Swaive SWT1A Swaive Thermometer User Manual SWT1A UserMan 20150603

Swaive Corporation Swaive Thermometer SWT1A UserMan 20150603

(SWT1A) UserMan_20150603

Download: Swaive SWT1A Swaive Thermometer User Manual  SWT1A  UserMan 20150603
Mirror Download [FCC.gov]Swaive SWT1A Swaive Thermometer User Manual  SWT1A  UserMan 20150603
Document ID2634295
Application IDyAlwajEm43Gb35PbMqycRQ==
Document Description(SWT1A) UserMan_20150603
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize46.48kB (580966 bits)
Date Submitted2015-06-03 00:00:00
Date Available2015-06-04 00:00:00
Creation Date2015-06-03 15:55:03
Producing SoftwareAdobe Acrobat 8.0
Document Lastmod2015-06-03 15:55:03
Document Title(SWT1A) UserMan_20150603
Document CreatorAdobe Acrobat 8.0 Combine Files

• Do not use the thermometer outside
of the normal operating ambient
humidity of up to 95%RH.
• Do not use the thermometer when
the ear canal is wet, or when the
person is suffering from ear infection.
• Do not insert the probe into the ear
canal with excessive force.
• The use of this thermometer is
not intended as a substitute for
physician’s consultation.
• Earwax and obstructions will affect
the accuracy of the temperature
reading.
• Sleeping on your ear may cause the
ear temperature to rise.
• The thermometer is calibrated and
does not require re-calibration if used
in accordance to the instructions.
• The measured temperature may be
different for each side of the ear. It
is recommended to use the same
side ear to help ensure accurate
measurements.
• Body temperature will rise after a
shower or exercise.
• This thermometer is intended for
household use only.
Storage Requirements
• Do not expose to temperature
extremes below -20°C (-4°F ) or over
50°C (122°F), or excessive humidity
(above 95%RH).
• Do not expose to direct sunlight or
fire.
• Do not shock, vibrate, drop or step
on the thermometer.
• Do not allow any liquids into the
thermometer.
• Do not disassemble, repair or
remodel the thermometer.
• Keep out of reach of children.
• Clean the main body of the
thermometer with a dry soft cloth.
Please do not use abrasive cleaning
agents.
• Use only AA type batteries (but do
not use rechargeable batteries)
Please do not discard the batteries into
fire.
that the product is within the warranty
period) must be provided. This warranty
is invalid if the factory applied labels
have been altered or removed from the
product.
Limited Warranty
Specification
Swaive warrants this product against
any defects in material or workmanship
for a period of one (1) year from the
original date of purchase. The warranty
only applies when used for normal use
and does not cover cosmetic damage
or damage due to the acts of God,
accident, misuse, abuse, negligence,
commercial use or modification of or to
any part of the product. This warranty
excludes the battery and probe covers.
REPAIR OR REPLACEMENT AS
PROVIDED UNDER THIS WARRANTY
IS THE EXCLUSIVE REMEDY OF THE
CONSUMER. SWAIVE SHALL NOT
BE LIABLE FOR ANY INCIDENTAL
OR CONSEQUENTIAL DAMAGES
FOR BREACH OF ANY EXPRESS
OR IMPLIED WARRANTY ON THIS
PRODUCT, EXCEPT TO THE EXTENT
PROHIBITED BY LAW.
To obtain warranty service, please
contact Swaive Customer Support.
Proof of purchase (which is evidence
Manufactured By
Swaive Corporation
Suite A21, 1400 Coleman Avenue,
CA 95050, USA
Telephone Toll Free: +1 844 4SWAIVE
Email: support@swaive.com
Website: www.swaive.com
EN
Copyright
© SWAIVE Corporation. All rights
reserved. Manufactured for SWAIVE
Corporation. Made in Taiwan. The
Bluetooth® word mark and logos
are registered trademarks owned by
Bluetooth SIG, Inc. and any use of such
marks by SWAIVE Corporation is under
license. iPad, iPhone, and iPod touch
are trademarks of Apple Inc., registered
in the U.S. and other countries. Other
trademarks and trade names are those
of their respective owners.
Model
SWT1A infrared ear thermometer
Sensor type
Thermopile
Displayed temperature range
33°C~40°C (92.0°F~105°F)
Operating ambient temperature range
10°C~40°C (50°F ~104°F )
Operating ambient humidity range
0~95% RH
Accuracy
± 0.1°C, ±0.2°F
Battery type
Two AA batteries
Battery life
At least 5000 measurements (2 years)
Automatic Display Switch-off
10 secs after measurement has been
taken
Weight
34g (with battery)
Standard/Compliance
ASTM E1965-98
Bluetooth LE v4.0
FCC Part B
CE Medical Device
Class II
Thermometer
the world’s most intelligent ear thermometer
User Guide
SWT1A
Read and Save These
Instructions
Thank you for purchasing the infrared
Swaive SWT1A family ear thermometer.
Please read these instructions carefully
to ensure safe operation and accurate
temperature measurements.
Package Contents
• Swaive SWT1A thermometer
• Two AA batteries
• 20 hygienic covers
• Case
• User Guide
The Swaive family thermometer can be
used with or without a smart mobile
device. To view the list of smart mobile
devices and to download the latest
app, please visit www.swaive.com/
devices.
Understanding Body
Temperature
Normal body temperature is a range
and not a fixed value. Body temperature
fluctuates throughout the day and is
generally lower in the morning and
higher in the evening. Body temperature
is also lower as one ages. An infant
can have a higher normal temperature
