THALES DIS AlS Deutschland MC45 Transmitter Module for mobile applications User Manual MC45
Gemalto M2M GmbH Transmitter Module for mobile applications MC45
Exhibit 08 User Manual
Siemens Cellular Engine Hardware Interface Description Version 00.02 DocID: MC45_HD_01_V00.02a MC45 Hardware Interface Description PRELIMINARY Document Name: MC45 Hardware Interface Description Version: Date: DocId: 00.02 August 12, 2002 MC45_HD_01_V00.02a Status: PRELIMINARY General notes With respect to any damages arising in connection with the described product or this document, Siemens shall be liable according to the General Conditions on which the delivery of the described product and this document are based. This product is not intended for use in life support appliances, devices or systems where a malfunction of the product can reasonably be expected to result in personal injury. Siemens AG customers using or selling this product for use in such applications do so at their own risk and agree to fully indemnify Siemens for any damages resulting from illegal use or resale. Applications incorporating the described product must be designed to be in accordance with the technical specifications provided in these guidelines. Failure to comply with any of the required procedures can result in malfunctions or serious discrepancies in results. Furthermore, all safety instructions regarding the use of mobile technical systems, including GSM products, which also apply to cellular phones must be followed. Handheld applications such as mobile phones or PDAs incorporating the described product must be in accordance with the guidelines for human exposure to radio frequency energy. The Specific Absorption Rate (SAR) of the application must be evaluated and approved to be compliant with national and international safety standards or directives. Subject to change without notice at any time. Copyright notice Copying of this document and giving it to others and the use or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. All rights reserved in the event of grant of a patent or the registration of a utility model or design. Copyright © Siemens AG 2002 MC45_HD_01_V00.02a Page 2 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Contents Version History........................................................................................................... 7 Introduction ................................................................................................................ 9 1.1 Related documents ............................................................................................. 9 1.2 Terms and abbreviations....................................................................................10 1.3 Type approval ....................................................................................................13 1.4 Safety precautions .............................................................................................15 Product concept........................................................................................................17 2.1 MC45 key features at a glance...........................................................................18 2.2 Circuit concept ...................................................................................................21 Application Interface.................................................................................................22 3.1 Operating modes ...............................................................................................23 3.2 Power supply .....................................................................................................25 3.2.1 Power supply pins on the board-to-board connector.............................25 3.2.2 Minimizing power losses.......................................................................26 3.2.3 Charging control ...................................................................................27 3.2.3.1 Battery pack characteristics ......................................................28 3.2.3.2 Recommended battery pack .....................................................29 3.2.3.3 Implemented charging technique ..............................................30 3.2.3.4 Operating modes during charging .............................................31 3.2.3.5 Charger requirements ...............................................................32 3.3 Power up / down scenarios ................................................................................33 3.3.1 Turn on MC45 ......................................................................................33 3.3.1.1 Turn on MC45 using the ignition line /IGT (Power on)...............33 3.3.1.2 Timing of the ignition process ...................................................34 3.3.1.3 Turn on MC45 using the POWER signal ...................................35 3.3.1.4 Turn on MC45 using the RTC (Alarm mode) .............................35 3.3.2 Power saving........................................................................................36 3.3.2.1 No power saving (AT+CFUN=1)................................................36 3.3.2.2 NON-CYCLIC SLEEP mode (AT+CFUN=0)..............................36 3.3.2.3 CYCLIC SLEEP mode (AT+CFUN=5, 6, 7 and 8) .....................36 3.3.2.4 Timing of the /CTS signal in CYCLIC SLEEP modes ................37 3.3.2.5 Wake up MC45 from SLEEP mode...........................................39 3.3.3 Turn off MC45 ......................................................................................40 3.3.3.1 Turn off MC45 using AT command ...........................................40 3.3.3.2 Emergency shutdown using /EMERGOFF pin...........................41 3.3.4 Automatic shutdown .............................................................................42 3.3.4.1 Temperature dependent shutdown............................................42 3.3.4.2 Undervoltage shutdown if battery NTC is present .....................43 3.3.4.3 Undervoltage shutdown if no battery NTC is present ................43 3.3.4.4 Shutdown in the event of overvoltage .......................................44 3.3.5 Summary of state transitions ................................................................45 3.4 RTC backup .......................................................................................................46 3.5 Serial interfaces .................................................................................................47 3.6 Audio interfaces .................................................................................................49 3.6.1 Microphone circuit ................................................................................50 MC45_HD_01_V00.02a Page 3 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.7 3.8 3.9 3.6.2 Speech processing ...............................................................................51 3.6.3 DAI timing.............................................................................................51 SIM interface......................................................................................................53 