Tennant T5 English Operator Manual
2012-03-08
: Sweepscrub T5 Operator Manual T5_operator_manual 372 file product_file
Open the PDF directly: View PDF .
Page Count: 37
Download | |
Open PDF In Browser | View PDF |
T5 Scrubber--Dryer Operator Manual The Safe Scrubbing Alternativer HygenicR Fully Cleanable Tanks QA Controlst Supervisor Settings North America / International 9002326 Rev. 06 (11--2008) *9002326* www.tennantco.com Home Find... Go To.. OPERATION This manual is furnished with each new model. It provides necessary operation and maintenance instructions. Read this manual completely and understand the machine before operating or servicing it. A complete illustrated Parts Manual is also furnished with each new model. Use the Parts Manual to order replacement parts. To ensure prompt delivery, follow the “HOW TO ORDER PARTS” instructions printed in the Parts Manual. MACHINE DATA IMPORTANT: To ensure full warranty protection, fill out the attached MACHINE INSTALLATION / WARRANTY REPORT REPLY CARD and return to Tennant within 30 days of purchase. Please fill out at time of installation for future reference. This machine will provide excellent service. However, the best results will be obtained at minimum costs if: Model No. -- S The machine is operated with reasonable care. Serial No. -- S The machine is maintained regularly - per the Machine Options -- machine maintenance instructions provided. S The machine is maintained with manufacturer supplied or equivalent parts. Sales Rep. -Sales Rep. phone no. -Customer Number -- PROTECT THE ENVIRONMENT Please dispose of packaging materials, old machine components such as batteries, hazardous fluids, including antifreeze and oil, in an environmentally safe way according to local waste disposal regulations. Installation Date -- Always remember to recycle. TENNANT Company PO Box 1452 Minneapolis, MN 55440 Phone: (800) 553--8033 or (763) 513--2850 www.tennantco.com FaSK--PAK and 1--STEP are US registered and unregistered trademarks of Tennant Company. Specifications and parts are subject to change without notice. Copyright E 2006, 2007, 2008 TENNANT COMPANY, Printed in U.S.A. All rights reserved. 2 Home Find... Go To.. Tennant T5 (09--08) OPERATION TABLE OF CONTENTS SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . 4 SAFETY LABELS . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 MACHINE COMPONENTS . . . . . . . . . . . . . . . . . . . 6 CONTROL PANEL COMPONENTS . . . . . . . . . . . 7 MACHINE INSTALLATION . . . . . . . . . . . . . . . . . . . UNCRATING MACHINE . . . . . . . . . . . . . . . . . . INSTALLING BATTERIES . . . . . . . . . . . . . . . . 8 8 8 HOW THE MACHINE WORKS . . . . . . . . . . . . . . . 9 BRUSH AND PAD INFORMATION . . . . . . . . . . . . 9 MACHINE SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . ATTACHING SQUEEGEE ASSEMBLY . . . . . INSTALLING BRUSHES . . . . . . . . . . . . . . . . . . iNSTALLING FaST--PAK CARTON (FaST Model) . . . . . . . . . . . . . . . . . FILLING SOLUTION TANK . . . . . . . . . . . . . . . 9 9 10 MACHINE OPERATION . . . . . . . . . . . . . . . . . . . . . PRE--OPERATION CHECKS . . . . . . . . . . . . . . STARTING THE MACHINE . . . . . . . . . . . . . . . EMERGENCY STOPPING . . . . . . . . . . . . . . . . WHILE OPERATING MACHINE . . . . . . . . . . . BATTERY CHARGE LEVEL INDICATOR . . . HOUR METER . . . . . . . . . . . . . . . . . . . . . . . . . . OFF--AISLE WAND SETUP AND OPERATION . . . . . . . . . . . . . . . . . . . . . . DRAINING AND CLEANING TANKS . . . . . . . . . . DRAINING RECOVERY TANK . . . . . . . . . . . . DRAINING SOLUTION TANK . . . . . . . . . . . . . Tennant T5 (11--08) Home CHARGING BATTERIES . . . . . . . . . . . . . . . . . . . . BATTERY CHARGER SPECIFICATIONS: . . ON--BOARD BATTERY CHARGER SETTINGS: . . . . . . . . . . . . . . . . . . . . . . . . . . . . USING THE ON--BOARD BATTERY CHARGER . . . . . . . . . . . . . . . . . . . ON--BOARD BATTERY CHARGER ERROR CODES . . . . . . . . . . . . . ON--BOARD CHARGER FUSE REPLACEMENT . . . . . . . . . . . . . . . . . USING AN OFF--BOARD BATTERY CHARGER (OPTION) . . . . . . . . . . . . . . . . . . . 17 17 17 18 19 20 20 ADJUSTING SCRUB HEAD BRUSHES . . . . . . . DISK MODEL . . . . . . . . . . . . . . . . . . . . . . . . . . . CYLINDRICAL BRUSH MODEL . . . . . . . . . . . 21 21 21 12 12 12 14 14 14 15 MACHINE MAINTENANCE . . . . . . . . . . . . . . . . . . DAILY MAINTENANCE . . . . . . . . . . . . . . . . . . MONTHLY MAINTENANCE . . . . . . . . . . . . . . . BATTERY MAINTENANCE . . . . . . . . . . . . . . . SQUEEGEE BLADES . . . . . . . . . . . . . . . . . . . . MOTOR MAINTENANCE . . . . . . . . . . . . . . . . . FaST SYSTEM MAINTENANCE . . . . . . . . . . . ec--H2O MODULE FLUSH PROCEDURE . . . 23 23 25 26 26 27 27 28 JACKING UP MACHINE . . . . . . . . . . . . . . . . . . . . . 28 15 TRANSPORTING MACHINE . . . . . . . . . . . . . . . . . 29 16 16 17 STORING MACHINE . . . . . . . . . . . . . . . . . . . . . . . . FREEZE PROTECTION . . . . . . . . . . . . . . . . . . 29 29 RECOMMENDED STOCK ITEMS . . . . . . . . . . . . . 31 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . 31 CONTROL PANEL FAULT INDICATOR CODES 34 MACHINE SPECIFICATIONS . . . . . . . . . . . . . . . . 35 MACHINE DIMENSIONS . . . . . . . . . . . . . . . . . . . . 37 11 12 Find... Go To.. 3 OPERATION FOR SAFETY: SAFETY PRECAUTIONS This machine is intended for industrial and commercial use. It is designed exclusively to scrub hard floors in an indoor environment and is not constructed for any other use. Only use recommended pads, brushes and commercially approved floor cleaners intended for machine application. The following warning alert symbol and the “FOR SAFETY” heading are used throughout this manual as indicated in their description: WARNING: To warn of hazards or unsafe practices which could result in severe personal injury or death. FOR SAFETY: To identify actions which must be followed for safe operation of equipment. The following safety precautions signal potentially dangerous conditions to the operator or equipment. All operators must read, understand and practice them. WARNING: Fire Or Explosion Hazard -- Never Use Flammable Liquids Or Operate Machine In Or Near Flammable Liquids, Vapors Or Combustible Dusts. This machine is not equipped with explosion proof motors. The electric motors will spark upon start up and during operation which could cause a flash fire or explosion if machine is used in an area where flammable vapors/liquids or combustible dusts are present. -- Do Not Pick Up Flammable Materials Or Reactive Metals. -- Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. WARNING: Electrical Hazard -- Disconnect Battery Cables and Charger Plug Before Servicing Machine. -- Do Not Charge Batteries with Damaged Power Supply Cord. Do Not Modify Plug. If the charger supply cord is damaged or broken, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. 1. Do not operate machine: -- With flammable liquids or near flammable vapors as an explosion or flash fire may occur. -- Unless trained and authorized. -- Unless operator manual is read and understood. -- If not in proper operating condition. 2. Before starting machine: -- Make sure all safety devices are in place and operate properly. 