System Level Solutions PI0NL02000100 Nebulae Module V2 User Manual

System Level Solutions (India) Pvt. Ltd. Nebulae Module V2

15_PI0NL02000100 UserMan

Download: System Level Solutions PI0NL02000100 Nebulae Module V2 User Manual
Mirror Download [FCC.gov]System Level Solutions PI0NL02000100 Nebulae Module V2 User Manual
Document ID3939898
Application ID0vb8ybpRCC4WljAyBnBSNA==
Document Description15_PI0NL02000100 UserMan
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize62.61kB (782566 bits)
Date Submitted2018-07-26 00:00:00
Date Available2018-07-26 00:00:00
Creation Date2018-06-15 12:58:40
Producing SoftwareAcrobat Elements 10.0.0 (Windows)
Document Lastmod2018-06-15 13:06:07
Document Titleuntitled
Document CreatorFrameMaker 10.0.2

Nebulae Module V2
Datasheet
System Level Solutions, Inc. (USA)
14100 Murphy Avenue
San Martin, CA 95046
(408) 852 - 0067
http://www.slscorp.com
Module Version:
1C
Document Version:
1.4
Document Date:
June 2018
Copyright ©2018, System Level Solutions, Inc. (SLS) All rights reserved. SLS, an Embedded systems company, the
stylized SLS logo, specific device designations, and all other words and logos that are identified as trademarks and/or
service marks are, unless noted otherwise, the trademarks and service marks of SLS in India and other countries. All other
products or service names are the property of their respective holders. SLS products are protected under numerous U.S.
and foreign patents and pending applications, mask working rights, and copyrights. SLS reserves the right to make
changes to any products and services at any time without notice. SLS assumes no responsibility or liability arising out of
the application or use of any information, products, or service described herein except as expressly agreed to in writing by
SLS. SLS customers are advised to obtain the latest version of specifications before relying on any published information
and before orders for products or services.
ds_nebulaemodule_v2_1.4
System Level Solutions
June 2018
ii
Nebulae Module V2 Datasheet
About this Manual
Revision History
Table below shows the revision history of Nebulae Module V2’s datasheet.
Version
1.4
How to Find
Information
•
•
•
•
How to Contact
SLS
Date
June 2018
Description
•
•
1.3
April 2018
•
Update Figure 1.1 and Table 1.1 in
Chapter 1
1.2
November 2017
•
•
Updated Table 1.1 in Chapter 1
October 2017
Update Figure 1.1 and 1.2 in Chapter 1
1.0
March 2017
First publication
The Adobe Acrobat Find feature allows you to search the contents of a
PDF file. Use Ctrl + F to open the Find dialog box. Use Shift + Ctrl + N
to open to the Go To Page dialog box.
Bookmarks serve as an additional table of contents.
Thumbnail icons, which provide miniature preview of each page,
provides a link to the pages.
Numerous links shown in Navy Blue color allow you to jump to related
information.
For the most up-to-date information about SLS products, go to the SLS
worldwide website at http://www.slscorp.com. For additional information
about SLS products, consult the source shown below
Product literature services, SLS
literature services, Non-technical
customer services, Technical
support.
Nebulae Module V2 Datasheet
Updated Table 2.1 in Chapter 2
1.1
Information Type
iii
Update Table 1.1 in Chapter 1
Added Annexure A: FCC Statement and
Annexure B: Module Statement
E-mail
support@slscorp.com
System Level Solutions
June 2018
Typographic
Conventions
This datasheet uses the typographic conventions as shown below:
Visual Cue
Meaning
Bold Type with Initial Capital
letters
All headings and Sub headings Titles in a document are displayed in
bold type with initial capital letters; Example: General Description,
Features.
Bold Type with Italic Letters
All Definitions, Figure and Table Headings are displayed in Italics.
Examples: Figure 1-1. Nebulae Module V2, Table 1-1. Nebulae
Module V2 Specifications.
1., 2.
Numbered steps are used in a list of items, when the sequence of items
is important. such as steps listed in procedure.
•
Bullets are used in a list of items when the sequence of items is not
important.
The hand points to special information that requires special attention
The caution indicates required information that needs special
consideration and understanding and should be read prior to starting or
continuing with the procedure or process.
The warning indicates information that should be read prior to starting
or continuing the procedure or processes.
The feet direct you to more information on a particular topic.
System Level Solutions
June 2018
iv
Nebulae Module V2 Datasheet
Contents
About this Manual.............................................................................................................. iii
Revision History ......................................................................................................................................iii
How to Find Information .........................................................................................................................iii
How to Contact SLS ................................................................................................................................iii
Typographic Conventions ........................................................................................................................iv
1. Overview .................................................................................................................................... 1
General Description ..................................................................................................................................1
Benefits .....................................................................................................................................................1
Specifications ............................................................................................................................................3
2. Pin-Out Information .................................................................................................................. 6
3. Package Information................................................................................................................. 8
Annexure A: FCC Statement .......................................................................................................... 9
Annexure B: Module Statement .................................................................................................. 11
Nebulae Module V2 Datasheet
System Level Solutions
June 2018
1. Overview
General
Description
The Nebulae Module V2 provides a means for any electronic device to
implement low cost wireless connectivity. This module inter operates with
either Zigbee or 6LoWPAN devices depending on the programmed stack.
Nebulae Module V2 is ideal for applications in the energy and controls
markets where manufacturing efficiencies are critical.
The Nebulae Module V2, built around the NXP JN5169 SoC (system on a
chip) radio IC, integrates an 802.15.4 radio along with a powerful
programmable 32-bit RISC CPU. The architecture isolates the wireless
software without sacrificing RF performance or security for applications.
Quickly and efficiently create customized applications with the Nebulae
Module V2.
Benefits
System Level Solutions
June 2018
The main benefits of the Nebulae Module V2 are:

