Speed Scrub 24 32 Service Manual Nobles Ss5 Walk Behind Floor Scrubber
2018-06-20
: Sweepscrub Nobles-Speed-Scrub-24-32-Ss5-Walk-Behind-Floor-Scrubber-Service-Manual nobles-speed-scrub-24-32-ss5-walk-behind-floor-scrubber-service-manual 2784 file product_file
Open the PDF directly: View PDF .
Page Count: 51
Download | |
Open PDF In Browser | View PDF |
® SPEED SCRUB ® AUTOMATIC SCRUBBER The Safe Scrubbing Alternativer Quick- Traint Controls SERVICE INFORMATION MANUAL 9002377 Rev. 01 (09-2006) www.nobles.com *9002377* A B FOR REPLACEMENT PARTS Identify machine model and serial number. 1. (A) Identify the machine model. 2. (B) Identify the machine serial number from the data label. Refer to the NOBLES Speed Scrub Parts Manual. NOTE: Only use NOBLES supplied or equivalent parts. Parts and supplies may be ordered online, by phone, by fax or by mail. Tennant Company PO Box 1452 Minneapolis, MN 55440 Phone: (800) 553--8033 or (763) 513--2850 www.nobles.com FaST--PAK is a US registered and unregistered trademark of Tennant Company. Specifications and parts are subject to change without notice. Copyright E 2006 TENNANT Company, Printed in U.S.A. ii Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub Service Information Manual Table of Contents page MACHINE INFORMATION Component Locator……………………….…...……………………………..……1 Machine Specifications………...…………………….……………………………5 MAINTENANCE SAFETY LABELS………………………..…………………………………………7 BATTERY INSTALLATION………………………………………………………… 8 SQUEEGEE REMOVAL & INSTALLATION…………………………………… 8 CIRCUIT BREAKERS & FUSES…………………………………………………9 CHARGING BATTERIES………………………..…………………………………9 Battery Charger Specifications…………………………….……………... 9 On-Board Battery Charger Settings……………………………………… 9 Using the On-Board Battery Charger………………………………………10 On-Board Battery Charger Error Codes…………………………………… 11 Using an Off-Board Battery Charger………………………………………11 ADJUSTING SCRUB HEAD BRUSHES…………………………………………12 Disk Brush Model………………...………………………………………. 12 Cylindrical Brush Model……………………………………..………………12 Adjusting an Uneven Brush Pattern…………………………………13 Adjusting a Tapered Brush Pattern…………………………………13 MACHINE MAINTENANCE……………………………………………..…………14 Daily Maintenance…………………………………………..………………14 Monthly Maintenance………………………………….……………………16 Battery Maintenance……………...………..……………………………… 17 Squeegee Blades……………………….…………………...………………17 Motor Maintenance……………………………………….…………………18 FaST System Maintenance……………………………………….………… 18 JACKING UP MACHINE……………………….……...…………………………… 19 TRANSPORTING MACHINE…………………….……………...………………… 19 STORING MACHINE………………………………………...…..…………………19 FaST System Freeze Protection……………..……………………...…… 19 RECOMMENDED STOCK ITEMS……………..……………….………………… 20 BASIC TROUBLESHOOTING……………………….……………………………21 ELECTRICAL Electrical Schematic…………………………...…..…………………..…………… 23 Wiring Harness Detail………………………...………………..…………………… 24 Control Board & BDI Details………………………………………………………30 Control Board & BDI Pin Charts…………………………………………………… 31 BDI Diagnostic Fault Indicators……………………………………………………32 Electrical Symbols & Terms…………………………...……………..……………33 Key OFF Power Distribution (Off-Board Charger Disconnected)………………34 Key OFF Power Distribution (Off-Board Charger Connected)…………………35 Key OFF Power Distribution (On-Board Charger Disconnected)………………36 Key OFF Power Distribution (On-Board Charger Connected)…………………37 Key ON Power Distribution………………….………….…………………………38 Propel Forward System…………………………...……………………………… 39 Propel Reverse System………………………………………………………….. 40 Scrub Brushes……………………...…………………………..…………………… 41 Vacuum Fan System…………………………..………………..………………..… 42 Conventional Solution Solenoid Valve & Hour Meter……………………………43 FaST Pump & Hour Meter…………………………………………………………44 Scrub Head Actuator LOWER (Extend)……………………………….…………45 Scrub Head Actuator RAISE (Retract)……………………………………………46 Wand Pump…………………………….……………………………………………47 Nobles Speed Scrub 9002377 REV.00 (08-06) iii Speed Scrub Service Information Manual ! BEFORE CONDUCTING TESTS: ! z Read and Follow ALL Safety Warnings and Precautions in Operator's Manual z Always use an ESD (Electrostatic Discharge) strap when working near the Control Board z Be cautious when working near Control Board – Battery voltage is always present, even with Key OFF z Always Disconnect Batteries when removing or replacing components DURING TESTS: z Call Technical Services if Diagnostic Time Exceeds One Hour with Unknown Cause or Course of Action iv Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub Component Locator (Page 1 of 4) 1 4 5 2 6 7 3 3 10 8 9 1. 2. 3. 4. 5. 6. Battery Meter (Battery Discharge Indicator) Reverse Trigger Start Triggers (Propel/Scrub) Brush Pressure Meter Control Console Height Adjustment Lever Speed Control Knob (Potentiometer) Nobles Speed Scrub 9002377 REV.00 (08-06) 11 7. 8. 9. 10. 11. Brush Pressure Switch Off--Aisle Wand on/off Switch (option) FaST System on/off Switch (option) Main Power on/off Key Switch Hour Meter 1 Speed Scrub Component Locator (Page 2 of 4) CONTROL BOARD AND CIRCUIT BREAKERS RECOVERY TANK INTERLOCK SWITCH VACUUM FAN MOTOR M3 FRONT FaST PUMP MOTOR M6 2 O FR BOTTOM VIEW N T FR O N T FRONT BOTTOM VIEW PROPEL MOTOR M4 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub Component Locator (Page 3 of 4) MOTOR M1 CYLINDRICAL SCRUB BRUSH MOTORS MOTOR M2 MOTOR M1 DISK SCRUB BRUSH MOTORS MOTOR M2 ACTUATOR SCRUB/TRANSPORT SWITCH ACTUATOR RAISE LIMIT SWITCH ACTUATOR LOWER LIMIT SWITCH SCRUB HEAD ACTUATOR M5 Nobles Speed Scrub 9002377 REV.00 (08-06) SCRUB HEAD ACTUATOR M5 3 Speed Scrub Component Locator (Page 4 of 4) ON-BOARD CHARGER VACUUM FAN SWITCH CHARGER INTERLOCK SWITCH (OFF-BOARD CHARGER) CONVENTIONAL SOLENOID VALVE CONTROL BOARD STANDOFF CIRCUIT BREAKERS BRUSH CONTACTOR CR1 CB1 CB2 25A CB3 25A CB4 25A 10A RELAYS CR2 100A FUSE F1 CR3 CR4 STANDOFF 4 CONTROL BOARD, FUSE, & CIRCUIT BREAKERS Nobles Speed Scrub 9002377 REV.00 (08-06) MACHINE SPECIFICATIONS MODEL LENGTH WIDTH Disk, Disk, Disk, Cylindrical, Cylindrical, 24 in / 600mm 28 in / 700mm 32 in / 800mm 26 in / 650mm 32 in / 800mm 53.4 in / 1,357 mm 55.5 in / 1,408 mm 58 in / 1,471 mm 55 in / 1,399 mm 55 in / 1,399 mm 25.4 in / 645 mm 29 in / 737 mm 33 in / 838 mm 28 in / 711 mm 34 in / 864 mm 44 in / 1120 mm HEIGHT MINIMUM AISLE TURN 53 in / 1,346 mm 59 in / 1,499 mm 64 in / 1,626 mm 62 in / 1,575 mm 64.5 in / 1,638 mm WEIGHT 293 lb / 133 kg 320 lb / 145 kg 332 lb / 151 kg 332 lb / 151 kg 342 lb / 155 kg WEIGHT WITH BATTERIES 569 lb / 258 kg 593 lb / 269 kg 606 lb / 275 kg 606 lb / 275 kg 615 lb / 279 kg RECOVERY TANK CAPACITY 27 gal / 105 L SOLUTION TANK CAPACITY 22.5 gal / 85 L Transaxle, 24 V, .25 hp / .19 kW DRIVE SYSTEM Cleaning: 220 ft / 67 m per min Transporting: 235 ft / 72 m per min TRAVEL SPEED, MAXIMUM PRODUCTIVITY RATE Theoretical 26,400 ft2 / 2,450 m2 h 30,800 ft2 / 2,860 m2 h 35,200 ft2 / 3,270 m2 h 28,600 ft2 / 2,660 m2 h 35,200 ft2 / 3,270 m2 h PRODUCTIVITY RATE Estimated Actual 17,875 ft2 / 1,660 m2 h 20,800 ft2 / 1,930 m2 h 24,000 ft2 / 2,230 m2 h 19,200 ft2 / 1,785 m2 h 24,000 ft2 / 2,230 m2 h CLEANING PATH WIDTH 24 in / 600 mm 28 in / 700 mm 32 in / 800 mm 26 in / 650 mm 32 in / 800 mm BRUSH DIAMETER 11.9 in / 302 mm 13.9 in / 353 mm 15.9 in / 404 mm 5.9 in / 151 mm 5.9 in / 151 mm .6 gpm / .6 gpm / 2.27 L/min 2.27 L/min up to 120 lb / 54 kg BRUSH PRESSURE SOLUTION FLOW RATE SQUEEGEE WIDTH .5 gpm / 1.89 L/min .50 gpm / 1.89 L/min 35.7 in / 908 mm standard 41.3 in / 1,051 mm standard 46.6 in / 1,185 mm standard 41.3 in / 1,051 mm standard 46.6 in / 1,185 mm standard 31.5 in / 800 mm narrow aisle 35.7 in / 908 mm narrow aisle 41.3 in / 1,051 mm narrow aisle 35.7 in / 908 mm narrow aisle 41.3 in / 1,051 mm narrow aisle BRUSH MOTOR Qty 2, .75 hp / .55 kW, 220 rpm, 24 V, 29 A .85 hp / .63 kW, 640 W, 3--stage 5.7, 24 V, 26 A VACUUM MOTOR 62 in / 55 mm -- 69 ft3 / 32.4 L3 /m WATER LIFT -- AIR FLOW Qty 4, 6 V BATTERIES BATTERY CAPACITY Qty 2, .63 hp / .47 kW, 1500 rpm, 24 V, 23 A WET (lead Acid) = 235 Ah @ 20 h rate Sealed (Gel)= 200 Ah @ 20 h rate RUN TIME PER CHARGE* WET = Up to 5.0 hours ON--BOARD CHARGER 120 VAC, 10 A, 50/60 Hz, 24 VDC, 20 A output 50 A nominal TOTAL POWER CONSUMPTION 24 VDC VOLTAGE DC IPX3 PROTECTION GRADE DECIBEL RATING AT OPERATOR’S EAR, INDOORS.