2011/10  B.4 6390-009-001 REV B www.stryker.comPower-LOAD™ Cot Fastener System Model 6390Operations/Maintenance ManualFor parts or technical assistance:USA: 1-800-327-0770
www.stryker.com 6390-009-001 REV B 3Table of ContentsSymbols and Definitions ....................................................................5Symbols ............................................................................5Warning/Caution/Note Definition ...........................................................6Introduction .............................................................................7Product Description ....................................................................7Intended Use of Product.................................................................7Product Illustration.....................................................................7Important Contact Information ............................................................8Stryker Contact Information ..............................................................8Serial Number Location .................................................................8Specifications ........................................................................9Summary of Safety Precautions .............................................................11Pinch Points ........................................................................13Vehicle Cot Compatibility Information .........................................................14Installation Setup Procedures ...............................................................15Floor Plate Assembly Installation Component Checklist .........................................15Power-LOAD Assembly Installation Component Checklist .......................................16Optional Wheel Guide Assembly Installation Component Checklist ................................17Quality System Regulation for Installation ......................................................18Quality System Regulation ..............................................................18Floor Plate Installation Guidelines ............................................................19Installation Guide ........................................................................21Installing the Floor Plate (with a Wood Floor) ................................................21Installing the Power-LOAD System ........................................................27Installing The Optional Wheel Guide.......................................................34Installing Cot Wheel Covers .............................................................37Power-LOAD Installation Checklist ........................................................38User Setup Procedures....................................................................40User Controls and LED Indicators ............................................................41Manual User Controls.....................................................................43Power-PRO Cot User Controls...............................................................44Using the Cot Control Switches ..........................................................44Checking the Cot Battery Power Level .....................................................45Powered Operations Instructions.............................................................46Manual Operations Instructions..............................................................47Operation Guide.........................................................................48Operating Guidelines ..................................................................48Checking the Battery Power Level ........................................................49Charging the Battery ..................................................................49Storing Power-LOAD ..................................................................49Setting the Cot Load Height .............................................................49Using a Non-Upgraded X-Frame Cot for a Mass Casualty Incident ................................50Extending Power-LOAD from the Vehicle without a Cot .........................................50Loading a Performance-PRO Cot into a Vehicle (Model 6085/6086 with the Power-LOAD Option) .........51Unloading a Performance-PRO Cot from a Vehicle (Model 6085/6086 with the Power-LOAD Option) .......53
4 6390-009-001 REV B www.stryker.comLoading a Power-PRO Cot into a Vehicle (Model 6500/6506 & 6510/6516 with the Power-LOAD Option).....55Unloading a Power-PRO Cot from a Vehicle (Model 6500/6506 & 6510/6516 with the Power-LOAD Option) ..57Unloading a Cot From a Vehicle Manually (Power-LOAD Power Loss or System Error) ..................59Loading a Cot into a Vehicle Manually (Power-LOAD Power Loss or System Error) ....................61Unloading a Cot from a Vehicle Manually ...................................................62Removing a Cot from a Vehicle for Repair ..................................................63Loading a Cot into a Vehicle Manually (Power-PRO Power Loss) ..................................64Cleaning...............................................................................66Cleaning Procedure ...................................................................66Cleaning Limitations...................................................................66Removal of Iodine Compounds ...........................................................67Preventative Maintenance..................................................................68Warranty ..............................................................................69Stryker EMS Return Policy ..............................................................70Return Authorization...................................................................70Damaged Merchandise ................................................................70International Warranty Clause............................................................70Patent Information ....................................................................70EMC Information.........................................................................71Table of Contents