3.7.1 Requirements for using the CCIN pin ...................................................54 3.7.2 Design considerations for SIM card holder ...........................................55 3.7.3 Grounding the SIM interface.................................................................56 Control signals ...................................................................................................57 3.8.1 Inputs ...................................................................................................57 3.8.2 Outputs.................................................................................................58 3.8.2.1 Synchronization signal ..............................................................58 3.8.2.2 Using the SYNC pin to control a status LED .............................59 3.8.2.3 Behaviour of the /RING0 line (RS-232(0) interface only)...........60 Electrical specifications of the application interface............................................61 Antenna interface (antenna reference point – ARP) ...............................................65 Physical characteristics ...........................................................................................66 5.1 Mechanical dimensions of MC45........................................................................66 5.2 Mounting MC45 onto the application platform ....................................................69 5.3 Board-to-board connector ..................................................................................70 5.3.1 Mechanical dimensions of the Hirose DF12 connector .........................71 5.3.2 Adapter cabling ....................................................................................71 5.4 Antenna design ..................................................................................................72 5.4.1 Hirose antenna connector ....................................................................72 5.4.2 Antenna pad .........................................................................................75 Electrical, reliability and radio characteristics .......................................................76 6.1 Absolute maximum ratings .................................................................................76 6.2 Operating temperatures .....................................................................................76 6.3 Reliability characteristics ....................................................................................77 6.4 Power supply ratings..........................................................................................78 6.4.1 Current consumption during transmit burst...........................................79 6.5 Electrical characteristics of the voiceband part...................................................81 6.5.1 Setting audio parameters by AT commands .........................................81 6.5.2 Audio programming model ...................................................................82 6.5.3 Characteristics of audio modes ............................................................83 6.5.4 Voiceband receive path ........................................................................84 6.5.5 Voiceband transmit path.......................................................................85 6.6 Air interface........................................................................................................86 6.7 Electrostatic discharge .......................................................................................87 Reference Approval ..................................................................................................88 7.1 Reference Equipment ........................................................................................88 List of parts and accessories ...................................................................................89 MC45_HD_01_V00.02a Page 4 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Figures Figure 1: MC45 block diagram .............................................................................................21 Figure 2: Power supply limits during transmit burst ..............................................................26 Figure 3: Schematic of approved charging transistor, trickle charging and ESD protection..27 Figure 4: Battery pack circuit diagram ..................................................................................28 Figure 5: Charging process ..................................................................................................30 Figure 6: Power-on by ignition signal....................................................................................33 Figure 7: Timing of power-on process if VDDLP is not used ................................................34 Figure 8: Timing of power-on process if VDDLP is fed from external source........................34 Figure 9: Timing of /CTS signal (example for a 2.12 s paging cycle)....................................37 Figure 10: Beginning of power saving if CFUN=5.................................................................38 Figure 11: Deactivating GSM engine by /EMERGOFF signal ...............................................41 Figure 12: RTC supply from capacitor ..................................................................................46 Figure 13: RTC supply from rechargeable battery................................................................46 Figure 14: RTC supply from non-chargeable battery............................................................46 Figure 15: RS-232 interfaces ...............................................................................................47 Figure 16: Audio block diagram............................................................................................49 Figure 17: Schematic of microphone inputs .........................................................................50 Figure 18: DAI timing on transmit path .................................................................................52 Figure 19: DAI timing on receive path ..................................................................................52 Figure 20: SIM card holder of DSB45 Support Box ..............................................................55 Figure 21: Connecting a separate ground for SIM interface .................................................56 Figure 22: SYNC signal during transmit burst ......................................................................58 Figure 23: LED Circuit (Example) .........................................................................................59 Figure 24: Incoming voice call ..............................................................................................60 Figure 25: Incoming data call ...............................................................................................60 Figure 26: Pin assignment (top view on MC45) ....................................................................61 Figure 27: MC45 – top view..................................................................................................66 