Suprema XPD2-GKDBS XPD2-GKDBS User Manual

Suprema Inc. XPD2-GKDBS

User Manual

XPass D2(XPD2-GKDBS, XPD2-GDBS, XPD2-GKDB, XPD2-GDB) INSTALLATION GUIDEEN 101.00.XPD2-GKDB V1.00AVersion 1.00English
Contents     Safety instructions ............................................................................................ 3 Introduction ...................................................................................................... 5 Components ................................................................................................................................................... 5 Name and function of each part ............................................................................................................... 6 Cables and connectors ...................................................................................................................................................... 7 Installation ........................................................................................................ 8 Fixing the bracket and the product .......................................................................................................... 8 Cable connection ......................................................................................................................................... 10 Power supply connection ..................................................................................................................................................10 RS-485 connection .............................................................................................................................................................10 Wiegand and other cable connections ........................................................................................................................11 Restoring the Factory Defaults .................................................................................................................... 11 Resetting the baud rate of RS-485 ............................................................................................................... 11 Product specifications .................................................................................. 12 Dimensions ................................................................................................................................................... 13 FCC compliance information ...................................................................... 14 Appendices ..................................................................................................... 15 Disclaimers ................................................................................................................................................... 15 Copyright notice .......................................................................................................................................... 15 Open Source License .................................................................................................................................... 15 MIT License ........................................................................................................................................................................15
 Safety instructions 3 Safety instructions Observe the following instructions to use the product safely and prevent any risk of injury or property damage.  Warning Noncompliance of instructions could lead to serious injury or death. Installation Do not install the product in a place with direct sunlight, moisture, dust, or soot. • A fire or electric shock may occur. Do not install the product in a place with heat from an electric heater. • A fire or electric shock may occur due to overheating. Install the product in a dry place. • Otherwise, a product damage or electric shock may occur due to moisture. Install the product in a place with no electromagnetic interference. • Otherwise, a product damage or electric shock may occur. The user should not install or repair the product independently. • A fire, electric shock, or personal injury may occur.   • If the product has been damaged due to independent installation or repair of the product by the user, free A/S service will not be provided. Operation Do not allow liquids such as water, beverages, or chemicals get into the product.   • A fire, electric shock, or product damage may occur.   Caution Noncompliance of instructions could lead to minor injury or product damage.   Installation Do not install the power supply cable in a place where people pass by. • Product damage or physical injury may occur.   Do not install the product near a highly magnetic object such as a magnet, TV, (especially CRT) monitor, or speaker. • A product failure may occur. If installing the product outside where the product is completely exposed, it is recommended to install the product together with the enclosure. Keep the minimum separation distances between the devices when install multiple devices. • Otherwise, RF performance is affect to the other device, the devices may not operate normally.
 Safety instructions 4 Operation Do not drop the product or apply an impact to the product. • A product failure may occur. When cleaning the product, wipe the product with a soft and dry cloth and no water, benzene or alcohol.   • Otherwise, a product failure may occur.
Introduction 5 Introduction Components NOTE •Components may vary according to the installation environment. XPass D2 Wall Bracket PVC Anchor x 2 Wall Fixing Screw x 2 120  Ω  resistor Open Source Software Guide Bracket Fixing Screw (Star Shaped) Drilling Template Quick Guide Shrink Tube
