INSTALLATION GUIDE
BioStation A2
English
Version 1.00
EN 101.00.BSA2 V1.00A
Contents
Safety instructions............................................................................................ 3
Introduction ...................................................................................................... 5
Components ...................................................................................................................................................5
Name and function of each part ...............................................................................................................6
Cables and connectors ......................................................................................................................................................8
How to enroll a fingerprint ........................................................................................................................9
Selecting a finger for fingerprint input ........................................................................................................................9
Fingerprint enroll method ................................................................................................................................................9
Installation ..................................................................................................... 10
Fixing the bracket and the product ........................................................................................................10
Power supply connection...........................................................................................................................11
Network connection ....................................................................................................................................11
TCP/IP ..................................................................................................................................................................................11
TTL input and output connection ............................................................................................................12
TTL input connection.......................................................................................................................................................12
Relay connection .........................................................................................................................................13
Fail Safe Lock ....................................................................................................................................................................13
Fail Secure Lock ................................................................................................................................................................13
Automatic door connection ............................................................................................................................................14
Connecting as a standalone......................................................................................................................15
Connecting to Secure I/O 2 ......................................................................................................................16
Wiegand connection ...................................................................................................................................17
Product specifications .................................................................................. 18
Dimensions ...................................................................................................................................................19
FCC compliance information ...................................................................... 20
EU Declaration of Conformity (CE) ........................................................... 20
Appendix ........................................................................................................ 21
Escape clause ...............................................................................................................................................21
Copyright notice ..........................................................................................................................................21
Safety instructions
Safety instructions
Observe the following instructions to use the product safely and prevent any risk of injury or property damage.
Warning
Noncompliance of instructions could lead to serious injury or death.
Installation
Do not install the product in a place with direct sunlight, moisture, dust, or soot.
•
A fire or electric shock may occur.
Do not install the product in a place with heat from an electric heater.
•
A fire or electric shock may occur due to overheating.
Install the product in a dry place.
•
Otherwise, a product damage or electric shock may occur due to moisture.
Install the product in a place with no electromagnetic interference.
•
Otherwise, a product damage or electric shock may occur.
The user should not install or repair the product independently.
•
•
A fire, electric shock, or personal injury may occur.
If the product has been damaged due to independent installation or repair of the product by the user, free A/S service will not be
provided.
Operation
Do not allow liquids such as water, beverages, or chemicals get into the product.
•
A fire, electric shock, or product damage may occur.
Caution
Noncompliance of instructions could lead to minor injury or product damage.
Installation
Do not install the power supply cable in a place where people pass by.
•
Product damage or physical injury may occur.
Do not install the product near a highly magnetic object such as a magnet, TV, (especially CRT) monitor, or speaker.
•
A product failure may occur.
Use only a power supply adaptor of D.C 12 V and 500 mA or higher.
•
If the proper power is not used, the product may not operate normally.
If installing the product outside where the product is completely exposed, it is recommended to install the product together with
the enclosure.
Use a separate power supply for Secure I/O 2, electric lock and BioStation A2 respectively.
•
If connecting and using the power supply to these devices together, the devices may malfunction.
Safety instructions
Operation
Do not drop the product or apply an impact to the product.
•
A product failure may occur.
Manage the password with care not to disclose it to others and change the password periodically.
•
Otherwise, illegal intrusion may occur.
Do not press the buttons on the product forcibly or using a sharp tool.
•
A product failure may occur.
Be careful not to contaminate or damage the fingerprint contact unit with a dirty hand or foreign substances.
•
Deterioration in fingerprint authentication performance and a product failure may occur.
When cleaning the product, wipe the product with a soft and dry cloth and no water, benzene or alcohol.
•
Otherwise, a product failure may occur.
BioStation A2 uses capacitive buttons. If the environment is moist from wet weather or the product surface is smeared with a lot of
water, wipe off the product with a dry towel before using it.
RTC battery
Replacing the battery with an incorrect type of battery may cause explosion.
Discard the battery according to the appropriate regional or international waste regulations.
