User manual
Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital Input Connection Wiegand Input/Output Output Installation of Wall-mount Bracket Installation Reference Specification Electrical Specification FCC Rules Safety precautions Do not install the device in a place subject to direct sun light, humidity, dust or soot. Do not place the device next to heating equipments. Do not place a magnet near the product. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. It may cause a damage or a failure to the product. Be careful not to let liquid like water, drinks or chemicals leak inside the device. Clean the device often to remove dust on it. It may cause a failure. The list below is to keep userâs safety and prevent any loss. Please read safety precautions carefully before use. Safety precautions Do not drop the device. Do not disassemble, repair or alter the device. The warranty does net apply to any product damage cause by an arbitrary installation or repair. Do not let children touch the device without supervision. Do not use the device for any other purpose than specified. Do not damage the device. Contact your nearest dealer in case of a trouble or problem. The list above is to keep userâs safety and prevent any loss. Please read safety precautions carefully before use. Product components Basic components Xpass Wall mounting screws (2 ea) bracket Knife Blocks (2 ea) Extended Ethernet Cable Shrinkable Tubes Software CD The components shown above may differ depending on the installation environment. Optional accessories Secure I/O Plastic stand Extended bracket adaptor Names of each parts LED status *OJUJBMJ[BUJPOPGOFUXPSLTFUUJOH 8IFOZPVJOTUBMMUIF9QBTT PSGPSHFUUIFOFUXPSLTFUUJOHâTWBMVFPG9QBTT JOVTF DBOJOJUJBMUIFOFUXPSL TFUUJOHâTWBMVF 5$1*1BEESFTT 34TFUUJOH JOUIFTXJUDIPG9QBTTâT CBDLTJEFBTGPMMPXT Product Dimension (unit : mm) < Front View > < Side View > < Bracket > < Extended bracket > Cables and Connectors No 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Pin Name 485 GND Wiegand-GND 485 Wiegand-1 485 + Wiegand-0 Input-1 Relay Open Input-GND Relay Com Input-0 Relay Close TX+ (LAN) Power IN+ TX- (LAN) Power INRX+ (LAN) Power OUT+ RX- (LAN) Power OUTVB1 VB2 VB1 VB2 Color White (black string) Black Yellow (black string) White Blue (white string) Green Brown Gray (white string) Gray Green (white string) Purple Orange (black string) Pink Red Orange Black (white string) Blue Light Blue Yellow Black (white string) (SFFO black string) Brown (white string) (SFFO black string) Brown (white string) Cables and Connectors Cable Specification Pin 10 11 12 Relay Wiegand Switch 485 Pin Power Pin Name Color RLY NC RLY COM RLY NO WGD D0 WGD D1 WGD GND IN 0 IN 1 IN GND 485+ 485485 GND Orange (black string) Green (white string) Gray (white string) Green White Black Purple Brown Gray Blue (white string) Yellow (black string) White (black string) Pin Name POWER OUT POWER OUT + POWER IN POWER IN + áŞá˘ Black (white string) Light Blue Black (white string) Red LAN cable Pin LAN Pin Name Color RXRX+ TXTX+ VB1 VB1 VB2 VB2 Yellow Blue Orange Pink (SFFO black string) (SFFO black string) Brown (white string) Brown (white string) Ethernet extension cable Modular Jack (A) Connector (B) Pin Name Color TX+ Blue TX- Orange RX+ Black RX- Yellow VB1 Red VB1 Green VB2 Brown VB2 Gray Power Connection 1 Pin Pin Name Color 14 POWER IN+ Red 16 POWER IN- Black (white string) Recommended power supply 12V ¡ 10%, at least 500mA. Comply with standard IEC/EN 60950-1. To share the power with other devices, use a power supply with higher current ratings. Power Connection 2 Recommended power supply Please use the distance of LAN cable within 100m in case of POE power. LAN Connection LAN Connection (Direct connection