3. When using machine: -- Go slow on inclines and slippery surfaces. -- Wear non--slip shoes. -- Reduce speed when turning. -- Report machine damage or faulty operation immediately. -- Never allow children to play on or around. -- Follow mixing and handling instructions on chemical containers. -- Do not operate on inclines that exceed 5% (3°). 4. Before leaving or servicing machine: -- Stop on level surface. -- Turn off machine. -- Set parking brake, if equipped. -- Remove key. 5. When servicing machine: -- Avoid moving parts. Do not wear loose jackets, shirts, or sleeves. -- Disconnect battery cables and charger plug before working on machine. -- Wear protective gloves and eye protection when handling batteries or battery cables. -- Avoid contact with battery acid. -- Wear protective gloves and eye protection when handling white vinegar. -- Do not power spray or hose off machine. Electrical malfunction may occur. -- Jack machine up at designated locations only (See JACKING UP MACHINE). -- Use hoist or jack that will support machine weight. -- Use manufacturer supplied or approved replacement parts. -- All repairs must be performed by a qualified service person. -- Do not modify the machine from its original design. WARNING: Spinning Brush. Keep Hands Away. Turn Off Power Before Working On Machine. 4 Home Find... Go To.. Tennant T5 (11--08) OPERATION 6. When loading/unloading machine onto/off truck or trailer: -- Drain tanks before loading. -- Use a ramp that can support the machine weight and person loading it. Do not exceed a 11° ramp incline at a ramp length of 12 ft (3.7m). ------ Turn machine off. Put scrub head in the lowered position. Block machine wheels. Use tie--down straps to secure machine. Set parking brake, if equipped. SAFETY LABELS The safety labels appear on the machine in the locations indicated. Replace labels if they are missing or become damaged or illegible. WARNING LABEL -Located on recovery tank cover. SPINNING BRUSH LABEL - Located on scrub head WARNING: Spinning Brush. Keep Hands Away. Turn Off Power Before Working On Machine. BATTERY CHARGE LABEL -Located on bottom side of recovery tank. WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. Tennant T5 (06--06) Home Find... Go To.. 5 OPERATION MACHINE COMPONENTS 13 14 15 16 28 1 2 15 17 21 20 3 19 18 6 4 7 22 8 5 9 23 27 10 24 12 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 6 Control Handle Control Handle Start Bail Upper & Lower Control Panels Recovery Tank Drain Hose On--board Battery Charger Squeegee Lift Lever Rear Fill-Port Solution Tank Level/Drain Hose Squeegee Vacuum hose Wall Rollers Squeegee Assembly Solution Tank Clean-Out Port Recovery Tank Support Stand Control Board Bucket Fill Port/Clean--out Port Home 11 25 26 16. FaST--PAK Carton Compartment (FaST Model) ec--H2O System Module (ec--H2O Model) 17. Batteries 18. Off--Aisle Wand Solution Hose Coupler 19. Recovery Tank 20. Recovery Tank Cover 21. Cup Holder 22. Solution Tank 23. Disk Scrub Head 24. Pad Release Plunger 25. Pad Driver Window 26. Scrub Head Skirt 27. Parking Brake (option) 28. Cylindrical Brush Scrub Head Find... Go To.. Tennant T5 (09--08) OPERATION CONTROL PANEL COMPONENTS 1 2 3 5 4 6 7 8 9 10 ec- H2O Model 13 14 15 12 1. 2. 3. 4. 5. 6. 7. 8. 11 Speed control knob 1--STEP scrub button Brush pressure increase button (+) Brush pressure decrease button (--) Solution flow increase button (+) Solution flow decrease button (--) Fault indicator -- Contact Service Supervisor control indicator -- Lockout feature Tennant T5 (09--08) Home Find... Go To.. 12 9. 10. 11. 12. Battery charge level indicator Emergency stop button (option) Off--Aisle wand on/off switch (option) FaST system on/off switch (FaST model) ec--H2O system on/off switch (ec--H2O model) 13. ec--H2O system indicator light (ec--H2O model) 14. Main power on/off key switch 15. Hour meter 7 OPERATION MACHINE INSTALLATION UNCRATING MACHINE 1. Carefully check the shipping crate for signs of damage. Report damage at once to carrier. 2. Check the contents list. Contact distributor for missing items. Contents: S 4--6 V Batteries--Optional S 3--Battery Cable Jumpers S Battery Tray S 1--FaST--PAK 365 Concentrate--(FaST model) S Squeegee Assembly S 2--Pad drivers (Disk Model) S 2--Brushes (Cylindrical Brush Model) FIG. 1 3. Carefully install the batteries into the battery compartment tray (Figure 2). Arrange the battery posts as shown (Figure 3). 3. To uncrate your machine, remove the shipping hardware and straps that secure the machine to the pallet. Carefully back machine down ramp. ATTENTION: Do not roll machine off pallet unless a ramp is used, machine damage may occur. ATTENTION: To prevent possible machine damage, install batteries after removing machine from shipping pallet. FIG. 2 INSTALLING BATTERIES WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Hood Open When Charging. 4. Connect the battery cables to the battery posts as shown (Figure 3), RED TO POSITIVE (+) and BLACK TO NEGATIVE (--). 200A/20H 235A/20H FOR SAFETY: When installing batteries, wear protective gloves and eye protection. Avoid contact with battery acid. BLACK Battery Specifications: Four 6 volt, 200A/20h or 235A/20h deep cycle batteries. Maximum battery dimensions: 7.5 in (190 mm) W x 10.8 in (275 mm) L x 11 in (284 mm) H. Machine Front RED 1. Park the machine on a level surface, remove the key and set the parking brake. 2. Lift the recovery tank and remove the right side battery compartment panel (Figure 1). 13mm wrench required. 8 Home FIG. 3 IMPORTANT: If your machine is equipped with the on--board battery charger, make sure that the charger is properly set for your battery type before charging (See ON--BOARD CHARGER SETTINGS). Find... Go To.. Tennant T5 (06--06) OPERATION HOW THE MACHINE WORKS Conventional Scrubbing: Water and detergent from the solution tank flow to the floor through a solution valve. The brushes use the detergent and water to scrub the floor clean. As the machine moves forward, the squeegee wipes the dirty solution from the floor into the recovery tank. Foam Scrubbing (FaST Model): (FaST--Foam activated Scrubbing Technology) Unlike conventional scrubbing, the FaST system injects the FaST--PAK concentrate formula with a small amount of water and air onto the floor. The mixture creates a large volume of expanded wet foam for the brush to scrub the floor clean. As the machine moves forward, the foam collapses and the squeegee recovers the dirty solution into the recovery tank leaving the floor clean, dry and slip free. ec- H2O Scrubbing (ec- H2O Model): (ec--H2O--electrically converted water) Normal water passes through a module where it is oxygenated and charged with an electric current. The electrically converted water changes into a blended acidic and alkaline solution forming a neutral pH cleaner. The converted water attacks the dirt, breaks it into smaller particles, and pulls it off the floor surface allowing the machine to easily scrub away the suspended soil. The converted water then returns to normal water in the recovery tank. Buffing Pad (Red) -- Used for light duty scrubbing without removing floor finish. Scrubbing Pad (Blue) -- Used for medium to heavy--duty scrubbing. Removes dirt, spills, and scuffs and leaves surface clean ready for recoating. Stripping Pad (Brown) -- Used for stripping of floor finish to prepare the floor for recoating. Heavy Duty Stripping Pad (Black) -- Used for aggressive stripping of heavy finishes/sealers, or very heavy duty scrubbing. MACHINE SETUP ATTACHING SQUEEGEE ASSEMBLY 1. Park the machine on a level surface, remove the key and set the parking brake if equipped. 