Introduction
Introduction
Components
PVC anchor
(4 EA)
BioStation A2
Wall bracket
Connection cable
(2 pins 1 EA, 3 pins 2 EA, 4 pins 4 EA)
Ferrite core
(1 EA)
120 Ω resistor
(1 EA)
Drilling template
Note
Components may vary according to the installation environment.
Diode
(1 EA)
Fixing screw
(4 EA)
Quick guide
Introduction
Name and function of each part
Microphone
Camera
LCD screen
LED lamp
Speaker
Fingerprint authentication unit
Home button
RF card authentication unit
Menu button
Cancel button
Mini USB cable slot
USB memory slot
Ethernet
TTL input (4 pins)
Relay 0 (3 pins)
Wiegand input (4 pins)
Relay 1 (3 pins)
Wiegand output (4 pins)
RS-485 (4 pins)
Booting mode button
Power supply (2 pins)
Name
Description
Microphone
Delivers the voice of the user when the interphone is connected.
LCD screen
Provides UI for operation.
Menu button (
Displays the list of menus.
Home button (
Navigates to the home screen.
Cancel button (
Navigates back to the previous screen.
Speaker
Delivers sound.
LED lamp
Indicates the operational status of the product with the color of the LED lamp.
Fingerprint authentication unit
Part to scan the fingerprint for entrance.
RF card authentication unit
Part to scan the card for entrance.
USB memory slot
Connects USB memory.
Mini USB cable slot
Will be supported in the future.
TTL input (4 pins)
Connect the TTL input and output cable.
Introduction
RS-485 (4 pins)
Connect the RS-485 cable.
TTL output (4 pins)
Connect the TTL input and output cable.
Relay 0, 1 (3 pins)
Connect the relay cable.
Power supply (2 pins)
Connect the power supply cable.
Ethernet
Connect the Ethernet cable.
Wiegand input (4 pins)
Connect the Wiegand input and output cable.
Wiegand output (4 pins)
Connect the Wiegand input and output cable.
Introduction
Cables and connectors
Power supply
Pin
Name
Color
Power +12 V
Power GND
Red (white stripe)
Black (white stripe)
Pin
Name
Color
Normally Open
Common
Normally Closed
White
Blue
Orange
Pin
Name
Color
TRX +
TRX GND
Shield GND
Blue
Yellow
Black
Gray
Pin
Name
Color
IN 0
IN 1
GND
Shield GND
Red
Yellow
Black
Gray
Pin
Name
Color
IN 0 / OUT 0
IN 1 / OUT 1
GND
Shield GND
Green
White
Black
Gray
Relay
RS-485
TTL input
Wiegand input and output
Introduction
How to enroll a fingerprint
In order to improve the fingerprint authentication rate, register the fingerprint correctly. BioStation A2 can recognize a fingerprint even if
the angle and position of a user's fingerprint input change. If you register the fingerprint with attention to the following matters, the
authentication rate can be improved.
Selecting a finger for fingerprint input
•
In preparation for the case that the fingerprint of a specific finger cannot be used, for example if
the user is lifting a load with one hand or a finger gets hurt, up to 10 fingerprints for each user can
be registered.
•
In the case of a user whose fingerprint cannot be recognized well, the authentication rate can be
improved by enrolling the same finger twice repeatedly.
•
If a finger has a cut or the fingerprint is blurry, select another finger for the fingerprint.
•
It is recommended to use the index finger or the middle finger when scanning the fingerprint. The
authentication rate can be reduced if it is difficult to place another finger at the center of
fingerprint sensor accurately.
Fingerprint enroll method
When a message saying “Scan the fingerprint.” is displayed on the LCD screen for enrolling the fingerprint, place the finger with the
fingerprint to be registered on the fingerprint authentication unit and press the finger gently for better authentication.
When the re-input screen is displayed after a beep sound, scan the fingerprint of the registered finger again (scan the fingerprint of a
finger to be registered twice).
Note
Cautions for enrolling a fingerprint
When a fingerprint is recognized, it is compared with the initially registered fingerprint, so the initial fingerprint enroll is the most important. Pay
attention to the following matters when enrolling the fingerprint.
•
Place the finger deep enough to contact with the sensor completely.
