Suprema XPH XPASS User Manual xpass 1209 1

Suprema Inc. XPASS xpass 1209 1

User manual

Safety precautionsProduct componentsOptional accessoriesNames of each parts Product DimensionCables and Connectors Power ConnectionLAN Connection RS485 ConnectionRelay ConnectionDigital Input Connection WiegandInput/OutputOutput Installation of Wall-mount Bracket Installation Reference Specification Electrical SpecificationFCC RulesContents
The list below is to keep user s safety and prevent any loss. Please read safety precautions carefully before use.Do not install the device in a place subject to direct sun light, humidity, dust or soot.Do not place a magnet near the product. Do not place the device next to heating equipments.Be careful not to let liquid like water, drinks or chemicals leak inside the device.Clean the device often to remove dust on it.In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. Safety precautionsIt may cause a damage or a failure to the product.It may cause a failure.
Do not drop the device. Do not damage the device.Do not disassemble, repair or alter the device.Do not let children touch the devicewithout supervision.Do not use the device for any other purpose than specified.Contact your nearest dealer in case of a trouble or problem. The warranty does net apply to any product damage cause by an arbitrary installation or repair.Safety precautionsThe list above is to keep user s safety and prevent any loss. Please read safety precautions carefully before use.
ProductcomponentsXpass bracketWall mounting screws(2 ea)Knife Blocks(2 ea)Shrinkable Tubes Software CDExtended Ethernet CableBasic componentsThe components shown above may differ depending on the installation environment.
Plastic standSecure I/OOptional accessoriesExtended bracket adaptor
Names of each parts
LED status
Product Dimension< Extended bracket >< Front View > < Bracket >< Side View >(unit : mm)
No Pin Name Color1485 GND White (black string)2Wiegand-GND Black3485 - Yellow (black string)4Wiegand-1 White5485 + Blue (white string)6Wiegand-0 Green7Input-1 Brown8 Relay Open Gray (white string)9Input-GND Gray10 Relay Com Green (white string)11 Input-0 Purple12 Relay Close Orange (black string)13 TX+ (LAN) Pink14 Power IN+ Red15 TX-(LAN) Orange16 Power IN- Black (white string)17 RX+ (LAN) Blue18 Power OUT+ Light Blue19 RX-(LAN) Yellow20 Power OUT- Black (white string)21 VB1 black string)22 VB2 Brown (white string)23 VB1 black string)24 VB2 Brown (white string)Cables and Connectors
Pin Pin Name Color1RelayRLY NC Orange (black string)2RLY COM Green (white string)3RLY NO Gray (white string)4WiegandWGD D0 Green5WGD D1 White6WGD GND Black7SwitchIN 0 Purple8IN 1 Brown9IN GND Gray10485485+ Blue (white string)11 485- Yellow (black string)12 485 GND White (black string)Cables and ConnectorsPin Pin NamePowerPOWER OUT - Black (white string)POWER OUT + Light Blue3POWER IN - Black (white string)1POWER IN +  RedCable Specification
Ethernet extension cablePin Pin Name Color1LANRX- Yellow2 RX+ Blue3TX- Orange4TX+ Pink5VB1 black string)6VB1 black string)7VB2 Brown (white string)8VB2 Brown (white string)LAN cableModular Jack (A) Connector (B) Pin Name ColorTX+ BlueTX- OrangeRX+ BlackRX- YellowVB1 RedVB1 GreenVB2 BrownVB2 Gray
Power Connection112V  10%, at least 500mA.Comply with standard IEC/EN 60950-1.To share the power with other devices, use a power supply with higher current ratings.Recommended power supplyPin Pin Name Color14 POWER IN+ Red16 POWER IN- Black (white string)
Power Connection2Please use the distance of LAN cable within 100m in case of POE power.Recommended power supply
LAN Connection
LAN Connection (Direct connection with PC)