Figure 28: Mechanical dimensions of MC45.........................................................................67 Figure 29: MC45 bottom view...............................................................................................68 Figure 30: Hirose DF12C receptacle on MC45 .....................................................................70 Figure 31: Header Hirose DF12 series .................................................................................70 Figure 32: Mechanical dimensions of Hirose DF12 connector ..............................................71 Figure 33: Mechanical dimensions of U.FL-R-SMT connector..............................................72 Figure 34: U.FL-R-SMT connector with U.FL-LP-040 plug ...................................................73 Figure 35: U.FL-R-SMT connector with U.FL-LP-066 plug ...................................................73 Figure 36: Specifications of U.FL-LP-(V)-040(01) plug .........................................................74 Figure 37: Restricted area around antenna pad ...................................................................75 Figure 38: Typical current consumption vs. power level .......................................................79 Figure 39: Typical current consumption vs. return loss.........................................................80 Figure 40: AT audio programming model .............................................................................82 Figure 41: Reference equipment for approval ......................................................................88 Tables Table 1: MC45 key features .................................................................................................18 Table 2: Coding schemes and maximum net data rates over air interface ...........................20 Table 3: Overview of operating modes .................................................................................23 Table 4: Power supply pins of board-to-board connector .....................................................25 Table 5: Bill of material for external charging circuit .............................................................27 Table 6: Specifications of XWODA battery pack ..................................................................29 Table 7: Comparison Charge-only and Charge mode ..........................................................31 MC45_HD_01_V00.02a Page 5 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Table 8: AT commands available in Charge-only mode .......................................................32 Table 9: AT commands available in Alarm mode .................................................................35 Table 10: Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes............................39 Table 11: Temperature dependent behaviour.......................................................................43 Table 12: State transitions of MC45 .....................................................................................45 Table 13: Signals of the SIM interface (board-to-board connector) ......................................53 Table 14 : Pin assignment of Molex SIM card holder on DSB45 Support Box ......................55 Table 15: Input control signals of the MC45 module.............................................................57 Table 16: MC45 synchronization signal (if SYNC pin is set to mode 0 via AT^SSYNC)........58 Table 17: Coding of the status LED......................................................................................59 Table 18: MC45 ring signal...................................................................................................60 Table 19: Pin assignment and electrical description of application interface ........................62 Table 20: Return loss ...........................................................................................................65 Table 21: Ordering information DF12 series.........................................................................70 Table 22: Electrical and mechanical characteristics of the Hirose DF12C connector............70 Table 23: Product specifications of U.FL-R-SMT connector .................................................72 Table 24: Material and finish of U.FL-R-SMT connector and recommended plugs...............73 Table 25: Ordering information for Hirose U.FL Series.........................................................75 Table 26: Absolute maximum ratings ...................................................................................76 Table 27: Operating temperatures........................................................................................76 Table 28: Summary of reliability test conditions....................................................................77 Table 29: Power supply ratings ............................................................................................78 Table 30: Audio parameters adjustable by AT command .....................................................81 Table 31: Voiceband characteristics (typical), all values preliminary.....................................83 Table 32: Voiceband receive path ........................................................................................84 Table 33: Voiceband transmit path.......................................................................................85 Table 34: Air Interface..........................................................................................................86 Table 35: Measured electrostatic values ..............................................................................87 Table 36: List of parts and accessories ................................................................................89 Table 37: Molex sales contacts (subject to change) .............................................................90 Table 38: Hirose sales contacts (subject to change) ............................................................90 MC45_HD_01_V00.02a Page 6 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 0 Version History Preceding document: "MC45 Hardware Interface Description" Version 00.02 New document: "MC45 Hardware Interface Description" Version 00.02a Chapter Page What is new Throughout this manual: Replaced product photo of MC45. 1.4 15f Added notes regarding compliance with FCC guidelines Preceding document: "MC45 Hardware Interface Description" Version 00.01 New document: "MC45 Hardware Interface Description" Version 00.02 Chapter Page What is new Throughout this manual: All RS-232 signals, /IGT signal and /EMERGOFF are now preceded by “/” to indicate that the signals are active low. 2.1 3.5 18ff 47 Deleted CMOS. The RS-232 interface operates at 2.65V. 2.1 18ff Deleted statements on current consumption and storage temperature Serial interfaces: Autobauding also supported at 230kbps 2.2 21 Modified block diagram. 3.2 3.9 25 61 VDD pin recommended, for example, for LED or level shifter. 3.2.1 25 Deleted parameter of CHARGE pin. 3.2.3 27 Revised description of trickle and fast charging. 3.3.2 36 Revised information on power saving. 