Introduction 6 Name and function of each part Name Description LED lamp Indicates the operational status of the device with the color of the LED lamp. Keypad Used to authenticate by entering the user ID directly. If you want to enter the ID directly, change the authentication method settings in BioStar 2. •0 ~ 9: Enters number.•: Separates the FC code from the ID when entering the Wiegand card ID.•: Used to finish entering.RF card authentication unit Reads RF cards for entering and exiting. Reset button Initialize the device. Cable •Power cable•RS-485 cable•Wiegand output cable•LED input cable•Beep  input cable•Tamper cableRF card authentication unit LED lamp Reset button Cable Keypad
 Introduction 6 Name and function of each part    Name Description LED lamp Indicates the operational status of the device with the color of the LED lamp. RF card authentication unit Reads RF cards for entering and exiting. Reset button Initialize the device. Cable • Power cable • RS-485 cable • Wiegand output cable • LED input cable • Beep Input cable • Tamper cable   RF card authentication unit LED lamp Reset button Cable
 Introduction 7 Cables and connectors    Pin Name Color 1 PWR +VDC Red 2 GND Black (White stripe) 3 485 TRXN Yellow (Black stripe) 4 485 TRXP Blue  (White stripe) 5 WG D0 Green 6 WG D1 White 7 LED RED Orange 8 LED GRN Brown 9 BEEP Purple 10 TMPR Gray
 Introduction 6 Name and function of each part    Name Description LED lamp Indicates the operational status of the device with the color of the LED lamp. RF card authentication unit Reads RF cards for entering and exiting. Reset button Initialize the device. Cable • Power cable • RS-485 cable • Wiegand output cable • LED input cable • Beep Input cable • Tamper cable   RF card authentication unit LED lamp Reset button Cable
Installation 8 Installation Fixing the bracket and the product 1  Determine the correct position to install the bracket using the provided drilling template. Fix the bracket firmly using fixingscrews through the bracket to the position where XPass D2 will be installed. NOTE •If installing XPass D2 on a concrete wall, drill holes, insert PVC anchors, and fix them with fixing screws. •To avoid RF interference, a minimum separation distance must be maintained. Wall thickness Distance 100 mm  400 mm 120 mm 380 mm 150 mm 380 mm Wall 430  mm Wall Wall thickness Distance Wall 430  mm Wall Wall thickness Distance
Installation 9 2  Install XPass D2 onto the fixed bracket.3  Assemble  XPass D2 with the bracket by rotating the product fixing screw.NOTE •When assembling the product with the bracket, you can use the included bracket fixing screw(Star Shaped) instead of the product fixing screw for enhanced security. Wall Wall Wall Wall
 Installation 10 Cable connection XPass D2 can be used as an RFID card reader by connecting to a master device or a CoreStation. Power supply connection   NOTE • Use a power supply adaptor of DC 12 V (± 10%) with a minimum of 1,500 mA which has obtained the approval of IEC/EN 60950-1. If you wish to connect and use another device to the power supply adaptor, you should use an adaptor with a current capacity which is the same or larger than the total power consumption required for the terminal and another device.    RS-485 connection   NOTE • Use an AWG24 twisted pair with a maximum length of 1.2 km for the RS-485 cable. • If connecting with a RS-485 daisy chain, connect the termination resistor (120 Ω) to both ends of the daisy chain connection. If connected to the middle line, the signal level becomes smaller and the communication performance will deteriorate. Make sure to connect it to both ends of the daisy chain connection.   1 - PWR +VDC Red   2 - GND Black (White stripe) 3 - 485 TRXN Yellow (Black stripe) 4 - 485 TRXP Blue (White stripe) Control  device  XPass D2 DC power XPass D2 1 - PWR +VDC Red 2 - GND Black (White stripe) DC power
 Installation 11 Wiegand  and other cable connections   Restoring the Factory Defaults   This will delete all data and root certificate on the device and reset the settings. 1  Turn the power on.   2  Press the reset button three times quickly. 3  When the yellow LED is blinking, press the reset button again.  NOTE • If there is no root certificate on the device, you cannot restore the factory defaults.    Resetting the baud rate of RS-485   1  Turn the power on.   2  Press and hold the reset button for more than 2 seconds. When the device change to setup mode, the yellow LED is blinking. 3  Depending on the number of times the reset button was pressed, the baud rate changes. You can recognize the baud rate according to the LED color.  The number of times  Baud Rate LED Color 1 9600 Cyan 2 19200 Blue 3 38400 Magenta 4 57600 White 5 115200 Red  4  The LED blinks for 5 seconds with the color set as the above. The baud rate is set once you hear a beep sound.  NOTE • If you do not press the reset button after changing to the setup mode, the baud rate is set to 115200.      1 - PWR +VDC Red   2 - GND Black  (White stripe) 5 - WG D0 Green 6 - WG D1 White 7  -  LED RED Orange 8  -  LED GRN Brown 9  -  BEEP Purple 10  -  TMPR Gray Control device XPass D2 DC power
 Product specifications 12 Product specifications Category Feature Specification XPD2-GKDB Credential LF  card option EM HF card option MIFARE, MIFARE Plus, DESFire/EV1, FeliCa NFC card Supported BLE card Supported RF read range * MIFARE/DESFire/EM : 50 mm, FeliCa: 30 mm General CPU 80 MHz Memory 256 KB  Flash + 64 KB RAM LED Multi-color Sound Multi-tone Buzzer Operating temperature -35  °C - 65  °C   Storage temperature -40 °C - 70 °C Operating humidity 0%  -  95  %, non-condensing Storage humidity 0%  -  95  %, non-condensing Dimension (W x H x D) 80 mm x 130 mm x 25 mm Weight Device:  145  g Bracket:  52 g (Including washer and bolt) IP rating IP65, IP67 IK rating IK08 Certificates CE, FCC, KC, RoHS, REACH, WEEE, SIG Interface RS-485 1ch Wiegand 1ch LED 2ch Beep 1ch Tamper Supported Electrical Power Voltage: DC 12 V,  Current: Max. 400 mA * Use 12 VDC, 1.5A power supply. LED, Beep input VIH Min.  3  V Max. 5  V LED, Beep input VIL Max. 1  V LED, Beep Pull-up resistance 4.7kΩ (The input ports are pulled up with 4.7kΩ.) Wiegand  output VOH Min.  4.8  V Wiegand output VOL Max. 0.2  V Wiegand output Pull-up   resistance Internally pulled up with 1 kΩ  * RF read range will vary depending on the installation environment.