RS485 Connection for Host CommunicationPin Pin Name Color1485 GND White (black string)3485 - Yellow (black string)5 485 + Blue (white string)
RS485 Connection for Secure I/OMax number of devicesPin Pin Name Color1485 GND White (black string)3485 - Yellow (black string)5 485 + Blue (white string)Maximum eight(8) devices (including Master) interworksin an RS485 loop.
Relay Connection "Fail safe lockPin Pin Name Color10 RLY COM Green (white string)12 RLY NC Orange (black string)
Relay Connection "Fail secure lockPin Pin Name Color8RLY NO Gray (white string)10 RLY COM Green (white string)
Relay Connection -Automatic doorPin Pin Name Color8RLY NO Gray (white string)10 RLY COM Green (white string)
Digital Input Connection (Alarm, Emergency S/W)Pin Pin Name Color7IN 1 Brown9IN GND Gray11 IN 0 Purple
Digital Input Connection (RTE, Door sensor)Pin Pin Name Color7IN 1 Brown9IN GND Gray11 IN 0 Purple
WiegandInputWiegandInput/OutputWiegandOutputPin Pin Name Color2WGD GND Black4WGD D1 White6WGD D0 GreenPin Pin Name Color2WGD GND Black4WGD D1 White6WGD D0 Green
OutputPin Pin Name Color10 RLY COM Green (white string)12 RLY NC Orange (black string)18 PWR OUT + Light Blue20 PWR OUT - Black (white string)Caution : Max. 700mA is supplied using adapter for the external output. Be careful to satisfy the power capacity in use.
Fix wall mount bracket on a wall usingwall mounting screwsHook Xpasson the wall mount bracketInstallation of Wall-mount BracketFix Xpassand wall mounting bracket usinga wall mounting screw.
Installation Reference 1 -Stand alone
Installation Reference 2 "Standalone (Secure)
Installation Reference 3 "Network
SpecificationCPU  32 bit Micro-processorMemory 8MB FLASH + 16MB SDRAM RF Card13.56 MHz Mifare(XPM)125 KHz EM Prox(XPE)125 KHz HID Prox(XPH)User Capacity 40000 userLog Capacity 50000 logNetwork interfaces TCP/IP, RS485 IP Rate IP 65 classSound  Multi-tone buzzerLED Multi-color LED RTC  Lithium-ion rechargeable batteriesI/ORelay x 1Tamper x 1Switch input x 2 Wiegandx 1Power 12Vdc, POEOperating Temperature -20 ~ 50 C Size 45 x 130 x 27mm (W x H x D ) Certificates CE, FCC, KCC, IP65It may be occurred the risk of explosionfor improper replacement of battery. Please use the specified battery according to proper instruction.Caution for RTC Battery
Min. Typ. Max. NotesPowerVoltage (V) 10.8 12 13.2 Use regulated DC power adaptor onlyCurrent (mA) - 140Switch InputVIH (V) - TBD -VIL (V) - TBDPull-up resistance ( ) - 4.7k - The input ports are pulled up with 4.7k resistorsTTL/WiegandOutputVOH (V) - 5 -VOL (V) - 0.8 -Pull-up resistance ( ) - 4.7k - The outputs ports are open drain type, pulled up with 4.7k resistors internallyRelaySwitching capacity (A) - - 10.330V DC125V ACSwitching power (resistive) - -30W37.5VADCACSwitching voltage (V) - - 110125DCACElectrical Specification
Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user s authority to operate the equipment.This device complies with part 15 of the FCC Rules. Operation issubject to the following two conditions: (1) This device may not cause harmful interface, and (2) this device must accept any interface received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference ina residential installation. This equipment generates, user and can  radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference byone or more the following measures:1. Reorient / Relocate the receiving antenna.2. Increase the separation between the equipment and receiver.3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected.4. Consult the dealer or an experienced radio/TV technician for helpCautionWarningInformation to UserFCC Rules

Navigation menu