•
Place the center of the fingerprint in the center of the sensor.
•
If a finger has a cut or the fingerprint is blurry, select another finger for the fingerprint.
•
Scan the fingerprint correctly without moving according to the instruction on the screen.
•
If you make the finger upright so that the contact area with the sensor has decreased or the angle of finger has warped, fingerprint authentication
may not be performed.
When the fingerprint recognition fails
BioStation A2 can recognize a fingerprint regardless of a change of season or finger condition. However, the authentication rate may vary according to
the external environment or fingerprint input method.
If the fingerprint authentication cannot be done smoothly, it is recommended to take the following measures.
• If the finger is smeared with water or sweat, dry off the finger and then scan the finger.
•
If the finger is too dry, blow your breath on the fingertips and then scan the finger.
•
If the finger has a cut, register the fingerprint of another finger.
•
The initially registered fingerprint often may have not been scanned correctly, so register the fingerprint again according to ‘Cautions for enrolling
a fingerprint’.
Installation
Installation
Fixing the bracket and the product
Determine the correct position to install the bracket using the provided drilling template. Fix the bracket firmly using fixing screws
through the bracket to the position where BioStation A2 will be installed.
Note
If installing BioStation A2 on a concrete wall, drill holes, insert PVC anchors, and fix them with fixing screws.
Assemble the cable cover and install BioStation A2 onto the fixed bracket.
Connect BioStation A2 to the bracket by rotating the product fixing screw of BioStation A2.
10
Installation
Power supply connection
UPS
(Optional)
DC power
1 - Power +12 V
2 - Power GND
Red (white stripe)
Red (white stripe)
BioStation A2
Note
•
•
Use a power supply adaptor of DC 12 V (± 10%) with a minimum of 1,500 mA which has obtained the approval of IEC/EN 60950-1. If you wish to
connect and use another device to the power supply adaptor, you should use an adaptor with a current capacity which is the same or larger than
the total power consumption required for the terminal and another device.
Use a separate power supply for Secure I/O 2, the electric lock, and the product respectively. If connecting and using the power supply to these
devices together, the devices may malfunction.
Network connection
TCP/IP
LAN connection (connecting to a hub)
You can connect the product to a hub using a general type CAT-5 cable.
Hub
BioStation A2
PC
11
Installation
LAN connection (connecting to a PC directly)
BioStation A2 has an automatic MDI/MDIX function so that it can be connected to a PC directly using a normal straight type CAT-5 cable,
not a cross cable.
BioStation A2
PC
TTL input and output connection
TTL input connection
1234-
IN 0
IN 1
GND
Shield GND
Cable shield (optional)
Door button
Door sensor
BioStation A2
12
Red
Yellow
Black
Gray
Installation
Relay connection
Fail Safe Lock
In order to use the Fail Safe Lock, connect N/C relay as shown in the figure below. There is normally a current flowing through the relay for
the Fail Safe Lock. When the relay is activated, blocking the current flow, the door will open. If the power supply to the product is cut off due
to a power failure or an external factor, the door will open.
2 - Common
3 - Normally Closed
Dead bolt /
Door strike
Blue
Orange
DC power
BioStation A2
Note
•
•
•
Install a diode at both sides of the door lock wire as shown in the figure to protect the relay from the reverse current, which occurs when the door
lock operates.
Take caution of the installation direction of the diode. Install the diode close to the door lock.
Use a separate power supply for BioStation A2 and the door lock.
Fail Secure Lock
In order to use the Fail Secure Lock, connect N/O relay as shown in the figure below There is normally no current flowing through the relay
for the Fail Secure Lock. When the current flow is activated by the relay, the door will open. If the power supply to the product is cut off due
to a power failure or an external factor, the door will lock.
1 - Normally Open
2 - Common
Dead bolt /
Door strike
White
Blue
DC power
BioStation A2
Note
•
•
•
Install a diode at both sides of the door lock wire as shown in the figure to protect the relay from the reverse current, which occurs when the door
lock operates.
Take caution of the installation direction of the diode. Install the diode close to the door lock.
Use a separate power supply for BioStation A2 and the door lock.
