Sun Microsystems Fire X4100 M2 Users Manual X4100/X4100 And X4200/X4200 Servers Installation Guide
X4200 M2 to the manual 63cc4e34-cce3-4202-ada5-e588d67adc3d
2015-02-02
: Sun-Microsystems Sun-Microsystems-Sun-Fire-X4100-M2-Users-Manual-489767 sun-microsystems-sun-fire-x4100-m2-users-manual-489767 sun-microsystems pdf
Open the PDF directly: View PDF .
Page Count: 50
Download | |
Open PDF In Browser | View PDF |
Sun Fire™ X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide Sun Microsystems, Inc. www.sun.com Part No. 819-1155-16 May 2007, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S. and in other countries. This document and the product to which it pertains are distributed under licenses restricting their use, copying, distribution, and decompilation. No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd. Sun, Sun Microsystems, the Sun logo, Java, AnswerBook2, docs.sun.com, Sun Fire,Sun Netra, and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and in other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and in other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun’s written license agreements. U.S. Government Rights—Commercial use. Government users are subject to the Sun Microsystems, Inc. standard license agreement and applicable provisions of the FAR and its supplements. DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, Etats-Unis. Tous droits réservés. Sun Microsystems, Inc. a les droits de propriété intellectuels relatants à la technologie qui est décrit dans ce document. En particulier, et sans la limitation, ces droits de propriété intellectuels peuvent inclure un ou plus des brevets américains énumérés à http://www.sun.com/patents et un ou les brevets plus supplémentaires ou les applications de brevet en attente dans les Etats-Unis et dans les autres pays. Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l’utilisation, la copie, la distribution, et la décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l’autorisation préalable et écrite de Sun et de ses bailleurs de licence, s’il y en a. Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de caractères, est protégé par un copyright et licencié par des fournisseurs de Sun. Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque déposée aux Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, Java, AnswerBook2, docs.sun.com, Sun Fire, Sun Netra, et Solaris sont des marques de fabrique ou des marques déposées de Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux Etats-Unis et dans d’autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc. L’interface d’utilisation graphique OPEN LOOK et Sun™ a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d’utilisation visuelle ou graphique pour l’industrie de l’informatique. Sun détient une license non exclusive de Xerox sur l’interface d’utilisation graphique Xerox, cette licence couvrant également les licenciées de Sun qui mettent en place l’interface d ’utilisation graphique OPEN LOOK et qui en outre se conforment aux licences écrites de Sun. LA DOCUMENTATION EST FOURNIE "EN L’ÉTAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION PARTICULIERE OU A L’ABSENCE DE CONTREFAÇON. Contents Preface 1. v Setting Up the Server Hardware Installation Overview 1 1 Installing the Server Into a Rack With Optional Slide Rails Disassembling the Slide Rails Before Installation 3 Installing the Mounting Brackets Onto the Server Attaching the Slide-Rail Assemblies to the Rack 4 5 Installing the Server Into the Slide Rail Assemblies Installing the Cable Management Assembly Attaching and Routing Cables 6 7 11 Verifying Operation of the Slide Rails and CMA Cabling 2 12 13 Powering On and Off the Server 16 Applying Standby Power for Initial Service Processor Configuration Powering On Main Power Mode Shutting Down Main Power Mode 16 17 17 iii 2. Setting Up the Server Software 19 Introduction to the Integrated Lights Out Manager Connecting to the ILOM Service Processor 19 21 Connecting to ILOM Using a Serial Connection 21 Connecting to ILOM Using an Ethernet Connection 3. 23 Setting Up Platform Operating System and Driver Software 29 Configuring the Preinstalled Solaris 10 Operating System 31 Before You Begin 31 Installation Worksheet 32 Selecting Your Console Output 35 Configuring the Preinstalled Solaris 10 Operating System Solaris 10 User Documentation 39 Downloading Solaris 10 OS Software Solaris 10 OS Training Index iv 39 39 41 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 36 Preface This Installation Guide contains procedures for installing the server in a rack, cabling, and powering on the server. It also contains procedures for connecting to the service processor administrator account. Links to documentation for configuring the preinstalled Solaris 10 software or for installing other supported operating systems are also included. Related Documentation For a description of the document set, see the Where To Find Documentation sheet that is packed with your system and available at the product's documentation site. Refer to the following URL, then navigate to your product: http://www.sun.com/products-nsolutions/hardware/docs/Servers/x64_servers/index.html This site also contains translated versions of some of these documents in French, Simplified Chinese, Traditional Chinese, Korean, and Japanese. English documentation is revised more frequently and might be more up-to-date than the translated documentation. For all Sun documentation, refer to: http://www.sun.com/documentation For Solaris and other software documentation, refer to: http://docs.sun.com v Product Updates For product updates that you can download for the Sun Fire X4100 or X4200 servers, please visit the following Web site: http://www.sun.com/servers/entry/x4100/downloads.jsp This site contains updates for firmware and drivers, as well as CD-ROM .iso images. Using UNIX Commands This document might not contain information about basic UNIX® commands and procedures such as shutting down the system, booting the system, and configuring devices. Refer to the following for this information: ■ Software documentation that you received with your system ■ Solaris™ Operating System documentation, which is at: http://docs.sun.com Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources. Sun will not be responsible or liable for any actual or alleged damage or loss caused by or in connection with the use of or reliance on any such content, goods, or services that are available on or through such sites or resources. vi Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Typographic Conventions Typeface* Meaning Examples AaBbCc123 The names of commands, files, and directories; on-screen computer output Edit your.login file. Use ls -a to list all files. % You have mail. AaBbCc123 What you type, when contrasted with on-screen computer output % su Password: AaBbCc123 Book titles, new words or terms, words to be emphasized. Replace command-line variables with real names or values. These are called class options. You must be superuser to do this. To delete a file, type rm filename. * The settings on your browser might differ from these settings. Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions. You can submit your comments by going to: http://www.sun.com/hwdocs/feedback Please include the title and part number of your document with your feedback: Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide, part number 819-1155-16 Preface vii viii Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 CHAPTER 1 Setting Up the Server Hardware This chapter contains the following topics: ■ ■ ■ ■ “Installation Overview” on page 1 “Installing the Server Into a Rack With Optional Slide Rails” on page 2 “Cabling” on page 13 “Powering On and Off the Server” on page 16 Note – The information in this book applies to all Sun Fire™ X4100/X4100 M2 and X4200/X4200 M2 servers, unless otherwise noted. Installation Overview After unpacking your server, perform the following tasks, which are described in the documentation as indicated: 1. If desired, install the server into a rack using orderable slide-rails. See “Installing the Server Into a Rack With Optional Slide Rails” on page 2. 2. Connect all cables, peripherals, and power cords. See “Cabling” on page 13 for an illustration of the server’s back panel connector ports. 3. Power on and boot the server as described in “Powering On and Off the Server” on page 16. 4. Connect to the service processor as described in Chapter 2. 1 5. Configure the preinstalled Solaris™ operating system or install a supported operating system of your choice. For details, refer to one of the following: ■ “Configuring the Preinstalled Solaris 10 Operating System” on page 36 ■ Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Operating System Installation Guide, 819-1158 ■ Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Windows Operating System Installation Guide, 819-4346 6. Customize your server as needed. For details, refer to the “System Management” section of the online information system or the Integrated Lights-Out Manager Administration Guide, 820-0280-10. Installing the Server Into a Rack With Optional Slide Rails To install your server in a four-post rack using the orderable slide-rail option, follow these procedures. These slide-rails are compatible with a wide range of equipment racks that meet the following standards: ■ Four-post structure (mounting at both front and rear). Two-post racks are not compatible. ■ Rack horizontal opening and unit vertical pitch conforming to ANSI/EIA 310-D-1992 or IEC 60927 standards. ■ Distance between front and rear mounting planes between 610 mm and 915 mm (24 inches to 36 inches). ■ Clearance depth (to front cabinet door) in front of front rack mounting plane at least 25.4 mm (1 inch). ■ Clearance depth (to rear cabinet door) behind front rack mounting plane at least 800 mm (31.5 inches) or 700 mm (27.5 inches) without cable management arm. ■ Clearance width (between structural supports and cable troughs) between front and rear mounting planes at least 456 mm (18 inches). Note – Although the Sun Fire X4100/X4100 M2 server is pictured in the illustrations in this section, these procedures also apply to the Sun Fire X4200/X4200 M2 server. Caution – Always load equipment into a rack from the bottom up so that it will not become top-heavy and tip over. Deploy your rack’s anti-tilt bar to prevent the rack from tipping during equipment installation. 2 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Disassembling the Slide Rails Before Installation Use this procedure to remove the mounting brackets from the slide-rail assemblies. 1. Unpack the slide-rails. 2. Locate the slide-rail lock at the front of one of the slide-rail assemblies, as shown in FIGURE 1-1. 3. Squeeze and hold the tabs at the top and bottom of the lock while you pull the mounting bracket out of the slide-rail assembly, until it reaches the stop. See FIGURE 1-1. 4. Pull the mounting bracket release button toward the front of the mounting bracket, as shown in FIGURE 1-1, and simultaneously withdraw the mounting bracket from the slide-rail assembly. 5. Repeat the procedure for the remaining slide rail assembly. Mounting bracket release button Slide-rail lock FIGURE 1-1 Disassembling the Slide-Rail Before Installation Chapter 1 Setting Up the Server Hardware 3 Installing the Mounting Brackets Onto the Server Use this procedure to install the mounting brackets onto the sides of the server. 1. Position a mounting bracket against the chassis so that the slide-rail lock is at the server front, and the three keyed openings on the mounting bracket are aligned with the three locating pins on the side of the chassis. See FIGURE 1-2. Mounting-bracket clip Chassis front Slide-rail lock FIGURE 1-2 Mounting bracket Aligning the Mounting Bracket With the Server Chassis 2. With the heads of the three chassis locating pins protruding though the three keyed openings in the mounting bracket, pull the mounting bracket toward the front of the chassis until the mounting-bracket clip locks into place with an audible click. See FIGURE 1-2. 3. Verify that all three locating pins are trapped in the keyed openings and that the rear locating pin has engaged the mounting-bracket clip. See FIGURE 1-2. 4. Repeat the procedure to install the remaining mounting bracket on the other side of the server. 4 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Attaching the Slide-Rail Assemblies to the Rack Use this procedure to install the slide-rail assemblies to the rack. 1. Position a slide-rail assembly in your rack so that the brackets at each end of the slide-rail assembly are on the outside of the front and rear rack posts. See FIGURE 1-3. 2. Attach the slide-rail assembly to the rack posts. The method used to attach the slide-rails varies depending on the type of rack: ■ If your rack has threaded mounting holes in the rack posts, first determine whether the threads are metric or standard, then insert the correct mounting screws through the slide-rail brackets and into the threaded holes. ■ If your rack does not have threaded mounting holes, insert the mounting screws through both the slide-rail brackets and rack posts, then secure them with the caged nuts. Rack post Slide-rail assembly bracket on outside of rack post Slide-rail assembly with mounting bracket removed FIGURE 1-3 Slide-Rail Assembly Mounting to Rack Post 3. Repeat the procedure for the remaining slide rail assembly. Chapter 1 Setting Up the Server Hardware 5 Installing the Server Into the Slide Rail Assemblies Use this procedure to install the server chassis, with mounting brackets, into the slide-rail assemblies that are mounted to the rack. Caution – This procedure requires a minimum of two people because of the weight of the server. Attempting this procedure alone could result in equipment damage or personal injury. 