SunPower 513402 SunPower Monitoring System with PVS5x User Manual
SunPower Corporation SunPower Monitoring System with PVS5x
SunPower >
User Manual
Kit Contents PV Supervisor 5x (PVS5x) Bracket Connection Diagram Power Line Ethernet Adapter and Cable See other side for detailed installation instructions. Warning! Do not power up the solar system until after you complete Steps 1 through 3. Important! Do not run communication cables through same opening or conduit as power wire. 1. Mount the PVS5x Select location, mount bracket and secure with appropriate hardware, and it PVS5x onto bracket. AC Module Connection Current Transformers (CTs) Consumption CTs (Optional) Production CT on io aio ai ica ic nic un mun m mm om ro Er om Co r rter ice C ular rnet w nve ev ell nte Refer to the AC Module System Design and Intall Guide for installation instructions. DC Inverter Communication Refer to the PVS5x Devices Guide for installation and wiring instructions. Connect the cable with the blue connector cable from the RS-485 2-WIRE port to the irst inverter. 2-Wire RS-485 Connections Service Panel Communication Cables Inverters (blue connector) Label AC Module Sub-Panel D+ D- GND B b BR D+ D– GND SMA TB ABB TB External Meter (green connector) SMA/ABB/METER/ OTHER (2-W) D-AUX RS-485 2-Wire FRONIUS (4-W)/ METER/OTHER INSTALLER COMPUTER HOMEOWNER ROUTER RS-485 2/4-Wire LAN1 WAN/ LAN2 External Meter Communication Refer to the PVS5x Devices Guide for installation and wiring instructions. Connect the cable with the green connector cable from the RS-485 2/4-WIRE port to the meter communication terminals. Hardware (2) M4 x 12 mm screws (2) 3/4” sealing washers (2) hole plugs (4) 3/4” to 1/2” reducing washers You Will Need • • • • • • • • • Phillips screwdriver Small lathead screwdriver RJ45 crimp tool Wire cutter Wire stripper Laptop with IE, Chrome, or Firefox installed Ethernet cable Your SunPower monitoring website credentials (Optional) Customer’s Wi-Fi network and password Internet Connection 2. Wire the PVS5x Power Remove PVS5x covers (external enclosure, internal AC wiring top and bottom), place partition, run power conduit, run 240 VAC and land in terminals, run CT wires and land in J16, replace AC wiring covers. 240 VAC Routing Wire and Cable • Any openings in the enclosure must be illed with Type 4 or better rated components to maintain the integrity of the enclosure’s environmental system • Drill extra openings with appropriate knockout tools (do not use screwdriver and hammer) • Only use the provided conduit openings or knockout locations and never cut holes in the top or sides of the enclosure • Never run communications cable and AC wiring in same conduit Connect Ethernet cable from router to WAN port, or connect cable from Power Line Ethernet Adapter to router (with supplied yellow in-home Ethernet Adapter cable), or connect to homeowner’s Wi-Fi. GND L1 CT Wiring L2 B W B W B W CONS L1 CONS L2 PROD 4. Use the PVS Management App to Commission Turn laptop Wi-Fi of , connect Ethernet cable from laptop to PVS5x LAN1 (black) port, open a browser and type: 3. Connect Communicaton • Run communication conduit • Install Ethernet cable, or Power Line Ethernet Adapter, or connect to homeowner’s Wi-Fi • Connect inverter communication to PVS5x (AC Modules already connected through service panel) • Connect cable from meter to open RS-485 port • Replace the enclosure cover D-AUX RJ-45 Plug www.sunpowerconsole.com Follow the instructions to setup communication, check irmware, discover devices, verify device operation, and commission the site. o 0 g B b G br BR T-568B PVS5x (all ports) Clip is pointed away from you RS-485 2-Wire RS-485 2/4-Wire LAN1 WAN/ LAN2 SMA/ABB/METER/ OTHER (2-W) FRONIUS (4-W)/ METER/OTHER INSTALLER COMPUTER HOMEOWNER ROUTER Detailed Installation Instructions 1. Mount the PVS5x 3. Connect Communications to PVS5x 1. Select an installation location that is not in direct sunlight. 2. Mount PVS5x bracket using appropriate hardware for the surface type that supports 6.8 kg (15 lbs). 3. Fit PVS5x onto bracket until the pins fully engage the PVS5x holes. 4. Secure PVS5x to bracket using the two included M4 x 12 mm screws. 2. Wire the PVS5x Power Warning! Do not power up the system until after you complete Step 2 and Step 3 and are ready to conigure the PVS5x. 1. Ensure that the circuit breaker is OFF. 2. Prepare the PVS5x for AC wiring: • Remove the PVS5x enclosure cover by loosening three screws on the bottom of the enclosure. • Remove the top AC wiring cover. • Remove the bottom AC wiring cover. • Flip the AC wiring partition to the opposite side of where your AC wiring will be incoming. ENCLOSURE COVER AC WIRING COVERS TOP AC WIRING PARTITION BOTTOM SunPower recommends connecting PVS5x directly to the customer’s router with an Ethernet cable. 1. Run communication conduit to the PVS5x conduit opening. The PVS5x is preconigured with 3/4” conduit openings. You can use 1/2” conduit with supplied reducing washers and gaskets. Seal all unused holes with the included Type 4 hole plugs. Important! Do not run communication cables through same opening or conduit as power wire. 2. Connect to homeowner’s Internet using Ethernet cable, Power Line Ethernet Adapter, or their Wi-Fi network. 3. To connect communication for each device. Follow the Quick Start Guide: SunPower Monitoring System PVS5x Devices for complete instructions. • AC modules: You should have already connected AC modules to the service panel. The PVS5x communicates with AC modules D-AUX WAN/ LAN1 RS-485 RS-485 LAN2 2/4-Wire 2-Wire using PLC protocol. INSTALLER HOMEOWNER SMA/ABB/METER/ FRONIUS (4-W)/ COMPUTER ROUTER METER/OTHER OTHER (2-W) • SMA, ABB: Connect the cable with a blue connector from the PVS5x RS-485 2-WIRE communications port (blue) and land wires in the only, or irst, inverter in the daisy-chain. • Meter: Connect the cable with a green connector from the PVS5x RS-485 2/4-WIRE port (green) to the (optional) external meter communication terminals. 