3.7.2 55 Figure 20 updated. Note regarding capacitors C1205 and C1206 added. 3.9 61ff Changed numbering of pins. Corrected comments on BATT+ pin, VDD pin, VDDLP pin. Corrected signal parameters of RS-232 interfaces and associated comments (no more necessary to connect unused input pins to VDD). Corrected input voltage (peak to peak). 65 Removed introduction. 5.1 66ff Updated MC45 drawings. Added bottom view and information about test points and ground pad. 5.2 69 Added recommendations for installation. 5.3 70 Table 21: Corrected HRS number of DF12C receptacle. Table 22: Added insertion and withdrawal force. 5.4.1 72ff Added specifications of U.FL-LP-(V)-040(01 6.1 76 Table 26: Added differential load resistance between EPN and EPP 6.2 76 Corrected description (without modifying operating temperatures). 6.3 77 Added information about reliability characteristics and temperature. 6.5 81 Added test points MC45_HD_01_V00.02a Page 7 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6.4.1 79ff Added current consumption during transmit burst. 6.5 81ff Added notes on AT commands where applicable. Table 31: Modified MIC input signal in modes 5 and 6. Table 32: Added Differential load capacitance 1000pF. Table 33: Voiceband transmit path: Corrected input voltage (peak to peak). 6.6 86 Updated Table 34: Air Interface 89 Added ordering information for VOTRONIC handset MC45_HD_01_V00.02a Page 8 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 1 Introduction This document describes the hardware interface of the Siemens MC45 module that connects to the cellular device application and the air interface. As MC45 is intended to integrate with a wide range of application platforms, all functional components are described in great detail. So this guide covers all information you need to design and set up cellular applications incorporating the MC45 module. It helps you quickly retrieve interface specifications, electrical and mechanical details and, last but not least, information on the requirements to be considered for integrating further components. 1.1 Related documents [1] [2] [3] [4] [5] [6] [7] MC45 AT Command Set for Version 00.02 MC45 GPRS Startup User's Guide (in preparation) MC45 Remote-SAT User's Guide, as of Version 00.02 (in preparation) DSB45 Support Box - Evaluation Kit for Siemens Cellular Engines Application Note 16: Upgrading MC45 Firmware (in preparation) Application Note 14: Audio and Battery Parameter Download MC45 Multiplexer User's Guide, as of Version 00.02 (in preparation) Prior to using the MC45 engines be sure to carefully read and understand the latest product information provided in the Release Notes (not available for release 00.02.) To visit the Siemens Website you can use the following link: http://www.siemens.com/wm MC45_HD_01_V00.02a Page 9 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 1.2 Terms and abbreviations Abbreviation Description ADC Analog-to-Digital Converter AFC Automatic Frequency Control AGC Automatic Gain Control ARFCN Absolute Radio Frequency Channel Number ARP Antenna Reference Point ASIC Application Specific Integrated Circuit Thermistor Constant B2B Board-to-board connector BER Bit Error Rate BTS Base Transceiver Station CB or CBM Cell Broadcast Message CE Conformité Européene (European Conformity) CHAP Challenge Handshake Authentication Protocol CPU Central Processing Unit CS Coding Scheme CSD Circuit Switched Data CTS Clear to Send DAC Digital-to-Analog Converter DAI Digital Audio Interface dBm0 Digital level, 3.14dBm0 corresponds to full scale, see ITU G.711, A-law DCE Data Communication Equipment (typically modems, e.g. Siemens GSM engine) DCS 1800 Digital Cellular System, also referred to as PCN DRX Discontinuous Reception DSB Development Support Box DSP Digital Signal Processor DSR Data Set Ready DTE Data Terminal Equipment (typically computer, terminal, printer or, for example, GSM application) DTR Data Terminal Ready DTX Discontinuous Transmission EFR Enhanced Full Rate EGSM Enhanced GSM EMC Electromagnetic Compatibility ESD Electrostatic Discharge ETS European Telecommunication Standard MC45_HD_01_V00.02a Page 10 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Abbreviation Description FDMA Frequency Division Multiple Access FR Full Rate GMSK Gaussian Minimum Shift Keying GPRS General Packet Radio Service GSM Global Standard for Mobile Communications HiZ High Impedance HR Half Rate I/O Input/Output IC Integrated Circuit IMEI International Mobile Equipment Identity ISO International Standards Organization ITU International Telecommunications Union kbps kbits per second LED Light Emitting Diode Li-Ion Lithium-Ion Mbps Mbits per second MMI Man Machine Interface MO Mobile Originated MS Mobile Station (GSM engine), also referred to as TE MSISDN Mobile Station International ISDN number MT Mobile Terminated NTC Negative Temperature Coefficient PA Power Amplifier PAP Password Authentication Protocol PBCCH Packet Switched Broadcast Control Channel PCB Printed Circuit Board PCL Power Control Level PCM Pulse Code Modulation PCN Personal Communications Network, also referred to as DCS 1800 PCS Personal Communication System, also referred to as GSM 1900 PDU Protocol Data Unit PLL Phase Locked Loop PPP Point-to-point protocol PSU Power Supply Unit R&TTE Radio and Telecommunication Terminal Equipment RAM Random Access Memory RF Radio Frequency MC45_HD_01_V00.02a Page 11 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Abbreviation Description RMS Root Mean Square (value) ROM Read-only Memory RTC Real Time Clock Rx Receive Direction SAR Specific Absorption Rate SELV Safety Extra Low Voltage SIM Subscriber Identification Module SMS Short Message Service SRAM Static Random Access Memory TA Terminal adapter (e.g. GSM engine) TDMA Time Division Multiple Access TE Terminal Equipment, also referred to as DTE Tx Transmit Direction UART Universal asynchronous receiver-transmitter URC Unsolicited Result Code USSD Unstructured Supplementary Service Data VSWR Voltage Standing Wave Ratio Phonebook abbreviations FD SIM fixdialling phonebook LD SIM last dialling phonebook (list of numbers most recently dialled) MC Mobile Equipment list of unanswered MT calls (missed calls) ME Mobile Equipment phonebook ON Own numbers (MSISDNs) stored on SIM or ME RC Mobile Equipment list of received calls SM SIM phonebook MC45_HD_01_V00.02a Page 12 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 1.3 Type approval MC45 is designed to comply with the directives and standards listed below. Please note that the product is still in a pre-release state and, therefore, type approval and testing procedures have not yet been completed. European Directives 99/05/EC Directive of the European Parliament and of the council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity, in short referred to as R&TTE Directive 1999/5/EC 89/336/EC Directive on electromagnetic compatibility 73/23/EC Directive on electrical equipment designed for use within certain voltage limits (Low Voltage Directive) North American Approval FCC US Equipment Authorization UL Product Safety Certification Standards of type approval ETS 300 607-1 