13
Installation
Automatic door connection
1 - Normally Open
2 - Common
White
Blue
Door button
Detection sensor
Automatic door
control device
Door lock
BioStation A2
14
Installation
Connecting as a standalone
BioStation A2 can be connected to the door lock, door button, and door sensor directly without connecting a separate I/O device.
Cable shield (optional)
TTL connection
1 - IN 0
2 - IN 1
3 - GND
4 - Shield GND
Red
Yellow
Black
Gray
TTL
Door button
Relay connection
1 - Normally Open
2 - Common
3 - Normally Closed
BioStation A2
Door sensor
Relay
White
Blue
Orange
Fail Secure Lock
or
Fail Safe Lock
DC power
Hub
Dead bolt /
Door strike
Power
DC power
PC
Power supply connection
1 - Power +12 V
Red (white stripe)
2 - Power GND
Black (white stripe)
Note
•
•
•
•
•
BioStation A2 can be used as a multi-door controller with the slave devices with the RS485 cable. The slave devices are used as dummy readers and
authentication is performed in the master device.
If Xpass is connected to the master device, only card authentication can be used.
The maximum number of slave devices available to connect varies according to the authentication method, number of users, and number of
devices. Also note that the number of slave devices affects the fingerprint authentication speed.
A master device can control 31 slave devices. The bandwidth of RS485 allows for up to 7 fingerprint authentication devices to be connected.
For more information, contact the Suprema technical support team (support@suprema.co.kr).
15
Installation
Connecting to Secure I/O 2
Secure I/O 2 is an I/O device, can be connected to BioStation A2 with the RS-485 cable. Security can be maintained even if the connection
between BioStation A2 and Secure I/O 2 has been lost or the power supply to BioStation A2 has been shut off due to external factors.
• Use an AWG24 twisted pair with a maximum length of 1.2 km for the RS-485 cable.
•
If connecting with a RS-485 daisy chain, connect the termination resistor (120 Ω) to both ends of the daisy chain connection. If
connected to the middle line, the signal level becomes smaller and the communication performance will deteriorate. Make sure to
connect it to both ends of the daisy chain connection.
RS-485 connection
1 - TRX +
2 - TRX 3 - GND
4 - Shield GND
Power supply connection
1 - Power +12 V
Red (white stripe)
2 - Power GND
Black (white stripe)
Blue
Yellow
Black
Gray
Cable shield (optional)
RS-485
DC power
Power
BioStation A2
DC power
Secure I/O 2
Hub
DC power
Door sensor
Door lock
PC
Door button
Note
•
•
•
•
•
BioStation A2 can be used as a multi-door controller with the slave devices with the RS485 cable. The slave devices are used as dummy readers and
authentication is performed in the master device.
If Xpass is connected to the master device, only card authentication can be used.
The maximum number of slave devices available to connect varies according to the authentication method, number of users, and number of
devices. Also note that the number of slave devices affects the fingerprint authentication speed.
A master device can control 31 slave devices. The bandwidth of RS485 allows for up to 7 fingerprint authentication devices to be connected.
For more information, contact the Suprema technical support team (support@suprema.co.kr).
16
Installation
Wiegand connection
Use as a Wiegand input device
Cable shield (optional)
RFID reader
1234-
IN 0
IN 1
GND
Shield GND
Green
White
Black
Gray
BioStation A2
Use as a Wiegand output device
Cable shield (optional)
Controller
1234-
OUT 0
OUT 1
GND
Shield GND
Green
White
Black
Gray
17
BioStation A2
Product specifications
Product specifications
Category
General
Feature
Biometric
Fingerprint
LFD
Supported
RF Option
Storage
capacity
Interface
Relay
Hardware
Specification
2.4 GHz, 125 kHz Mifare/DesFire/DesFire EV1/Felica/NFC, 125 kHz
iClass SE
Max. User (1:1)
500,000
Max. User (1:N)
100,000
Max. Template (1:1)
1,000,000
Max. Template (1:N)
200,000
Max. Text Log
5,000,000
Max. Image Log
50,000
Wi-Fi
Supported
TCP/IP
Supported
RS-485
1ch Host or Slave (Selectable)
RS-232
Supported
Wiegand
1ch Input, 1ch Output
TTL input
1ch Input
Relay
2 Relay
USB
USB 2.0 (Host)
Voltage
Max. 24 V DC
Current
0.5 A, Max. 1.A
CPU
1.0 GHz
Memory
8 GB Flash + 1 GB RAM
LCD
5” color touch LCD
LED
Multiple colors
Sound
24 bit/Voice DSP (echo cancel)
Operating temperature
-20°C ~ 50°C
Temper
Supported
Power
9 V ~ 18 V
PoE
Supported
Dimension (W x H x D mm)
155 x 155 x 40
Certificates
CE, FCC, KC, RoHS, REACH, WEEE
18
Product specifications
Dimensions
(Unit: mm)
19
FCC compliance information
FCC compliance information
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment under FCC rules.
