Super Nova Co TR01 Transmitter of car alarm system User Manual

Super Nova Co Ltd Transmitter of car alarm system

Users Manual

Download: Super Nova Co TR01 Transmitter of car alarm system User Manual
Mirror Download [FCC.gov]Super Nova Co TR01 Transmitter of car alarm system User Manual
Document ID887607
Application IDF50c3suO2RunIWGJccHW6Q==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize16.76kB (209543 bits)
Date Submitted2008-01-10 00:00:00
Date Available2008-01-10 00:00:00
Creation Date2007-12-26 13:59:24
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2007-12-26 13:59:24
Document TitleMicrosoft Word - User manual.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: eva_kao

961019
EASY‐GO TX303 AND EG30‐H
HANDS‐FREE ENTRY SYSTEM
WITH DYNAMIC IMMOBILIZER & SMART ANTI‐HIJACK
SYSTEM FEATURES:
1. AUTO‐UNLOCK
The system UNLOCKS the vehicle when the user is approximately 2 meters away and trigger waves are sent to the
transponder to confirm user’s presence. 2 seconds after the system is UNLOCKED, the vehicle enters Immobilizer Mode.
2. DYNAMIC IMMOBILIZER
The Immobilizer function will be automatically disabled when the system performs Hand‐Shake confirmation with the
transponder upon inserting the key and turning ON the ignition.
The vehicle CANNOT be started with just the key as the
transponder must be present as well when attempting to start the vehicle.
*The vehicle CANNOT be started unless all
doors are closed, to change this setting, please refer to the Miscellaneous Settings & Wiring Diagram section below.
3. SMART ANTI‐HIJACK
When Anti‐Hijack Mode is set to ON, if any doors are opened and closed anytime after Ignition ON, the system will check‐in
with the transponder after 2 minutes. If the transponder is not present after 60 consecutive checks (approx. 40 seconds),
the system enters Anti‐Hijack Mode, activating Starter Disable or Petroleum Pump Disable depending which is installed.
* The use of Starter Disable or Petroleum Pump Disable is recommended instead of Engine Block Disable
4. PASSIVE LOCK
While in Immobilizer Mode, whenever the vehicle doors are opened and closed, the system will check with the transponder
every 15 seconds and LOCKS the vehicle when it is not in range. * If the user is going to work/stay around the vehicle for
an extended amount of time, it is recommended to turn off all Easy‐Go features temporarily in order to avoid unnecessary
drain of transponder battery (see below)
Rev. 7.00 - Last Updated: 10/08/2007
5. AUTOMATIC RE‐LOCK
The system will Re‐LOCK the vehicle if 1 of 2 conditions applies: 1) The user enters and leave the Detection Zone without
opening the doors; 2) The user opens and closes the doors without turning on the ignition and leave.
HOW TO TEMPORARILY DISABLE EASY‐GO FEATURES:
At any given time, the user may perform the below operations to disable/resume all Easy‐Go functions:
* Press the transponder button ONCE and within 3 seconds, press the transponder button AGAIN (Car Lamp flashes ONCE):
‐ Vehicle Locks/Unlocks; All Easy‐Go functions are temporarily disabled (until the next Ignition ON)
* Press the transponder button ONCE ONLY (without pressing again within 3 seconds):
‐ Vehicle Locks/Unlocks; All Easy‐Go functions are resumed or will continue to function if not previously disabled.
SMART TRANSPONDER LOW‐BATTERY WARNING:
If the transponder battery is low, the vehicle will turn off all Easy‐Go functions and warn the user by the following actions:
Upon System UNLOCK: Car Lamp FLASHES 5 times and horn HONK 5 times
Upon System LOCK: Car Lamp FLASHES 5 times and horn HONKS 3 times.
At this time, all receiving functions on the transponder will be turned OFF to allow the user enough time to change the battery.
After the
battery is replaced, simply press the transponder button once to LOCK/UNLOCK the vehicle and all Easy‐Go functions will be restored.
Rev. 7.00 - Last Updated: 10/08/2007
SYSTEM LEARNING & CONFIGURATION:
TRANSPONDER LEARNING:
1.
Insert the key and turn to IGNITION.
2.
Press and Hold Override Switch for 5 seconds, LED stays solid ON indicating Learning Mode.
3.
Press the transponder button.
4.
LED flashes ONCE indicating transponder learned, LED then stays on solid.