2. Lift the squeegee lift lever to the upward position (Figure 4). BRUSH AND PAD INFORMATION FIG. 4 For best cleaning results use the appropriate brush type for your cleaning application. Refer to the Parts manual for part number information. 3. Mount the squeegee assembly to the squeegee pivot bracket and secure with knobs (Figure 5). Polypropylene Bristle Scrub Brush (Black) -This general purpose polypropylene bristle scrub brush is used for scrubbing lightly compacted soilage. This brush works well for maintaining concrete, wood and grouted tile floors. Soft Nylon Bristle Scrub Brush (White) -Recommended for cleaning coated floors without removing finish. Cleans without scuffing. Super Abrasive Bristle Scrub Brush (Gray) -Nylon fiber impregnated with abrasive grit to remove stains and soilage. Strong action on any surface. Performs well on buildup, grease, or tire marks. FIG. 5 Polishing Pad (White) -Used to maintain highly polished or burnished floors. Tennant T5 (09--08) Home Find... Go To.. 9 OPERATION 4. Connect the vacuum hose to the squeegee assembly. Loop the hose as shown using the hose clip provided (Figure 6). INSTALLING BRUSHES/PADS FOR SAFETY: Before installing brushes or pad drivers, stop machine on level surface, remove key and set parking brake if equipped. Disk Model: 1. Raise scrub head off the floor and remove key. 2. Attach the pad to the pad driver before installing the driver. Secure pad with centerlock (Figure 9). FIG. 6 5. Check the squeegee blades for proper deflection. The blades should deflect as shown (Figure 7). FIG. 9 3. Align the pad driver under the motor hub and push it upward to engage (Figure 10). FIG. 7 6. To adjust the blade deflection, place the squeegee assembly on a level surface and adjust the casters as shown (Figure 8). FIG. 10 2 mm 1/16” 4. To remove the pad driver, raise the scrub head and push the pad release plunger downward (Figure 11). Lock Nut FIG. 8 FIG. 11 10 Home Find... Go To.. Tennant T5 (09--08) OPERATION 5. Check the scrub head to ensure that it is properly adjusted (See ADJUSTING SCRUB HEAD BRUSHES). Cylindrical Brush Model: 1. Raise scrub head off the floor and remove key. 2. Remove idler plate from scrub head by pressing the spring tab downward (Figure 12). FIG. 12 3. Attach idler plate to the brush end that has the double row of bristles (Figure 13). Install brush. Double row of bristles INSTALLING FaST--PAK CARTON (FaST Model) ATTENTION: The FaST--PAK Concentrate Formula is specifically designed for the FaST system. NEVER use a substitute. Machine damage may result. 1. Pull out the hose connector from the FaST--PAK carton and remove cap (Figure 14). FIG. 14 2. Open the battery compartment. Connect the FaST--PAK carton to the supply hose and place carton in compartment (Figure 15). Make sure the hose does not get pinched. FIG. 13 4. Check the brushes to ensure they are properly adjusted (See ADJUSTING SCRUB HEAD BRUSHES). FIG. 15 3. When the supply hose is not in use, connect the storage plug to prevent the FaST system from drying out and clogging up the hose (Figure 16). FIG. 16 Tennant T5 (06--06) Home Find... Go To.. 11 OPERATION FILLING SOLUTION TANK MACHINE OPERATION Using a hose or bucket, fill the solution tank to the “MAX 85L” mark (Figure 17). For Conventional Scrubbing: Use hot water (140°F/60°C maximum). Pour a recommended cleaning detergent into the solution tank according to mixing instructions on the container. For FaST or ec- H2O Scrubbing: Use cool clean water only (less than 70°F/21°C). Do not add any conventional floor cleaning detergents, system failure may result. FOR SAFETY: Do not operate machine, unless operator manual is read and understood. WARNING: Fire Or Explosion Hazard. Never Operate Machine In Or Near Flammable Liquids, Vapors Or Combustible Dusts. PRE--OPERATION CHECKS - Sweep area. - Check the battery charge level indicator. - Check the brushes/pads for wear. - Check the squeegee blades for wear and proper adjustment. - Make sure the recovery tank is empty and the float shut--off screen is installed and clean. - Check the scrub head skirt for wear. FIG. 17 ATTENTION: For Conventional Scrubbing, only use commercially approved cleaning detergents. Machine damage due to improper detergent usage will void the manufacturer’s warranty. WARNING: Fire or Explosion Hazard. Never Use Flammable Liquids. - For FaST Scrubbing: Check the FaST--PAK concentrate level. - For FaST or ec- H2O Scrubbing: Make sure the solution tank is filled with cool clean water only. - For FaST or ec- H2O Scrubbing: Ensure that all conventional cleaning agents are drained and rinsed from solution tank. STARTING THE MACHINE 1. Release the parking brake if equipped (Figure 18). 2. Turn the key to the on ( I ) position (Figure 18). FIG. 18 3. FaST Model: Press the FaST system switch to the on ( I ) position (Figure 19). ec- H2O Model: Press the ec--H2O system switch to the on ( I ) position (Figure 19). NOTE: The ec--H2O system indicator light will not turn on until the machine starts scrubbing. 12 Home Find... Go To.. Tennant T5 (03--08) OPERATION IMPORTANT: NEVER turn the FaST/ec--H2O system switch on when conventional scrubbing. Conventional cleaning detergents/restorers may cause failure to the FaST/ec--H2O solution system. Drain, rinse and refill solution tank with cool clean water before operating the FaST/ec--H2O system. FIG. 22 7. Adjust the speed control knob to a desired scrubbing speed (Figure 23). NOTE: 148--197 ft (45--60 meters) per minute is the recommended scrubbing speed. FIG. 19 4. Lower the squeegee assembly to floor by lowering the squeegee lift lever (Figure 20). FIG. 23 FIG. 20 5. Press the 1--STEP scrub button (Figure 21). 8. Press the brush pressure and solution flow buttons to increase (+) or decrease (--) as needed (Figure 24). To shut off the solution flow, continue to press the decrease button (--) until the lights turn off. NOTE: For the FaST and ec--H2O models, the solution flow rate is fixed and requires no adjustment. The ec--H2O module has optional flow rate settings. If solution flow adjustments are required, contact an Authorized Service Center. FIG. 21 6. Pull the control handle bail to start scrubbing (Figure 22). To reverse the machine, simply push the control handle bail forward. Raise squeegee when reversing machine. FIG. 24 9. To stop scrubbing, release the control handle bail, press the 1--STEP scrub button and raise the squeegee. Tennant T5 (09--08) Home Find... Go To.. 13 OPERATION EMERGENCY STOPPING Strike the emergency stop button, if equipped, in the event of an emergency (Figure 25). This button shuts off all power to machine. Turn the button clockwise and restart the key to regain power. ATTENTION: (ec- H2O model) Do not allow solution tank to run dry. ec- H2O module failure may result if operated without water for an extended period. FIG. 26 ec- H2O SYSTEM INDICATOR LIGHT CODE CONDITION FIG. 25 WHILE OPERATING MACHINE Solid green Normal operation Blinking red Flush ec--H2O module Solid red Contact Service Center WARNING: Fire Or Explosion Hazard. Do Not Pick Up Flammable Materials Or Reactive Metals. 