than an adult. Additionally, temperature
taken at different parts of the body (oral,
axilla, rectum and ear) will have different
temperature ranges. Therefore, body
temperature from different parts of the
body should not be directly compared.
The normal temperature range for the
Swaive ear thermometer for different
ages is shown below.
Product Description
Probe (1)
Age
(years)
Range
(°C)
Range
(°F)
0-2
36.4-38.0
97.5-100.4
3-10
36.1-37.8
97.0-100.0
11-65
35.9-37.6
96.6-99.7
>65
35.8-37.5
96.4-99.5
The Swaive thermometer app can learn
each family member’s normal body
temperature range and compensate
for variations that may typically exist.
Use the Swaive app on yourself and
your family members to determine the
normal temperature range.
Why Use the Ear?
Human body temperature is controlled
and regulated by the hypothalamus in
the brain. The blood flowing through
the hypothalamus also flows through
the ear drum. The Swaive thermometer
uses infrared technology to measure
the energy emitted from the ear drum
and the surrounding tissue. This is
safely and accurately converted into
core body temperature.
Button (2)
Night-LED (3)
Display (4)
Battery Cover (5)
Using With a Smart Mobile
Device
1. Visit www.swaive.com/downloads
and
download
the
Swaive
thermometer app.
2. When the installation is complete,
open the Swaive thermometer app.
3. Open the battery cover (5) and
insert the batteries into the Swaive
thermometer. RDY will be displayed
on the Swaive thermometer display
(4). When the display is clear, the
thermometer is ready for use.
4. The Swaive thermometer will
automatically connect to the
Swaive thermometer app. The
Swaive thermometer app will
notify you when the connection is
complete. If the notification does
not appear, please go to the Swaive
thermometer app settings tab and
follow the instructions on how to
connect. Please note, Bluetooth
must be enabled on the smart
mobile device.
5. For night use, hold the button (2)
down for three seconds to turn the
night-LED (3) on. Repeat to turn the
night-LED (3) off. For day-time use,
ignore this step.
6. Place a new hygienic cover on the
probe (1).
7. Place the probe (1), with the hygienic
cover on, into the ear.
8. Press button (2) once. You will hear
a beep.
9. A second beep will sound when
the temperature has been taken.
The temperature reading will be
shown on the display (4) and will
be transmitted to the smart phone
automatically.
10. Swaive
thermometer
will
automatically go in to sleep mode
and is always ready. To take a new
reading, follow steps 5 to 9.
Using Without a Smart Mobile
Device
1. Open the battery cover (5) and
insert batteries in to the Swaive
thermometer. RDY will be displayed
on the Swaive thermometer display
(4). When the display is clear, the
thermometer is ready for use.
2. For night use, hold the button (2)
down for three seconds to turn the
night-LED (3) on. Repeat to turn the
night-LED (3) off. For day-time use,
ignore this step.
3. Place a new hygienic cover on the
probe (1).
4. Place the probe (1), with the hygienic
cover on, into the ear.
5. Press button (2) once. You will hear a
beep.
6. A second beep will sound when the
temperature has been taken. The
temperature will be shown on the display
(4). Please note, if a smart mobile device
is not connected, the reading will be
stored in the Swaive thermometer. The
next time the smart mobile device is
connected, all readings will be sent to the
smart mobile device.
7. Swaive thermometer will automatically go
in to sleep mode and is always ready. To
take a new reading, follow steps 2 to 6.
Correct Usage
1. Measurements should only be taken with
a probe cover. A new and clean probe
cover before every measurement.
2. To obtain the most accurate temperature,
the ear should be gently tugged allowing
a clear view of the ear drum (figure A). If
the ear is not tugged, then a incorrect
temperature reading could be taken
(figure B). Tugging the ear straightens
the ear canal providing a clear passage
to the ear drum. While tugging the ear, fit
the probe snugly into the ear canal.
3. For children under 1 year (older than 6
months), pull the ear straight back (figure
C). For children aged 1 year to adult, pull
the ear up and back (figure D).
36.8°C
34.6°C
Taking Safe & Accurate Readings
• Please use a new and clean hygienic
cover for every measurement.
• Do not use the thermometer outside of the
normal operating ambient temperature of
10°C (50°F) ~ 40°C (104°F).


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2015:06:03 15:55:03+08:00
Create Date                     : 2015:06:03 15:55:03+08:00
Metadata Date                   : 2015:06:03 15:55:03+08:00
Creator Tool                    : Adobe Acrobat 8.0 Combine Files
Format                          : application/pdf
Document ID                     : uuid:432ea840-9a99-43e7-9d93-a667210a0fd2
Instance ID                     : uuid:3ad66ea9-bced-4970-b8d3-8f46363821d8
Producer                        : Adobe Acrobat 8.0
Has XFA                         : No
Page Count                      : 3
Creator                         : Adobe Acrobat 8.0 Combine Files
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AEOA-SWT1A

Navigation menu