1. Push the slide-rails into the slide-rail assemblies as far as possible. 2. Raise the server so that the rear ends of the mounting brackets are aligned with the slide-rail assemblies that are mounted in the equipment rack. See FIGURE 1-4. 3. Insert the mounting brackets into the slide-rails, then push the server into the rack until the mounting brackets encounter the slide-rail stops (approximately 12 inches or 30 cm). Slide-rail assembly mounted on rack post Mounting bracket inserted into slide-rail Slide-rail release button FIGURE 1-4 6 Inserting the Server With Mounting Brackets Into the Slide-Rails Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Slide-rail locks 4. Simultaneously pull and hold the slide rail release buttons on each mounting bracket while you push the server into the rack. See FIGURE 1-4. Continue pushing until the slide-rail locks on the front of the mounting brackets engage the slide-rail assemblies. Caution – Verify that the server is securely mounted in the rack and that the sliderails locks are engaged with the mounting brackets before continuing. Installing the Cable Management Assembly Use this procedure to install an optional cable management assembly (CMA). 1. Unpack the CMA parts. 2. Take the CMA to the rear of the equipment rack and ensure that you have adequate room to work around the rear of the server. Note – References to “left” or “right” in this procedure assume that you are facing the rear of the equipment rack. 3. Locate the CMA rail extension and insert it into the left slide-rail until the extension locks into place with an audible click. See FIGURE 1-5. Left slide-rail CMA rail extension FIGURE 1-5 Inserting the CMA Rail Extension Into the Rear of the Left Slide-Rail Chapter 1 Setting Up the Server Hardware 7 4. Verify that the CMA rail extension engages the slide-rail, as shown in FIGURE 1-6. CMA rail extension Left slide-rail FIGURE 1-6 Detail of CMA Rail Extension Inserted Into the Left Slide-Rail Note – Support the CMA in the remaining installation steps. Do not allow the assembly to hang by its own weight until it is secured by all three of the attachment points. 5. Insert the CMA’s mounting bracket connector into the right slide-rail until the connector locks into place with an audible click. See FIGURE 1-7. 8 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Right slide-rail CMA mounting bracket FIGURE 1-7 Inserting the CMA Mounting Bracket Into the Rear of the Right Slide-Rail 6. Insert the right CMA slide-rail connector into the right slide-rail assembly until the connector locks into place with an audible click. See FIGURE 1-8. Right sliderail assembly CMA slide-rail connector FIGURE 1-8 Inserting CMA Slide-Rail Connector Into Rear of Right Slide-Rail Assembly Chapter 1 Setting Up the Server Hardware 9 7. Insert the remaining CMA arm connector into the plastic cutout on the CMA rail extension, which you installed to the left slide-rail in Step 3. See FIGURE 1-9. CMA extension arm (on left slide-rail) Tab FIGURE 1-9 CMA arm connector Connecting the CMA Arm to Rail Extension Connector 8. Gently press the tab in the direction indicated in FIGURE 1-9 to open the cutout enough to insert the connector. Once you pass the connector through the cutout, release the tab to lock the connector in place. 9. Position the cable hangers in the appropriate mounting holes in the CMA and snap them into place. See FIGURE 1-10. 10 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 CMA cable hanger FIGURE 1-10 CMA arm Installing CMA Cable Hangers Attaching and Routing Cables Use this procedure to attach cables to your server and route them through the CMA. 1. Refer to “Cabling” on page 13 for an illustration of the server back panel ports and a procedure for installing cables to your server. 2. Install cables to your server, as required. 3. Route the cables through the CMA cable hangers. Chapter 1 Setting Up the Server Hardware 11 Verifying Operation of the Slide Rails and CMA Use this procedure to ensure that the slide-rails and CMA are operating correctly. Note – Two people are recommended for this procedure: one to move the server in and out of the rack and one to observe the cables and CMA. 1. Slowly pull the server out of the rack until the slide-rails reach their stops. 2. Inspect the attached cables for any binding or kinks. 3. Verify that the CMA extends fully and does not bind in the slide-rails. 4. Push the server back into the rack, as described below. When the server is fully extended, you must release two sets of slide-rail stops to return the server to the rack: a. The first set of stops are levers, located on the inside of each slide-rail, just behind the rear panel of the server. These levers are labeled “PUSH.” Push in both levers simultaneously and slide the server toward the rack. The server will travel approximately 15 inches (38 cm) and stop. Verify that the cables and the CMA retract without binding before continuing. b. The second set of stops are the slide-rail release buttons, located near the front of each mounting bracket. See FIGURE 1-4. Simultaneously push or pull both of the slide-rail release buttons and push the server completely into the rack until both slide-rail locks engage. 5. Adjust the cable hangers and CMA as required. 6. Continue with “Cabling” on page 13. 12 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Cabling Attach cables to the back panel connectors of your server as required. See FIGURE 1-11 or FIGURE 1-12. AC power connectors (2) Video connector FIGURE 1-11 Ethernet port NET MGT Gigabit Ethernet ports (4) USB connectors (2) SERIAL MGT port Sun Fire X4100/X4100 M2 Server Back Panel Ethernet port NET MGT Gigabit Ethernet ports (4) NET MGT AC power connectors (2) Video connector FIGURE 1-12 SERIAL MGT port USB connectors (2) Sun Fire X4200/X4200 M2 Server Back Panel 1. If desired, connect a USB keyboard cable to a USB connector. 2. If desired, connect a USB mouse cable to a USB connector. Chapter 1 Setting Up the Server Hardware 13 3. If desired, connect a video monitor cable to the video connector. Note – Keyboard, mouse, and video are optional with an operating system that supports headless operation. Note – The system console supports only a screen resolution of 1024 by 768 and a color depth of 24 bits. This limitation is necessary to support video redirection by the Integrated Lights Out Manager (ILOM). 