** VIBRATION AT CONTROLS Gel = Up to 4.0 hours 67dBA 68dBA <.39 ft/s2 / <.1188 m/s2 ACCELERATION RATE ON OPERATOR -- MAX. GRADE LEVEL, MAX. <.34 ft/s2 / <.103 m/s2 .56 ft / .179 m /s2 Scrubbing 5% (3°), Transporting 8% (5°) * Run times are based on Continuous Scrubbing Run Times. ** Sound levels (ISO 11201) as recommended by the American Association of Cleaning Equipment Manufacturers (AACEM) and OSHA. Nobles Speed Scrub 9002377 REV.00 (08-06) Nobles Speed Scrub (08--06) 5 FaST SYSTEM Disk, Disk, Disk, Cylindrical, Cylindrical, 24 in / 600mm 28 in / 700mm 32 in / 800mm 26 in / 650mm 32 in / 800mm 20,075ft2 / 1,865m2 /h PRODUCTIVITY RATE Estimated Actual 22,750ft2 / 2115m2 /h 26,250ft2 / 2440m2 /h 21,000ft2 / 1950m2 /h 26,250ft2 / 2440m2 /h SOLUTION PUMP 24 Volt DC, 3.5 A, 1.5 gpm / 5.6 L/min open flow, 60 psi / 4.13 Bar bypass setting SOLUTION FLOW RATE 0.15 gpm / 0.57 L/min CONCENTRATE FLOW RATE 0.0193oz / 0.57CC /min. 0.22 gpm / 0.83 L/min. 0.028oz / 0.83CC /min. CONCENTRATE TO WATER DILUTION RATIO 0.15 gpm / 0.57 L/min. 0.22 gpm / 0.83 L/min. 0.0193oz / 0.57CC /min. 0.028oz / 0.83CC /min. 1:1000 MACHINE DIMENSIONS B 44 in 1,120 mm A Models: A= B= C= 6 C 24 in / 600 mm Disk 28 in / 700 mm Disk 32 in / 800 mm Disk 26 in / 650 mm Cylindrical 28 in / 800 mm Cylindrical 53.4 in / 1,357 mm 25.4 in / 645 mm 35.7 in / 908 mm 55.5 in / 1,408 mm 29 in / 737 mm 41.3 in / 1,051 mm 58 in / 1,471 mm 33 in / 838 mm 46.6 in / 1,185 mm 55 in / 1,399 mm 28 in / 711 mm 41.3 in / 1,051 mm 55 in / 1,399 mm 34 in / 864 mm 46.6 in / 1,185 mm Nobles Speed Scrub 9002377 REV.00 (08-06) Commonly Used Electrical Symbols & Terms NOTE: The term “NORMALLY” refers to the components’ “at rest” or “de-energized” position - + Wires Connected Together Wires Not Connected Together Normally Open Normally Open Double Throw Switch Momentary Switch Relay Coil (Part 1 of Relay) Indicates Movement from Normal Position Battery Circuit Breaker Fuse Normally Open Normally Closed Normally Open Normally Closed Limit Switch Push-Button Switch Push-Button Switch Limit Switch Normally Open CR1 Plug-in Connection Diode Normally Closed CR1 CR1 Relay Contacts (Part 2 of Relay) Indicates Component in Position Other than Normal Solenoid (Valve or Actuator) Indicates Component is Energized Potentiometer Motor Assembly i ! Information Warning! Terms & Abbreviations AC – Alternating Current BDI – Battery Discharge Indicator CB – Circuit Breaker CR – Relay (Contact Type) LED – Light Emitting Diode M – Motor PWM (Pulse Width Modulation) – A method of using controlled on/off times to regulate voltage and current to an electrical device Standoff – A common connecting point for multiple wires Example of Wiring Numbers & Colors: Wiring Color Codes (Unless otherwise marked) Right Most Digit of Wire Number 0 1 Color of Wire Tan Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White Nobles Speed Scrub 9002377 REV.00 (08-06) 1 RED 25 7 13 BLK 7 Speed Scrub – Maintenance (Page 1 of 16) SAFETY LABELS The safety labels appear on the machine in the locations indicated. Replace labels if they are missing or become damaged or illegible. WARNING LABEL -Located on recovery tank cover. BATTERY CHARGE LABEL -Located on bottom side of recovery tank. WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. SPINNING BRUSH LABEL Located on scrub head WARNING: Spinning Brush. Keep Hands Away. Turn Off Power Before Working On Machine. 8 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Maintenance (Page 2 of 16) BATTERY INSTALLATION SQUEEGEE REMOVAL & INSTALLATION WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Hood Open When Charging. REMOVING SQUEEGEE ASSEMBLY FOR SAFETY: When installing batteries, wear protective gloves and eye protection. Avoid contact with battery acid. 1. Park the machine on a level surface, remove the key and set the parking brake if equipped. 2. Lift the squeegee lift lever to the upward position (Figure 3). Battery Specifications: Four 6 volt, 235A/20h deep cycle batteries. Maximum battery dimensions: 7.5 in / 190 mm W x 10.8 in / 275 mm L x 11.2 in / 284 mm H. 1. Park the machine on a level surface, remove the key and set the parking brake, if equipped. 2. Carefully install the batteries into the battery compartment tray (Figure 1). Arrange the battery posts as shown (Figure 2). FIG. 3 3. Remove the vacuum hose from the squeegee assembly. Note loop and clip on hose (Figure 4). FIG. 1 3. Connect the battery cables to the battery posts as shown (Figure 2), RED TO POSITIVE (+) and BLACK TO NEGATIVE (--). FIG. 4 4. Loosen the knobs and slide squeegee assembly away from pivot bracket (Figure 5). 235 A/20Ah BLACK RED Machine Front FIG. 2 Nobles Speed Scrub 9002377 REV.00 (08-06) 5. FIG.5 F Installation is in reverse order of removal. 9 Speed Scrub – Maintenance (Page 3 of 16) 6. Check the squeegee blades for proper deflection. The blades should deflect as shown (Figure 6). CHARGING BATTERIES ATTENTION: To prolong the life of the batteries only recharge the batteries if the machine was used for a total of 30 minutes or more. Do not leave batteries discharged for lengthy periods. WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. FOR SAFETY: When servicing batteries, wear protective gloves and eye protection when handling batteries and battery cables. Avoid contact with battery acid. 12.5 mm ½” FIG. 6 7. To adjust the blade deflection, place the squeegee assembly on a level surface and adjust the casters as shown (Figure 7). 