Customizable Zigbee and 6LoWPAN applications with a programmable
CPU

A rich set of hardware peripherals such as GPIO, UART, SPI, I2C, ADC,
and PWM

A great choice for battery oriented applications with various sleep modes

• Sleep with IO wake up
• RAM Retention
• Low Power mode
• Deep Sleep mode
Provides an OTA (Over the Air) Firmware update mechanism

Supports Mesh networking for both Zigbee and 6LoWPAN

Supports deployment of a dense network with 6LoWPAN
Nebulae Module V2 Datasheet
Benefits
Figure 1-1. shows the Nebulae Module V2.
Figure 1-1. Nebulae Module V2
Figure 1-2. shows Nebulae Module V2 application example.
Nebulae Module V2 Datasheet
System Level Solutions
June 2018
Overview
Figure 1-2. Nebulae Module V2 Application Example
Specifications
Table 1-1 describes specifications of the Nebulae Module V2.
Table 1-1. Nebulae Module V2 Specifications
Performance
Data Rate
Up to 250Kbps
Range
80 Meters Line of Sight (LoS)
TX Current Consumption
23.3mA@ +10dBm; 19.6mA@ +8.5dBm; 14mA @ +3dBm
RX Current Consumption
15mA@ +10dBm; 13mA@ 0dBm
RX Sensitivity
-96 dBm
System Level Solutions
June 2018
Nebulae Module V2 Datasheet
Specifications
Table 1-1. Nebulae Module V2 Specifications
Features
Serial Interface
SPI
1 SPI
3 Selects
I2C
1 Interface
2 Wire
UART
2 UART
Configuration Method
API local and from cloud
Frequency Band
ISM 2.4 GHz
Interference Immunity
DSSS (Direct Sequence Spread Spectrum)
ADC Inputs
Up to 6-input 10-bit
Digital IO
Up to 20
Antenna Options
U.FL Connector
Size (LxWxH in mm)
21.99 x 34 x 3.05
PWM
Up to 5 PWM
4 Timers
1 Counter
Modes
Active
Sleep
Deep Sleep
CPU Processing
1 MHz – 2.5mA
0.6 uA
50 nA
32 MHz – 7.8 mA
Memory
512 kB Flash
32 kB RAM
4 kB EEPROM
Clock/ Speed
1 MHz to 32 MHz
CPU
32 Bit RISC
Programmability
Networking and Security
Protocol
6LoWPAN
Zigbee
Encryption
AES 128 Bit
Reliable Packet Delivery
Retries, Acknowledgements
IDs
PAN ID
Address
IPv6 Address to all nodes
Channels
16
Power Requirement
Supply Voltage
2.0V to 3.6V DC
Temperature
-40 ºC to 125 ºC
Module Software Stack
Zigbee
Nebulae Module V2 Datasheet
Zigbee Pro Stack
System Level Solutions
June 2018
Overview
Table 1-1. Nebulae Module V2 Specifications
6LoWPAN
Nebulae 6LoWPAN Stack
Features :
Three tier security
Time synchronization
Self healing
Remote firmware update
IPv6 enabled full IP networking
Smart network management
Easy network installation and deployment
Supports dense network with flexible routing
Power management, long battery life
Design to withstand failure
Highly scalable network
Module Accessories
Model
TLB-2400-3.0BQ
Manufacturer
Shenzhen Gerbole Elec. Technology Co., Ltd.
Gain
3dBi
Type
Whip-Tilt
Connection Type
RP-SMA
Frequency Range
2400 +/-100
Module to Antenna
Connection Type
U.FL to RP-SMA Cable
System Level Solutions
June 2018
Nebulae Module V2 Datasheet
2. Pin-Out Information
Table 2-1 shows the Nebulae Module V2 Pin-Out.
Table 2-1. Nebulae Module V2 Pin-Out
Pin
No #
Signal Name
Direction
Default