This appliance and its antenna must not be co-located or operation in conjunction with any other antenna or transmitter.
A minimum separation distance of 20 cm must be maintained between the antenna and the person for this appliance to satisfy the RF
exposure requirements.
EU Declaration of Conformity (CE)
This product is CE marked according to the provisions of the R&TTE Directive(1999/5/EC). Hereby, Suprema Inc. declares that this product is
in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. This device is Class 1 radio equipment
under the European Radio and Telecommunications Terminal Equipment (R&TTE) Directive (1999/5/EC).
For more information, contact us at the following contact information.
Suprema Inc.
Website: https://www.supremainc.com
Address: Parkview Tower F16, 248, Jeongjail-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea (Jeongja-dong 6)
Tel: +82-31-783-4502 / Fax: +82-31-783-4503
20
Appendix
Appendix
Escape clause
•
The information in this manual is provided with regard to the Suprema's products.
•
The right to use is acknowledged only for products included in the terms and conditions of the sales agreement guaranteed by
Suprema. The right of license to other intellectual property rights not discussed in this manual is not acknowledged.
•
Suprema does not guarantee or hold responsibility for the suitability and commerciality of the product for a specific purpose, or the
infringement of patent, copyright, or other intellectual property rights with regard to sales or usage of Suprema's products.
•
Do not use the product of Suprema under the situations related to medical, rescue of human lives, or maintenance of life, as a person
may get injured or lose his/her life due to product malfunction. If an accident occurs while a consumer is using the product under the
situations described as examples above, employees, subsidiaries, branches, affiliated companies and distributors of Suprema do not
accept responsibility nor will they reimburse for all related direct and indirect expenses or expenditure including attorney fees even if
the consumer has discovered any shortcomings in the product design or manufacturing process and claims this as a significant fault.
•
Suprema may modify the product size and specifications at any time without proper notice in order to improve the safety, function and
design of the product. Designers must keep in mind that functions or descriptions indicated as "to be implemented" or "undefined"
may change at any time. Suprema will implement or define such functions or descriptions in the near future and Suprema accepts no
responsibility for compatibility issues and any other problems arising from such compatibility issues.
•
If you wish to obtain the newest specifications before ordering the product, contact Suprema through a Sales Representative or local
distributor of Suprema.
Copyright notice
The copyright of this document is vested in Suprema. The rights of other product names, trademarks and registered trademarks are vested
in each individual or organization that owns such rights.
21
www.supremainc.com
www.supremainc.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : SUPREMA Inc.
Create Date                     : 2015:11:03 14:07:31+09:00
Modify Date                     : 2016:04:04 18:04:17+09:00
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2016:04:04 18:04:17+09:00
Creator Tool                    :  Word용 Acrobat PDFMaker 15
Document ID                     : uuid:363db170-6292-48ff-b1a9-c28fa7fa9252
Instance ID                     : uuid:7d3020f6-138a-4f55-96dd-e08bf716f0dc
Subject                         : 2
Format                          : application/pdf
Creator                         : SUPREMA Inc.
Producer                        : Adobe PDF Library 15.0
Source Modified                 : D:20151103050654
Company                         : Saltlux
Page Layout                     : SinglePage
Page Mode                       : UseOutlines
Page Count                      : 22
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TKWBSA2-OEPW

Navigation menu