1. Overlap each scrub path by 2 in (5 cm). BATTERY CHARGE LEVEL INDICATOR 2. Keep the machine moving to prevent damage to floor finish. The battery charge level indicator displays the charge level of the batteries (Figure 27). When the batteries are fully charged, all five indicator lights will glow. As the batteries discharge, the indicator lights will begin to go out from right to left. 3. Do not operate the machine on inclines that exceed 5% (3°). 4. Conventional scrubbing: Pour a commercially approved foam control solution into the recovery tank if excessive foam appears. ATTENTION: Do not allow foam to enter the float shut-off screen, vacuum motor damage will result. Foam will not activate the float shut-off screen. 5. For heavily soiled areas, use the double scrubbing method. First scrub the area with the squeegee up, let solution set for 3--5 minutes, then scrub the area a second time with squeegee down. When the discharge level reaches the red light, the operator will have approximately one minute to continue scrubbing. When the red light begins to flash the scrubbing functions will automatically shut off to alert the operator to recharge the batteries. By pressing the 1--STEP scrub button, when the red light is flashing, the operator will get an additional minute of scrubbing. 6. When leaving the machine unattended, remove the key and set the parking brake, if equipped. 7. If the machine detects a fault, the control panel lights will blink a fault code (See CONTROL PANEL FAULT INDICATOR CODES). 8. ec- H2O Model: If an alarm sounds and the ec--H2O system indicator light begins to blink red, the ec--H2O module must be flushed to resume ec--H2O operation (See ec--H2O MODULE FLUSH PROCEDURE) (Figure 26). NOTE: When the alarm sounds and the light blinks red, the machine will bypass the ec--H2O system. To continue scrubbing, turn the ec--H2O switch off and change over to conventional scrubbing. 14 Home Find... Go To.. FIG. 27 Tennant T5 (09--08) OPERATION 3. Using the hose adapter, connect the squeegee hose to the wand hose (Figure 30). HOUR METER The hour meter records the number of total hours the vacuum and brush motors have been powered on. Use the hour meter to determine when to perform recommended maintenance procedures and to record service history (Figure 28). See MACHINE MAINTENANCE. FIG. 30 4. Attach the off--aisle wand to the hoses (Figure 31). FIG. 28 OFF--AISLE WAND SETUP AND OPERATION If your machine is equipped with the off--aisle wand option, this allows you to scrub areas where the machine is unable to reach. Preparing Machine for Off--Aisle Wand Scrubbing: 1. Park the machine on a level surface, turn key off and set parking brake if equipped. 2. Connect the solution hose to the coupler at the lower right side of machine (Figure 29). FIG. 29 Tennant T5 (09--08) Home FIG. 31 Operating the Off--Aisle Wand: 1. Turn the key and wand switch to the on ( I ) position (Figure 32). The FaST/ec--H2O system switch is disabled when operating the wand. FIG. 32 Find... Go To.. 15 OPERATION 2. Lower the squeegee to activate the vacuum motor (Figure 33). DRAINING AND CLEANING TANKS After each use, the tanks should be drained and cleaned. DRAINING RECOVERY TANK 1. Transport machine to disposal area and turn key switch off. 2. While holding the drain hose upward, remove the cap and lower hose to drain (Figure 35). FIG. 33 3. Squeeze trigger to activate solution. Use brush for scrubbing and squeegee for pickup (Figure 34). FIG. 35 3. After draining, open the recovery tank and clean out the tank (Figure 36). FIG. 34 4. After scrubbing, turn off the wand switch and squeeze the trigger for five seconds to relieve the water pressure before disconnecting the solution hose. WARNING: Fire or Explosion Hazard. Do Not Pick Up Flammable Materials Or Reactive Metals. FIG. 36 4. Clean the float shut-off screen and debris tray located in the recovery tank (Figure 37). FIG. 37 16 Home Find... Go To.. Tennant T5 (09--08) OPERATION DRAINING SOLUTION TANK CHARGING BATTERIES 1. To drain remaining water from the solution tank, pull the solution tank level hose off the hose fitting (Figure 38). ATTENTION: To prolong the life of the batteries only recharge the batteries if the machine was used for a total of 30 minutes or more. Do not leave batteries discharged for lengthy periods. WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. FOR SAFETY: When servicing batteries, wear protective gloves and eye protection when handling batteries and battery cables. Avoid contact with battery acid. FIG. 38 BATTERY CHARGER SPECIFICATIONS: 2. To rinse out the solution tank remove the clean--out cap at the rear of the machine and spray water directly into the clean-out ports (Figure 39). S CHARGER TYPE: -- FOR SEALED (Gel) BATTERIES -- FOR WET (Lead acid) BATTERIES S S S S OUTPUT VOLTAGE - 24 VOLTS OUTPUT CURRENT - 20 AMPS AUTOMATIC SHUTOFF CIRCUIT FOR DEEP CYCLE BATTERY CHARGING ON--BOARD BATTERY CHARGER SETTINGS: If your machine is equipped with the on--board charger, the charger settings must be set for your battery type before charging. Failure to properly set will result in battery damage. FIG. 39 3. Clean the solution tank filter (Figure 40). To determine your battery type, see battery label. Contact your battery supplier if not specified. To verify the setting of the charger, connect the charger cord into an electrical receptacle. The charger will display a sequence of codes. One of the codes will either read “GEL” or “Acd” (Figure 41). GEL = Set for sealed/maintenance free batteries Acd = Set for wet/lead acid batteries FIG. 40 FIG. 41 Tennant T5 (06--06) Home Find... Go To.. 17 OPERATION To change the setting, unplug the charger, peel up the corner of the display label and set the switches accordingly (Fig. 42). The charger cord must be unplugged when resetting. NOTE: The machine will not operate when charging. FIG. 44 SEALED “GEL” BATTERY WET “Acd” BATTERY FIG. 42 USING THE ON--BOARD BATTERY CHARGER IMPORTANT: Before charging, make sure that the charger setting is properly set for your battery type (See ON--BOARD CHARGER SETTINGS). 6. The charger will display a sequence of codes once the cord is connected (Figure 45). Three--digits + the following code: A = Charging current U = Battery Voltage h = Charging time C = Charging ampere--hours [Ah] E = Energy used [Kwh] “GEL” or “Acd” = Battery type the charger is currently set for. Before charging make sure your battery type matches the display: GEL=Sealed, Acd=WET (lead acid). To change setting, see ON--BOARD CHARGER SETTINGS. Press the arrow button to review the codes. 1. Transport the machine to a well--ventilated area. 2. Park the machine on a flat, dry surface. Turn the key off and set the parking brake, if equipped. 3. If charging wet (lead acid) batteries check the fluid level before charging (See BATTERY MAINTENANCE). 4. Prop up the recovery tank for ventilation (Figure 43). FIG. 45 7. Once the charging cycle begins, the indicator lights will progress from red, yellow to green. When the green indicator light comes on, the charging cycle is done. Unplug the charger cord. If the charger detects a problem, the charger will display an error code (See ON--BOARD BATTERY CHARGER ERROR CODES). FIG. 43 5. Connect the charger’s AC power supply cord into a properly grounded receptacle (Figure 44). 