www.stryker.com 6390-009-001 REV B 5Return To Table of ContentsSymbols and DefinitionsWarning, consult accompanying documentationSafe Working LoadMaximum WeightDangerous VoltagePinch PointClass II Equipment: equipment in which protection against electric shock does not rely on basic insulation only, but in which additional safety precautions such as double insulation or reinforced insulation are provided, there being no provision for protective earthing or reliance upon installation conditions.Direct CurrentType B Equipment: equipment providing a particular degree of protection against electric shock, particularly regarding allowable leakage current and reliability of the protective earth connection.Internally Powered.ME EQUIPMENT or ME EQUIPMENT parts that include RF transmitters or that apply RF electromagnetic energy for diagnosis or treatmentUL60601-1 CAN/CSA C22.2 NO. 601.1Medical Equipment Recognized by Underwriters Laboratories Inc. With Respect to Electric Shock, Fire, and Mechanical Hazards Only in Accordance with UL 60601−1, and CAN/CSA C22.2 No. 601.1.The Rechargeable Battery Recycling Corporation (RBRC) is a non-profit, public service organization that promotes the recycling of portable rechargeable batteries. Batteries must be delivered to a battery collection site. Visit the RBRC website (www.rbrc.org) to find a nearby collection site or call the phone number shown on the recycling symbol. In accordance with European Directive 2002/96/EC on Waste Electrical and Electronic Equipment, this symbol indicates that the product must not be disposed of as unsorted municipal waste, but should be collected separately.  Refer to your local distributor for return and/or collection systems available in your country. ManufacturerSYMBOLS
6 6390-009-001 REV B www.stryker.comReturn To Table of ContentsSymbols and DefinitionsWARNING/CAUTION/NOTE DEFINITIONThe words WARNING, CAUTION and Note carry special meanings and should be carefully reviewed. WARNINGAlerts the reader about a situation which, if not avoided, could result in death or serious injury. It may also describe potential serious adverse reactions and safety hazards. CAUTIONAlerts the reader of a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property. This includes special care necessary for the safe and effective use of the device and the care necessary to avoid damage to a device that may occur as a result of use or misuse.NoteProvides special information to make maintenance easier or important instructions clearer.
www.stryker.com 6390-009-001 REV B 7Return To Table of ContentsIntroductionThis manual is designed to provide instructions for the operation and maintenance of the Stryker 6390 Power-LOAD™. Read it thoroughly before installing or using the equipment or beginning any maintenance on it. PRODUCT DESCRIPTIONThe Stryker 6390 Power-LOAD is designed to assist the user in loading the cot into a vehicle, unloading the cot from the vehicle, and to restrict the movement of the cot as it is being transported in the vehicle patient compartment under normal conditions. Usage of this product in any other way becomes the complete responsibility of the owner/user.  Caution must be used at all times during placement of the cot into the vehicle patient compartment.INTENDED USE OF PRODUCTThe Stryker 6390 Power-LOAD is intended to aid in the loading and unloading of a cot, patient and corresponding equipment to and from an ambulance/transport vehicle and holding of the cot during the transport (transports include from an emergency scene or patient location to a medical care center, from a medical care center to a medical care center, from a nursing home to another facility, etc). The safe working load of the system is 870 lb (395 kg), with a maximum patient weight of 700 lb (318 kg). Users of the device will be emergency medical service and medical care center personnel, as well as medical first responders, service technicians and installers. The device has an expected life of 7 years.PRODUCT ILLUSTRATIONTrolley AssemblyTransfer AssemblyAnchor AssemblyFloor PlateHead End Lock LEDError LEDBattery LEDFOOT ENDHEAD ENDFigure 1:  Product IllustrationSafety Hook
8 6390-009-001 REV B www.stryker.comReturn To Table of ContentsIntroductionIMPORTANT CONTACT INFORMATIONFor information about Federal Ambulance Specification KKK−A−1822, contact:Chief, Automotive & Commodity Management Branch (QMDAA)Office of Motor Vehicle ManagementGeneral Services Administration2200 Crystal Drive, Suite 1006Arlington, VA  22202Telephone:  703-605-2277For more information about AMD standards, contact:Ambulance Manufacturers Division(National Truck Equipment Association)37400 Hills Tech DriveFarmington Hills, MI  48331−3414STRYKER CONTACT INFORMATIONContact Stryker Customer Service or Technical Support at (800) 327-0770.Stryker Medical3800 E. Centre AvenuePortage, MI 49002USAPlease have the serial number (A) of your Stryker product available when calling Stryker Customer Service or Technical Support. Include the serial number in all written communication.SERIAL NUMBER LOCATIONAFigure 2:  Serial Number Location
