Super Electronic Technology SPK300 Tag User Manual SP K300

Shanghai Super Electronic Technology Co., Ltd Tag SP K300

User Manual

SUPER-RFID                             11/28/2006  Shanghai Super Electronic Technology Co. Ltd         Phone: 021-64646641, 64646643, 64692252  Fax: 021-64646643-802 E-Mail: marketing@superrfid.net      website:http://www.superrfid.net               Page 1 of 5                SUPER-RFID  SP-K300 series long range RF Tag   User manual
SUPER-RFID                             11/28/2006  Shanghai Super Electronic Technology Co. Ltd         Phone: 021-64646641, 64646643, 64692252  Fax: 021-64646643-802 E-Mail: marketing@superrfid.net      website:http://www.superrfid.net               Page 2 of 5  As a unique identifier for objects being attached to, SP-K300 tags can communicate with reader bi-directionally at 2.45GHz microwave frequency band.   Product performance:  z Long range automatic identification (2-80m adjustable) z Anti collision capability, simultaneously identification up to 200 z High speed Multi channel identification capability z Globally free ISM 2.45GHZ microwave frequency band z Ultra low RF transmission power consumption, healthier and safer z Unique power saving mode design with long work life from 6 to 8 years z Time division multi address technology based on HDLC and synchronized communication mechanism  z Provide simple and clear instructions and memory area for customers z Provide standard 1K bytes storage space and can be divided into some sectors z Anti-jamming capability, tolerance of interfering sources at the scene z Solid state encapsulation, tolerance of high strength dropping and vibration, preventive of disassembling  z Meet harsh industrial environment requirements
SUPER-RFID                             11/28/2006  Shanghai Super Electronic Technology Co. Ltd         Phone: 021-64646641, 64646643, 64692252  Fax: 021-64646643-802 E-Mail: marketing@superrfid.net      website:http://www.superrfid.net               Page 3 of 5  product specifications  Mechanical characteristics:  parameters  specifications  Tag type   Read/Write Size   86mm*54mm*5mm Weight  30g  Shell material   High temperature modified alloy plastics Color   Black,white etc. Installation place Object Surface Installation manner 3M two-sided glue or other sticking methods, or using screw to fix  Microwave link characteristics:   specifications  parameters   Uplink  Downlink Modulation  GFSK   GFSK  Communication data rate 1000kbit/s  1000kbit/sFrequency  2.4 - 2.4835 GHz  Working voltage  2.2V-3.3V Max  output power 0dbm  Wakeup time  Less than 3uS Antenna polarization  Vertical polarization Receiving sensibility –80dBm--90Bm  Bit error rate  10-7  Electric characteristics:
SUPER-RFID                             11/28/2006  Shanghai Super Electronic Technology Co. Ltd         Phone: 021-64646641, 64646643, 64692252  Fax: 021-64646643-802 E-Mail: marketing@superrfid.net      website:http://www.superrfid.net               Page 4 of 5  Parameters   Specifications Power consumption  < 2µA (quiescent current)  <3.5mA (work current)  Work life 3.0V/750mAh lithium cell(6-8 years) Can choose cell with ten-years work life      Environment characteristics:  Parameters   Specifications Temperature  -40℃ ~ +80℃  Storage temperature -60℃ ~ +85℃  Vibration    10~2000Hz 15g three axes Free dropping   1500mm  concrete  floor ,twice on each side  Anti electromagnetism 10V/m  0.1 ~ 1000MHz  AMelectromagnetic waves
SUPER-RFID                             11/28/2006  Shanghai Super Electronic Technology Co. Ltd         Phone: 021-64646641, 64646643, 64692252  Fax: 021-64646643-802 E-Mail: marketing@superrfid.net      website:http://www.superrfid.net               Page 5 of 5   Warning:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. The equipment compliance with FCC radiation exposure limit set forth for uncontrolled environment  Changes or modifications to this unit not expressly approved by the party responsible for compliance will void the user’s authority to operate the equipment. Any change to the equipment will void FCC grant.

Navigation menu