18 Home Find... Go To.. Tennant T5 (09--06) OPERATION ON--BOARD BATTERY CHARGER ERROR CODES DISPLAY CODE FAULT SOLUTION bat Loose or damaged battery cable Check battery cable connections. Battery exceeded maximum voltage level. No action necessary. E01 Exceeded maximum battery voltage allowed. No action necessary. E02 Safety thermostat exceeded maximum internal Check if the charger vents are obstructed. temperature. E03 Exceeded maximum time for charging phase leaving the batteries undercharged due to a sulfated or faulty battery. Repeat the charging cycle and if the error code E03 reappears check battery or replace it. SCt Safety timer exceeded maximum charging time. Interrupts charging cycle. Replace battery. Srt Possible internal short circuit. Contact Service Center. Tennant T5 (06--07) Home Find... Go To.. 19 OPERATION ON--BOARD CHARGER FUSE REPLACEMENT The on--board charger is protected by a 15 Amp fuse. To replace a blown fuse, follow the instructions as described below. Required Fuse: 15 Amp (part no. 1030692). Never substitute a higher Amp rated fuse than specified. 1. Unplug the charger’s AC power supply cord before replacing the fuse. WARNING: Electrical Hazard, Unplug Charger Plug Before Servicing Machine. 2. To access the on--board charger fuse, the machine’s left side panel must be removed. To remove the side panel: a. Lift the recovery tank to access the side panel mounting screws. Make sure the tank is empty. b. Remove the 3 mounting screws as shown (Figure 46). 3 Mounting Screws FIG. 48 USING AN OFF--BOARD BATTERY CHARGER (OPTION) 1. Transport the machine to a well--ventilated area. 2. Park the machine on a flat, dry surface. Turn the key off and set the parking brake, if equipped. 3. If charging wet (lead acid) batteries, check the fluid level before charging (See BATTERY MAINTENANCE). 4. Prop up the recovery tank for ventilation (Figure 49). FIG. 46 c. Lower the recovery tank and pry out the top left edge of the panel to remove (Figure 47). FIG. 49 5. Connect the charger’s AC power supply cord into a properly grounded receptacle. 6. Connect the charger’s DC cord into the machine’s battery receptacle (Figure 50). FIG. 47 3. The fuse holder is located at the bottom of the charger. Use a screwdriver to access the fuse (Figure 48). FIG. 50 20 Home Find... Go To.. Tennant T5 (01--07) OPERATION 7. The supplied charger will automatically begin charging and shut off when fully charged. NOTE: The machine will not operate when charging. ATTENTION: Do not disconnect the charger’s DC cord from the machine’s receptacle when the charger is operating. Arcing may result. If the charger must be interrupted during charging, disconnect the AC power supply cord first. Lock Nut ADJUSTING SCRUB HEAD BRUSHES FIG. 52 To ensure optimum scrubbing performance periodically check the scrub head for proper adjustment. FOR SAFETY: Before adjusting scrub head, stop machine on level surface, remove key and set parking brake if equipped. DISK MODEL CYLINDRICAL BRUSH MODEL After installing a new set of cylindrical brushes check the brush pattern to ensure proper brush adjustment. Brushes that are not properly adjusted will result in premature wear and poor scrubbing performance (Figure 53). Tools required: Measuring device, 1--1/16 in (27mm) wrench and 15/16 in (24mm) wrench CORRECT BRUSH PATTERN Even Pattern 1. With brushes installed, lower the scrub head and apply medium brush pressure. 2. Turn machine off and remove key. 3. From the center front and back of scrub head, measure the distance from the top edge of scrub head to the floor (Figure 51). Uneven Pattern INCORRECT BRUSH PATTERNS Tapered Pattern FIG. 53 To Inspect the Brush Pattern: 1. Position the machine on a dry dusty floor or apply a powdered substance, such as chalk. 2. Disconnect the drive motor wire connector to keep machine from moving forward (Figure 54). FIG. 51 4. If scrub head is not level, loosen the lock nut and turn the scrub head leveling screw to level. Tighten down the lock nut once head is level (Figure 52). FIG. 54 Tennant T5 (01--07) Home Find... Go To.. 21 OPERATION 3. Lower the scrub head to the floor and apply maximum brush pressure. To Adjust a Tapered Brush Pattern: 4. Shut off the solution flow. Tools required: 3/8 in (10mm) wrench and 6mm hex wrench 5. Pull the control handle bail to create a brush pattern on the floor. 1. Raise the scrub head off floor and remove key. 6. Raise the scrub head and pull the machine away. 2. Remove the idler plate from the brush (Figure 57). 7. Observe the brush pattern on floor. If the brush pattern is uneven or tapered, adjustment is required. 8. Reconnect drive motor wire. To Adjust an Uneven Brush Pattern: Tools required: Measuring device, 1--1/16 in (27mm) wrench and 15/16 in (24mm) wrench 1. Measure the distance from the front edge of the scrub head to the floor and from the back edge of the scrub head to the floor (Figure 55). The measurements should be the same. FIG. 57 3. Hold the brush plug shaft with a wrench and loosen the 6mm hex screw (Figure 58). FIG. 55 2. To level the scrub head, loosen the lock nut and turn the leveling screw clockwise to lower the rear of the scrub head or counter--clockwise to lower the front (Figure 56). FIG. 58 4. To lower the brush end, turn the shaft clockwise for the front brush and counter--clockwise for the rear brush. Retighten hex screw (Figure 59). FIG. 56 3. Recheck brush pattern. FIG. 59 NOTE: Replace brushes when worn to 5/8” (15mm). 5. Recheck brush pattern. NOTE: Replace brushes when worn to 5/8” (15mm). 22 Home Find... Go To.. Tennant T5 (01--07) OPERATION 4. Remove the debris tray and empty (Figure 63) MACHINE MAINTENANCE To keep the machine in good working condition, it’s important that the following maintenance procedures are performed on a routine basis. WARNING: Electrical Hazard. Disconnect Battery Cables Before Servicing Machine. DAILY MAINTENANCE (After Every Use) 1. Drain the recovery tank (Figure 60). FIG. 63 5. Drain the solution tank (Figure 64). FIG. 60 2. Rinse and clean out the recovery tank (Figure 61). FIG. 64 6 Clean the solution tank filter (Figure 65). FIG. 61 3. Remove the recovery tank float shut--off screen and clean (Figure 62). FIG. 65 7. Rotate pad or replace when worn (Figure 66). Disk Model FIG. 62 Tennant T5 (01--07) Home FIG. 66 Find... Go To.. 23 OPERATION 8. Empty and rinse out the debris trough (Figure 67). 11. Wipe the squeegee blades clean (Figure 70). Store the squeegee assembly in the raised position to prevent blade damage. Cylindrical Brush Model FIG. 67 9. Inspect the cylindrical brushes for wear. Rotate brushes from front--to--rear every 50 hours (Figure 68). Replace when worn to a length of 5/8” (15mm). FIG. 70 12. Check the condition of the squeegee blade wiping edge (Figure 71). Rotate blade if worn (See SQUEEGEE BLADES). 