Suprema BIOENTRYOP Access Reader User Manual BioEntry Installation Guide 0 96c
Suprema Inc. Access Reader BioEntry Installation Guide 0 96c
Suprema >
Users Manual
BioEntry™ Installation Guide BioEntry™ Smart / Pass Ver. 0.96c Suprema Inc and BioEntry™ are registered trademarks of Suprema Inc. All rights reserved. No part of this work covered by the copyright hereon may be reproduced or copied in any form or by any means - graphics, electronic, or mechanical, including photocopying, recording, taping, or information and retrieval systems - without written permission of Suprema Inc. Any software furnished under a license may be used or copied only in accordance with the terms of such license. Suprema Inc reserves the right to modify or revise all or part of this document without notice and shall not be responsible for any loss, cost or damage, including consequential damage, caused by reliance on these materials. Copyright © 2005 by Suprema Inc. BioEntry Smart/Pass BioEntry Installation Guide 2 Suprema Warranty Policy Suprema warrants to buyer, subject to the limitations set forth below, that each product shall operate in substantial accordance with the published specifications for such product for a period of one (1) year from the date of shipment of the products (“Warranty Period”). If buyer notifies Suprema in writing within the Warranty Period of any defects covered by this warranty, Suprema shall, at its option, repair or replace the defective product which is returned to Suprema within Warranty Period, freight and insurance prepaid by buyer. Such repair or replacement shall be Suprema’s exclusive remedy for breach of warranty with respect to the Product. This limited warranty shall not extend to any product which has been: (i) subject to unusual physical or electrical stress, misuse, neglect, accident or abuse, or damaged by any other external causes; (ii) improperly repaired, altered or modified in any way unless such modification is approved in writing by the Supplier; (iii) improperly installed or used in violation of instructions furnished by Suprema. Suprema shall be notified in writing of defects in the RMA report supplied by Suprema not later than thirty days after such defects have appeared and at the latest one year after the date of shipment of the Products. The report should give full details of each defected product, model number, invoice number and serial number. No product without RMA (Return Material Authorization) number issued by Suprema may be accepted and all defects must be reproducible for warranty service. Except as expressly provided in the first paragraph, the products are delivered to Suprema without warranty of any kind, express or implied, including warranties or merchantability, fitness for a particular purpose. Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 3 Disclaimers Information in this document is provided in connection with Suprema products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Suprema’s Terms and Conditions of Sale for such products, Suprema assumes no liability whatsoever, and Suprema disclaims any express or implied warranty, relating to sale and/or use of Suprema products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Suprema products are not intended for use in medical, life saving, life sustaining applications, or other applications in which the failure of the Suprema product could create a situation where personal injury or death may occur. Should Buyer purchase or use Suprema products for any such unintended or unauthorized application, Buyer shall indemnify and hold Suprema and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Suprema was negligent regarding the design or manufacture of the part. Suprema reserves the right to make changes to specifications and product descriptions at any time without notice to improve reliability, function, or design. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Suprema reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. Please contact Suprema, local Suprema sales representatives or local distributors to obtain the latest specifications and before placing your Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 4 product order. Note: Third-party brands and names are the property of their respective owners. About the BioEntry™ Series BioEntry™ is an advanced biometric access reader equipped with award winning fingerprint recognition engine and standard wiegand interface. BioEntry™ can practically replace legacy and simple readers and be instantly added onto existing access control systems as well as new installations. BioEntry™ Smart is a fingerprint smart card reader that seamlessly integrates fingerprint and smart card reader into one device. BioEntry™ Smart is designed to replace existing access readers like proximity or magnetic readers without additional wiring. Fingerprint template is stored in each user’s smart card and there is no need to store fingerprint data in a reader itself. This eliminates the burden of template management and networking readers. BioEntry™ Pass is a fingerprint access reader equipped with fast one to many fingerprint identification engine. Enrolled with more than hundreds of users, identification can be done in less than one second. Following the unique feature of Suprema’s famous UniFinger™ fingerprint identification modules, BioEntry™ also provides customers with multiple choices of fingerprint sensors including optical, capacitive and thermal sensors. Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 5 About Suprema Inc Suprema is a leading biometric company offering core fingerprint technologies for embedded and PC applications. Suprema’s fingerprint products include low cost standalone OEM modules, access control readers, USB fingerprint scanners and fingerprint algorithm SDK. Suprema’s fingerprint recognition algorithm was proved to be world top level by ranking first in the 3rd international Fingerprint Verification Competition (FVC2004) with the lowest error rate in light category. Suprema’s fingerprint products have been sold to more than 50 different countries and are being used in various applications. For more information on Suprema’s technologies and products, Please visit Suprema’s website (http://www.supremainc.com) or contact by e-mail (sales@supremainc.com). About This Guide This is an introduction to the installation of BioEntry™ Smart and Pass. This guide describes how to install, examples for BioEntry™ and technical specifications. The purpose of this guide is to provide instructions on using BioEntry™ Smart and Pass and troubleshooting minor problems. Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 6 Contents 1. Before you start with BioEntry™ ............................................................................9 1.1. Included items......................................................................................................... 9 1.2. Required items........................................................................................................ 9 1.3. Optional items......................................................................................................... 9 2. Installing BioEntry™ .............................................................................................10 2.1. Connecting wires................................................................................................... 10 2.2. Power connection...................................................................................................11 2.3. Connecting to a Wiegand compatible reader............................................................11 2.4. Connecting to a Wiegand compatible access controller............................................ 12 2.5. Connecting to the host computer............................................................................ 12 2.5.1. Connecting via RS -232C interface..................................................................... 12 2.5.2. Connecting via RS -485 interface for a full duplex BioEntry network system ................ 12 2.5.3. Connecting via RS -485 interface for a half duplex BioEntry network system............... 13 2.5.4. Connecting via auxiliary interface...................................................................... 14 2.6. Disassembling....................................................................................................... 15 2.7. Mounting back plate.............................................................................................. 16 2.8. Reassembling the BioEntry.................................................................................... 16 2.9. Installing the BioEntry™ Admin Software.... 오류! 책갈피가 정의되어 있지 않습니다. 3. Examples for BioEntry™ installation....................................................................17 3.1. Building a new system ........................................................................................... 17 3.1.1. Installing BioEntry Pass................................................................................... 17 3.1.2. Installing BioEntry Smart ................................................................................. 17 3.2. Adding BioEntry to existing access control system................................................... 18 4. Specifications........................................................................................................20 4.1. Fingerprint Authentication Specifications ................................................................. 20 4.1.1. Fingerprint Authentication Performance.............................................................. 20 4.1.2. Fingerprint Sensor Specifications ...................................................................... 