4. Connect Ethernet cables to the “NET” connectors as required for your Gigabit Ethernet or management network. Note the following guidelines regarding the Ethernet (LAN) ports: ■ The port labeled “NET MGT” is a 10/100 Ethernet port that can connect your system to a management network. ■ The ports labeled “NET 0” through “NET 3” are Gigabit Ethernet ports. The order in which the BIOS detects the Ethernet ports during bootup and the corresponding drivers that control those ports are listed below. ■ Sun Fire X4100/X4200 servers: i. NET 0 (Intel NIC 0) ii. NET 1 (Intel NIC 1) iii. NET 2 (Intel NIC 2) iv. NET 3 (Intel NIC 3) ■ Sun Fire X4100 M2/X4200 M2 servers: i. NET 0 (Nvidia CK8-04 NIC) ii. NET 1 (Nvidia IO-04 NIC) iii. NET 2 (Intel NIC) iv. NET 3 (Intel NIC) See “Connecting to the ILOM Service Processor” on page 21 for additional information about setting up the service processor for remote system management. 14 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 5. If desired, connect an RJ-45 serial port cable to the “SERIAL MGT” connector. Note the following considerations for the serial port and serial port cabling: ■ The default serial port speed is 9600 baud with no flow control. ■ These servers use the same pinout as the RJ45 port on the RSC/ALOM/ALOM Plus cards on Sun Netra™ and other Sun Fire systems. ■ There is a compatible Sun RJ45-to-DB9 adapter shipped with the server, part number 530-3100. ■ An alternative, compatible cable is the Cisco 72-3383-01 console cable. 6. Continue with “Powering On and Off the Server” on page 16. Chapter 1 Setting Up the Server Hardware 15 Powering On and Off the Server You have to apply only standby power to the server at this point so that you can perform initial configuration o f the service processor. Procedures for powering on to main power mode and for shutting down from main power mode are also included in this section. Applying Standby Power for Initial Service Processor Configuration Use this procedure to apply standby power to the service processor (SP) before initial configuration. Caution – Do not operate the server without all fans, component heatsinks, air baffles, and the cover installed. Severe damage to server components can occur if operated without adequate cooling mechanisms. 1. Connect grounded AC power cords to the AC power connectors on the back panel of the server and to grounded AC power outlets. In standby power mode, the Power/OK LED on the front panel flashes, indicating that the SP is working. See FIGURE 1-13 or FIGURE 1-14 for the LED location. Note – At this point, standby power is supplied only to the Graphics Redirect and Service Processor (GRASP) board and power supply fans. You can proceed to Chapter 2 to begin initial configuration. Do not apply main power to the rest of the server until you are ready to install a platform operating system. 2. Continue with initial software setup tasks, as described in Chapter 2. 16 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Powering On Main Power Mode ● To power on main power for all server components: a. Verify that power cords have been connected and that standby power is on. In standby power mode, the Power/OK LED on the front panel flashes. See FIGURE 1-13 or FIGURE 1-14. b. Use a ballpoint pen or other stylus to press and release the recessed Power button on the server front panel. When main power is applied to the full server, the Power/OK LED next to the Power button lights and remains lit. Power/OK LED FIGURE 1-13 Sun Fire X4100/X4100 M2 Server Front Panel Power/OK LED FIGURE 1-14 Power button Power button Sun Fire X4200/X4200 M2 Server Front Panel Shutting Down Main Power Mode ● To power off the server from main power mode, use one of the following two methods: ■ Graceful shutdown: Use a ballpoint pen or other stylus to press and release the Power button on the front panel. This causes Advanced Configuration and Power Interface (ACPI) enabled operating systems to perform an orderly shutdown of the operating system. Servers not running ACPI-enabled operating systems will shut down to standby power mode immediately. Chapter 1 Setting Up the Server Hardware 17 ■ Emergency shutdown: Press and hold the Power button for four seconds to force main power off and enter standby power mode. When main power is off, the Power/OK LED on the front panel will begin flashing, indicating that the server is in standby power mode. Caution – To completely power off the server, you must disconnect the AC power cords from the back panel of the server. 18 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 CHAPTER 2 Setting Up the Server Software This chapter describes the tasks for initial setup of the server’s service processor and Integrated Lights Out Manager™ software. This chapter contains these topics: ■ ■ ■ “Introduction to the Integrated Lights Out Manager” on page 19 “Connecting to the ILOM Service Processor” on page 21 “Setting Up Platform Operating System and Driver Software” on page 29 Introduction to the Integrated Lights Out Manager The Integrated Lights Out Manager (ILOM) provides powerful tools for managing your server. FIGURE 2-1 Integrated Lights Out Manager Login Page 19 ILOM consists of four components, three of which are on your host server and one that is on the client system that accesses your host server. The four components are as follows: ■ ■ ILOM SP hardware. Your server is equipped with a Graphics Redirect and Service Processor (GRASP) board that performs the following functions: ■ Monitors the status and configuration of field-replaceable components of your server, such as fans, disk drives, and power supplies. ■ Provides serial and Ethernet connections to external terminals or local area networks (LANs). ILOM SP firmware. Preinstalled on the GRASP board is a library of system management firmware applications. This ILOM firmware is operating system independent. These firmware applications provide the following system management interfaces into your server: ■ ■ ■ ■ A web-based graphical interface A Secure Shell (SSH) command-line interface An IPMI v2.0 command interface A Simple Network Management Protocol (SNMP) v1, v2c, or v3 interface These interfaces call the same underlying system management functions on your GRASP board, so you can choose to work with one or more of these ILOM interfaces to integrate with the other management interfaces running in your data center. ■ Remote Console application. The Remote Console application allows remote clients to view the graphical console of your host server as though they were directly attached to its video connector. The Remote Console is a mirror of the 1024x768 output from the server’s VGA video connector. The remote keyboard, mouse, CD drive, or diskette drive will appear as standard USB devices. Note – The Remote Console application is not required on the client systems, but a web browser and Sun Java™ runtime environment version 5.0 or later are required on the client systems. You can download Java free from http://java.sun.com. ■ Client-side Secure Shell application. To access the ILOM SP through a remote Secure Shell (SSH), you must install a Secure Shell communications application on the remote client system (server, workstation, or laptop). Many Secure Shell communications applications are available from commercial or open-source distribution. Refer to http://www.openssh.org for information about opensource client-side SSH applications. Sun Microsystems™ has configured the ILOM hardware and firmware on your server to reflect the most common default settings used in the field. It is unlikely that you will need to change these defaults. 20 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Connecting to the ILOM Service Processor There are two methods for connecting to the ILOM SP to perform initial setup and configuration. Use the procedure that you prefer: ■ ■ “Connecting to ILOM Using a Serial Connection” on page 21 “Connecting to ILOM Using an Ethernet Connection” on page 23 Connecting to ILOM Using a Serial Connection Use this procedure to establish a serial connection to the ILOM SP so that you can perform initial configuration of ILOM. Note – This procedure assumes that you have already completed the hardware setup and have applied standby power to your server, as described in Chapter 1. 1. Verify that your terminal, laptop, or terminal server is operational. 2. Configure that terminal device or the terminal emulation software running on a laptop or PC to the following settings: ■ ■ ■ ■ 8N1: eight data bits, no parity, one stop bit 9600 baud Disable hardware flow control (CTS/RTS) Disable software flow control (XON/XOFF) 3. Connect a serial cable from the RJ-45 SERIAL MGT port on the server’s back panel to a terminal device. See FIGURE 1-11 or FIGURE 1-12 for the location of this port. Chapter 2 Setting Up the Server Software 21 4. Press Enter on the terminal device to establish a connection between that terminal device and the ILOM SP. The SP eventually displays a login prompt, such as the following example: SUNSP0003BA84D777 login: In this example login prompt: ■ The string SUNSP is the same for all SPs. ■ 0003BA84D777 is the Ethernet MAC address of the particular SP. This will be different for each server. 5. Log in to the ILOM. a. Type the default user name: root b. Type the default password: changeme. Once you have successfully logged in, the SP displays its default command prompt: -> You can now run CLI commands to configure ILOM for the server’s user accounts, network settings, access lists, alerts, and so on. For detailed instructions on CLI commands, see the Integrated Lights-Out Manager Administration Guide, 819-1160. For instructions on configuring static network settings using the CLI, see “Configuring Static IP Addresses Using the CLI” on page 27. 6. To start the serial console, you can type: cd /SP/console start Note – You can switch back to the SP CLI from the serial console by entering the Esc ( key sequence. 7. After configuring the server, continue with “Setting Up Platform Operating System and Driver Software” on page 29. 22 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Connecting to ILOM Using an Ethernet Connection To access the full range of ILOM functionality such as the graphical user interface (GUI), you must connect a LAN to the Ethernet port and configure your Ethernet connection. ILOM supports Dynamic Host Configuration Protocol (DHCP) and static IP addressing. ■ To configure using DHCP, see “Configuring ILOM Ethernet Settings Using DHCP” on page 23. ■ To configure using a static IP address, see “Configuring ILOM Using Static Ethernet Settings” on page 26. Configuring ILOM Ethernet Settings Using DHCP Note – This procedure assumes that you have already completed the hardware setup and have applied standby power for your server, as described in Chapter 1. 1. Verify that your DHCP server is configured to accept new media access control (MAC) addresses by checking with your system administrator. 2. Connect an Ethernet cable to the server’s RJ-45 NET MGT Ethernet port. See FIGURE 1-11 or FIGURE 1-12. If the ILOM SP is not using static IP addresses, it broadcasts a DHCPDISCOVER packet with the ID of its MAC address. A DHCP server on your LAN returns a DHCPOFFER packet containing an IP address and other information. The ILOM SP then manages its “lease” of that IP address that was assigned to it by the DHCP server. 3. Obtain the ILOM SP IP address from one of the following locations. Record the IP address for future reference. ■ CLI commands. The SP has a serial port to which you can attach a terminal device. If you log in to the SP and enter the CLI command show /SP/network, the SP displays the current IP address. ■ The system BIOS setup screen. Press F2 during bootup, then choose Advanced IPMI 2.0 Configuration → Set LAN Configuration → IP address. ■ DHCP server log files. If you use this method, use Step a through Step c below. Otherwise, skip to Step 4. Chapter 2 Setting Up the Server Software → 23 a. Identify the MAC address of the ILOM SP from one of the following locations and write it down: ■ CLI commands. The SP has a serial port to which you can attach a terminal device. If you log in to the SP and type the CLI command show /SP/network, the SP displays the current MAC address. ■ The Customer Information Sheet that is shipped with your server. ■ The system BIOS setup screen. Press F2 during bootup, then choose Advanced → IPMI 2.0 Configuration → Set LAN Configuration → MAC address. b. Log in to your DHCP server and view its DHCP log file. Note – Different DHCP server applications running on different operating systems store these log files in different locations. Consult your DHCP system administrator to locate the correct path to the log file. c. Identify the IP address in the log file that corresponds to the MAC address of your ILOM SP. Typically, DHCP log file entries are individual lines with the following commaseparated fields: ID, Date, Time, Description, IP Address, Host Name, MAC Address Locate the MAC address of your ILOM SP in the MAC Address (seventh) field of the correct DHCP file entry and record the corresponding value of the IP Address (fifth) field. This is the IP address that you must use to access the system management firmware applications on your ILOM SP. 4. Open a session to the ILOM SP using the IP address that you obtained in Step 3. You can use the CLI or the GUI interface. ■ To establish a Secure Shell (SSH) connection to the ILOM SP CLI, type the appropriate connection command in the SSH application. For example, to connect to the SP with the DHCP-assigned IP address of 129.144.82.20, type the following command: # ssh -l root 129.144.82.20 The default user name is root, which was included in the ssh command. When you are prompted, enter the default password for the SP, changeme. You can then enter commands to manage user accounts or to monitor the status of devices on your server. See the example in FIGURE 2-2. 24 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 FIGURE 2-2 ■ Opening a Session With an SSH Command-Line Interface To establish a connection to the ILOM SP web GUI, type the IP address of the ILOM SP in the browser locator box and press Enter. For example, if the IP address for your ILOM SP was 129.144.02.20, you would enter it as shown in FIGURE 2-3. The first GUI page prompts you for the default username, root, and the default password, changeme. FIGURE 2-3 Opening a Session With a Web GUI 5. After you have entered the user name and password in either the CLI or GUI, you can use the interface to configure your ILOM SP. For detailed instructions on configuring your system, see the Integrated Lights-Out Manager Administration Guide, 819-1160. 6. Continue with “Setting Up Platform Operating System and Driver Software” on page 29. Chapter 2 Setting Up the Server Software 25 Configuring ILOM Using Static Ethernet Settings As an alternative to having your DHCP server assign an IP address to your ILOM SP, you can also assign a static IP address to it. You can do this by using the web GUI, by using the CLI over the network or serial port, or by using the server’s BIOS Setup Utility. Use the procedure you prefer. ■ ■ ■ “Configuring Static IP Addresses Using the Web GUI” on page 26 “Configuring Static IP Addresses Using the CLI” on page 27 “Configuring Static IP Addresses Using the BIOS Setup Utility” on page 28 Configuring Static IP Addresses Using the Web GUI 1. Determine the current IP address of the ILOM SP from one of the following locations: ■ CLI command. The SP has a serial port to which you can attach a terminal device. If you log in to the SP and enter the CLI command show /SP/network, the SP displays the current IP address. ■ The system BIOS setup screen. Press F2 during bootup, then choose Advanced IPMI 2.0 Configuration → Set LAN Configuration → IP address. → 2. Connect to the ILOM SP through a web browser running on a remote system. 3. Log in to the web GUI using the default user name, root, and the default password, changeme. 4. Choose the Configuration tab and its Network tab to display information about the current network configuration of your ILOM SP. See FIGURE 2-4. 5. Select the Use the Following IP Address option and type your static IP address information. See the example in FIGURE 2-4. 26 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 FIGURE 2-4 Integrated Lights Out Manager Network Settings Page Configuring Static IP Addresses Using the CLI 1. Log into the CLI using SSH or by connecting to the serial port. To establish a Secure Shell (SSH) connection to the ILOM CLI, type the appropriate connection command in the SSH application. For example, to connect to the SP with the DHCP-assigned IP address of 129.144.82.20, you would type the following command: # ssh -l root 129.144.82.20 See the example in FIGURE 2-2. 2. Type the following commands, using your own addresses in place of the examples below: (The addresses shown in the commands below are examples.) cd /SP/network set pendingipaddress=129.144.82.26 set pendingipnetmask=255.255.255.0 set pendingipgateway=129.144.82.254 set pendingipdiscovery=static set commitpending=true Chapter 2 Setting Up the Server Software 27 Configuring Static IP Addresses Using the BIOS Setup Utility 1. Enter the BIOS Setup utility by pressing the F2 key while the system is booting up and performing the power-on self-test (POST). 2. When the BIOS Main menu screen is displayed, select Advanced. 3. From the Advanced menu screen, select IPMI 2.0 Configuration. 4. From the IPMI 2.0 Configuration screen, select LAN Configuration. 5. On the LAN Configuration screen, change the IP Assignment field to Static. 6. Type the static IP address in the IP Address field. You can also enter the subnet mask and default gateway settings in their respective fields. 7. Select Commit and press Return to commit the changes. 8. Select Refresh and press Return to see your new static IP settings displayed in the Current IP address in BMC field. 9. Press and release the right arrow key until the Exit menu screen is displayed. 10. Follow the instructions on the Exit menu screen to save your changes and exit the Setup utility. 28 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Setting Up Platform Operating System and Driver Software After configuring the ILOM SP with network settings, you can configure the preinstalled Solaris 10 operating system, or install a supported Linux or Windows platform operating system and drivers. ■ If you want to use the preinstalled Solaris 10 operating system, refer to “Configuring the Preinstalled Solaris 10 Operating System” on page 36. ■ For details about installing a supported Linux or Solaris OS and the required drivers, refer to Sun Fire X4100/X4200 Servers Operating System Installation Guide, 819-1158. ■ For details about installing a supported Windows OS and the required drivers, refer to Sun Fire X4100/X4200 Servers Windows Operating System Installation Guide, 819-4346. ■ For additional OS considerations specific to this server, refer to one of the following: ■ Sun Fire X4100/X4200 Servers Product Notes, 819-1162 ■ Sun Fire X4100 M2/X4200 M2 Servers Product Notes, 819-5038 Chapter 2 Setting Up the Server Software 29 30 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 CHAPTER 3 Configuring the Preinstalled Solaris 10 Operating System This chapter explains the steps for configuring the Solaris™ 10 Operating System (OS) that has been preinstalled on your server. The factory-installed version is Solaris 10 6/06 or later. Before You Begin Before you begin configuring the preinstalled OS, you need to do the following: 1. Perform initial configuration of the server’s Integrated Lights Out Manager (ILOM) Service Processor (SP) and determine the server’s network settings, as described in “Connecting to the ILOM Service Processor” on page 21. 2. Gather the information that you will need for the configuration, as listed in “Installation Worksheet” on page 32. 3. Select your console output. For details, see “Selecting Your Console Output” on page 35. 31 Installation Worksheet Use the worksheet in TABLE 1 to gather the information you need to configure the preinstalled Solaris 10 OS. You need to collect only the information that applies to your application. TABLE 1 Worksheet for Installation Your Answers: Defaults are noted with an asterisk. (*) Information for Installation Description or Example Language Choose from the list of available languages for the Solaris 10 software. English* Locale Choose your geographic region from the list of available locales. English (C - 7-bit ASCII)* Terminal Choose the type of terminal that you are using from the list of available terminal types. Network connection Is the system connected to a network? • Networked • Non-networked* DHCP Can the system use Dynamic Host Configuration Protocol (DHCP) to configure its network interfaces? • Yes • No* If you are not IP address using DHCP, note the network address: Subnet If you are not using DHCP, supply the IP address for the system. Example: 129.200.9.1 IPv6 If you are not using DHCP, is the system part of a subnet? If yes, what is the netmask of the subnet? Example: 255.255.0.0 255.255.0.0* Do you want to enable IPv6 on this machine? • Yes • No* Host name A host name that you choose for the system. Kerberos Do you want to configure Kerberos security on this • Yes machine? If yes, gather the following information: • No* Default Realm: Administration Server: First KDC: (Optional) Additional KDCs: 32 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 TABLE 1 Worksheet for Installation (Continued) Information for Installation Name service: if the system uses a name service, provide the following information. Name service Description or Example Which name service should this system use? Your Answers: Defaults are noted with an asterisk. (*) • • • • • NIS+ NIS DNS LDAP None* Domain name Provide the name of the domain in which the system resides. NIS+ and NIS Do you want to specify a name server or let the installation program find one? DNS Provide IP addresses for the DNS server. You must enter at least one IP address, but you can enter up to three addresses. You can also enter a list of domains to search when a DNS query is made. Search Domain: Search Domain: Search Domain: LDAP Provide the following information about your LDAP profile: Profile name: Profile server: If you specify a proxy credential level in your LDAP profile, gather this information: Proxy-Bind Distinguished Name: Proxy-Bind Password: Chapter 3 • Specify One • Find One* Configuring the Preinstalled Solaris 10 Operating System 33 TABLE 1 Worksheet for Installation (Continued) Your Answers: Defaults are noted with an asterisk. (*) Information for Installation Description or Example Default route Do you want to specify a default route IP address or let • Specify One the Solaris installation program find one? • Detect One The default route provides a bridge that forwards traffic • None* between two physical networks. An IP address is a unique number that identifies each host on a network. You have the following choices: • You can specify the IP address. An /etc/defaultrouter file is created with the specified IP address. When the system is rebooted, the specified IP address becomes the default route. • You can let the Solaris installation program detect an IP address. However, the system must be on a subnet that has a router that advertises itself by using the ICMP router discovery protocol. If you are using the command-line interface, the software detects an IP address when the system is booted. • You can choose None if you do not have a router or do not want the software to detect an IP address at this time. The software automatically tries to detect an IP address on reboot. Time zone How do you want to specify your default time zone? Root password Choose a root password for the system. 34 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 • Geographic region* • Offset from GM • Time zone file Selecting Your Console Output Unlike with SPARC® systems, you will not see the output of the preinstalled Solaris 10 image through a monitor when you power on the server. Instead, the output of the preinstalled image is directed to a serial console. GRUB, the open source boot loader, is the default boot loader. The boot loader is the first software program that runs after you power on a system. From the GRUB menu, you have the option of displaying the installation process to a VGA connection (video port) as shown here: ******************************************************************* * Solaris 10 11/06 s10x_u2wos_09a X86 * * Solaris failsafe * * Solaris 10 11/06 s10x_u2wos_09a X86 (VGA) * * * * * * * * * * * ******************************************************************* Note – The first line of the above figure shows the default startup mode. Example To display output to the video port, choose the Solaris 10 11/06 s10x_u2wos_09a X86 (VGA) option. Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 35 Configuring the Preinstalled Solaris 10 Operating System Note – Before you perform this procedure, you need to set up the service processor. If you have not done so, see “Before You Begin” on page 31. Use the information that you gathered in “Installation Worksheet” on page 32 as you perform the configuration. After configuring the ILOM SP, you can configure the preinstalled Solaris 10 operating system (OS) by using another system to connect to the server, or install a Linux or Windows platform operating system. The possible ways to do this are described here: ■ “To Connect to the Server Using the Service Processor’s IP Address” on page 37 If you use this method, you first need to determine the service processor’s IP address and the server must be connected to the network. ■ “To Connect to the Server Using a Terminal Program” on page 38 If you use this method, you do not need to determine the service processor’s IP address, but you will need to have a cable connection from the server to the serial port of a host system. ■ ■ 36 If you want to install a supported Windows or Linux OS and the required drivers, refer to the following: ■ For Windows: Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Windows Operating System Installation Guide, 819-4346 ■ For Linux (and Solaris): Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Operating System Installation Guide, 819-1158 For additional OS considerations specific to this server, refer to either of the following: ■ Sun Fire X4100/X4200 Servers Product Notes, 819-1162 ■ Sun Fire X4100 M2/X4200 M2 Servers Product Notes, 819-5038 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 ▼ To Connect to the Server Using the Service Processor’s IP Address Note – This procedure assumes that you have connected the server to your network through an Ethernet cable. 1. If you have not already done so, determine the service processor’s IP address: a. Power on main power to the platform by using a stylus to press the recessed Power button on the front panel. POST messages appear on your screen as the OS boots up. b. Initialize the BIOS Setup utility by pressing the F2 key while the system is performing the power-on self-test (POST). c. When the main BIOS screen is displayed, select Advanced. d. When the Advanced screen is displayed, select IPMI 2.0 Configuration. When the IPMI 2.0 Configuration screen is displayed, select the LAN Configuration menu item. e. Select the IP Address menu item. The service processor’s IP address is displayed using the following format: Current IP address in BMC: xxx.xxx.xxx.xxx 2. Using a client system, establish a Secure Shell (SSH) connection to the service processor’s IP address. ssh -l root sp_ip_address 3. Log in to the service processor as an Administrator, for example: login: root password: changeme 4. Start the ILOM console mode by entering the following: start /SP/console You can configure the SP serial port to display the installation process to a VGA connection (video port). See “Selecting Your Console Output” on page 35. 5. If you have changed the SP Serial Port default settings, make sure you reset them to the default settings. 6. Follow the Solaris 10 on-screen prompts. Use the information gathered in “Installation Worksheet” on page 32 to help you enter the system and network information as you are prompted. Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 37 The screens that are displayed will vary, depending on the method that you chose for assigning network information to the server (DHCP or static IP address). After you have entered the system-configuration information, the server completes the boot process and displays the Solaris login prompt. ▼ To Connect to the Server Using a Terminal Program 1. Use a cable to connect the serial port of the server to the serial port of the host system. 2. Make sure the communication properties of the serial port of the system are set to the default. The default settings are 9600 baud, 8N1 (eight data bits, no parity, one stop bit), disable flow control. 3. Start a terminal session to capture the serial port output: On a client running Solaris OS, type: $tip -9600 /dev/ttya On a client running Windows, start a program such as Hyperterminal. On a client running Linux, start a program such as Minicom, a text-based serial communication program that is included in the Linux distributions. For more information, see the man pages included in the Linux distribution. 4. Log in to the service processor as an Administrator, for example: login: root password: changeme 5. Start the ILOM SP GUI by entering the following: start /SP/console 6. Power on main power to the server by using a nonmetalic stylus to press the recessed Power button on the front panel. POST messages appear on your screen as the OS boots up. 7. Follow the Solaris 10 preinstallation on-screen prompts. Use the information gathered in “Installation Worksheet” on page 32 to help you enter the system and network information as you are prompted. The screens that are displayed will vary, depending on the method that you chose for assigning network information to the server (DHCP or static IP address). 38 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 After you have entered the system-configuration information, the server completes the boot process and displays the Solaris login prompt. Solaris 10 User Documentation You can access the various collections of the Solaris 10 OS user documentation at: http://docs.sun.com/app/docs/prod/solaris.10 Specifically, you can access the Solaris 10 OS Release and Installation Collection at: http://docs.sun.com/app/docs/coll/1236.1 Downloading Solaris 10 OS Software If you need to re-install the Solaris 10 OS after removing it, you can download the CD or DVD image. ■ To download the CD image, see: http://javashoplm.sun.com/ECom/docs/Welcome.jsp?StoreId= 8&PartDetailId=Sol10-hw1-x86-G-F&TransactionId=try ■ To download the DVD image, see: http://javashoplm.sun.com/ECom/docs/Welcome.jsp?StoreId= 8&PartDetailId=Sol10-hw1-x86-DVD-G-F&TransactionId=try Solaris 10 OS Training Sun provides flexible training options that accommodate your personal schedule and learning style. The training options include instructor-led, web-based online, CDROM and Live Virtual Class. For Solaris 10 Training and Certification options at a glance, please visit: http://www.sun.com/training/catalog/solaris10.html Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 39 40 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Index B H back panel cable connectors 13 back panel illustration 13 headless operation 14 C ILOM client-side secure shell 20 configuring with Ethernet 23 configuring with serial 21 configuring with static Ethernet 26 introduction 19 remote console application 20 service processor firmware 20 service processor hardware 20 software components 20 installation overview 1 installing to a rack 2 Integrated Lights Out Manager, see ILOM Intel NIC 14 cable management assembly 7 cables 13 Cisco 72-3383-01 console cable 15 client-side secure shell 20 CMA assembly 7 connectors, back panel 13 D default serial port speed 15 driver updates vi E emergency shutdown 18 Ethernet connection to service processor 23 Ethernet ports 14 I M main power, applying 17 F N firmware updates vi flow control 15 NET connectors 14 Nvidia CK8-04 NIC 14 G O Gigabit Ethernet ports 14 graceful shutdown 17 OS installation, references 29 overview of installation 1 41 P power powering off 17 powering on main power 17 powering on standby power 16 product updates vi R rack installation 2 remote console application 20 RJ45 port 15 S screen resolution 14 serial connection to service processor 21 service processor configuring with Ethernet 23 configuring with serial 21 firmware 20 hardware 20 shutting down power 17 slide-rail installation 3 standby power, applying 16 static Ethernet configuration 26 Sun RJ45-to-DB9 adapter 15 V video monitor cable 14 video redirection 14 42 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Mode : UseOutlines XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Keywords : Lang="en".PartNumber="819-1155-16".ReleaseDate="May 2007" Creator Tool : FrameMaker 7.1 Modify Date : 2007:05:17 23:30:42Z Create Date : 2007:05:17 23:30:42Z Format : application/pdf Title : Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide Creator : Sun Microsystems Description : This Installation Guide contains procedures for installing the server in a rack, cabling, and powering on the server. It also contains procedures for connecting to the service processor administrator account. Links to documentation for configuring the preinstalled Solaris 10 software or for installing other supported operating systems are also included. Document ID : uuid:e092e6f4-66e1-4064-8ea3-d1a6e3f265fc Instance ID : uuid:aa545e2f-38b9-45b6-8749-7182a062cbc3 Page Count : 50 Subject : This Installation Guide contains procedures for installing the server in a rack, cabling, and powering on the server. It also contains procedures for connecting to the service processor administrator account. Links to documentation for configuring the \.preinstalled Solaris 10 software or for installing other supported operating systems are also included. Author : Sun MicrosystemsEXIF Metadata provided by EXIF.tools