5/8” (15mm) Cylindrical Brush Model FIG. 68 10. Remove debris buildup from the underside of the cylindrical brush scrub head, including the idler plates and drive hubs (Figure 69). FIG. 71 13. Clean the machine with an all purpose cleaner and damp cloth (Figure 72). FOR SAFETY: When cleaning machine, do not power spray or hose off machine. Electrical malfunction may occur. Cylindrical Brush Model FIG. 69 FIG. 72 24 Home Find... Go To.. Tennant T5 (01--07) OPERATION 14. Inspect the condition of the scrub head skirt, replace if worn or damaged (Figure 73). MONTHLY MAINTENANCE 1. Periodically check the belt tension on the two brush motors. Tighten the belt if you’re able to twist it beyond 90_ at midpoint (Figure 76). WARNING: Electrical Hazard. Disconnect Battery Cables Before Servicing Machine. Disk Model Cylindrical Brush Model FIG. 73 15. FaST Model: Connect the FaST--PAK supply hose to the storage plug when not in use (Figure 74). Remove any dried concentrate from the hose connector by soaking it in warm water. Cylindrical Brush Model FIG. 76 2. Inspect and clean the recovery tank cover seal (Figure 77). Replace if damaged. FIG. 74 16. Clean wet/lead acid batteries to prevent corrosion and check for loose battery cable connections (See BATTERY MAINTENANCE). 17. Recharge the batteries (Figure 75). To prolong the life of the batteries, only recharge the batteries if the machine was used for a total of 30 minutes or more. FIG. 77 3. Lubricate all pivot points and rollers with a water resistant grease. 4. Lubricate the casters with a water resistant grease (Figure 78). FIG. 75 FIG. 78 Tennant T5 (06--07) Home Find... Go To.. 25 OPERATION 5. Clean the parking brake clamp with a cleaning solvent. 6. Check the machine for loose nuts and bolts. 7. Check the machine for leaks. BATTERY MAINTENANCE (Wet/lead acid batteries) 1. Check battery fluid level frequently to prevent battery damage. The fluid should be at the level shown (Figure 79). Add distilled water if low. DO NOT OVERFILL, the fluid may expand and overflow when charging. FIG. 80 SQUEEGEE BLADES When the blades become worn, simply rotate the blades end-for-end or top-to-bottom to a new wiping edge. Replace blades when all edges are worn. The front blades on the 700mm/800mm squeegee assemblies have 12/14 slots on one edge and 6 slots on the opposite edge (Figure 81). If making sharp turns with the cylindrical brush models use the 12/14 slotted edge for maximum water pickup. 6 Slots on one edge CORRECT BATTERY FLUID LEVEL: Before Charging After Charging 12/14 Slots on opposite edge FIG. 79 FIG. 81 WARNING: Fire Or Explosion Hazard. Batteries Emit Hydrogen Gas. Keep Sparks And Open Flame Away. Keep Battery Compartment Open When Charging. Replacing Squeegee Blades: 1. Loosen the band clamp and remove the band from the squeegee assembly (Figure 82). 2. Clean the batteries to prevent battery corrosion. Use a scrub brush with a mixture of baking soda and water (Figure 80). FOR SAFETY: When cleaning batteries, wear protective gloves and eye protection. Avoid contact with battery acid. FIG. 82 26 Home Find... Go To.. Tennant T5 (01--07) OPERATION 2. Replace or rotate the rear blade to a new wiping edge and replace band (Figure 83). FaST SYSTEM MAINTENANCE Every 1000 hours replace the water filter and air filter located in the FaST detergent injector. Order filter kit p/n 9003009. 1. To access the detergent injector assembly, lower the scrub head and remove the front cover (Figure 85). FIG. 83 3. To change the front blade, remove the band and loosen the four knobs. Replace or rotate the front blade to a new wiping edge (Figure 84) FIG. 85 2. Remove the injector assembly from clamps (Figure 86). FIG. 84 MOTOR MAINTENANCE Contact an Authorized Service Center for carbon brush replacement. FIG. 86 Carbon Brush Replacement Hours Drive Transaxle Motor Vacuum Motor 3. Replace the water and air filter. An 8mm hex wrench is required to install the new water filter (Figure 87). 750 Water Filter Disk Brush Motors (50 Mesh/Brown) Cylindrical Brush Motors 1000 WARNING: Electrical Hazard. Disconnect Battery Cables Before Servicing Machine. Air Filter (50 Mesh/Brown) FIG. 87 Tennant T5 (03--08) Home Find... Go To.. 27 OPERATION ec- H2O MODULE FLUSH PROCEDURE This procedure is only required when an alarm sounds and the ec--H2O system indicator light begins to blink red. 1. Drain the solution tank and recovery tank of all water. 5. Press and release the ec--H2O module flush switch to start the flush cycle (Figure 89). The module is located under the recovery tank. NOTE: The module will automatically shut off when the flush cycle is complete (approx. 7 minutes). The module must run the full 7 minute cycle in order to reset the system indicator light and alarm. Repeat flush procedure if the ec--H2O module does not reset. If module fails to reset, contact an Authorized Service Center. 2. Pour 1 gallon (4 liters) of white or rice vinegar into the solution tank at full strength. Do not dilute. NOTE: Use white or rice vinegar only. The acidity level should be between 4--8%. Do not use other acids for this procedure. FOR SAFETY: When servicing machine, wear protective gloves and eye protection when handling vinegar. 3. Disconnect the black connector fitting at the scrub head and place the hose into a bucket (Figure 88). To access the connector fitting, you may have to remove the front cover from the machine. FIG. 89 JACKING UP MACHINE Use the designated locations to jack up the machine for service (Figure 90). Empty the recovery and solution tank and position the machine on a level before jacking. FIG. 88 FOR SAFETY: When servicing machine, jack machine up at designated locations only. Use jack or hoist that will support machine weight. 4. Turn the key to the on ( I ) position. FIG. 90 28 Home Find... Go To.. Tennant T5 (11--08) OPERATION FREEZE PROTECTION TRANSPORTING MACHINE When transporting the machine by trailer or truck, be certain to follow the transporting procedure below: 1. Drain machine tanks. 2. Load the machine using a ramp that can support the machine weight and person loading it. The maximum ramp incline should not exceed 11° at a ramp length of 12 ft (3.7m). 3. Position the front of machine up against the front of the trailer or truck. Lower the scrub head and squeegee. 4. Set the parking brake, if equipped, and place a block behind each wheel to prevent the machine from rolling. 5. Secure with tie--down straps as shown (Figure 91). It may be necessary to install tie-down brackets to trailer or truck. FOR SAFETY: When loading/unloading machine onto/off truck or trailer, use a ramp that can support the machine weight and person loading it, do not exceed a 11° ramp incline at a ramp length of 12 ft (3.7m), use tie--down straps to secure machine and block machine wheels. 1. Drain the solution tank and recovery tank of all water. 2. Pour 1 gallon (4 liters) of recreational vehicle (RV) antifreeze into the solution tank at full strength. Do not dilute. FOR SAFETY: Avoid eye contact with antifreeze. Wear safety glasses. 3. Turn the machine power on and operate the solution flow system. Turn the machine off when the red RV antifreeze is visible. If your machine is equipped with the off--aisle wand option, operate the off--aisle wand for a few seconds to protect the pump. Continue with the freeze protection procedure if machine is equipped with the FaST or ec--H2O system. ec- H2O Model: Press and release the flush switch on the ec--H2O module to cycle the antifreeze through ec--H2O system (Figure 92). When the antifreeze is visible, press the switch again to turn off the module. NEW PHOTOS FIG. 92 IMPORTANT: Before operating machine, the antifreeze must be flushed from the module as described below. FIG. 91 STORING MACHINE 1. Charge the batteries before storing machine to prolong the life of the batteries. 