Suprema BEPMOC FINGRPRINT SYSTEM User Manual 2 of 2

Suprema Inc. FINGRPRINT SYSTEM 2 of 2

Contents

User manual 2 of 2

Download: Suprema BEPMOC FINGRPRINT SYSTEM User Manual 2 of 2
Mirror Download [FCC.gov]Suprema BEPMOC FINGRPRINT SYSTEM User Manual 2 of 2
Document ID954895
Application IDR/hU9mr+QJGeNYfKUGvBNg==
Document DescriptionUser manual 2 of 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize229.47kB (2868327 bits)
Date Submitted2008-06-12 00:00:00
Date Available2008-06-12 00:00:00
Creation Date2008-05-28 17:49:07
Producing SoftwarepdfFactory Pro 3.17 (Windows XP Professional Korean)
Document Lastmod2008-05-28 17:49:13
Document TitleBEPlus_InstallationGuide_V1.0_English_Certification.ppt
Document CreatorpdfFactory Pro www.pdffactory.com
Document Author: mclee

Bottom and Back Side
Bottom
Star-shaped screw hole for fixing a body to a metal bracket
Back
3 pin connector – wiegand output
5 pin connector – power and RS485
4 pin connector – ethernet (TCP/IP)
7 pin connector – digital input and relay output
DIP switch – RS485 termination setting
(Refer to “RS485 Connection” pages for details)
11
ⒸCopyright 2007 Suprema Inc.
Product Dimension
50
160
160
Front
40
37
150
Side
135
Metal Bracket
(unit : mm)
12
ⒸCopyright 2007 Suprema Inc.
Cables and Connectors
Power and RS485
TCP/IP
PIN
PIN DESCRIPTION
POWER +12V
POWER GND
RS -485 GND
RS -485 TRX+
RS -485 TRX-
WIRE
RED
BLACK
GRAY
BLUE
YELLOW
PIN
PIN DESCRIPTION
WIRE
RJ45 PIN
TX +
TX RX +
RX -
YELLOW
GREEN
RED
BLACK
Wiegand output
PIN
PIN DESCRIPTION
WIEGAND DATA0
WIEGAND DATA1
WIEGAND GND
WIRE
GREEN
WHITE
BLACK
PIN
PIN DESCRIPTION
SW1 INPUT
SW1 GND
SW2 INPUT
SW2 GND
RELAY NORMAL CLOSE
RELAY COMMON
RELAY NORMAL OPEN
WIRE
YELLOW
BLACK
GREEN
BLACK
ORANGE
BLUE
WHITE
Digital Inputs and Relay output
13
ⒸCopyright 2007 Suprema Inc.
Installation of Wall-mount Bracket
Fix wall mount bracket on a wall using wall mounting
screws
Hook BioEntry Plus on the wall mount bracket
Wall mounting
screws
Fix BioStation and wall mounting bracket using a star
shape screw.
Star-shaped
screw
Star-shaped
wrench
14
ⒸCopyright 2007 Suprema Inc.
Power Connection
Recommended power supply
l 12V
± 10%, at least 1500mA.
l Comply with standard IEC/EN 60950-1.
l To share the power with other devices, use a power supply with higher current ratings.
15
ⒸCopyright 2007 Suprema Inc.
Ethernet Connection
16
ⒸCopyright 2007 Suprema Inc.
Ethernet Connection (Direct connection with PC)
To connect BioEntry Plus with a PC directly, connect both devices with a straight CAT-5
cable. As the BioEntry Plus supports auto MDI/MDIX feature, it is not necessary to use a
crossover type cable.
17
ⒸCopyright 2007 Suprema Inc.
RS485 Connection for Host Communication
18
ⒸCopyright 2007 Suprema Inc.
RS485 Connection for Secure I/O
Max number of devices
l Maximum
numbers of devices in an RS485 loop are two(2) devices (BioStation or BioEntry
Plus) and four(4) Secure I/Os
19
ⒸCopyright 2007 Suprema Inc.
Relay Connection – Fail safe lock
20
ⒸCopyright 2007 Suprema Inc.
Relay Connection – Fail secure lock
21
ⒸCopyright 2007 Suprema Inc.
Relay Connection - Automatic door
22
ⒸCopyright 2007 Suprema Inc.
Digital Input Connection (RTE, Door sensor)
23
ⒸCopyright 2007 Suprema Inc.
Digital Input Connection (Alarm, Emergency sw)
24
ⒸCopyright 2007 Suprema Inc.
Wiegand Output
25
ⒸCopyright 2007 Suprema Inc.
Installation Reference 1 - Stand alone
Door Sensor
Door Lock
Exit Button
BioEntry Plus
LAN
PC
Enroll Scanner
26
ⒸCopyright 2007 Suprema Inc.
Installation Reference 2 – Secure
RS485
Door Sensor
Door Lock
Exit Button
Secure I/O
BioEntry Plus
LAN
PC
Enroll Scanner
27
ⒸCopyright 2007 Suprema Inc.
Installation Reference 3 – Network
Door Zone 1 (Anti passback)
RS485
BioStation
RS485
BioEntry Plus
BioEntry Plus
Secure I/O
LAN
PC Server Enroll Scanner
PC Client
BioStation
Secure I/O
BioEntry Plus
Exit Button
RS485
Door Zone 2 (Anti passback)
PC Client
28
ⒸCopyright 2007 Suprema Inc.
Electrical Specification
Min.
Typ.
Max.
Notes
10.8
12
13.2
Use regulated DC power adaptor only
Power
Voltage (V)
Current (mA)
250
Switch Input
VIH (V)
TBD
VIL (V)
TBD
Pull-up resistance (Ω)
4.7k
VOH (V)
VOL (V)
0.8
Pull-up resistance (Ω)
4.7k
Switching capacity (A)
0.3
Switching power
(resistive)
30W
37.5VA
DC
AC
Switching voltage (V)
110
125
DC
AC
The input ports are pulled up with 4.7k resistors
TTL/Wiegand Output
The outputs ports are open drain type, pulled up with 4.7k resistors
internally
Relay
30V DC
125V AC
29
ⒸCopyright 2007 Suprema Inc.
Troubleshooting
Fingerprint can not be read well or it takes too long.
Fingerprint is entered but authorization keeps failing.
Check whether the user is restricted by door zone or time zone.
Inquire of administrator whether the enrolled fingerprint has been deleted frin the device for some
reason.
Authorized but door is not opened.
Check whether a finger or fingerprint sensor is stained with sweat, water, or dust
Retry after wiping off finger and fingerprint sensor with dry towel.
If a fingerprint is way too dry, blow on the finger and retry.
Check whether the time is set as lock time.
Check whether an antipass back mode is in use. In antipass back mode, only who entered can exit.
Device doesn’t operate though power is connected.
Check whether a device and a bracket is well connected to each other. If not, a tamper switch is
activated and the device doesn’t work.
30
ⒸCopyright 2007 Suprema Inc.
Device cleaning
Wipe out machine surface with dry towel or cloth.
In case there is dust or impurities on the sensor of the BioStation, wipe off the surface with
dry towel.
Note that if the sensor is cleaned by detergent, benzene or thinner, surface is damaged and
fingerprint can’t be entered.
31
ⒸCopyright 2007 Suprema Inc.
FCC Rules
Caution
Warning
Information to User
Changes or modifications not expressly approved by the manufacturer
responsible for compliance could void the user's authority to operate the
equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limit of a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, user and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guaranteee that interference will not occur in a particular
installation; if this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
1.
2.
3.
4.
Reorient / Relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit difference from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help
32
ⒸCopyright 2007 Suprema Inc.
Suprema Inc.
16F Parkview Office Tower, Jeongja-dong, Bundang-gu,
Seongnam, Gyeonggi, 463-863 Korea
E-mail : support@supremainc.com
Website : www.supremainc.com
Functions and specifications of the product are subject to changes without notice due to quality
enhancement or function update. For any inquiry on the product, please contact Suprema Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 23
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:2ee26a1d-bd16-4a2a-a43e-7d6c0835f2ef
Modify Date                     : 2008:05:28 17:49:13+09:00
Create Date                     : 2008:05:28 17:49:07+09:00
Metadata Date                   : 2008:05:28 17:49:13+09:00
Document ID                     : uuid:5f99b3f5-6610-4880-996a-d90cea92cb68
Format                          : application/pdf
Title                           : BEPlus_InstallationGuide_V1.0_English_Certification.ppt
Creator                         : pdfFactory Pro www.pdffactory.com
Author                          : mclee
Producer                        : pdfFactory Pro 3.17 (Windows XP Professional Korean)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TKWBEPMOC