State
Description
GND
Ground
VCC
Power supply
DIO11/PWM1/TXD1
Bidirectional
Output
DIO6/ UART 0 transmit data
output
DIO9/TIM0CAP/32KXTALIN/RXD1/
32KIN(1)
Bidirectional
Input
DIO7/ RXD0 - UART 0
receive data input
DIO16/SPISMOSI/SIF_CLK/COMP1P
Bidirectional
DIO16/ COMP1P comparator plus input
RESET_N
Input
Reset input
DIO8/TIM0CK_GT/PC1/PWM4
Bidirectional
Output
DIO8/RX signal strength
indicator
DIO6/TXD0/JTAG_TDO/PWM2
Bidirectional
DIO11/ PWM1 output
DIO19/SPISEL0
Bidirectional
DIO19/ SPI - bus master
select output 0
10
DIO7/RXD0/JTAG_TDI/PWM3
Bidirectional
Input
DIO9/Pin sleep control line
11
GND
Ground
12
DIO3/RFTX/TIM0CAP/ADC6
Output
Output
DIO3
13
GND
Ground
14
DIO15/SIF_D/RXD0/RXD1/JTAG_TDI/
SPISEL2/SPISCLK
Input
Input
DIO15/ SPI - bus slave
clock input
15
DIO14/SIF_CLK/TXD0/TXD1/
JTAG_TDO/SPISEL1/SPISSEL
Input
Input
DIO14/ SPI - bus slave
select input
16
DIO12/PWM2/CTS0/JTAG_TCK/ADO/
SPISMOSI
Input
Input
DIO12/ SPI - bus slave
master out, slave in input
17
DIO13/PWM3/RTS0/JTAG_TMS/ADE/
SPISMISO
Output
Output
DIO13/ SPI - bus slave
master in slave out output
18
Reserved
Disabled
Do not connect
System Level Solutions
June 2018
Nebulae Module V2 Datasheet
Pin-Out Information
Table 2-1. Nebulae Module V2 Pin-Out
Pin
No #
Signal Name
Direction
Default
State
Description
19
Reserved
Disabled
Do not connect
20
Reserved
Disabled
Do not connect
21
Reserved
Disabled
Do not connect
22
GND
Ground
23
DIO18/SPIMOSI
Bidirectional
DIO18/ SPI - bus master out
slave in output
24
DIO17/SPISMISO/SIF_D/COMP1M/
PWM4
Bidirectional
DIO17/ comparator minus
input
25
DIO4/CTS0/JTAG_TCK/TIM0OUT/
PC0
Bidirectional
Output
DIO4/ UART 0 clear to send
input
26
DIO10/TIM0OUT/32KXTALOUT
Bidirectional
Output
DIO10/Device status
indicator
27
VREF
Input
Analog peripheral
reference voltage/ ADC
input 2
28
DO0/SPICLK/PWM2
Bidirectional
Output
DO0/ SPI - bus master clock
output
29
DIO5/RTS0/JTAG_TMS/PWM1/PC1
Bidirectional
Input
DIO5/ UART 0 request to
send output
30
DIO0/ADO/SPISEL1/ADC3
Bidirectional
DIO0/ ADC input : ADC3
31
DIO1/ADE/SPISEL2/ADC4/PC0
Bidirectional
DIO1/ ADC input : ADC4
32
DIO2/RFRX/TIM0CK_GT/ADC5
Bidirectional
DIO2/ ADC input : ADC5
33
ADC1
Bidirectional
Input
ADC input
34
DO1/SPIMISO/PWM3
Bidirectional
DO1/ SPI - bus master in,
slave out input
35
GND
Ground
36
RF_IO
Bidirectional
RF antenna
37
Reserved
Disabled
Do not connect
Note:
(1)
Default: Pull down
System Level Solutions
June 2018
Nebulae Module V2 Datasheet
3. Package Information
Figure 3-1. shows Physical Dimensions of the Nebulae Module V2.
Figure 3-1. Nebulae Module V2 Physical Dimensions
System Level Solutions
June 2018
Nebulae Module V2 Datasheet
Annexure A: FCC Statement
(OEM) Integrator has to assure compliance of the entire end-product incl. the
integrated RF Module. For 15 B (§15.107 and if applicable §15.107)
compliance, the host manufacturer is required to show compliance with 15
while the module is installed and operating.