2 mm 1/16” BATTERY CHARGER SPECIFICATIONS S CHARGER TYPE: -- FOR SEALED (Gel) BATTERIES -- FOR WET (Lead acid) BATTERIES S S S S OUTPUT VOLTAGE - 24 VOLTS OUTPUT CURRENT - 20 AMPS AUTOMATIC SHUTOFF CIRCUIT FOR DEEP CYCLE BATTERY CHARGING ON--BOARD BATTERY CHARGER SETTINGS FIG. 7 CIRCUIT BREAKERS AND FUSES FIG. 7 The machine is equipped with four resettable circuit breakers and four fuses to protect the machine from damage. If a breaker should trip, determine the cause, allow the motor to cool then manually reset the circuit breaker button. The circuit breaker panel is located near the battery compartment (Figure 29). The fuses are located inside the circuit breaker box. When replacing a fuse never substitute a higher Amp rated fuse than specified. If your machine is equipped with the on--board charger, the charger settings must be set for your battery type before charging. Failure to properly set will result in battery damage. To determine your battery type, see battery label. Contact your battery supplier if not specified. To verify the setting of the charger, connect the charger cord into an electrical receptacle. The charger will display a sequence of codes. One of the codes will either read “GEL” or “Acd” (Figure 41). GEL = Set for sealed/maintenance free batteries Acd = Set for wet/lead acid batteries CIRCUIT BREAKERS: 10 A -- Main (A) 25 A -- Vacuum motor (B) 25 A -- Left brush motor (C) 25 A -- Right brush motor (D) FUSES: 100 A -- Main 30 A -- Propel motor 7.5 A -- FaST system 7.5 A -- Off--aisle wand pump (located in control console) 10 FIG. 41 Nobles Speed Scrub 9002377 REV.00 (08-06) Nobles Speed Scrub (08--06) Speed Scrub – Maintenance (Page 4 of 16) To change the setting, unplug the charger, peel up the corner of the display label and set the switches accordingly (Fig. 42). The charger cord must be unplugged when resetting. NOTE: The machine will not operate when charging. FIG. 44 SEALED “GEL” BATTERY WET “Acd” BATTERY FIG. 42 USING THE ON--BOARD BATTERY CHARGER IMPORTANT: Before charging, make sure that the charger setting is properly set for your battery type (See ON--BOARD CHARGER SETTINGS). 1. Transport the machine to a well--ventilated area. 6. The charger will display a sequence of codes once the cord is connected (Figure 45). Three--digits + the following code: A = Charging current U = Battery voltage h = Charging time C = Charging ampere--hours [Ah] E = Energy used [Kwh] “GEL” or “Acd” = Battery type the charger is currently set for. Before charging make sure your battery type matches the display: GEL=Sealed, Acd=Wet (lead acid). To change setting, see ON--BOARD CHARGER SETTINGS. Press the arrow button to review the codes. 2. Park the machine on a flat, dry surface. Turn the key off and set the parking brake, if equipped. 3. If charging wet (lead acid) batteries check the fluid level before charging (See BATTERY MAINTENANCE). 4. Prop up the recovery tank for ventilation (Figure 43). FIG. 45 7. Once the charging cycle begins, the indicator lights will progress from red, yellow to green. When the green indicator light comes on, the charging cycle is done. Unplug the charger cord. FIG. 43 If the charger detects a problem, the charger will display an error code (See ON--BOARD BATTERY CHARGER ERROR CODES). 5. Connect the charger’s AC power supply cord into a properly grounded receptacle (Figure 44). Nobles Speed Scrub 9002377 REV.00 (08-06) Nobles Speed Scrub (08--06) 11 Speed Scrub – Maintenance (Page 5 of 16) ON--BOARD BATTERY CHARGER ERROR CODES DISPLAY CODE FAULT SOLUTION bat Loose or damaged battery cable Check battery cable connections. Battery exceeded maximum voltage level. No action necessary. E01 Exceeded maximum battery voltage allowed. No action necessary. E02 Safety thermostat exceeded maximum internal Check if the charger vents are obstructed. temperature. E03 Exceeded maximum time for charging phase leaving the batteries undercharged due to a sulfated or faulty battery. Repeat the charging cycle and if the error code E03 reappears check battery or replace it. SCt Safety timer exceeded maximum charging time. Interrupts charging cycle. Replace battery. Srt Possible internal short circuit. Contact Tennant Service 1-800-553-8033 USING AN OFF--BOARD BATTERY CHARGER 1. Transport the machine to a well--ventilated area. 2. Park the machine on a flat, dry surface. Turn the key off and set the parking brake, if equipped. 3. If charging wet (lead acid) batteries, check the fluid level before charging (See BATTERY MAINTENANCE). 4. Prop up the recovery tank for ventilation (Figure 46). FIG. 47 7. The supplied charger will automatically begin charging and shut off when fully charged. NOTE: The machine will not operate when charging. ATTENTION: Do not disconnect the charger’s DC cord from the machine’s receptacle when the charger is operating. Arcing may result. If the charger must be interrupted during charging, disconnect the AC power supply cord first. FIG. 46 5. Connect the charger’s AC power supply cord into a properly grounded receptacle. 6. Connect the charger’s DC cord into the machine’s battery receptacle (Figure 47). 12 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Maintenance (Page 6 of 16) ADJUSTING SCRUB HEAD BRUSHES CYLINDRICAL BRUSH MODEL To ensure optimum scrubbing performance periodically check the scrub head for proper adjustment. After installing a new set of cylindrical brushes check the brush pattern to ensure proper brush adjustment. Brushes that are not properly adjusted will result in premature wear and poor scrubbing performance (Figure 50). FOR SAFETY: Before adjusting scrub head, stop machine on level surface, remove key and set parking brake if equipped. CORRECT BRUSH PATTERN Even Pattern DISK MODEL Tools required: Measuring device, 1--1/16 in / 27 mm wrench and 15/16 in / 24mm wrench Uneven Pattern INCORRECT BRUSH PATTERNS Tapered Pattern 1. With brushes installed, lower the scrub head and apply medium brush pressure. 2. Turn machine off and remove key. 3. From the center front and back of scrub head, measure the distance from the top edge of scrub head to the floor (Figure 48). FIG. 50 To Inspect the Brush Pattern: 1. Position the machine on a dry dusty floor or apply a powdered substance, such as chalk. 2. Disconnect the drive motor wire connector to keep machine from moving forward (Figure 51). FIG. 48 4. If scrub head is not level, loosen the lock nut and turn the scrub head leveling screw to level. Tighten down the lock nut once head is level (Figure 49). FIG. 51 3. Lower the scrub head to the floor and apply maximum brush pressure. 4. Shut off the solution flow. Lock Nut FIG. 49 5. Pull the triggers to create a brush pattern on the floor. 6. Raise the scrub head and pull the machine away. 7. Observe the brush pattern on floor. If the brush pattern is uneven or tapered, adjustment is required. 8. Reconnect drive motor wire. Nobles Speed Scrub 9002377 REV.00 (08-06) 13 Speed Scrub – Maintenance (Page 7 of 16) To Adjust an Uneven Brush Pattern: To Adjust a Tapered Brush Pattern: Tools required: Measuring device, 1--1/16 in / 27 mm wrench and 15/16 in / 24mm wrench Tools required: 3/8 in / 10mm wrench and 6mm hex wrench 1. Measure the distance from the front edge of the scrub head to the floor and from the back edge of the scrub head to the floor (Figure 52). The measurements should be the same. 1. Raise the scrub head off floor and remove key. 2. Remove the idler plate from the brush (Figure 54). FIG. 54 FIG. 52 2. To level the scrub head, loosen the lock nut and turn the leveling screw clockwise to lower the rear of the scrub head or counter--clockwise to lower the front (Figure 53). 3. Hold the brush plug shaft with a wrench and loosen the 6mm hex screw (Figure 55). FIG. 55 FIG. 53 4. To lower the brush end, turn the shaft clockwise for the front brush and counter--clockwise for the rear brush. Retighten hex screw (Figure 56). 