www.stryker.com 6390-009-001 REV B 9Return To Table of ContentsIntroductionSPECIFICATIONSSafe Working LoadNote:  Safe Working Load represents the sum of the cot total weight and patient870 lb 395 kgMaximum Lift Capacity (patient and accessories) 700 lb 318 kgOverall Length/Minimum Length/Width 95 in / 85 in / 24.5 in 241 cm / 216 cm / 62 cmWeightFloor Plate Assembly 16.5 lb 7.5 kgAnchor Assembly 23 lb 10.5 kgTransfer Assembly 67 lb 30.5 kgTrolley Assembly 105 lb 48 kgMinimum Operators Required for Loading/Unloading an Occupied Cot2Minimum Operators Required for Loading/Unloading an Unoccupied Cot1Recommended Loading Height 22 in to 36 in 56 cm to 91 cmHydraulic Oil Mobil Mercon® V Synthetic Blend Oil (6500-001-293)Electrical Requirements 12.8V-15.6V , 15A breaker, 2 conductor 10 AWG cableBattery Duty Cycle, Charging 100%Battery Duty Cycle, Loading  10% (33 sec On / 5 min Off)Battery  12V , 5 Ah Lead Acid Battery (6390-001-468)Standards IEC 60601-1  CAN/CSA-C22.2 No. 601.1-M90UL 60601-1  IEC 60601-1-2:2007Stryker reserves the right to change specifications without notice.Patents pending.The yellow and black color scheme is a proprietary trademark of Stryker Corporation. WARNING• Do not operate Power-LOAD using a voltage inconsistent with the rating on the unit.• To avoid the risk of equipment damage or smoke hazard, do not use Power-LOAD above its duty cycle.• To ensure performance and prevent power hazards, connect Power-LOAD to a 12.8V-15.6V DC vehicle circuit that is on a 15A breaker.  Do not connect Power-LOAD to a 24V DC vehicle circuit. CAUTION• Changes or modifications to the Power-LOAD system not expressly approved by Stryker could void the user’s authority to operate the system.• This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their expense.
10 6390-009-001 REV B www.stryker.comReturn To Table of ContentsIntroductionSPECIFICATIONS (CONTINUED)Environmental Conditions Operation StorageTemperature -30  F(-34  C) 0 0130  F(54  C) 0  0158  F(70  C) 0 0-30  F(-34  C) 0 0Relative Humidity0%93%0%93%
www.stryker.com 6390-009-001 REV B 11Return To Table of ContentsSummary of Safety PrecautionsCarefully read and strictly follow the warnings and cautions listed on this page.  Service only by qualified personnel.  WARNING• Do not operate Power-LOAD using a voltage inconsistent with the rating on the unit.• To avoid the risk of equipment damage or smoke hazard, do not use Power-LOAD above its duty cycle.• To ensure performance and prevent power hazards, connect Power-LOAD to a 12.8V-15.6V DC vehicle circuit that is on a 15A breaker.  Do not connect Power-LOAD to a 24V DC vehicle circuit.• Power-LOAD is designed to be compatible with the Performance-PRO XT, Power-PRO XT, and Power-PRO IT cots with the Power-LOAD option only.  In certain situations, you can use Power-LOAD as a standard antler for most X-frame cots, but a rail clamp assembly is required for all cots without the Power-LOAD option. • It is the responsibility of the cot operator to ensure that the cot being used in the Stryker Model 6390 Power-LOAD system is a Power-LOAD compatible cot.  Injury may result if a non-compatible cot is used in the Stryker Model 6390 Power-LOAD system.• Improper installation can result in injury.  Install the Stryker Model 6390 Power-LOAD system as described in this manual.  Ensure that, at a minimum, your configuration with Power-LOAD is tested to meet AMD Standard 004.• Take special precautions regarding electromagnetic compatibility (EMC) when using medical electrical equipment like Power-LOAD.  Install and place Power-LOAD into service according to the EMC information in this manual. Portable and mobile RF communications equipment can affect the function of Power-LOAD.• To avoid the risk of personal injury or equipment damage, properly secure the item that you are cutting and be aware of the area around your cutting location.  Always wear appropriate eye protection while operating a saw.  • During installation, always wear safety glasses and a face mask while operating a router.• To avoid the risk of personal injury or vehicle damage, be aware of items around and below the electrical inlet during floor plate installation.• Ensure that all gaps to the exterior of the vehicle are sealed to prevent exhaust fumes from entering the vehicle patient compartment.• To prevent exhaust fumes from entering the vehicle patient compartment, route the drain tube under the vehicle away from the exhaust system.• To avoid the risk of personal injury or vehicle damage, be aware of items around and below the anchor to vehicle cable during floor plate installation.• Failure to install the safety hook can cause injury to the patient or operator.  Install and use the safety hook as described in this manual.• To avoid the risk of injury, two installers are required when lifting and positioning the transfer assembly.• To avoid the risk of injury, keep hands and fingers clear of all moving mechanisms.• To avoid the risk of injury, two installers are required when lifting and positioning the trolley assembly.• To avoid the risk of patient injury, adjust the cot height to match the vehicle deck height as described in the appropriate cot operations/maintenance manual for your cot model.• Improper usage of the Power-LOAD system or any accessory can cause injury to the patient or operator.  Operate the Power-LOAD system and accessories only as described in the manuals.