Digital cellular telecommunications system (Phase 2); Mobile Station (MS) conformance specification; (equal GSM 11.10-1=>equal 3GPP51.010-1) ETSI EN 301 511 V7.0.1 (2000-12) Candidate Harmonized European Standard (Telecommunications series) Global System for Mobile communications (GSM); Harmonized standard for mobile stations in the GSM 900 and DCS 1800 bands covering essential requirements under article 3.2 of the R&TTE directive (1999/5/EC) (GSM 13.11 version 7.0.1 Release 1998) ETSI EN 301 489-7 V1.1.1 (2000-09) Candidate Harmonized European Standard (Telecommunications series) Electro Magnetic Compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS) EN 60 950 Safety of information technology equipment (2000) UL 60 950 Safety requirements CFR Title 47 Code of Federal Regulations, Part 2 and Part 15 (Telecommunications, PCS) Requirements of quality IEC 60068 Environmental testing DIN EN 60529 IP codes MC45_HD_01_V00.02a Page 13 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY SAR requirements specific to handheld mobiles Mobile phones, PDAs or other handheld transmitters and receivers incorporating a GSM module must be in accordance with the guidelines for human exposure to radio frequency energy. This requires the Specific Absorption Rate (SAR) of handheld MC45 based applications to be evaluated and approved for compliance with national and/or international regulations. Since the SAR value varies significantly with the individual product design manufacturers are advised to submit their product for approval if designed for handheld operation. For European and US markets the relevant directives are mentioned below. It is the responsibility of the manufacturer of the final product to verify whether or not further standards, recommendations of directives are in force outside these areas. Products intended for sale on US markets ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to Electromagnetic Fields (EMFs) from Mobile Telecommunication Equipment (MTE) in the frequency range 30MHz-6GHz Products intended for sale on European markets EN 50360 Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields (300 MHz - 3 GHz) MC45_HD_01_V00.02a Page 14 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 1.4 Safety precautions The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating MC45. Manufacturers of the cellular terminal are advised to convey the following safety information to users and operating personnel and to incorporate these guidelines into all manuals supplied with the product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Siemens AG assumes no liability for customer failure to comply with these precautions. When in a hospital or other health care facility, observe the restrictions on the use of mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guidelines posted in sensitive areas. Medical equipment may be sensitive to RF energy. The operation of cardiac pacemakers, other implanted medical equipment and hearing aids can be affected by interference from cellular terminals or mobiles placed close to the device. If in doubt about potential danger, contact the physician or the manufacturer of the device to verify that the equipment is properly shielded. Pacemaker patients are advised to keep their hand-held mobile away from the pacemaker, while it is on. Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it cannot be switched on inadvertently. The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems. Failure to observe these instructions may lead to the suspension or denial of cellular services to the offender, legal action, or both. Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots, chemical plants or where blasting operations are in progress. Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety hazard. Your cellular terminal or mobile receives and transmits radio frequency energy while switched on. Remember that interference can occur if it is used close to TV sets, radios, computers or inadequately shielded equipment. Follow any special regulations and always switch off the cellular terminal or mobile wherever forbidden, or when you suspect that it may cause interference or danger. Road safety comes first! Do not use a hand-held cellular terminal or mobile when driving a vehicle, unless it is securely mounted in a holder for handsfree operation. Before making a call with a hand-held terminal or mobile, park the vehicle. Handsfree devices must be installed by qualified personnel. Faulty installation or operation can constitute a safety hazard. MC45_HD_01_V00.02a Page 15 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY SOS IMPORTANT! Cellular terminals or mobiles operate using radio signals and cellular networks cannot be guaranteed to connect in all conditions. Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls. Remember, in order to make or receive calls, the cellular terminal or mobile must be switched on and in a service area with adequate cellular signal strength. Some networks do not allow for emergency calls if certain network services or phone features are in use (e.g. lock functions, fixed dialling etc.). You may need to deactivate those features before you can make an emergency call. Some networks require that a valid SIM card be properly inserted in the cellular terminal or mobile. Compliance with FCC guidelines Fix-mount and mobile devices incorporating MC45 modules must be designed to maintain a minimum separation distance of 20 cm between the antenna and the end user to satisfy RF exposure requirements for mobile transmitting devices. For portable devices incorporating MC45 modules the manufacturer of the final device is responsible to perform SAR measurements. MC45_HD_01_V00.02a Page 16 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 2 Product concept Designed for use on any GSM network in the world, Siemens MC45 is a tri-band GSM/GPRS engine that works on the three frequencies GSM 900 MHz, GSM 1800 MHz and GSM 1900 MHz. MC45 features GPRS multislot class 10 and supports the GPRS coding schemes CS-1, CS-2, CS-3 and CS-4. To save space on the application platform, MC45 comes as an extremely slim and compact module. This makes it ideally suited for a broad range of mobile computing devices, such as laptops, notebooks, multimedia appliances, and particularly offers easy integration with PDAs, pocket organizers or miniature mobile phones. The tiny MC45 module incorporates all you need to create high-performance GSM/GPRS solutions: baseband processor, power supply ASIC, complete radio frequency circuit including a power amplifier and antenna interface. The power amplifier is directly fed from the supply voltage BATT+. The MC45 software is residing in a flash memory device. An additional SRAM enables MC45 to meet the demanding requirements of GPRS connectivity. The physical interface to the cellular application is made through a board-to-board connector. It consists of 50 pins, required for controlling the unit, transferring data and audio signals and providing power supply lines. MC45 comprises two serial (RS-232) interfaces giving you maximum flexibility for easy integration