3. Recheck brush pattern. NOTE: Replace brush when bristles are worn to 5/8 in / 15 mm. FIG. 56 5. Recheck brush pattern. NOTE: Replace brushes when bristles are worn to 5/8 in / 15 mm. 14 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Maintenance (Page 8 of 16) 4. Drain the solution tank (Figure 60). MACHINE MAINTENANCE To keep the machine in good working condition, it’s important that the following maintenance procedures are performed on a routine basis. WARNING: Electrical Hazard. Disconnect Battery Cables Before Servicing Machine. DAILY MAINTENANCE (After Every Use) 1. Drain the recovery tank (Figure 57). FIG. 60 5. Rotate pad or replace when worn (Figure 61). FIG. 57 2. Rinse out the recovery tank (Figure 58). Disk Model FIG. 61 6. Empty and rinse out the debris trough (Figure 62). FIG. 58 3. Remove the recovery tank float shut--off screen and clean (Figure 59). Cylindrical Brush Model FIG. 62 7. Inspect the cylindrical brushes for wear. Rotate brushes from front--to--rear every 50 hours (Figure 63). Replace when worn to a length of 5/8 in / 15 mm. FIG. 59 Nobles Speed Scrub 9002377 REV.00 (08-06) 15 Speed Scrub – Maintenance (Page 9 of 16) 15mm (5/8”) Cylindrical Brush Model FIG. 66 FIG. 63 8. Remove debris buildup from the underside of the cylindrical brush scrub head, including the idler plates and drive hubs (Figure 64). 11. Clean the machine with an all purpose cleaner and damp cloth (Figure 67). FOR SAFETY: When cleaning machine, do not power spray or hose off machine. Electrical malfunction may occur. Cylindrical Brush Model FIG. 64 9. Wipe the squeegee blades clean (Figure 65). Store the squeegee assembly in the raised position to prevent blade damage. FIG. 65 10. Check the condition of the squeegee blade wiping edge (Figure 66). Rotate blade if worn (See SQUEEGEE BLADES). 16 FIG. 67 12. Inspect the condition of the scrub head skirt, replace if worn or damaged (Figure 68). Disk Model Cylindrical Brush Model FIG. 68 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Maintenance (Page 10 of 16) 13. FaST Model: Connect the FaST--PAK supply hose to the storage plug when not in use (Figure 69). Remove any dried concentrate from the hose connector by soaking it in warm water. 2. Check the cylindrical brush belt tension every 100 hours (Figure 72). Belt tension should flex 0.1 in / 3mm at midpoint, with 2.5--2.7 lb / 1.13--1.22 kg force. WARNING: Electrical Hazard. Disconnect Battery Cables Before Servicing Machine. FIG. 69 14. Clean wet/lead acid batteries to prevent corrosion and check for loose battery cable connections (See BATTERY MAINTENANCE). 15. Recharge the batteries (Figure 70) after a total of 30 minutes of use or more. FIG. 70 MONTHLY MAINTENANCE 1. Remove the solution tank filter from underneath the machine and rinse out the screen (Figure 71). Make sure the solution tank is empty before removing filter. Cylindrical Brush Model FIG. 72 3. Inspect and clean the recovery tank cover seal (Figure 73). Replace if damaged. FIG. 73 4. Lubricate all pivot points and rollers with a water resistant grease. 5. Lubricate the casters with a water resistant grease (Figure 74). FIG. 74 FIG. 71 Nobles Speed Scrub 9002377 REV.00 (08-06) 6. Clean the parking brake clamp with a cleaning solvent. 7. Check the machine for loose nuts and bolts. Nobles Speed Scrub (08--06) 17 Speed Scrub – Maintenance (Page 11 of 16) 8. Check the machine for leaks. BATTERY MAINTENANCE (Wet/lead acid batteries) 1. Check battery fluid level frequently to prevent battery damage. The fluid should be at the level shown (Figure 75). Add distilled water if low. DO NOT OVERFILL, the fluid may expand and overflow when charging. SQUEEGEE BLADES When the blades become worn, simply rotate the blades end-for-end or top-to-bottom to a new wiping edge. Replace blades when all edges are worn. The front blades on the 28 in / 700 mm and 32 in / 800mm squeegee assemblies have 12/14 slots on one edge and 6 slots on the opposite edge (Figure 77). If making sharp turns with the cylindrical brush models use the 12/14 slotted edge for maximum water pickup. 6 Slots on one edge 12/14 Slots on opposite edge CORRECT BATTERY FLUID LEVEL: Before Charging After Charging FIG. 77 Replacing Squeegee Blades: 1. Loosen the band clamp and remove the band from the squeegee assembly (Figure 78). FIG. 75 WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. 2. Clean the batteries to prevent battery corrosion. Use a scrub brush with a mixture of baking soda and water (Figure 76). FIG. 78 FOR SAFETY: When cleaning batteries, wear protective gloves and eye protection. Avoid contact with battery acid. FIG. 76 18 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Maintenance (Page 12 of 16) 2. Replace or rotate the rear blade to a new wiping edge and replace band (Figure 79). FaST SYSTEM MAINTENANCE Every 1000 hours replace the orifice plate and filter screen located inside the detergent injector assembly. 1. To access the detergent injector assembly, lower the scrub head and remove the front shroud (Figure 81) FIG. 79 3. To change the front blade, remove the band and loosen the four knobs. Replace or rotate the front blade to a new wiping edge (Figure 80) FIG. 81 2. Remove the injector assembly from clamps (Figure 82). FIG. 80 MOTOR MAINTENANCE Contact an Authorized Tennant Service Center for carbon brush replacement. Carbon Brush Replacement Hours Drive Transaxle Motor Vacuum Motor FIG. 82 3 Unthread the black plastic filter housing and replace the orifice plate and filter (Figure 83). 750 Disk Brush Motors Cylindrical Brush Motors 1000 WARNING: Electrical Hazard. Disconnect Battery Cables Before Servicing Machine. FIG. 83 Nobles Speed Scrub 9002377 REV.00 (08-06) Nobles Speed Scrub (08--06) 19 Speed Scrub – Maintenance (Page 13 of 16) JACKING UP MACHINE Use the designated locations to jack up the machine for service (Figure 84). Empty the recovery and solution tank and position the machine on a level before jacking. FOR SAFETY: When servicing machine, jack machine up at designated locations only. Use jack or hoist that will support machine weight. FIG. 85 STORING MACHINE 1. Charge the batteries before storing machine to prolong the life of the batteries. 2. Drain and rinse the tanks thoroughly. FIG. 84 TRANSPORTING MACHINE When transporting the machine by trailer or truck, be certain to follow the transporting procedure below: 1. Drain machine tanks. 2. Load the machine using a ramp that can support the machine weight and person loading it. The maximum ramp incline should not exceed 11° at a ramp length of 3.7m (12 ft). 3. Position the front of machine up against the front of the trailer or truck. Lower the scrub head and squeegee. 4. Set the parking brake, if equipped, and place a block behind each wheel to prevent the machine from rolling. 3. Store the machine in a dry area with the squeegee and scrub head in the up position. 4. Open the recovery tank cover to promote air circulation. ATTENTION: Do not expose machine to rain, store indoors. 5. If storing machine in freezing temperatures, make sure to drain machine of all water. For models equipped with the FaST System, follow the FaST SYSTEM FREEZE PROTECTION procedure below. FaST SYSTEM FREEZE PROTECTION Valve Coupling #1006205 and 6 in / 15 cm Hose #63182 are required (Purchased separately). 