with PC) RS485 Connection for Host Communication Pin Pin Name Color 485 GND White (black string) 485 - Yellow (black string) 485 + Blue (white string) RS485 Connection for Secure I/O Pin Pin Name Color 485 GND White (black string) 485 - Yellow (black string) 485 + Blue (white string) Max number of devices Maximum eight(8) devices (including Master) interworks in an RS485 loop. Relay Connection â Fail safe lock Pin Pin Name Color 10 RLY COM Green (white string) 12 RLY NC Orange (black string) Relay Connection â Fail secure lock Pin Pin Name Color RLY NO Gray (white string) 10 RLY COM Green (white string) Relay Connection - Automatic door Pin Pin Name Color RLY NO Gray (white string) 10 RLY COM Green (white string) Digital Input Connection (Alarm, Emergency S/W) Pin Pin Name Color IN 1 Brown IN GND Gray 11 IN 0 Purple Digital Input Connection (RTE, Door sensor) Pin Pin Name Color IN 1 Brown IN GND Gray 11 IN 0 Purple Wiegand Input/Output Wiegand Input Wiegand Output Pin Pin Name Color WGD GND Black WGD D1 White WGD D0 Green Pin Pin Name Color WGD GND Black WGD D1 White WGD D0 Green Output Pin Pin Name Color 10 RLY COM Green (white string) 12 RLY NC Orange (black string) 18 PWR OUT + Light Blue 20 PWR OUT - Black (white string) Caution : Max. 700mA is supplied using adapter for the external output. Be careful to satisfy the power capacity in use. Installation of Wall-mount Bracket Fix wall mount bracket on a wall using wall mounting screws Hook Xpass on the wall mount bracket Fix Xpass and wall mounting bracket using a wall mounting screw. Installation Reference 1 - Stand alone Installation Reference 2 â Standalone (Secure) Installation Reference 3 â Network Specification CPU Memory 32 bit Micro-processor User Capacity 8MB FLASH + 16MB SDRAM 13.56 MHz Mifare (XPM) 125 KHz EM Prox (XPE) 125 KHz HID Prox (XPH) 40000 user Log Capacity 50000 log RF Card Network interfaces TCP/IP, RS485 IP Rate IP 65 class Sound Multi-tone buzzer LED Multi-color LED RTC Lithium-ion rechargeable batteries Relay x 1 Tamper x 1 Switch input x 2 Wiegand x 1 12Vdc, POE I/O Power Operating Temperature Size Certificates -20 ~ 50â°C 45 x 130 x 27mm (W x H x D ) CE, FCC, KCC, IP65 Caution for RTC Battery It may be occurred the risk of explosion for improper replacement of battery. Please use the specified battery according to proper instruction. Electrical Specification Min. Typ. Max. Notes 10.8 12 13.2 Use regulated DC power adaptor only Power Voltage (V) Current (mA) 140 Switch Input VIH (V) TBD VIL (V) TBD Pull-up resistance (âł) 4.7k VOH (V) VOL (V) 0.8 Pull-up resistance (âł) 4.7k 0.3 30V DC 125V AC DC AC DC AC The input ports are pulled up with 4.7k resistors TTL/Wiegand Output The outputs ports are open drain type, pulled up with 4.7k resistors internally Relay Switching capacity (A) Switching power (resistive) 30W 37.5V Switching voltage (V) 110 125 FCC Rules Caution Warning Information to User Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the userâs authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interface, and (2) this device must accept any interface received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more the following measures: 1. Reorient / Relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2010:02:04 13:47:58+09:00 Modify Date : 2010:02:04 13:47:58+09:00 Metadata Date : 2010:02:04 13:47:56+09:00 Document ID : uuid:AA1591584811DF11B803C43C7DD12905 Instance ID : uuid:fdb13a27-5076-497f-9ba4-6104a60c5db6 Derived From Instance ID : uuid:fd5d9331-a0ab-4411-80d1-0877c6fc4369 Derived From Document ID : uuid:908a29b2-3703-4826-a597-5915fd4d35cf Format : application/postscript Creator : ?꾩?? Title : ?щ씪?대뱶 1 Page Count : 34 Author : ?꾩??EXIF Metadata provided by EXIF.tools