Furthermore the module should be transmitting and the evaluation should
confirm that the module's intentional emissions (15C) are compliant
(fundamental / out-of-band). Finally the integrator has to apply the
appropriate equipment authorization (e.g. Verification) for the new host
device per definition in §15.101.
Integrator is reminded to assure that these installation instructions will not be
made available to the end-user of the final host device.
The final host device, into which this RF Module is “integrated” has to be
labelled with an auxilliary label stating the FCC ID of the RF Module, such
as “Contains FCC ID:2AO93PI0NL02000100”
“This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference that may cause undesired operation.”
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
System Level Solutions
June 2018
Nebulae Module V2 Datasheet
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for
help.
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user's authority to operate the
equipment.
10
Nebulae Module V2 Datasheet
System Level Solutions
June 2018
Annexure B: Module Statement
The single-modular transmitter is a self-contained, physically delineated,
component for which compliance can be demonstrated independent of the
host operating conditions, and which complies with all eight requirements of
§ 15.212(a)(1) as summarized below.
3). The radio elements have the radio frequency circuitry shielded.
4). The module has buffered modulation/data inputs to ensure that the
device will comply with Part 15 requirements with any type of
input signal.
5). The module contains power supply regulation on the module.
6). The module contains a permanently attached antenna.
7). The module demonstrates compliance in a stand-alone configuration.
8). The module is labeled with its permanently affixed FCC ID label
9). The module complies with all specific rules applicable to the transmitter, including all the conditions provided in the integration
instructions by the grantee.
10). The module complies with RF exposure requirements.
This transmitter/module must not be collocated or operating in conjunction
with any other antenna or transmitter.
System Level Solutions
June 2018
11
Nebulae Module V2 Datasheet

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2018:06:15 12:58:40Z
Creator                         : FrameMaker 10.0.2
Modify Date                     : 2018:06:15 13:06:07+05:30
Language                        : en
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Elements 10.0.0 (Windows)
Creator Tool                    : FrameMaker 10.0.2
Metadata Date                   : 2018:06:15 13:06:07+05:30
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:9b24bcf0-648e-4692-a269-3e0a797c5094
Instance ID                     : uuid:960fa42d-fee9-46e7-9f81-5cd2830683df
Page Mode                       : UseOutlines
Page Count                      : 16
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AO93PI0NL02000100

Navigation menu