1. Remove the FaST--PAK carton and connect the valve coupling and 15 cm hose (purchased parts) to the supply hose (Figure 86). 5. Secure with tie--down straps as shown (Figure 85). It may be necessary to install tie-down brackets to trailer or truck. FOR SAFETY: When loading/unloading machine onto/off truck or trailer, use a ramp that can support the machine weight and person loading it, do not exceed a 11° ramp incline at a ramp length of 3.7m (12 ft), use tie--down straps to secure machine and block machine wheels. FIG. 86 20 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Maintenance (Page 14 of 16) 2. Disconnect the opposite end of the supply hose from the injector assembly and drain the supply hose (Figure 87). To access the injector assembly remove the front shroud. 7. To drain the anti--freeze, repeat the draining process above and reconnect the supply hose to the FaST--PAK carton. RECOMMENDED STOCK ITEMS Refer to the Parts List Manual for recommended stock items. Stock Items are clearly identified with a bullet preceding the parts description. See example below: FIG. 87 3. Reconnect the supply hose to injector assembly and pour a recreational vehicle (RV) anti--freeze into the supply hose until full (Figure 88). FIG. 88 4. Operate the FaST system as normal until the foaming stops. This step could take anywhere from 5--10 minutes. 5. Remove the valve coupling and connect the storage plug (Figure 89). FIG. 89 6. Drain the recovery and solution tanks and store machine. Nobles Speed Scrub 9002377 REV.00 (08-06) Nobles Speed Scrub (08--06) 21 Speed Scrub – Maintenance (Page 15 of 16) TROUBLESHOOTING PROBLEM CAUSE SOLUTION Machine will not operate Discharged batteries Charge batteries Emergency--stop button activated Turn button clockwise to reset Faulty battery(s) Replace battery(s) Loose battery cable Tighten loose cable Tripped main circuit breaker Reset 10A main circuit breaker Main fuse blown Replace 100A main fuse Faulty key switch Contact Service Center Machine fault detected. See Battery Meter LED Fault Codes Plug not connected to power supply Check plug connection Faulty charger fuse Replace charger fuse Faulty power supply cord Replace cord Error detected. See On--board Battery Charger Error Codes Scrub head is raised off floor Lower scrub head Battery meter lockout activated Recharge batteries Discharged batteries Charge batteries Tripped brush motor circuit breaker Reset 25A circuit breaker button Faulty scrub head (up/down) switch Contact Service Center Faulty trigger switch(es) Contact Service Center Faulty brush motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Broken or loose belt (cylindrical brush model) Replace or tighten belt Faulty relay switch Contact Service Center Parking brake is set Release parking brake lever Machine fault detected See Battery Meter LED Fault Codes Propel motor fuse blown Replace 30A fuse Faulty transaxle motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Exceeded maximum incline Avoid steep inclines and reset key Squeegee is raised off floor Lower squeegee Discharged batteries Charge batteries Tripped vacuum motor circuit breaker Reset 25A circuit breaker button Faulty vacuum motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Solution tank is empty Fill solution tank Clogged solution tank filter Clean solution tank filter Discharged batteries Charge batteries Clogged solution valve Remove valve and clean Solution flow control knob set too low Adjust solution control flow knob Loose screw on control knob Calibrate knob and retighten screw. On--board battery charger will not operate Brush motor(s) will not operate Machine will not propel Vacuum motor will not operate Little or no solution flow 22 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Maintenance (Page 16 of 16) TROUBLESHOOTING - Continued PROBLEM CAUSE SOLUTION Poor water pickup Recovery tank is full or excessive foam buildup Drain recovery tank Loose drain hose cap Tighten cap Clogged float shut--off screen located in recovery tank Clean screen Clogged squeegee assembly Clean squeegee assembly Worn squeegee blades Replace or rotate squeegee blades Incorrect Squeegee blade deflection Adjust Squeegee blade height Loose vacuum hose connections Secure hose connections Clogged vacuum hose Remove clogged debris Damaged vacuum hose Replace vacuum hose Recovery tank cover not in place Properly position cover Damaged recovery tank cover seal Replace seal Faulty vacuum motor Contact Service Center Low battery charge Recharge batteries Debris caught in brush Remove debris Worn brushes/pads Replace brushes/pads Incorrect brush pressure setting Adjust pressure setting Wrong brush/pad type. Use correct brush/pad Batteries not fully charged Fully recharge batteries Defective batteries Replace battery Batteries need maintenance See BATTERY MAINTENANCE Faulty battery charger Repair or replace battery charger FaST system switch is not turned on Turn on FaST system switch FaST--PAK supply hose not connected Connect supply hose Clogged FaST--PAK supply hose or connectors Soak in warm water to unclog Empty FaST--PAK carton Replace FaST--PAK carton Kink in FaST--PAK supply hose Undo hose kink Clogged FaST solution system Contact Service Center Faulty FaST system on/off switch Contact Service Center Faulty pump Contact Service Center Clogged solution tank filter Drain solution tank. Remove solution tank filter, clean and reinstall Clogged detergent orifice/filter screen Replace orifice/filter screen (See FaST SYSTEM MAINTENANCE) Clogged FaST solution inlet filter Contact Service Center FaST Pump fuse blown Replace 7.5A fuse Poor scrubbing performance Reduced run time FaST Model: FaST System does not operate or operate correctly Nobles Speed Scrub 9002377 REV.00 (08-06) Nobles Speed Scrub (08--06) 23 Speed Scrub – Electrical Schematic 24 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Wiring Harness Detail MAIN HARNESS C CONTINUED B CONTINUED A CONTINUED (Page 1 of 6) Nobles Speed Scrub 9002377 REV.00 (08-06) 25 Speed Scrub – Wiring Harness Detail MAIN HARNESS C (Page 2 of 6) 26 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Wiring Harness Detail Nobles Speed Scrub 9002377 REV.00 (08-06) B A MAIN HARNESS D CONTINUED E CONTINUED (Page 3 of 6) 27 Speed Scrub – Wiring Harness Detail 28 D MAIN HARNESS E (Page 4 of 6) Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Wiring Harness Detail CHASSIS HARNESS (Page 5 of 6) Nobles Speed Scrub 9002377 REV.00 (08-06) 29 Speed Scrub – Wiring Harness Detail FaST HARNESS (Page 6 of 6) 30 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub –Control Board & BDI Details CONTROL BOARD + - 1 2 4 3 2 1 2 1 BATTERY CONNECTIONS PROPEL MOTOR CONNECTIONS SCRUB OUTPUT CONNECTIONS PROGRAMMING CONNECTIONS 14 13 12 11 10 9 8 7 2 1 6 5 4 3 CONTROL CONNECTIONS 2 4 1 3 BATTERY DISCHARGE INDICATOR (VIEWED FROM REAR) Nobles Speed Scrub 9002377 REV.00 (08-06) 31 Speed Scrub –Control Board & BDI Pin Charts CONTROL BOARD CONNECTIONS Name Pin # Wire # Color Active Voltage Inactive Voltage Input/ Output Notes Function/Component Controlled Battery Connections + 22 brown battery (+) x input x Battery positive power supply - 13A black battery (-) x input x Battery negative power supply Propel Motor Connections 1 84 yellow 0v