• For manual operations, the operator must support the foot end of the cot.• Failure to ensure proper Power-LOAD functionality prior to use may result in patient and/or operator injury.• Use caution while moving around in the vehicle patient compartment to avoid tripping on Power-LOAD.• To avoid the risk of operator and/or patient injury, use caution when operating Power-LOAD in adverse weather conditions (for example, rain, ice, snow).• Entanglement in powered cot and/or Power-LOAD mechanisms can cause serious injury. Operate the cot and/or Power-LOAD only when all persons are clear of the mechanisms.• Practice loading and unloading the cot with Power-LOAD until operation of the product is fully understood. Improper use can cause injury.• Do not allow untrained personnel to assist in the operation of Power-LOAD. Untrained technicians/personnel can cause injury to the patient or themselves.• To reduce the risk of patient injury and/or equipment damage, do not drive the vehicle with the trolley in the mid position.  This position does not lock and is not intended for driving.• Power-LOAD is only an assisting device.  Operators are responsible for evaluating each situation to determine how to distribute and lift the weight being transported.  Always use both hands when handling the cot.• When handling weights over 400 lb (181 kg), ensure there are enough operators to handle the forces required for loading/unloading.  To increase safety, users should attempt to perform loading/unloading on flat surfaces.
12 6390-009-001 REV B www.stryker.comReturn To Table of ContentsSummary of Safety Precautions WARNING (CONTINUED)• Keep hands and extremities clear of the Power-LOAD trolley lifting arms and the cot base during powered loading and unloading.• Return damaged batteries to a service center for recycling.  Do not dispose of the battery.• To reduce the risk of electric shock, do not remove the battery when Power-LOAD in operation.• Before servicing Power-LOAD, disconnect the vehicle battery, press the main power button to turn the unit off, and then place the trolley into the loading position.• Do not press the main power button to turn the unit off during normal use as it will prevent battery charging.• To prevent the cot frame from coming out of the rail jaws, the space between the rail clamp and the rail stationary jaw must never exceed 1 in (2.5 cm).  To prevent the cot from coming out of the rail jaws and causing possible injury to the patient or user, the rail clamp must not overlap the red adjustment limit label on the rail tube.• The rail clamp fastener closes with a strong spring action.  To avoid injury, do not use hand or fingers to press the manual trolley release button when the rail jaws are open.• Loading and/or unloading an occupied cot into a vehicle requires a minimum of two (2) trained operators.• Make sure that all occupants enter the vehicle patient compartment after the Power-LOAD compatible cot has been loaded into the vehicle patient compartment.  • As the cot is unlocked for removal from the vehicle patient compartment, the Power-LOAD lifting arms will slightly raise the cot. If the lifting arms do not raise the cot, then the operators must be ready to accept the entire weight of the cot and patient to avoid injury. • When unloading the cot, ensure that the cot wheels are on the ground before lowering the arms. • When unloading a cot from the vehicle patient compartment while Power-LOAD is experiencing a power loss or system error, the operators must be ready to accept the entire weight of the cot and patient.• Removing a cot from a vehicle for repair requires a minimum of two (2) trained operators.• Always press the main power button to turn the unit off before service or cleaning.• Use any appropriate personal safety equipment, such as goggles or respirators, to avoid the risk of inhaling contagion.  • SOME CLEANING PRODUCTS ARE CORROSIVE IN NATURE AND MAY CAUSE DAMAGE TO THE PRODUCT IF USED IMPROPERLY.  If the products described above are used to clean Stryker patient care equipment, measures must be taken to insure the units are wiped with clean water and thoroughly dried following cleaning.  Failure to properly rinse and dry the units will leave a corrosive residue on the surface of the units, possibly causing premature corrosion of critical components. • To avoid the risk of injury, replace Power-LOAD if it has been involved in an accident.  A fastener that has been involved in a accident may be damaged, possibly causing failure to operate properly. CAUTION• Changes or modifications to the Power-LOAD system not expressly approved by Stryker could void the user’s authority to operate the system.• This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer-ence when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their expense.• When installing the anchor assembly, ensure that the wires rest inside of the floor plate assembly channel and are not pinched by the anchor assembly.• When installing the transfer assembly, slowly slide the transfer assembly to avoid breaking the cot inductive charge housing.• To avoid the risk of vehicle damage, be aware of items around your selected drill hole locations during installation.• The manual overrides allow the Power-LOAD system to move freely.• Possible fire hazard when used with oxygen administering equipment of other than nasal, mask or 1/2 bed length tent type.  Oxygen tent should not extend below mattress support level nor be used around Power-LOAD or a Power-LOAD compatible cot.