20 Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass 4.1.3. BioEntry Installation Guide 7 Data storage................................................................................................. 20 4.2. Mechanical Specifications...................................................................................... 20 4.2.1. Operating range ............................................................................................ 20 4.2.2. Absolute Maximum Ratings ....................... 오류! 책갈피가 정의되어 있지 않습니다. 4.2.3. Electrical DC characteristics ....................... 오류! 책갈피가 정의되어 있지 않습니다. Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 8 Figures Figure 1> A full duplex BioEntry network.............................................................13 Figure 2> A half duplex BioEntry network.............................................................14 Figure 3> Connecting stereo plug to DB-9 cable ... 오류! 책갈피가 정의되어 있지 않습니다. Figure 4> Auxiliary port................................. 오류! 책갈피가 정의되어 있지 않습니다. Figure 5> Aux. enable switch.......................... 오류! 책갈피가 정의되어 있지 않습니다. Figure 6> Removing the screw ........................................................................15 Figure 7> Separating the case.........................................................................15 Figure 8> Installing back plate to the wall.............................................................16 Figure 9> Reassembling the case.....................................................................16 Figure 10> BioEntry connection diagram .............................................................17 Figure 11> Adding BioEntry Pass to existing system................................................19 Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 9 1. Before you start with BioEntry™ 1.1. Included items l A BioEntry Smart/Pass unit l A stereo plug to DB-9 cable l This Installation Guide 1.2. Required items l A DC power supply rated at 12V @ 500mA l An access control panel with Wiegand input port 1.3. Optional items l A reader with Wiegand output port Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 2. Installing BioEntry™ 2.1. Connecting wires 10 The BioEntry is connected to other devices of the security system through the pigtail cable at the rear side. See Table 1 for wire colors and signals. Wire color Signal Description Shield (naked wire) EARTH Ground Earth GND Blue with yellow tracer Reserved Black with white tracer IN0 TTL IN 0 Black IN1 TTL IN 1 Brown with white tracer OUT0 TTL OUT 0 Brown OUT1 TTL OUT 1 Red with white tracer IO_GND GND, for IO signals Red Reserved Orange with white tracer WO_GND Wiegand Output, GND Orange WO_VREF Wiegand Output, VREF Yellow with red tracer WO_D0 Wiegand Output, Data 0 Yellow WO_D1 Wiegand Output, Data 1 Dark Green with white tracer WI_D0 Wiegand Input, Data 0 Dark Green WI_D1 Wiegand Input, Data 1 Blue with white tracer COM_GND Comm. GND (for RS-232C) Blue WI_GND Wiegand Input GND Violet with white tracer RX2 Receive data, RS-232C level Violet TX2 Transmit data, RS-232C level Gray with red tracer RX+ RX+, RS-485 level Gray RX- RX-, RS-485 level White with red tracer TX+ TX+, RS-485 level White TX- TX-, RS-485 level Green with yellow tracer POW_GND Power GND Red with yellow tracer POW+ Power Input Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 11 Table 1> BioEntry wire colors Warnings: Care should be taken identifying the wires. Improper wiring may render permanent damage to the device or personal injury. 2.2. Power connection Use ‘POW+’ and ‘POW_GND’ wires to connect BioEntry to a DC supply, rated at 9~24V, 500mA. The power cable should be as short as possible to minimize wire resistance and emissions. Additionally, for compliance regulations, a ferrite core should be installed to supply lines. The installation of this ferrite core is mandatory for R&TTE compliance. For optimum ESD resistance and safety, please make proper connection of ‘Earth GND’. Ferrite Core BioEntry Other signals Pigtail cable Ferrite Core POW+, POW_GND To power supply 3 turns Figure 1 Power connection 2.3. Connecting to a Wiegand compatible reader The BioEntry supports Wiegand compatible readers of various formats, including 26bit standard. Connect ‘WIN_D0’, ‘WIN_D1’ and ‘WIN_GND’ wires to ‘Data 0’, ‘Data 1’ signals and signal ground of the Wiegand reader, respectively. The input signals can tolerate voltages up to 12V dc. Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass 2.4. BioEntry Installation Guide 12 Connecting to a Wiegand compatible access controller The BioEntry supports a flexible Wiegand output interface for most access controllers with Wiegand input ports. Connect ‘WOUT_D0’, ‘WOUT_D1’ and ‘WOUT_GND’ wires to ‘Data 0’, ‘Data 1’ signals and signal ground of the access controller, respectively. If the access controller’s input signal level exceeds 5.0V, apply required voltage to ‘WOUT_VREF’ to obtain higher voltage output signals. Be cautious not to connect ‘WOUT_VREF’ directly to a voltage source, especially when the source is below 5Vdc. Use a diode and a current limit resistor of a few hundred ohms in series to prevent excessive currents and damages of the device. However, ‘WOUT_VREF’ signals can be safely left unconnected as most access controllers accept 5V Wiegand signals. 