2. Drain and rinse the tanks thoroughly. 3. Store the machine in a dry area with the squeegee and scrub head in the up position. 4. Open the recovery tank cover to promote air circulation. If the antifreeze is not properly flushed from the ec--H2O system, the ec--H2O module may detect an error and not function (ec--H2O switch indicator light will turn red). If this occurs, reset key and repeat the flush procedure as described below. Flushing antifreeze from ec- H2O module: 1. Drain the antifreeze from the solution tank into a bucket. 2. Fill the solution tank with cool water until full (See FILLING SOLUTION TANK). ATTENTION: Do not expose machine to rain, store indoors. 5. If storing machine in freezing temperatures, follow the FREEZE PROTECTION instructions below. Tennant T5 (09--08) Home Find... Go To.. 29 OPERATION 3. Disconnect the black connector fitting at the scrub head and place the hose into a bucket (Figure 93). To access the connector fitting, you may have to remove the front cover from the machine. FIG. 95 3. Pour the recreational vehicle (RV) antifreeze into the supply hose until full (Figure 96). FIG. 93 4. Press and release the ec--H2O module switch to flush the antifreeze from the ec--H2O system (Figure 92). The module is located under the recovery tank. 4. Keep the hose upright to prevent the antifreeze from spilling and lower the recovery tank. When the water turns clear, press the module switch again to stop the flush cycle. Dispose the antifreeze in an environmentally safe way according to local waste disposal regulations. 5. The machine is now ready for scrubbing. FaST Model: The following items are required: valve coupling #1002856 and 6 in (15 cm) hose #63182. 1. Remove the FaST--PAK carton and connect the valve coupling and 6 in (15 cm) hose to the FaST detergent supply hose (Figure 94). FIG. 96 5. Operate the FaST system until the foaming stops. This step could take anywhere from 5 to 10 minutes. 6. When finished, connect the supply hose to the storage plug (Figure 97). FIG. 94 2. Disconnect the opposite end of the FaST supply hose from the injector assembly and drain the detergent from the hose (Figure 95). Reconnect the hose after draining. To access the injector assembly remove the front cover. 30 Home FIG. 97 10. To drain the antifreeze from the FaST supply hose, repeat steps 1 and 2. Find... Go To.. Tennant T5 (09--08) OPERATION RECOMMENDED STOCK ITEMS Refer to the Parts List Manual for recommended stock items. Stock Items are clearly identified with a bullet preceding the parts description. See example below: TROUBLESHOOTING PROBLEM CAUSE SOLUTION Machine will not operate Discharged batteries Charge batteries Emergency--stop button activated Turn button clockwise to reset Faulty battery(s) Replace battery(s) Loose battery cable Tighten loose cable Faulty control board Contact Service Center Faulty key switch Contact Service Center Machine fault detected. See Contol Panel Fault Indicator Codes Plug not connected to power supply Check plug connection Faulty charger fuse Replace charger fuse Faulty power supply cord Replace cord Error detected. See On--board Battery Charger Error Codes 1--STEP scrub button is off Turn on the 1--STEP scrub button Brush motor overload See Control Panel Fault Indicator Codes Discharged batteries Charge batteries Faulty control board Contact Service Center Faulty scrub head (up/down) switch Contact Service Center Faulty control handle bail switch Contact Service Center Faulty brush motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Broken or loose belt (cylindrical brush model) Replace or tighten belt Parking brake is set Release parking brake lever Machine fault detected See Control Panel Fault Indicator Codes Faulty control board Contact Service Center Wheels raised off floor Contact Service Center Faulty transaxle motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Exceeded maximum incline Avoid steep inclines and reset key Squeegee is raised off floor Lower squeegee Onboard battery charger will not operate Brush motor(s) will not operate Machine will not propel Vacuum motor will not operate Tennant T5 (11--08) Home Find... Go To.. 31 OPERATION TROUBLESHOOTING - Continued PROBLEM CAUSE SOLUTION Vacuum motor will not operate Discharged batteries Charge batteries Faulty control board Contact Service Center Faulty vacuum motor or wiring Contact Service Center Worn carbon brushes Contact Service Center Solution tank is empty Fill solution tank Clogged solution tank filter Clean solution tank filter Discharged batteries Charge batteries Clogged solution valve Remove valve and clean Faulty control board Contact Service Center Recovery tank is full or excessive foam buildup Drain recovery tank Loose drain hose cap Tighten cap Clogged float shut--off screen located in recovery tank Clean screen Clogged squeegee assembly Clean squeegee assembly Worn squeegee blades Replace or rotate squeegee blades Incorrect Squeegee blade deflection Adjust Squeegee blade height Loose vacuum hose connections Secure hose connections Clogged vacuum hose Remove clogged debris Damaged vacuum hose Replace vacuum hose Recovery tank cover not in place Properly position cover Damaged recovery tank cover seal Replace seal Faulty vacuum motor Contact Service Center Debris caught in brush Remove debris Worn brushes/pads Replace brushes/pads Incorrect brush pressure setting Adjust pressure setting Wrong brush/pad type. Use correct brush/pad Batteries not fully charged Fully recharge batteries Defective batteries Replace battery Batteries need maintenance See BATTERY MAINTENANCE Faulty battery charger Repair or replace battery charger Supervisor controls are activated (lockout feature) Contact your Supervisor Little or no solution flow Poor water pickup Poor scrubbing performance Reduced run time Solution flow and brush pressure buttons and FaST system switch are locked 32 Home Find... Go To.. Tennant T5 (06--06) OPERATION TROUBLESHOOTING - Continued PROBLEM CAUSE SOLUTION FaST Model: FaST System does not operate or operate correctly FaST system switch is not turned on Turn on FaST system switch FaST--PAK supply hose not connected Connect supply hose Clogged FaST--PAK supply hose or connectors Soak in warm water to unclog Empty FaST--PAK carton Replace FaST--PAK carton Kink in FaST--PAK supply hose Undo hose kink Clogged FaST solution system Contact Service Center Faulty FaST system on/off switch Contact Service Center Faulty pump Contact Service Center Clogged solution tank filter Drain solution tank. Remove solution tank filter, clean and reinstall Clogged detergent orifice/filter screen Replace orifice/filter screen (See FaST SYSTEM MAINTENANCE) Clogged FaST solution inlet filter Contact Service Center Faulty control board Contact Service Center Mineral deposit build--up in module Flush module (See ec--H2O MODULE FLUSH PROCEDURE) ec- H2O Model: ec--H2O system indicator light solid red Defective module Contact Service Center ec- H2O Model: ec--H2O system indicator light does not turn on Defective light or module Contact Service Center ec- H2O Model: No water flow Clogged module Contact Service Center Defective solution pump Replace solution pump ec- H2O Model: ec--H2O system indicator light blinking red