www.stryker.com 6390-009-001 REV B 13Return To Table of ContentsSummary of Safety PrecautionsPINCH POINTSFigure 3:  Pinch Points• To avoid the risk of equipment damage, do not slam the cot into the trolley when loading.• To avoid the risk of equipment damage, do not push the cot into the vehicle patient compartment until the cot base is fully retracted.• Do not let go of the manual release until the cot locks into position at the head end. If you let go too early, then the cot base may prevent the cot from properly locking into Power-LOAD.• DO NOT STEAM CLEAN OR ULTRASONICALLY CLEAN THE UNIT.• Maximum water temperature should not exceed 180°F/82°C.• Allow unit to air dry prior to use.• Failure to comply with these instructions may invalidate any/all warranties. CAUTION (CONTINUED)
14 6390-009-001 REV B www.stryker.comReturn To Table of ContentsVehicle Cot Compatibility InformationThe Stryker Model 6390 Power-LOAD system is designed to be fully compatible with cots with the Power-LOAD compatible option only.  Vehicle cots which currently meet these specifications are:• Model 6085 Performance-PRO™ XT with the Power-LOAD option (compatibility kit - 6085-700-010)• Model 6086 Performance-PRO™ XT with the Power-LOAD option (compatibility kit - 6086-700-001)• Model 6500 Power-PRO™ XT with the Power-LOAD option (compatibility kit - 6500-700-049)• Model 6506 Power-PRO™ XT with the Power-LOAD option (compatibility kit - 6506-700-001)• Model 6510 Power-PRO™ IT with the Power-LOAD option (compatibility kit - 6510-700-001)• Model 6516 Power-PRO™ IT with the Power-LOAD option (compatibility kit - 6516-700-001) WARNING• Power-LOAD is designed to be compatible with the Performance-PRO XT, Power-PRO XT, and Power-PRO IT cots with the Power-LOAD option only.  In certain situations, you can use Power-LOAD as a standard antler for most X-frame cots, but a rail clamp assembly is required for all cots without the Power-LOAD option. • It is the responsibility of the cot operator to ensure that the cot being used in the Stryker Model 6390 Power-LOAD system is a Power-LOAD compatible cot.  Injury may result if a non-compatible cot is used in the Stryker Model 6390 Power-LOAD system.
www.stryker.com 6390-009-001 REV B 15Return To Table of ContentsInstallation Setup ProceduresFLOOR PLATE ASSEMBLY INSTALLATION COMPONENT CHECKLISTFollow this component checklist to ensure that you have all of the required components to properly install the Power-LOAD system.  For installation instructions, see “Installing the Floor Plate (with a Wood Floor)” on page 21.  Figure 4:  Floor Plate Installation Kit Components (6390-001-055)
16 6390-009-001 REV B www.stryker.comReturn To Table of ContentsInstallation Setup ProceduresPOWER-LOAD ASSEMBLY INSTALLATION COMPONENT CHECKLISTFollow this component checklist to ensure that you have all of the required components to properly install the Power-LOAD system.  For installation instructions, see “Installing the Power-LOAD System” on page 27.Figure 5:  Power-LOAD Assembly Installation Kit Components (6390-001-054)
www.stryker.com 6390-009-001 REV B 17Return To Table of ContentsInstallation Setup ProceduresOPTIONAL WHEEL GUIDE ASSEMBLY INSTALLATION COMPONENT CHECKLISTFollow this component checklist to ensure that you have all of the required components to properly install the Power-LOAD system.  For installation instructions, see “Installing The Optional Wheel Guide” on page 34.Figure 6:  Optional Wheel Guide Assembly Installation Kit Components (6390-027-000)
18 6390-009-001 REV B www.stryker.comReturn To Table of ContentsQUALITY SYSTEM REGULATIONThe U.S. Food and Drug Administration (FDA) Code of Federal Regulations (CFR) Title 21 provides guidance regarding the installation of devices, such as Power-LOAD.  To comply with these federal regulations, each device must be verified to have been properly installed by trained* individuals by following the inspection criteria in the “Power-LOAD Installation Checklist” on page 38. This document must be maintained for a minimum of 7 years for each serial number/installation. *the Power-LOAD installation facility must maintain their own training records showing that the installer was qualified.CFR 21 SEC. 820.170 INSTALLATION(a)  Each manufacturer of a device requiring installation shall establish and maintain adequate installation and inspection instructions, and where appropriate test procedures. Instructions and procedures shall include directions for ensuring proper installation so that the device will perform as intended after installation. The manufacturer shall distribute the instructions and procedures with the device or otherwise make them available to the person(s) installing the device.