5.
Repeat Step 3 until all transponders are learned by the system (Maximum of 4 transponders can be learned).
6.
The system exits Learning Mode after 10 seconds, to exit at any time, turn the IGNITION to OFF.
LED INDICATOR SETTING:
1. Take the battery out and put it back in.
2. With in 10 seconds, Press and Hold the transponder button for 3 seconds.
3. The transponder LED will now flash when communicating with the vehicle.
TRANSPONDER RANGE ADJUSTMENT: *This adjustment can be done at anytime OR after the 10‐second period upon replacing the battery.
1. Press and hold the transponder button for 3 seconds.
2. The transponder LED flashes in the order of: ONCE (long), TWICE (medium), and THREE (short) times.
3. Release the transponder button AFTER your desired range is FLASHED.
(i.e. Releasing the button after the
LED flashes THREE times sets the range to SHORT)
USER PROGRAMMABLE FUNCTIONS:
1.
Insert the key and turn to IGNITION.
2.
Press Override Switch 5 times, car lamp flashes 5 times, car horn honks 5 times, LED stays solid ON, indicating
Factory Settings Mode.
3.
Press Override Switch ONCE to enter Dome Light Delay Setting (Car Horn honk ONCE) then press the
transponder button to TOGGLE the feature ON/OFF.
The LED flashes ONCE to indicate ON and flashes
TWICE to indicate OFF.
4.
Refer to the Programming Table below for the number of Override Switch PRESS for each setting.
PROGRAMMING TABLE: (√ indicates Factory Default settings for each feature)
Override Switch
Chirp
Press Transponder Button to Toggle the Functions ON/OFF
Press Once
Dome Light Delay
√
Disable
Press Twice
Anti‐HiJack Mode
√
Disable
Press 3 Times
√
Complete Easy‐Go Functions
Disable
Press 4 Times
√
Central Door Lock Trigger (0.6 sec.)
Central Door Lock Trigger (3 sec.)
Press 5 Times
√
1 Chirp after Arming
No Chirp after Arming
Press 6 Times
√
5 Sec. Automatic Door Lock on Ignition
Disable
Press 7 Times
√
Door Unlock on Ignition OFF
Disable
Press 8 Times
√
Car Horn
Alarm Siren
Press 9 Times
√
Chirp Duration 30ms
Chirp Duration 50ms
Press 10 Times
10
√
Transponder Check every 6 seconds
Transponder Check every 1 seconds
Press 11 Times
11
Press the transponder button ONCE again to confirm reset all settings to Factory Default
Rev. 7.00 - Last Updated: 10/08/2007
EXTERNAL TRANSMITTER
NOTE ON IGNITION KILLER / PETROLEUM PUMP DISABLE (YELLOW WIRE):
A separate Relay is required to connect the Ignition Killer /
Petroleum Pump Disable (not included in the package).
SHOCK SENSOR (OPTIONAL)
3 P RED 3 PWHITE
N/C
BLUE
GREEN
PURPLE/WHITE
6 WHITE
COM
UNLOCK
COM
LOCK
N/O
N/C
GARY
WHITE
N/O
PURPLE
EXTERNAL TRANSMITTER
3 P RED
2 P WHITE 2 P WHITE 7 P WHITE
RED
GREEN/WHITE
BLUE
BLACK
YELLOW
BROWN/WHITE
WHITE
DOOR(+)
DOOR(-)
(+)12V VDC
PARKING LIGHTOUTPUT(10mA)
IGNTION
(-)GROUND
IGNITION KILLER\PETROLEUM PUMP DISABLE OUTPUT(-)
DOOR(±)DOOR SENSOR INPUT
CAR HORN
SERLECTION JUMPERS
OVERRIDE SWITCH
LED
Rev. 7.00 - Last Updated: 10/08/2007
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
FCC STATEMENT
THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS B DIGITAL DEVICE,
PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE
PROTECTION AGAINST HARMFUL INTERFERENCE IN A RESIDENTIAL INSTALLATION. THIS EQUIPMENT GENERATES,
USES AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTALLED AND USED IN ACCORDANCE WITH
THE INSTRUCTIONS, MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS
ANY CHANGES OR MODIFICATION NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE COULD VOID THE
USER'S AUTHORITY TO OPERATE THE DEVICE.
Rev. 7.00 - Last Updated: 10/08/2007

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2007:12:26 13:59:24+08:00
Create Date                     : 2007:12:26 13:59:24+08:00
Format                          : application/pdf
Title                           : Microsoft Word - User manual.doc
Creator                         : eva_kao
Document ID                     : uuid:75fb1a7a-0024-454b-89fa-2476f3f2c635
Instance ID                     : uuid:c018c8a7-c4ed-4f2c-8d76-bd1a11faf6be
Page Count                      : 5
Author                          : eva_kao
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M65TR01

Navigation menu