2.5. Connecting to the host computer The BioEntry provides various means to connect to the host computer such as: being a part of the RS-485 network, direct connection with RS-232C interface and an auxiliary port for laptops. 2.5.1. Connecting via RS-232C interface Connect ‘RX2’, ‘TX2’ and ‘COM_GND’ wires to ‘TX’, ‘RX’ and signal ground of PC’s serial port. 2.5.2. Connecting via RS-485 interface for a full duplex BioEntry network system Use ‘RX+’, ‘RX-’, ‘TX+’, and ‘TX-’ signals to join a full duplex BioEntry network. For a full duplex network, two pairs of twisted wires in a shielded cable is needed. Each signal in all BioEntry devices of the BioEntry network system should be connected forming a multipoint network. As the PC is the master of the network system, connect ‘TX+’ and ‘TX-’ signals of the computer to ‘RX+’ and ‘RX-’ of BioEntry signals, and vice versa(See Figure 2). At each end of the network, termination resistors of 120ohms should be connected between ‘+’ and ‘-’ signals for proper impedance matching. Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide BioEntry TX+ TXRX+ RX- BioEntry TX+ TXRX+ RX- BioEntry TX+ TXRX+ RX- RS-232 PC RX+ RXTX+ TX- Termination Resistors RS-485 Converter 13 Connect cable shield to earth GND at one point only Termination Resistors Figure 2> A full duplex BioEntry network Warnings: To prevent ground loops and avoid communication problems, connect cable shield to earth GND at only one point. 2.5.3. Connecting via RS-485 interface for a half duplex BioEntry network system For a half duplex network, a pair of twisted wires in a shielded cable is needed. For every devices in the half duplex network, tie ‘TX+’ with ‘RX+’ and ‘TX-’ with ‘RX-’ locally before connecting to the network(See Figure 3). Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 14 At each end of the network, termination resistors of 120ohms should be connected between ‘+’ and ‘-’ signals for proper impedance matching. BioEntry TX+ TXRX+ RX- BioEntry TX+ TXRX+ RX- BioEntry TX+ TXRX+ RX- RS-232 PC RX+ RXTX+ TX- Termination Resistor RS-485 Converter Connect cable shield to earth GND at one point only Termination Resistor Figure 3> A half duplex BioEntry network Warnings: To prevent ground loops and avoid communication problems, connect cable shield to earth GND at only one point. 2.5.4. Connecting via auxiliary interface The BioEntry series provide an auxiliary port to support connection to laptops, even if the device is not networked during installation. The user can access and manage the device with standard RS-232C port. Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass 2.6. BioEntry Installation Guide 15 Disassembling Remove screw at bottom of the BioEntry. Figure 4> Removing the screw Lift bottom of the housing, slide up and carefully remove it. Figure 5> Separating the case Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass 2.7. BioEntry Installation Guide 16 Mounting back plate Install back plate to wall surface. Figure 6> Installing back plate to the wall 2.8. Reassembling the BioEntry Figure 7> Reassembling the case Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass 3. BioEntry Installation Guide 17 Examples for BioEntry™ installation The BioEntry Smart/Pass offers various interfaces such as Wiegand input/output, general purpose I/O signals and communication ports that can be easily implemented to a security system, improving the security level. 3.1. Building a new system The BioEntry Smart/Pass is compatible with most access controllers with Wiegand interface. Building a new access control system with BioEntry is as simple and easy as with conventional Wiegand readers. In this section, the system with BioEntry only configuration is explained. The minimal configuration for BioEntry installation is illustrated in Figure 8. Data 0 Data 1 GND Access Controller POW+ 9~24Vdc POW_GND RX+ TX+ RXTX- (Optional for BioEntry Smart) EARTH Network To other controllers or host computer WO_D0 WO_D1 WO_GND To othe r BioEntry readers or host computer BioEntry TRX+ TRX- Figure 8> BioEntry connection diagram 3.1.1. Installing BioEntry Pass The BioEntry Pass series operates in 1:N matching mode, and stores up to 9000 fingerprint template data into internal flash memory, which is more than enough for most applications. The access control system is secured with Suprema’s fast and reliable 1:N matching algorithm. The user enrollment process is performed in the administrator’s computer, and the biometric data is distributed to each reader over the BioEntry Network. 