ec- H2O Model: Alarm Sounds Tennant T5 (09--08) Home Find... Go To.. 33 OPERATION CONTROL PANEL FAULT INDICATOR CODES The control panel fault indicator lights will display the following codes when the machine detects a fault. Light #4 Light #1 Light #2 Light #3 Battery Lights CODE FAULT SOLUTION Light #1 blinks Recovery tank is raised. Lower recovery tank. Restart key to reset. Lights #1, #2 and #3 ripple Battery charger connected. Disconnect battery charger. Restart key to reset. Lights #1 and #4 blink Left Brush motor overload. Inspect brush for entangled debris, improper pad or contact service center. Restart key to reset. Lights #3 and #4 blink Right Brush motor overload. Inspect brush for entangled debris, improper pad or contact service center. Restart key to reset. Lights #2 and #3 blink Propel motor overload. Exceeded maximum incline. Avoid steep inclines or contact service center. Restart key to reset. Lights #1 and #3 blink Scrub head movement is obstructed or actuator motor malfunction. Check scrub head for obstruction or contact service center. Restart key to reset. Light #2 blinks Vacuum motor malfunction. Contact service center. Lights #1 and #2 blink Propel throttle malfunction. Contact service center. Light #3 blinks FaST pump overload or malfunction. Reset the 10A circuit breaker or contact service center. Restart key to reset. Light #3 blinks when pressing the solution flow, brush pressure buttons and FaST system switch Supervisor controls activated (lockout feature) Contact your Supervisor. Lights #1, #2 and #3 blink Wand Pump overload or malfunction. Reset the 10A circuit breaker button or contact service center. Restart key to reset. All battery lights blink Emergency--Stop button activated Turn button clockwise to reset. All battery lights ripple Key turned on while bail was engaged. Release the control handle start bail. 34 Home Find... Go To.. Tennant T5 (06--06) OPERATION MACHINE SPECIFICATIONS MODEL Disk, 600 mm Disk, 700 mm Disk, 800 mm LENGTH 53 in / 1,346 mm Cylindrical, 650 mm Cylindrical, 800 mm 55.1 in / 1,400 mm 57.6 in / 1,463 mm 54.6 in / 1,387 mm 54.6 in / 1,387 mm WIDTH 25.4 in / 645 mm 29 in / 737 mm 33 in / 838 mm 28 in / 711 mm 34 in / 864 mm MINIMUM AISLE TURN 53 in / 1,346 mm 59 in / 1,499 mm 64 in / 1,626 mm 62 in / 1,575 mm 64.5 in / 1,638 mm WEIGHT 316 lb / 143 kg 365 lb / 166 kg 377 lb / 171 kg 357 lb / 162 kg 365 lb / 166 kg WEIGHT WITH BATTERIES 580 lb / 263 kg 609 lb / 276 kg 621 lb / 282 kg 621 lb / 282 kg 629 lb / 285 kg 44 in / 1,120 mm HEIGHT RECOVERY TANK CAPACITY 27 gal / 102 L SOLUTION TANK CAPACITY 22.5 gal / 85 L Transaxle, 24 V, .25 hp / .19 kW DRIVE SYSTEM Cleaning: 220 ft / 67 m/min TRAVEL SPEED, MAXIMUM Transporting: 235 ft / 72 m/min PRODUCTIVITY RATE Theoretical 26,400 ft2 / 2,450 m2 h 30,800 ft2 / 2,860 m2 h 35,200 ft2 / 3,270 m2 h 28,600 ft2 / 2,660 m2 h 35,200 ft2 / 3,270 m2 h PRODUCTIVITY RATE Estimated Actual 17,875 ft2 / 1,660 m2 h 20,800 ft2 / 1,930 m2 h 24,000 ft2 / 2,230 m2 h 19,200 ft2 / 1,785 m2 h 24,000 ft2 / 2,230 m2 h CLEANING PATH WIDTH 24 in / 600 mm 28 in / 700 mm 32 in / 800 mm 26 in / 650 mm 32 in / 800 mm BRUSH DIAMETER 11.9 in / 302 mm 13.9 in / 353 mm 15.9 in / 404 mm 5.9 in / 151 mm 5.9 in / 151 mm 40 lb / 18 kg, 80 lb / 36 kg, 120 lb / 54 kg BRUSH PRESSURE SOLUTION FLOW RATE -- Max: .45 gpm / 1.70 L/min .50 gpm / 1.90 L/min .45 gpm / 1.70 L/min .50 gpm / 1.90 L/min SOLUTION FLOW RATE -- Med: .35 gpm / 1.30 L/min .40 gpm / 1.51 L/min .35 gpm / 1.30 L/min .40 gpm / 1.51 L/min SOLUTION FLOW RATE -- Low: .25 gpm / .95 L/min .30 gpm/ 1.14 L/min .25 gpm/ .95 L/min .30 gpm / 1.14 L/min SQUEEGEE WIDTH 35.7 in / 908 mm standard 41.3 in / 1,051 mm standard 46.6 in / 1,185 mm standard 41.3 in / 1,051 mm standard 46.6 in / 1,185 mm standard 31.5 in / 800 mm narrow aisle 35.7 in / 908 mm narrow aisle 41.3 in / 1,051 mm narrow aisle 35.7 in / 908 mm narrow aisle 41.3 in / 1,051 mm narrow aisle Qty 2, .75 hp / .55 kW, 220 rpm, 24 V, 29 A BRUSH MOTOR Qty 2, .63 hp / .47 kW , 1,500 rpm, 24 V, 23 A VACUUM MOTOR .85 hp / 640 W, 3--stage 5.7, 24 V, 26 A WATER LIFT/AIR FLOW 62 in / 55 mm -- H2O 69 ft3 / 32.4 L3/min Qty 4, 6 V BATTERIES WET (lead Acid) = 235 Ah @ 20 h rate BATTERY CAPACITY Sealed (Gel)= 200 Ah @ 20 h rate WET = 5.5 h / Gel = 4.5 h RUN TIME PER CHARGE* 120VAC, 10 A, 50/60 Hz, 24VDC, 20 A output / 230VAC, 5 A, 50/60 Hz, 24VDC, 20 A output ONBOARD CHARGER 50 Amp nominal TOTAL POWER CONSUMPTION 24 VDC VOLTAGE DC IPX3 PROTECTION GRADE DECIBEL RATING AT OPERATOR’S EAR, INDOORS.** VIBRATION AT CONTROLS 67dB(A) 68dB(A) <.39 ft/s2 / <.1188 m/s2 <.34 ft/s2 / <.103 m/s2 ACCELERATION RATE ON OPERATOR -- MAX. .56 ft/s2 / .179 m/s2 Scrubbing 5% (3°), Transporting 8% (5°) GRADE LEVEL, MAX. * Run times are based on Continuous Scrubbing Run Times. ** Sound pressure (ISO 11201) as recommended by the American Association of Cleaning Equipment Manufacturers (AACEM) and OSHA. Tennant T5 (06--07) Home Find... Go To.. 35 OPERATION FaST SYSTEM Disk, 600 mm Disk, 700 mm 22,750 ft2 / 2,115 m2 h Disk, 800 mm 20,075 ft2 / 1,865 m2 h SOLUTION PUMP 24 Volt DC, 3.5 A, 1.5 gpm / 5.6L/min open flow, 60 psi / 4.13 bar bypass setting SOLUTION FLOW RATE 0.15 gpm / 0.57 L/min 0.22 gpm / 0.83 L/min 0.15 gpm / 0.57 L/min 0.22 gpm / 0.83 L/min CONCENTRATE FLOW RATE 0.0193 oz / 0.57 cc/min 0.028 oz / 0.83 cc/min 0.0193 oz / 0.57 cc/min 0.028 oz / 0.83 cc/min Cylindrical, 650 mm Cylindrical, 800 mm ec- H2O SYSTEM 21,000 ft2 / 1,950 m2 h Cylindrical, 800 mm PRODUCTIVITY RATE Estimated Actual CONCENTRATE TO WATER DILUTION RATIO 26,250 ft2 / 2,440 m2 h Cylindrical, 650 mm 26,250 ft2 / 2,440 m2 h 1:1000 Disk, 600 mm Disk, 700 mm 22,750 ft2 / 2,115 m2 h Disk, 800 mm PRODUCTIVITY RATE Estimated Actual 20,075 ft2 / 1,865 m2 h 26,250 ft2 / 2,440 m2 h 21,000 ft2 / 1,950 m2 h 26,250 ft2 / 2,440 m2 h SOLUTION PUMP 24 Volt DC, 3.5 A, 1.5 gpm / 5.6L/min open flow, 60 psi / 4.13 bar bypass setting SOLUTION FLOW RATE * 0.15 gpm / 0.57 L/min (standard) 0.22 gpm / 0.83 L/min (standard) 0.22 gpm / 0.83 L/min (standard) 0.33 gpm / 1.25 L/min (standard) 0.22 gpm / 0.83 L/min (optional) 0.33 gpm / 1.25 L/min (optional) 0.30 gpm / 1.14 L/min (optional) 0.44 gpm / 1.67 L/min (optional) 0.30 gpm / 1.14 L/min (optional) 0.44 gpm / 1.67 L/min (optional) * If the optional solution flow rates are required, contact an Authorized Service Center. 36 Home Find... Go To.. Tennant T5 (09--08) OPERATION MACHINE DIMENSIONS 44.1 in / 1,120 mm B A C Models: A= B= C= 600 mm Disk 700 mm Disk 800 mm Disk 650 mm Cylindrical 800 mm Cylindrical 53 in / 1,346 mm 25.4 in / 645 mm 35.7 in / 908 mm 55.1 in / 1,400 mm 29 in / 737 mm 41.3 in / 1,051 mm 57.6 in / 1,463 mm 33 in / 838 mm 46.6 in / 1,185 mm 54.6 in / 1,387 mm 28 in / 711 mm 41.3 in / 1,051 mm 54.6 in / 1,387 mm 34 in / 864 mm 46.6 in / 1,185 mm Tennant T5 (06--07) Home Find... Go To.. 37
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:12:03 11:44:14-05:00 Create Date : 2008:11:26 08:27:33-05:00 Metadata Date : 2008:12:03 11:44:14-05:00 Format : application/pdf Title : Tennant T5 English Operator Manual Creator : jps Document ID : uuid:8c1364e7-82ea-4ff2-9b23-8e57729e4538 Instance ID : uuid:effbcbea-d621-47aa-aed0-ffd9c04c3805 Has XFA : No Page Count : 37 Page Layout : SinglePage Author : jps Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools