access may be
further restricted to specific client MAC addresses by pressing the “Manage ACL” button
to define an Access Control List.
After setting the AP radio parameters, press the “Update” button, then press the
“Reboot” button.
Strix Systems Access/One Edge
MWS100 Mobile Wireless System
MWS100 Configuration Guide
7.
Configuration and Status Monitoring
Configuration and Status
Monitoring
Configuration settings may now be verified on the “Home” screen. This screen shows
the connection status of the MWS100 Station radio as well as that of the MWS100
Access Point. Check to ensure that the MWS100 Station radio has associated to a Strix
Access/One® Mesh node with the correct SSID. Then, using a standard Wi-Fi client
device (such as a laptop computer), ensure that it can associate with the MWS100
Access Point radio.
Nearby Wireless Access Points may be viewed on the “Top Neighbors” window of the
“Home” screen. This is useful for identifying Strix Access/One® Mesh Nodes that the
MWS100 Wireless Station radio may connect to, or for identifying potential sources of
interference.
A more complete list of nearby radios may be seen using the “Wireless Neighbors”
selection in the “Quick Links” window under either the 802.11a or 802.11g headings.
Strix Systems Access/One Edge
MWS100 Mobile Wireless System
MWS100 Configuration Guide
A wide range of verification, status monitoring, and trouble-shooting tools are available
on the “Monitors” screen. The “Troubleshooting” window provides end-to-end network
diagnostics, verifying the Wireless Station link and connectivity back to the Default
Gateway, DHCP Server, and DNS server.
Other useful monitors are:
Client Monitor – Displays information about the clients currently connected to the
MWS100 Wireless Access Point.
Event Log – Displays a history of Station and Access Point connections and system
events.
L2NAT – Shows the associations between MAC addresses and IP addresses stored in
the Layer 2 Network Address Translation table.
Statistics – Various statistics useful for troubleshooting MWS100 operation.
Wireless History – Contains a chart showing a 24 hour history of the signal strength of
the Access/One® Mesh Network Access Point(s) as seen by the MWS100 Station radio.
Strix Systems Access/One Edge
MWS100 Mobile Wireless System
10

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Print high-res
Page Count                      : 14
Warning                         : XMP format error (no closing tag for ����ӆE���)
Producer                        : PrimoPDF
Create Date                     : 2008:04:14 22:36:47
Modify Date                     : 2008:04:14 22:36:47
Title                           : Microsoft Word - MWS100_Config_A3.doc
Creator                         : PrimoPDF http://www.primopdf.com/
Author                          : Richard
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RFM-MWS100NA

Navigation menu