with the Man-Machine Interface (MMI). An extremely versatile audio concept offers various audio interfaces, each available on the board-to-board connector: a digital audio interface (DAI) and two analog audio interfaces. This allows you to connect up to three audio devices in any combination, all at the same time. Using AT commands you can easily switch back and forth and select different audio modes. The external dual-band or triple-band antenna can be connected optionally to a connector on the top side or to a pad on the bottom side. For battery powered applications, MC45 features a charging control which can be used to charge a Li-Ion battery. The charging circuit must be implemented outside the module on the application platform. MC45_HD_01_V00.02a Page 17 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 2.1 MC45 key features at a glance Table 1: MC45 key features Feature Implementation Power supply Single supply voltage 3.3V – 4.5V GSM class Small MS Frequency bands · Tri-band EGSM 900, GSM 1800, GSM 1900 · Compliant to GSM Phase 2/2+ · Class 4 (2W) at EGSM900 Transmit power · Class 1 (1W) at GSM1800 and GSM 1900 GPRS connectivity · GPRS multi-slot class 10 · GPRS mobile station class B Temperature range · Normal operation: · Restricted operation: Temperature control and auto switch-off DATA -20°C to +55°C -25°C to -20°C and +55°C to +70°C · Constant temperature control prevents damage from the module when the specified temperature is exceeded. GPRS: · GPRS data downlink transfer: max. 85.6 kbps (see Table 2) · GPRS data uplink transfer: max. 21.4 kbps (see Table 2) · Coding scheme: CS-1, CS-2, CS-3 and CS-4 · MC45 supports the two protocols PAP (Password Authentication Protocol) and CHAP (Challenge Handshake Authentication Protocol) commonly used for PPP connections. · Support of Packet Switched Broadcast Control Channel (PBCCH) allows you to benefit from enhanced GPRS performance when offered by the network operators. CSD: · CSD transmission rates: 2.4, 4.8, 9.6, 14.4 kbps, non-transparent, V.110 · Unstructured WAP: SMS Supplementary Services Data (USSD) support · WAP compliant · MT, MO, CB, Text and PDU mode · SMS storage: SIM card plus 25 SMS locations in the mobile equipment · Transmission of SMS alternatively over CSD or GPRS. Preferred mode can be user-defined. FAX MC45_HD_01_V00.02a Group 3: Class 1, Class 2 Page 18 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Feature Implementation SIM interface · Supported SIM card: 3V · External SIM card reader has to be connected via interface connector (note that card reader is not part of MC45) External antenna Connected via 50 Ohm antenna connector or antenna pad Audio interfaces Two analog audio interfaces, one digital audio interface (DAI) Speech codec · Half Rate (ETS 06.20) · Full Rate (ETS 06.10) · Enhanced Full Rate (ETS 06.50 / 06.60 / 06.80) Two serial interfaces: RS-232(0), RS-232(1) · 2.65V level, bi-directional bus for AT commands and data · RS-232(0) – full-featured RS-232 interface. Supports RTS0/CTS0 hardware handshake and software XON/XOFF flow control. Multiplex ability according to GSM 07.10 Multiplexer Protocol. · RS-232(1) - 4-wire RS-232 interface. Supports RTS1/CTS1 hardware handshake. · Baud rate: 300bps ... 230kbps on RS-232(0), RS-232(1) · Autobauding: RS-232(0) only: Supported baud rates are 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps Phonebook management Supported phonebook types: SM, FD, LD, MC, RC, ON, ME SIM Application Toolkit Supports SAT class 3, GSM 11.14 Release 98 Real time clock Implemented Timer function Programmable via AT command Physical characteristics Size: 53 +0.2 x 34 +0.2 x 3.5+0.3 mm Weight: 10g Firmware upgrade Firmware upgradable over serial interface and SIM interface Evaluation kit The DSB45 Support Box is an evaluation kit designed to test and type approve Siemens cellular engines and provide a sample configuration for application engineering. See Chapter 8 for ordering information. MC45_HD_01_V00.02a Page 19 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Table 2: Coding schemes and maximum net data rates over air interface Coding scheme 1 Timeslot 2 Timeslots 4 Timeslots CS-1: 9.05 kbps 18.1 kbps 36.2 kbps CS-2: 13.4 kbps 26.8 kbps 53.6 kbps CS-3: 15.6 kbps 31.2 kbps 62.4 kbps CS-4: 21.4 kbps 42.8 kbps 85.6 kbps Please note that the values stated above are maximum ratings which, in practice, are influenced by a great variety of factors, primarily, for example, traffic variations and network coverage. MC45_HD_01_V00.02a Page 20 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 2.2 Circuit concept Figure 1 shows a block diagram of the MC45 module and illustrates the major functional components: · · · · · · · GSM / GPRS baseband processor Power supply ASIC Flash SRAM GSM RF section incl. transceiver and RF power amplifier Antenna interface Application interface (board-to-board connector) RF Power Amplifier Data SRAM Adr Control Interface RF - Baseband GSM Controller Data Flash Adr Send Control Receive Control CCRST CCCLK CCIO CCIN (GND) DAI 2x Audio RS232(0) RS232(1) SYNC SIM Interface VDD VDDLP Measuring Network EMERGOFF Power Supply ASIC IGT POWER CHARGE MC45 BATT+ GND CCIN Application Interface (50 pins) RF Part CCVCC SIM POWER Ext. Charging Circuit NTC BATT_TEMP Figure 1: MC45 block diagram MC45_HD_01_V00.02a Page 21 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3 Application Interface MC45 is equipped with a 50-pin 0.5mm pitch board-to-board connector that connects to the cellular application platform. The host interface incorporates several sub-interfaces described in the following chapters: · Power supply and charging control (see Chapters 3.2 and 3.3) · Dual serial interface (see Chapter 3.5) · Two analog audio interfaces and a digital audio interface (see Chapter 3.6) · SIM interface (see Chapter 3.7) Electrical and mechanical characteristics of the board-to-board connector are specified in Chapter 5.3. Ordering information for mating connectors and cables are included. MC45_HD_01_V00.02a Page 22 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.1 Operating modes The table below briefly summarizes the various operating modes referred to in the following chapters. Table 3: Overview of operating modes Mode Function Normal operation GSM / GPRS SLEEP Various powersave command. modes set with AT+CFUN Software is active to minimum extent. If the module was registered to the GSM network in IDLE mode, it is registered and paging with the BTS in SLEEP mode, too. Power saving can be chosen at different levels: The NON-CYCLIC SLEEP mode (AT+CFUN=0) disables the AT interface. The CYCLIC SLEEP modes AT+CFUN=5, 6, 7 and 8 alternatingly activate and deactivate the AT interfaces to allow permanent access to all AT commands. POWER DOWN GSM IDLE Software is active. Once registered to the GSM network, paging with BTS is carried out. The module is ready to send and receive. GSM TALK Connection between two subscribers is in progress. Power consumption depends on network coverage individual settings, such as DTX off/on, FR/EFR/HR, hopping sequences, antenna. GPRS IDLE Module is ready for GPRS data transfer, but