to 24v 0v output 2 19 white 0v to 24v 0v output Scrub Output Connections 1 25 green battery (+) battery (+) output 2 27 purple battery (-) open output see notes 1 x x x x x x 2 x x x x x x 3 x x x x x x 4 x x x x x x 1 3 orange input x Throttle signal input 2 32 brown 5v x output x Throttle 5v reference signal 3 29 white battery (-) open output CR2 4 x x x x x x 5 74 yellow battery (+) open input x Key switch input 6 48 gray battery (-) 2.5v input x Normal mode: wire 48 NOT connected to Low battery voltage lockout level 13H (20.7v lockout for WET batteries) select Special mode: wire 48 connected to 13H (22.4v lockout for Europe) 7 54 yellow output x Battery (+) supply for input switches 8 5 green 0v x output x Throttle 0v reference signal 9 x x x x x x 9 white output BDI 11 x x x x x x 12 x x x x x x 13 13G black battery (-) x output see notes 14 11 pink 0v 2.5v input x Programming Connections Control Connections 10 see notes battery (+) battery (+) see notes M4 Propel motor power supply connections Scrub functions power supply Forward=4v to 24v, Reverse=0v Reverse=1.5v to 12v, Forward=0v Controls CR1 (brush contactor), solution valve, CR4 (FaST relay), & hour meter Used only for programming the control board Reverse=0v to 2.25v; Fwd=2.75v to 5v; Neutral=2.25v to 2.75v Vacuum fan relay Signal to turn control board ON Output in series to charger safety,E-stop,& key switches Battery Discharge Indicator Communicates battery & control board information (up to 10v) Battery (-) output for various components Output to vacuum switch, CR3 actuator relay, Battery Discharge Indicator, & low battery voltage lockout select Vacuum switch BATTERY DISCHARGE INDICATOR CONNECTIONS Name Battery Discharge Indicator 32 Pin # Wire # 1 2 3 4 34 9 13J 13F Color Active Voltage yellow white 10v to 24v black 0v black 0v battery (+) Inactive Voltage x x 0v 0v Input/ Output input input input input Function Battery (+) supply voltage Battery status signal Battery (-) supply voltage Static drain path Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – BDI Diagnostic Fault Indicators LED Flashing Codes 1 BAR FLASHING Very Low Battery Voltage The batteries need immediate charging or there is a bad connection to the batteries. Charge the batteries,or check the connections to the battery. 2 BARS FLASHING Low Battery Voltage (Slowly Flashing @ 40Hz) The batteries need charging or there is a bad connection to the batteries. Charge the batteries,or check the connections to the battery. 2 BARS FLASHING Propel Motor Open (Quickly Flashing @ 200 Hz) The propel motor has an open connection. Check all the connections and wires between the motor and the control board. Test motor for open circuit. The propel motor has a short circuit. Check all the connections 3 BARS FLASHING 4 BARS FLASHING 5 BARS FLASHING 6 BARS FLASHING 7 BARS FLASHING 8 BARS FLASHING 9 BARS FLASHING 10 BARS FLASHING Propel Motor Shorted and wires between the motor and the control board. Test motor for short circuit. Battery Lockout The voltage level of the batteries has fallen below the Battery Lockout Level and the control board is inhibiting certain machine functions. Charge the batteries. Not Used Not Used Not Used Possible Control Board Fault A control board fault is indicated. Make sure that all connections are secure. Not Used High Battery Voltage An excessive voltage has been applied to the controller. This is usually caused by a poor battery connection. Check all battery connections. Control Board in Sleep Mode (LED's flash The controller has entered sleep mode. Switch the control one at a time from left to right) system off and then on again. A throttle fault is indicated. Make sure that the forward and reverse switches are released before switching on the (LED's ripple back and forth) machine, or check all connections and wires from the switches to the control board. Throttle Displaced Nobles Speed Scrub 9002377 REV.00 (08-06) 33 Speed Scrub - Key OFF Power Distribution (With Standard Off-Board Battery Charger) CONDITIONS: Key OFF, off-board battery charger NOT CONNECTED to charger plug 6 VDC + 1 RED - + 6 VDC 1 RED F1 100A - + 6 VDC - 22 1 RED CR1 2 1 RED 42 1 RED - 13 BLK 13 BLK CHARGER PLUG F2 30A v 6 VDC + CONTROL BOARD 22 + - TO CIRCUIT BREAKER CB1 13 BLK 1 2 TO CIRCUIT BREAKER CB2 1 2 CR2 10 38 CR3 1 RED TO CIRCUIT BREAKER CB3 54 54 TO CIRCUIT BREAKER CB4 58 F3 7.5A 1 RED 18 74 74 78 TO FUSE F4 CR4 28 TO FaST PUMP MOTOR M6 7 6 5 4 3 2 1 14 13 12 11 10 13 BLK 9 9 9 8 13 BLK 54 54 BATTERY DISCHARGE INDICATOR 4 54 Wiring Color Codes CHARGER SAFETY SWITCH 14 EMERGENCY STOP SWITCH (Unless otherwise marked) Right Most Digit of Wire Number Color of Wire Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White 34 34 KEY SWITCH 64 CR3 13 BLK 13 BLK 1 2 3 4 9 13 BLK ACTUATOR RELAY Tan 0 1 24 ! Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i If Charger Plug is connected to battery charger, ALL machine functions will be disabled when Key Switch is turned ON = Battery Negative or Logic Ground = Battery Positive or Logic High 34 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub - Key OFF Power Distribution (With Standard Off-Board Battery Charger) CONDITIONS: Key OFF, off-board battery charger CONNECTED to charger plug 6 VDC + 1 RED - + 6 VDC 1 RED F1 100A - + 6 VDC - 22 1 RED CR1 2 1 RED 42 1 RED - 13 BLK 13 BLK CHARGER PLUG F2 30A v 6 VDC + CONTROL BOARD 22 + - TO CIRCUIT BREAKER CB1 13 BLK 1 2 TO CIRCUIT BREAKER CB2 1 2 CR2 10 38 CR3 1 RED TO CIRCUIT BREAKER CB3 54 54 TO CIRCUIT BREAKER CB4 58 F3 7.5A 1 RED 18 74 74 78 TO FUSE F4 CR4 28 TO FaST PUMP MOTOR M6 7 6 5 4 3 2 1 14 13 12 11 10 13 BLK 9 9 9 8 13 BLK 54 54 CHARGER SAFETY SWITCH BATTERY DISCHARGE INDICATOR 4 54 14 EMERGENCY STOP SWITCH Wiring Color Codes (Unless otherwise marked) Right Most Digit of Wire Number Color of Wire Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White 34 34 KEY SWITCH 64 CR3 13 BLK 13 BLK 1 2 3 4 9 13 BLK ACTUATOR RELAY Tan 0 1 24 ! Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i If Charger Plug is connected to battery charger, ALL machine functions will be disabled when Key Switch is turned ON = Battery Negative or Logic Ground = Battery Positive or Logic High Nobles Speed Scrub 9002377 REV.00 (08-06) 35 Speed Scrub - Key OFF Power Distribution (With Optional On-Board Battery Charger) CONDITIONS: Key OFF, On-Board battery charger NOT CONNECTED to AC power RED + 1 RED F1 100A v 6 VDC - + - + 6 VDC - 22 CR1 2 6 VDC + F2 30A 1 RED 42 - 13 BLK CONTROL BOARD 22 + - TO CIRCUIT BREAKER CB1 1 RED 1 RED 6 VDC 13 BLK 1 2 TO CIRCUIT BREAKER CB2 1 2 CR2 10 TO CIRCUIT BREAKER CB3 38 CR3 1 RED 54 54 TO CIRCUIT BREAKER CB4 74 78 58 F3 7.5A 1 RED 18 74 TO FUSE F4 CR4 28 TO FaST PUMP MOTOR M6 7 6 5 4 3 2 1 14 13 12 11 10 13 BLK 9 9 9 8 13 BLK 54 54 54 ON-BOARD CHARGER 4 14 EMERGENCY STOP SWITCH AC RED BATTERY DISCHARGE INDICATOR Right Most Digit of Wire Number BLACK 34 KEY SWITCH 64 CR3 13 BLK 1 2 3 4 13 BLK 9 13 BLK Color of Wire AC POWER CORD Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White NOT CONNECTED TO AC = Battery Negative or Logic Ground = Battery Positive or Logic High 36 34 ACTUATOR RELAY Wiring Color Codes (Unless otherwise marked) 24 ! Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i The battery charger uses a normally closed relay to send a signal to the control board – the relay opens when the charger is plugged in to AC power i If On-Board Charger is connected to AC power, ALL machine functions will be disabled when Key Switch is turned ON Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub - Key OFF Power Distribution (With Optional On-Board Battery Charger) CONDITIONS: Key OFF, On-Board battery charger CONNECTED to AC power RED + 1 RED F1 100A v 6 VDC - + - + 6 VDC - 22 CR1 2 6 VDC + F2 30A 1 RED 42 - 13 BLK CONTROL BOARD 22 + - TO CIRCUIT BREAKER CB1 1 RED 1 RED 6 VDC 13 BLK 1 2 TO CIRCUIT BREAKER CB2 1 2 CR2 10 TO CIRCUIT BREAKER CB3 38 CR3 1 RED 54 54 TO CIRCUIT BREAKER CB4 74 78 58 F3 7.5A 1 RED 18 74 TO FUSE F4 CR4 28 TO FaST PUMP MOTOR M6 7 6 5 4 3 2 1 14 13 12 11 10 13 BLK 9 9 9 8 13 BLK 54 54 54 ON-BOARD CHARGER BATTERY DISCHARGE INDICATOR 4 EMERGENCY STOP SWITCH AC RED 14 Right Most Digit of Wire Number 34 34 KEY SWITCH 64 CR3 13 BLK 1 2 3 4 13 BLK 9 13 BLK ACTUATOR RELAY Wiring Color Codes (Unless otherwise marked) 24 BLACK Color of Wire AC POWER CORD Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White CONNECTED TO AC = Battery Negative or Logic Ground = Battery Positive or Logic High Nobles Speed Scrub 9002377 REV.00 (08-06) ! Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i The battery charger uses a normally closed relay to send a signal to the control board – the relay opens when the charger is plugged in to AC power i If On-Board Charger is connected to AC power, ALL machine functions will be disabled when Key Switch is turned ON 37 Speed Scrub - Key ON Power Distribution CONDITIONS: Key ON i The troubleshooting information from this page forward applies to machines with On-Board or Off-Board Chargers unless otherwise noted + 1 RED - + 6 VDC - 1 RED F1 100A v 6 VDC CR1 TO CIRCUIT BREAKER CB1 42 TO CIRCUIT BREAKER CB2 10 TO CIRCUIT BREAKER CB3 CR2 1 RED 22 2 1 RED 6 VDC - + - 1 2 54 4 CHARGER SAFETY SWITCH 58 F3 7.5A 1 RED 18 14 7 6 5 4 3 2 1 74 24 KEY EMERGENCY SWITCH STOP SWITCH TO CIRCUIT BREAKER CB4 78 13 BLK 1 2 74 1 RED 13 BLK CONTROL BOARD 22 54 38 - 13 BLK 54 CR3 6 VDC + CHARGER PLUG F2 30A 1 RED + 14 13 12 11 10 13 BLK 9 9 8 13 BLK TO FUSE F4 BATTERY DISCHARGE INDICATOR CR4 28 TO FaST PUMP MOTOR M6 34 34 Wiring Color Codes (Unless otherwise marked) Right Most Digit of Wire Number 64 Color of Wire Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White = Battery Negative or Logic Ground 9 CR3 13 BLK 1 2 3 4 13 BLK 9 13 BLK ACTUATOR RELAY ! Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i If Charger Plug is connected to battery charger, ALL machine functions will be disabled when Key Switch is turned ON = Battery Positive or Logic High 38 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Propel Forward System CONDITIONS: Key ON, forward propel engaged + 1 RED - + 6 VDC - + 1 RED F1 100A v 6 VDC - 6 VDC + 22 + - 84 1 2 19 M4 PROPEL MOTOR FORWARD 5V REFERENCE 32 13 BLK 1 2 19 84 13 BLK CONTROL BOARD 22 84 - 13 BLK CHARGER PLUG F2 30A 1 RED 6 VDC 32 SIGNAL INPUT 3 7 6 5 4 3 2 1 14 13 12 11 10 9 8 5 0V REFERENCE SPEED LIMITER POTENTIOMETER 50KΩ DIRECTION SWITCH 31 X RIGHT TRIGGER SWITCH 32 Wiring Color Codes REVERSE 41 FORWARD RECOVERY TANK PROPEL INTERLOCK SWITCH 39 39 (Unless otherwise marked) Right Most Digit of Wire Number Color of Wire Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White 49 52 LEFT TRIGGER SWITCH ! = Battery Negative or Logic Ground = Battery Positive or Logic High Nobles Speed Scrub 9002377 REV.00 (08-06) i Only one trigger switch needs to be closed to propel machine forward Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i The Propel Motor (M4) is controlled by PWM; A higher duty cycle will result in higher travel speed i If Charger Plug is connected to battery charger, ALL machine functions will be disabled when Key Switch is turned ON 39 Speed Scrub – Propel Reverse System CONDITIONS: Key ON, reverse propel engaged + 1 RED - + 6 VDC - + 1 RED F1 100A v 6 VDC - 6 VDC + 22 + - 84 1 2 19 M4 PROPEL MOTOR REVERSE 5V REFERENCE 32 13 BLK 1 2 19 84 13 BLK CONTROL BOARD 22 84 - 13 BLK CHARGER PLUG F2 30A 1 RED 6 VDC 32 SIGNAL INPUT 3 7 6 5 4 3 2 1 14 13 12 11 10 9 8 5 0V REFERENCE SPEED LIMITER POTENTIOMETER 50KΩ DIRECTION SWITCH 31 X 32 FORWARD RECOVERY TANK PROPEL INTERLOCK SWITCH RIGHT TRIGGER SWITCH Wiring Color Codes REVERSE 41 39 39 (Unless otherwise marked) Right Most Digit of Wire Number Color of Wire Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White = Battery Negative or Logic Ground = Battery Positive or Logic High 40 49 52 LEFT TRIGGER SWITCH ! Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i The Propel Motor (M4) is controlled by PWM; A higher duty cycle will result in higher travel speed i If Charger Plug is connected to battery charger, ALL machine functions will be disabled when Key Switch is turned ON Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Scrub Brushes CONDITIONS: Key ON, Scrub Head lowered for cleaning, propel engaged + 1 RED - + 6 VDC - + 1 RED F1 100A v 6 VDC - + 22 6 VDC - 13 BLK 13 BLK CHARGER PLUG F2 30A 1 RED 6 VDC 22 CONTROL BOARD + - 13 BLK 1 2 25 25 1 2 27 25 26 SCRUB/TRANSPORT SWITCH (INTERNAL TO SCRUB HEAD ACTUATOR) CB1 25A 2 7 6 5 4 3 2 1 7 CR1 BRUSH CONTACTOR BRUSH PRESSURE GAUGE RIGHT BRUSH MOTOR 59 12 M1 14 13 12 11 10 9 8 13 BLK 13 BLK 13 BLK 13 BLK CR1 1 RED CB2 25A 42 33 M2 LEFT BRUSH MOTOR Wiring Color Codes (Unless otherwise marked) Right Most Digit of Wire Number Color of Wire Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White ! = Battery Negative or Logic Ground = Battery Positive or Logic High Nobles Speed Scrub 9002377 REV.00 (08-06) Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i If Charger Plug is connected to battery charger, ALL machine functions will be disabled when Key Switch is turned ON i The Scrub/Transport Switch closes when the Scrub Head Actuator extends (lowers) 2” (50mm) or more i The Brush Pressure Gauge monitors current on the Right brush motor only 41 Speed Scrub – Vacuum Fan System CONDITIONS: Key ON, Squeegee lowered + 1 RED - + 6 VDC - 1 RED F1 100A v 6 VDC 6 VDC - + 6 VDC - CONTROL BOARD 22 + - 13 BLK 1 2 54 54 44 4 CHARGER SAFETY SWITCH 44 14 CR2 74 29 44 29 7 6 5 4 3 2 1 14 13 12 11 10 9 8 29 VACUUM FAN RELAY CB3 25A CR2 1 RED 24 KEY EMERGENCY SWITCH STOP SWITCH VACUUM FAN SWITCH 1 2 54 54 13 BLK 13 BLK CHARGER PLUG F2 30A 1 RED + 20 10 M3 13 BLK 13 BLK VACUUM FAN MOTOR Wiring Color Codes (Unless otherwise marked) Right Most Digit of Wire Number Color of Wire Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White ! Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i If Charger Plug is connected to battery charger, ALL machine functions will be disabled when Key Switch is turned ON = Battery Negative or Logic Ground = Battery Positive or Logic High 42 Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Conventional Solution Valve, Hour Meter CONDITIONS: Key ON, scrub head lowered for cleaning, propel engaged, conventional scrub selected - + 6 VDC - + 1 RED F1 100A v 6 VDC + 1 RED 7 22 + 26 BRUSH CONTACTOR + - 25 FaST RELAY 6 30 FaST FaST/ CONVENTIONAL SWITCH 17 27 1 2 7 6 5 4 3 2 1 CONV 8 30 CR4 13 BLK 1 2 8 37 13 BLK 6 6 CONVENTIONAL SOLUTION VALVE - CONTROL BOARD 25 SCRUB/TRANSPORT SWITCH (INTERNAL TO SCRUB HEAD ACTUATOR) 47 6 VDC 13 BLK 22 26 CR1 - CHARGER PLUG F2 30A 1 RED 6 VDC 16 14 13 12 11 10 9 8 16 HOUR METER 27 27 F3 7.5A 1 RED CR4 18 28 M6 Wiring Color Codes 13 BLK FaST PUMP MOTOR (Unless otherwise marked) Right Most Digit of Wire Number 13 BLK Color of Wire Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White ! = Battery Negative or Logic Ground = Battery Positive or Logic High Nobles Speed Scrub 9002377 REV.00 (08-06) Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i If Charger Plug is connected to battery charger, ALL machine functions will be disabled when Key Switch is turned ON i The Scrub/Transport Switch closes when the Scrub Head Actuator extends (lowers) 2” (50mm) or more i The Hour Meter is activated only when the Scrub Head is lowered, and propel is engaged 43 Speed Scrub – FaST Pump, Hour Meter CONDITIONS: Key ON, scrub head lowered for cleaning, propel engaged, FaST scrub selected - + 6 VDC - + 1 RED F1 100A v 6 VDC + 1 RED 7 22 + 26 BRUSH CONTACTOR + - 25 FaST RELAY 6 30 FaST FaST/ CONVENTIONAL SWITCH 16 17 27 1 2 7 6 5 4 3 2 1 CONV 8 30 CR4 13 BLK 1 2 8 37 13 BLK 6 6 CONVENTIONAL SOLUTION VALVE - CONTROL BOARD 25 SCRUB/TRANSPORT SWITCH (INTERNAL TO SCRUB HEAD ACTUATOR) 47 6 VDC 13 BLK 22 26 CR1 - CHARGER PLUG F2 30A 1 RED 6 VDC 14 13 12 11 10 9 8 16 HOUR METER 27 27 F3 7.5A 1 RED CR4 18 28 M6 Wiring Color Codes Color of Wire Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White = Battery Negative or Logic Ground = Battery Positive or Logic High 44 13 BLK FaST PUMP MOTOR (Unless otherwise marked) Right Most Digit of Wire Number 13 BLK ! Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i If Charger Plug is connected to battery charger, ALL machine functions will be disabled when Key Switch is turned ON i The Scrub/Transport Switch closes when the Scrub Head Actuator extends (lowers) 2” (50mm) or more i The Hour Meter is activated only when the Scrub Head is lowered, and propel is engaged Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Scrub Head Actuator LOWER (Extend) CONDITIONS: Key ON, scrub head lower switch activated + 1 RED - + 6 VDC - 1 RED F1 100A v 6 VDC 7 - + 6 VDC 22 26 + - 27 13 BLK 1 2 25 SCRUB/TRANSPORT SWITCH (INTERNAL TO SCRUB HEAD ACTUATOR) BRUSH CONTACTOR 13 BLK CONTROL BOARD 22 26 CR1 - 13 BLK CHARGER PLUG F2 30A 1 RED 6 VDC + 25 1 2 27 54 7 6 5 4 3 2 1 54 74 74 54 4 CHARGER SAFETY SWITCH 14 24 KEY EMERGENCY SWITCH STOP SWITCH ACTUATOR RELAY 64 78 38 13 BLK SHOWN IN OPERATION DURING LOWERING OF SCRUB HEAD 40 40 RAISE RAISE LIMIT SWITCH 23 Right Most Digit of Wire Number TO FUSE F4 Wiring Color Codes (Unless otherwise marked) EXTERNAL LOWER LIMIT 56 SWITCH 68 13 BLK LOWER 56 68 Tan Pink 2 Brown 3 Orange 4 Yellow 5 Green Scrub Head Actuator Logic Chart switch Blue Purple Fully Retracted (UP) 8 Gray Fully Extended (DOWN) 9 White Retracting (RAISING) Extending (LOWERING) Nobles Speed Scrub 9002377 REV.00 (08-06) LOWER LIMIT SWITCH 13 BLK 7 = Battery Positive or Logic High SCRUB HEAD ACTUATOR 13 BLK 6 = Battery Negative or Logic Ground INTERNAL SWITCHES M5 50 Color of Wire 0 1 13 BLK 9 8 13 BLK CB4 10A CR3 1 RED CR3 14 13 12 11 10 condition Scrub/ Transport Internal Switches Raise Lower Limit Limit External Switch Lower Limit OPEN OPEN CLOSED CLOSED CLOSED CLOSED OPEN OPEN CLOSED CLOSED * CLOSED CLOSED CLOSED CLOSED * * Scrub/Transport Switch closes when actuator is extended 2" (50mm) or more 45 Speed Scrub – Scrub Head Actuator RAISE (Retract) CONDITIONS: Key ON, scrub head raise switch activated + 1 RED - + 6 VDC - 1 RED F1 100A v 6 VDC 7 - 6 VDC + 22 26 + - 27 13 BLK 1 2 25 SCRUB/TRANSPORT SWITCH (INTERNAL TO SCRUB HEAD ACTUATOR) BRUSH CONTACTOR 13 BLK CONTROL BOARD 22 26 CR1 - 13 BLK CHARGER PLUG F2 30A 1 RED 6 VDC + 25 1 2 27 54 7 6 5 4 3 2 1 54 74 74 4 54 CHARGER SAFETY SWITCH 14 24 KEY EMERGENCY SWITCH STOP SWITCH ACTUATOR RELAY 64 78 38 40 40 13 BLK SHOWN IN OPERATION DURING RAISING OF SCRUB HEAD RAISE RAISE LIMIT SWITCH 23 Right Most Digit of Wire Number TO FUSE F4 Wiring Color Codes (Unless otherwise marked) 56 56 LOWER 68 Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 68 SCRUB HEAD ACTUATOR LOWER LIMIT SWITCH 13 BLK 13 BLK Scrub Head Actuator Logic Chart switch 6 Blue 7 Purple Fully Retracted (UP) 8 Gray Fully Extended (DOWN) 9 White Retracting (RAISING) Extending (LOWERING) = Battery Positive or Logic High INTERNAL SWITCHES M5 50 Color of Wire = Battery Negative or Logic Ground 46 EXTERNAL LOWER LIMIT SWITCH 13 BLK 13 BLK 9 8 13 BLK CB4 10A CR3 1 RED CR3 14 13 12 11 10 condition Scrub/ Transport Internal Switches Raise Lower Limit Limit External Switch Lower Limit OPEN OPEN CLOSED CLOSED CLOSED CLOSED OPEN OPEN CLOSED CLOSED * CLOSED CLOSED CLOSED CLOSED * * Scrub/Transport Switch closes when actuator is extended 2" (50mm) or more Nobles Speed Scrub 9002377 REV.00 (08-06) Speed Scrub – Wand Pump CONDITIONS: Key ON, wand pump switch ON + 1 RED - + 6 VDC - 1 RED F1 100A v 6 VDC 6 VDC - + 6 VDC 22 - 13 BLK 13 BLK CHARGER PLUG F2 30A 1 RED + 22 CONTROL BOARD + - 13 BLK 1 2 1 2 54 54 74 74 54 4 CHARGER SAFETY SWITCH 14 24 KEY EMERGENCY SWITCH STOP SWITCH ACTUATOR RELAY 64 78 58 38 (Unless otherwise marked) Right Most Digit of Wire Number 13 BLK 9 8 13 BLK 13 BLK M7 WAND PUMP SWITCH Wiring Color Codes 14 13 12 11 10 F4 7.5A CR3 1 RED CR3 7 6 5 4 3 2 1 WAND PUMP MOTOR TO CIRCUIT BREAKER CB4 Color of Wire Tan 0 1 Pink 2 Brown 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White ! Be cautious when working near Control Board Battery voltage is always present, even with Key OFF i If Charger Plug is connected to battery charger, ALL machine functions will be disabled when Key Switch is turned ON = Battery Negative or Logic Ground = Battery Positive or Logic High Nobles Speed Scrub 9002377 REV.00 (08-06) 47
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 5.5-c021 79.153613, 2013/07/11-05:21:54 Manual Type : Service Manual Format : application/pdf Site Brand : nobles Is Purchasable : true Region : am Doc Status : Active Modified : 2016:10:17 18:10:07.338-05:00 Sales Channel : Commercial Category : manual Power Source : Battery Share With Recon Machines : true Document Number : 9002377 Brand : NOB Security : Secure Creator : Steve Floyd Marketing Channel : DST, SLS, SRV, EMP, DIR, KSA, SSP Description : Speed Scrub 24-32 Service Manual Language : en, all Title : Speed Scrub 24-32 Service Manual Num Pages : 51 Extracted : 2016:10:17 18:08:15.989-05:00 Author : Steve Floyd Sha 1 : 091638764b33161f53bd330ea2b60f004c9a304e Size : 3717987 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:05:27 11:24:24.000-05:00 Modify Date : 2015:05:27 11:24:24.000-05:00 Create Date : 2006:07:30 20:11:27.000-05:00 Document ID : uuid:e9f8e8d4-6425-482c-876c-793e863f33aa Instance ID : uuid:705aab1e-7dfc-4c02-ad67-2b9a68626ef8 Producer : Acrobat Distiller 7.0.5 (Windows) Tags : product-category-tag:nobles/en_us/1/machines/scrubbers/scrubberswalkbehind, product-tag:tennant/en_us/1/machines/scrubbers/M-SS5 Page Layout : SinglePage Page Mode : UseOutlines Page Count : 51 Subject : Speed Scrub 24-32 Service ManualEXIF Metadata provided by EXIF.tools