 Product specifications 13 Dimensions (Unit: mm) * The tolerance is ±0.3mm.    25 72.4 116.1 130 80
Product specifications 13 Dimensions (Unit: mm) * The tolerance is ±0.3mm.72.4 116.1 130 80 25
FCC compliance information 14 compliance information Copyright notice The copyright of this document is vested in Suprema. The rights of other product names, trademarks and registered trademarks are vested in each individual or organization that owns such rights. Warning & Safety Information
Appendices 15 Appendices Disclaimers •The information in this manual is provided with regard to the Suprema's products. •The right to use is acknowledged only for products included in the terms and conditions of the sales agreement guaranteedby Suprema. The right of license to other intellectual property rights not discussed in this manual is not acknowledged. •Suprema does not guarantee or hold responsibility for the suitability and commerciality of the product for a specific purpose,or the infringement of patent, copyright, or other intellectual property rights with regard to sales or usage of Suprema'sproducts. •Do not use the product of Suprema under the situations related to medical, rescue of human lives, or maintenance of life, as aperson may get injured or lose his/her life due to product malfunction. If an accident occurs while a consumer is using theproduct under the situations described as examples above, employees, subsidiaries, branches, affiliated companies anddistributors of Suprema do not accept responsibility nor will they reimburse for all related direct and indirect expenses orexpenditure including attorney fees even if the consumer has discovered any shortcomings in the product design ormanufacturing process and claims this as a significant fault. •Suprema may modify the product size and specifications at any time without proper notice in order to improve the safety,function and design of the product. Designers must keep in mind that functions or descriptions indicated as "to beimplemented" or "undefined" may change at any time. Suprema will implement or define such functions or descriptions in the near future and Suprema accepts no responsibility for compatibility issues and any other problems arising from suchcompatibility issues. •If you wish to obtain the newest specifications before ordering the product, contact Suprema through a Sales Representativeor local distributor of Suprema. Copyright notice The copyright of this document is vested in Suprema. The rights of other product names, trademarks and registered trademarks are vested in each individual or organization that owns such rights. Open Source License MIT License Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions: The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software. THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
Suprema Inc.17F Parkview Tower, 248, Jeongjail-ro, Bundang- gu, Seongnam-si, Gyeonggi-do, 13554, Rep. of KOREATel: +82 31 783 4502   I   Fax: +82 31 783 4503   I   Inquiry: sales@supremainc.com©2018 Suprema Inc. Suprema and identifying product names and numbers herein are registered trade marks of Suprema, Inc. All non-Suprema brands and product names are trademarks or registered trademarks of their respective companies. Product appearance, build status and/or specifications are subject to change without notice.  Appendix Escape clause •The information in this manual is provided with regard to the Suprema's products. •The right to use is acknowledged only for products included in the terms and conditions of the sales agreement guaranteed bySuprema. The right of license to other intellectual property rights not discussed in this manual is not acknowledged. •Suprema does not guarantee or hold responsibility for the suitability and commerciality of the product for a specific purpose, or theinfringement of patent, copyright, or other intellectual property rights with regard to sales or usage of Suprema's products. •Do not use the product of Suprema under the situations related to medical, rescue of human lives, or maintenance of life, as a personmay get injured or lose his/her life due to product malfunction. If an accident occurs while a consumer is using the product under the situations described as examples above, employees, subsidiaries, branches, affiliated companies and distributors of Suprema do notaccept responsibility nor will they reimburse for all related direct and indirect expenses or expenditure including attorney fees even ifthe consumer has discovered any shortcomings in the product design or manufacturing process and claims this as a significant fault. •Suprema may modify the product size and specifications at any time without proper notice in order to improve the safety, function and design of the product. Designers must keep in mind that functions or descriptions indicated as "to be implemented" or "undefined"may change at any time. Suprema will implement or define such functions or descriptions in the near future and Suprema accepts no responsibility for compatibility issues and any other problems arising from such compatibility issues. •If you wish to obtain the newest specifications before ordering the product, contact Suprema through a Sales Representative or localdistributor of Suprema. Suprema UK. 9 New Street Chambers, 67A New Street, Birmingham, B2 4DU Tel. +44 (0) 800 368 8123

Navigation menu