no data is currently sent or received. Power consumption depends on network settings and GPRS configuration (e.g. multislot settings). GPRS DATA GPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and GPRS configuration (e.g. used multislot settings). Normal shutdown after sending the AT^SMSO command. The Power Supply ASIC (PSU-ASIC) disconnects the supply voltage from the baseband part of the circuit. Only a voltage regulator in the PSU-ASIC is active for powering the RTC. Software is not active. The RS-232 interfaces are not accessible. Operating voltage (connected to BATT+) remains applied. MC45_HD_01_V00.02a Page 23 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Mode Function Alarm mode Restricted operation launched by RTC alert function while the module is in POWER DOWN mode. Module will not be registered to GSM network. Limited number of AT commands is accessible. If application is battery powered: No charging functionality in Alarm mode. Charge-only mode Limited operation for battery powered applications. Enables charging while module is detached from GSM network. Limited number of AT commands is accessible. There are several ways to launch Charge-only mode: · From POWER DOWN mode: Connect charger to the POWER pin of MC45 when engine was powered down by AT^SMSO. · From Normal mode: Connect charger to the POWER pin of MC45, then enter AT^SMSO. Charge mode during normal operation Normal operation (SLEEP, IDLE, TALK, GPRS IDLE, GPRS DATA) and charging running in parallel. Charge mode changes to Charge-only mode when the module is powered down before charging has been completed. See Table 10 and Table 12 for the various options of waking up MC45 and proceeding from one mode to another. MC45_HD_01_V00.02a Page 24 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.2 Power supply The power supply of MC45 has to be a single voltage source of VBATT+= 3.3V...4.5V. It must be able to provide sufficient current in a transmit burst which typically rises to 2A. Beyond that, the power supply must be able to account for increased current consumption if the module is exposed to inappropriate conditions, for example antenna mismatch. For further details see Chapters 3.2.2 and 6.4.1. All the key functions for supplying power to the device are handled by an ASIC power supply. The ASIC provides the following features: · Stabilizes the supply voltages for the GSM baseband using low drop linear voltage regulators. · Controls the module's power up and s procedures. A watchdog logic implemented in the baseband processor periodically sends signals to the ASIC, allowing it to maintain the supply voltage for all digital MC45 components. Whenever the watchdog pulses fail to arrive constantly, the module is turned off. · Delivers, across the VDD pin, a regulated voltage of 2.9V. The output voltage VDD may be used to supply, for example, an external LED or a level shifter. However, the external circuitry must not cause any spikes or glitches on voltage VDD. This voltage is not available in POWER DOWN mode. Therefore, the VDD pin can be used to indicate whether or not MC45 is in POWER DOWN mode. · Includes a switch to provide power to the SIM interface. The RF power amplifier is driven directly from BATT+. 3.2.1 Power supply pins on the board-to-board connector Five BATT+ pins of the board-to-board connector are dedicated to connect the supply voltage, five GND pins are recommended for grounding. The POWER and CHARGE pins serve as control signals for charging a Li-Ion battery. VDDLP can be used to back up the RTC. Table 4: Power supply pins of board-to-board connector Signal name I/O Description Parameter BATT+ I/O Positive operating voltage 3.3 V...4.5 V, Ityp £ 2 A during transmit burst The minimum operating voltage must not fall below 3.3 V, not even in case of voltage drop. GND Ground POWER This line signalizes to the processor that the charger is connected. CHARGE Control signal for external charging transistor VDDLP I/O Can be used to back up the RTC when VBATT+ is not applied. See Chapter 3.4 MC45_HD_01_V00.02a 0V UOUT,max < VBATT+ UIN = 2.0 V...5.5 V Ri = 1kW Iin,max = 30µA Page 25 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.2.2 Minimizing power losses When designing the power supply for your application please pay specific attention to power losses. Ensure that the input voltage VBATT+ never drops below 3.3 V on the MC45 board, not even in a transmit burst where current consumption can rise to peaks of 2A. It should be noted that MC45 switches off when exceeding these limits. Any voltage drops that may occur in a transmit burst should not exceed 400mV. For further details see Chapter 6.4. The best approach to reducing voltage drops is to use a board-to-board connection as recommended, and a low impedance power source. The resistance of the power supply lines on the host board and of a battery pack should also be considered. Note: If the application design requires an adapter cable between both board-to-board connectors, use a flex cable as short as possible in order to minimize power losses. Example: If the length of the flex cable reaches the maximum length of 200mm, this connection may cause, for example, a resistance of 50mΩ in the BATT+ line and 50mΩ in the GND line. As a result, a 2A transmit burst would add up to a total voltage drop of 200mV. Plus, if a battery pack is involved, further losses may occur due to the resistance across the battery lines and the internal resistance of the battery. Transmit burst 2A Transmit burst 2A BATT+ max. 400mV min. 3.3V Figure 2: Power supply limits during transmit burst MC45_HD_01_V00.02a Page 26 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.2.3 Charging control MC45 integrates a charging management for Li-Ion batteries. You can skip this chapter if charging is not your concern, or if you are not using the implemented charging algorithm. MC45 has no on-board charging circuit. To benefit from the implemented charging management you are required to install a charging circuit within your application. In this case, MC45 needs to be powered from a Li-Ion battery pack, e.g. as specified in Table 6. The module only delivers, via its POWER line and CHARGE line, the control signals needed to start and stop the charging process. The charging circuit should include a transistor and should be designed as illustrated in Figure 3. A list of parts recommended for the external circuit is given in Table 5. BATT_TEMP 1/ ESDA6V1-5W6 1SS355 470R POWER BATT+ 4V3 pcb spark gap 1/ CRS04 SI3441DV 100nF 10k ESDA6V1-5W6 3k3 CHARGE Figure 3: Schematic of approved charging transistor, trickle charging and ESD protection Table 5: Bill of material for external charging circuit Part Description First supplier SI3441DV p-chan 2.5V (G-S) MOSFET VISHAY: SI3441DV-T1 (TSOP-6) NEC: 1SS355 100mA Si-diode (UMD2) ROHM: Toshiba: 1SS352TPH3 CRS04 1A Shottky diode Toshiba: CRS04 4V3 250mW; 200mA; 4.3V Z-Diode (SOD323) Philips: PDZ4.3B STM: ESDA6V1-5W6 ESDA6V1-5W6 ESD protection transil array 1SS355TE-18 Second supplier UPA1911TE-T1 ROHM: UDZS4.3B UDZ4.3B 470R, 3k3, 10k Resistor, e.g. 0805 or 0603 100nF Ceramic capacitor 50V