System Electronics ISE-400-DLN ELECTRONIC BALLAST ISE-400-DLN; ISE-600-DLN User Manual ISE 400W

Industrial System Electronics Inc. ELECTRONIC BALLAST ISE-400-DLN; ISE-600-DLN ISE 400W

Users Manual

Download: System Electronics ISE-400-DLN ELECTRONIC BALLAST ISE-400-DLN; ISE-600-DLN User Manual ISE  400W
Mirror Download [FCC.gov]System Electronics ISE-400-DLN ELECTRONIC BALLAST ISE-400-DLN; ISE-600-DLN User Manual ISE  400W
Document ID1097244
Application IDvrh3C0WePZ6iHmmBXPyCjw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize5.88kB (73458 bits)
Date Submitted2009-04-15 00:00:00
Date Available2009-04-16 00:00:00
Creation Date2008-11-03 13:30:44
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2008-11-03 13:30:44
Document TitleMicrosoft Word - ISE User Manual_400W.doc
Document CreatorPScript5.dll Version 5.2
Document Author: FA

Industrial System Electronics Inc.
815 – East 13th Ave, Vancouver, BC V5T2L4, Canada
Tel: 778 889 1240; Fax: 928 396 7015, www.iseglobe.com
ISE Electronic Ballast Manual
Model – ISE- 400-DLN
400W
Thank you for purchasing our ballast – Please read this manual carefully before you start to install
the ballast!
Follow the local National Electrical Code. The ballast should be installed by a certified electrician.
Never install the ballast while the power supply is connected.
Package
Use care when you unpacked the ISE Electronic Ballast. Always handle with care. Check the
ballast and the wires to make sure that they have not been damaged during the shipment.
Do not remove any label from the ballast. Read all labels carefully and follow the instructions.
Keep the manual after installation for future reference.
Wire
Because the ballast produces extremely
high voltage you need to use proper cables.
ISE recommends - Silicon isolated
cables – 1.5mm² (AWG #16),
5kV rated or equivalent compatibility.
Socket Wiring
Use sockets that are rated 5kV!
Carefully connect the wires to the socket.
If you use terminals be sure that they
are not close to any metal part of the
socket in order to prevent arcing which
will result in the failure of the bulb to light.
Mounting the Ballast
Attach the ballast tightly to a flat surface.
Allow at least 2”inches (5cm) margin on
every side of the ballast. If the ballast is
installed within a light fixture, place it as
far as possible from the lamp.
Do not install the ballast with the wires
pointing down!!
Industrial System Electronics Inc.
815 – East 13th Ave, Vancouver, BC V5T2L4, Canada
Tel: 778 889 1240; Fax: 928 396 7015, www.iseglobe.com
Dimensions:
Specification:
Model
ISE-400-DLN
Lamps
Sylvania, Philips, GE, HPS&MH
Input
Protections
Input Voltage
120V-240V
Ignition Failure
yes
Frequency
50-60Hz
Open Circuit
yes
Input Current - MAX
3.5A-1.8A
Thermal
yes
Input Power Max.
400W
Short Circuit
yes
Output to ground
Allowed
T.D.H - I
< 8%
Power Factor
> 0.99
Operating Frequency
50 - 150 kHz
Dimensions ( LxWxH )
10"x4.5"x2.5"
Ignition Voltage
<4.5 kV
Dimensions - mm
252x116x64
< 50C
Weight ( Lb/kg )
4.5lb/2.0kg
Max. Allowed Area Temp.
Specification subject to change without notice

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2008:11:03 13:30:44-08:00
Create Date                     : 2008:11:03 13:30:44-08:00
Format                          : application/pdf
Title                           : Microsoft Word - ISE User Manual_400W.doc
Creator                         : FA
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:76ff660f-0a78-4e23-b0a4-910f1717359c
Instance ID                     : uuid:1de78120-1e11-4cfd-abdf-3fb5a3ad4bc1
Page Count                      : 2
Author                          : FA
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WWNISE-400-DLN

Navigation menu