4. Replace the PVS5x enclosure cover and tighten three srews on bottom of enclosure. 4. Use the PVS Management App to Commission 1. 2. 3. 4. Turn laptop Wi-Fi of. Connect an Ethernet cable from laptop to PVS5x LAN1 port. Open a browser and type: www.sunpowerconsole.com. Follow the instructions to set up communication, check irmware, discover devices, verify device operation, and commission the site. Safety & Certiications Safety Instructions 3. Run power conduit from the service panel to the PVS5x. Note. The PVS5x is preconigured with openings for 3/4” conduit. You can use 1/2” conduit with supplied reducing washers and gaskets. If you use the rear conduit entrances, seal the holes on the bottom of the enclosure with the included hole plugs. 4. For electrical wiring code compliance and optimal communications, connect the PVS5x to a dedicated UL listed 15 A rated dual-pole breaker using 14AWG wiring, or a UL listed 20 A rated dual-pole breaker using 12AWG wiring. When using AC modules, this breaker should be in the same service panel containing the 20 A dual-pole breakers for the modules. 5. Strip wires and land the black wire to L1, the red wire to L2, the white wire to N, and the green wire to GND in the PVS5x terminals. 6. Run CT wires for consumption monitoring from the service panel, through the power conduit, and land one set of CT wires in CONS L1 and the second set in CONS L2. Verify that the CT phases are consistent with the AC wiring phases. 7. (Optional) If installing production monitoring with solid core production CT: run CT wires from the service panel, through the power conduit, and land this set of CT wires in PROD. 8. Replace the bottom AC wiring cover. 9. Replace the top AC wiring cover over the AC power wires (on the left if you ran through left hole, on the right if you ran through the right hole). GND L1 L2 B W B W B W CONS L1 CONS L2 PROD Installation and ield service is to be performed only by qualiied, trained personnel with the necessary skills and knowledge to work on this type of electrical device. Field service is limited to the components contained in the lower compartment of the PVS5x. • Perform all electrical installations in accordance with any national and local codes, such as the National Electrical Code (NEC) ANSI/NFPA 70. • This enclosure is suitable for use indoors or outdoors (Type 3R). Operating ambient from -30°C to 60°C. • Before connecting power, the PPVS5x must be securely mounted to an inside or outside wall following the instructions in this document. • For permanently connected equipment, a readily accessible disconnect device must be incorporated external to the PVS5x. • For electrical wiring code compliance, connect the PVS5x to a dedicated UL listed 15 A rated breaker using 14AWG wiring, or a UL listed 20 A rated breaker using 12AWG wiring. The input operating current is less than 0.1 amp with AC nominal voltages of 240 VAC (L1-L2). • The PVS5x contains internal transient surge protection for connection to the load side of the service entrance AC service panel (overvoltage category III). For installations in areas at risk of surges generated by high voltage utilities, industry or by lightning, it is recommended that an external surge protective device also be installed. • Do not attempt to repair the PVS5x. If the PVS5x fails, please return the unit to your distributor for servicing. Tampering with or opening the upper compartment voids the product warranty. • For pluggable devices, the socket-outlet must be installed near the equipment and must be easily accessible. FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment of and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit diferent from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. IMPORTANT NOTES: Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 25 cm between the radiator and your body. Quick Start Guide: SunPower Monitoring System with PVS5x Follow these instructions to install, conigure, and commission the PVS Supervisor 5x (PVS5x) to start receiving monitoring data. See the safety and installation manual for complete instructions. Caution Changes or modiications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device and it’s antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. Safety Certiication • UL listed to UL60950-1 ITE and UL60950-22 for outdoor use. • The PVS5x is not a utility meter, disconnect device, or power distribution device. Quick Start Guide: SMS PVS5x 513403 Rev C Copyright 2015 SunPower Corporation
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Create Date : 2015:08:24 09:58:08-05:00 Creator : Adobe InDesign CC 2015 (Windows) Modify Date : 2015:08:25 09:48:56+08:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2015:08:25 09:48:56+08:00 Creator Tool : Adobe InDesign CC 2015 (Windows) Instance ID : uuid:fa0e714a-4769-4281-a1ed-09d7776b3948 Original Document ID : xmp.did:d2461f14-cf1d-5b4d-94e6-8f527790580f Document ID : xmp.id:6bde2fdb-0024-1a4a-a37b-e2a69d954fbe Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:79bac254-3dd5-014f-a514-3745096ac332 Derived From Document ID : xmp.did:959fdaa7-8b4b-a44e-b28a-ebfbd877aead Derived From Original Document ID: xmp.did:d2461f14-cf1d-5b4d-94e6-8f527790580f Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Windows) History Changed : / History When : 2015:08:24 09:58:08-05:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 2EXIF Metadata provided by EXIF.tools