3.1.2. Installing BioEntry Smart The BioEntry Smart series stores user’s fingerprint data in smartcards, easing user management and simplifying installation issues. The user enrollment process is performed in the administrator’s computer. The biometric data is stored in the smartcard which every user holds, instead of distributing it to each reader over the network. This simple architecture greatly Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 18 simplifies user management process and improves overall security, as the biometric data are physically isolated from the BioEntry, protecting them against possible vandalism. Moreover, as the user management process does not rely on network installation, total cost for installation is minimized. 3.2. Adding BioEntry to existing access control system Access control systems using Wiegand readers for user identification can be upgraded by adding BioEntry Pass in between Wiegand reader and access controller for improved security over legacy proximity card only based identification. The BioEntry Pass is configured to work in 1:1 matching mode. In this mode, user identification is performed in the following order: l The user places the proximity card on the Wiegand reader to initiate the identification process. l The Wiegand reader passes the user’s ID to the BioEntry Pass through Wiegand port. l The BioEntry Pass captures the user’s fingerprint, and performs 1:1 matching with the user’s fingerprint template data stored in the flash memory. l If the captured fingerprint and the one stored in the flash memory match, the BioEntry Pass sends the user’s ID to the access controller as if it were a Wiegand reader. l The access controller process the user ID for further authentication. Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide Network Actuator / Lock device Data 0 Data 1 GND Wiegand IN Data 0 Data 1 GND Wiegand OUT BioEntry Pass Access Controller Actuator / Lock device Network To other controllers or host computer Wiegand Reader To other BioEntry readers or host computer Access Controller To other controllers or host computer Data 0 Data 1 GND Wiegand signals Wiegand Reader 19 TX+ , RX+ TX- , RXTRX+ TRX- Figure 9> Adding BioEntry Pass to existing system Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 4. Specifications 4.1. Fingerprint Authentication Specifications 4.1.1. Fingerprint Authentication Performance EER* <0.1% Enrollment time <1 sec Verification time <1 sec 20 *EER is dependent on specific database 4.1.2. Fingerprint Sensor Specifications Model BioEntry OP BioEntry TC BioEntry FC Suprema UPEK TouchChip Atmel Fingerchip Optical sensor I TCS1CD AT77C101B-CB02 Sensor technology Optical Capacitive Thermal Capture method Touch Touch Swipe Sensing area 16.0mm x 19.0mm 12.8mm x 18.0mm 14.0mm x 0.4mm Image size(pixels) 272x320 256x360 360 x 500 Image resolution 500 dpi 508 dpi 500 dpi Device Name 4.1.3. Data storage Template capacity 9,000 at 4M Flash ( 19,000 at 8M ) LOG capacity 12,800 event 4.2. General Specifications 4.2.1. Operating range Parameter Symbol Supply voltage VIN Operating temperature (TC,OP) TOP 70 °C Operating temperature (FC) TOP -20 70 °C 85 Humidity (non-condensing) Copyright © 2005 by Suprema Inc. Rate 12 Units http://www.supremainc.com BioEntry Smart/Pass 4.3. 4.4. 4.5. BioEntry Installation Guide Parameter Symbol Min Typ. Max Units Supply current IDD 200 500 mA Wiegand Input Port Symbol Min Typ. Max Units High level input voltage VWIH 3.3 12 Low level input voltage VWIL -0.3 2.0 Wiegand Output Port Symbol Min Max Units High level output voltage VOH 5.0 Low level output voltage VOL 0.0 Current source/drain IO -1/20 mA Typ. 21 Smart card specifications Parameter Value Antenna type PCB loop antenna (60mm x 57mm) Connection with transceiver Permanent Manufacturer / Model Dual I, DE-KTFMI Operating Frequency Range 13.553 ~ 13.567MHz Duty cycle 100% Material information Component Material / Model Manufacturer PCB FR-4, Doosan Electronics Enclosure ABS, HF-380 LG Chem, Ltd. Battery CR2032 Hitachi Maxell, Ltd. RTC battery specification Parameter Value Model CR2032 Manufacturer Hitachi Maxell, Ltd. Nominal Voltage 3V Nominal Capacity 210mAh UL Recognition MH12568(N) Temp. range -20 ~ +85°C Copyright © 2005 by Suprema Inc. http://www.supremainc.com BioEntry Smart/Pass BioEntry Installation Guide 22 Contact Information Suprema Inc. DongCheon Bldg. 13-21 Yangjae-dong Seocho-gu Seoul 137-130 Korea Tel: +82-2-571-9202 Fax: +82-2-571-9306 Website: http://www.supremainc.com Sales inquires : sales@supremainc.com Technical inquires : support@supremainc.com Copyright © 2005 by Suprema Inc. http://www.supremainc.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 22 Creator : .歯.Microsoft Word Create Date : 2005:08:31 17:37:10 Title : .歯.BioEntry_Installation_Guide__0.96c_.doc Author : .歯.윤국경 Producer : Acrobat PDFWriter 5.0 Windows¿ëEXIF Metadata provided by EXIF.tools