(b)  The person installing the device shall ensure that the installation, inspection, and any required testing are performed in accordance with the manufacturer’s instructions and procedures and shall document the inspection and any test results to demonstrate proper installation.CFR 21 SEC. 820.180 GENERAL REQUIREMENTSAll records required by this part shall be maintained at the manufacturing establishment or other location that is reasonably accessible to responsible officials of the manufacturer and to employees of FDA designated to perform inspections. Such records, including those not stored at the inspected establishment, shall be made readily available for review and copying by FDA employee(s). Such records shall be legible and shall be stored to minimize deterioration and to prevent loss. Those records stored in automated data processing systems shall be backed up.(a)  Confidentiality. Records deemed confidential by the manufacturer may be marked to aid FDA in determining whether information may be disclosed under the public information regulation in part 20 of this chapter.(b)  Record retention period. All records required by this part shall be retained for a period of time equivalent to the design and expected life of the device, but in no case less than 2 years from the date of release for commercial distribution by the manufacturer. WARNING• Improper installation can result in injury.  Install the Stryker Model 6390 Power-LOAD system as described in this manual.  Ensure that, at a minimum, your configuration with Power-LOAD is tested to meet AMD Standard 004.• Take special precautions regarding electromagnetic compatibility (EMC) when using medical electrical equipment like Power-LOAD.  Install and place Power-LOAD into service according to the EMC information in this manual. Portable and mobile RF communications equipment can affect the function of Power-LOAD.Quality System Regulation for Installation
www.stryker.com 6390-009-001 REV B 19Return To Table of ContentsSelect your configuration (see Figure 7, Figure 8, or Figure 9 for reference).  Note:  All measurements are shown in inches.1  Choose one hole to drill Ø 1/2 in (1.3 cm) through for electrical input.2  Router depth to be 9/16 in (1.4 cm) for the floor plate pocket.3  Floor plate may be cut shorter to either indicated length.4  Note:  The foot end of the floor plate should be 2-3/4 in (7 cm) from the location where the door sill first drops off.• Floor plate pocket width will be approximately 2.563 in (6.5 cm).• Bolts (not included) for the floor plate (select one bolt location from each of the five bolt patterns) are to be 3/8-16 UNC flat head cap screws, ASTM-F835 or SAE grade 8.  Each bolt should have a flat washer, lock washer, and nut.• Each bolt and supporting structure underneath must be able to withstand 2750 lb (998 kg) in upward tension and 600 lb (272 kg) in shear in all horizontal directions.• Each bolt must be installed with a minimum of 40 ft-lb torque.• Bolts for the antler and rail clamp plates are to be 3/8-16 UNC socket head cap screws.Note:  Antler and rail clamp plates are optional.• Choose an unused bolt hole to drill through Ø 9/16 in (1.4 cm) for drain hole toward the foot end.  Do not use the front four drill holes.• Electrical requirements:  12.8V-15.6V  , 15A breaker, 2 conductor 10 AWG cable.• Ensure that minimum clearance is provided from the captain’s seat.  Refer to KKK-A-1822F Federal Specification for the Star-of-Life Ambulance, section 3.10.4, for further guidance.• You must install the optional wheel guide (6390-027-000) for Type II ambulances (see page 34).Figure 7:  Power-LOAD Floor Plate with Single Standard Floor Mount Cot Fastener Floor Plate (Optional)SillSill Edge43213Floor Plate Installation Guidelines