PCB spark gap 0.2mm spark gap on PCB MC45_HD_01_V00.02a Page 27 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.2.3.1 Battery pack characteristics The charging algorithm has been optimized for a Li-Ion battery pack that meets the characteristics listed below. It is recommended that the battery pack you want to integrate into your MC45 application is compliant with these specifications. This ensures reliable operation, proper charging and, particularly, allows you to monitor the battery capacity using the AT^SBC command (see [1] for details). Failure to comply with these specifications might cause AT^SBC to deliver incorrect battery capacity values. A battery pack especially designed to operate with MC45 modules is specified in Chapter 3.2.3.2. · · · · · · · Li-Ion battery pack specified for a maximum charging voltage of 4.2 V and a capacity of 800 mAh. Battery packs with a capacity down to 600 mAh or more than 800 mAh are allowed, too. Since charging and discharging largely depend on the battery temperature, the battery pack should include an NTC resistor. If the NTC is not inside the battery it must be in thermal contact with the battery. The NTC resistor must be connected between BATT_TEMP and GND. Required NTC characteristics are: 10 kΩ +5% @ 25°C, B25/85 = 3435K +3% (alternatively acceptable: 10 kΩ +2% @ 25°C, B25/50 = 3370K +3%). Please note that the NTC is indispensable for proper charging, i.e. the charging process will not start if no NTC is present. Ensure that the pack incorporates a protection circuit capable of detecting overvoltage (protection against overcharging), undervoltage (protection against deep discharging) and overcurrent. The circuit must be insensitive to pulsed current. On the MC45 module, a built-in measuring circuit constantly monitors the supply voltage. In the event of undervoltage, it causes MC45 to power down. Undervoltage thresholds are specific to the battery pack and must be evaluated for the intended model. When you evaluate undervoltage thresholds, consider both the current consumption of MC45 and of the application circuit. The internal resistance of the battery and the protection should be as low as possible. It is recommended not to exceed 150mΩ, even in extreme conditions at low temperature. The battery cell must be insensitive to rupture, fire and gasing under extreme conditions of temperature and charging (voltage, current). The battery pack must be protected from reverse pole connection. For example, the casing should be designed to prevent the user from mounting the battery in reverse orientation. The battery pack must be approved to satisfy the requirements of CE conformity. Figure 4 shows the circuit diagram of a typical to BATT+ battery pack design that includes the protection elements described above. to BATT_TEMP to GND NTC Protection Circuit + Battery cell Figure 4: Battery pack circuit diagram MC45_HD_01_V00.02a Page 28 of 90 Polyfuse 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.2.3.2 Recommended battery pack The following battery pack has been especially designed for use with MC45 modules. Table 6: Specifications of XWODA battery pack Product name, type XWODA, Li-Ion, 3.6V, 800mAh Vendor Shenzhen Xwoda Electronic Co., Ltd Unit 3003, Yingjingyuan,Zhongdian Garden, Shenzhen 518032 P.R.China To place orders or obtain more information please contact: Contact: Edward Lau or Andy Zhao Phone: +86-755-7623789 ext. 314 Fax: +86-755-7623078 Email: Edward-lau@xwoda.com.cn Email: Andy-zhao@Xwoda.com.cn Nominal voltage 3.6V Capacity 800mAh NTC 10kΩ ± 5% @ 25°C, B (25/85)=3435K ± 3% Overcharge detection voltage 4.325 ± 0.025V Overcharge release voltage 4.075 ± 0.025V Overdischarge detection voltage 2.5 ± 0.05V Overdischarge release voltage 2.9 ± 0.5V Overcurrent detection 3 ± 0.5A Nominal working current <5µA Current of low voltage detection 0.5µA Overcurrent detection delay time 8~16ms Short detection delay time 50µs Overdischarge detection delay time 31~125ms Overcharge detection delay time 1s Internal resistance <130mΩ MC45_HD_01_V00.02a Page 29 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.2.3.3 Implemented charging technique If the external charging circuit follows the recommendation of Figure 3, the charging process consists of trickle charging and processor controlled fast charging. For this solution, the fast charging current provided by the charger or any other external source must be limited to 500mA. Trickle charging · Trickle charging starts when the charger is connected to the POWER pin of the external charging circuit. The charging current depends on the voltage difference between the pins POWER and BATT+ of the external charging circuit. · Trickle charging stops when the battery voltage reaches 3.6V. Fast charging · After trickle charging has raised the battery voltage to 3.2V within 60 minutes +10% from connecting the charger, the power ASIC turns on and wakes up the baseband processor. Now, processor controlled fast charging begins. If the battery voltage was already above 3.2V, processor controlled fast charging starts just after the charger was connected to the POWER pins of the external charging circuit and of the module. If MC45 was in POWER DOWN mode, it turns on and enters the Charge-only mode along with fast charging (see also Chapter 3.3.1.3). · Fast charging delivers a constant current until the battery voltage reaches 4.2V and then proceeds with varying charge pulses. As shown in Figure 5, the pulse duty cycle is reduced to adjust the charging procedure and prevent the voltage from overshooting beyond 4.2V. Once the pulse width reaches the minimum of 100ms and the duty cycle does not change for 2 minutes, fast charging is completed. · Fast charging can only be accomplished in a temperature range from 0°C to +45°C. Voltage 4.3 4.2 3.8 3.4 100ms 2 ... 0.1s 100ms 0.1 ... 2s 3.0 Constant current tOFF = 100 ms tON = 100 ms Time Figure 5: Charging process Note: Do not connect the charger to the BATT+ lines. Only the POWER input of the charging circuit is intended as input for charging current! The POWER pin of MC45 is the input only for indicating a connected charger! The battery manufacturer must guarantee that the battery complies with the described charging technique. MC45_HD_01_V00.02a Page 30 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY What to do if software controlled charging does not start up? If trickle charging fails to raise the battery voltage to 3.2V within 60 minutes +10%, processor controlled charging does not begin. To start fast charging you can do one of the following: · Once the voltage has risen above its minimum of 3V, you can try to start software controlled charging by pulling the /IGT line to ground. · If the voltage is still below 3V, driving the /IGT line to ground switches the timer off. Without the timer running, MC45 will not proceed to software controlled charging. To restart the timer you are required to shortly disconnect and reconnect the charger. 3.2.3.4 Operating modes during charging Of course, the battery can be charged regardless of the engine's operating mode. When the GSM engine is in Normal mode (SLEEP, IDLE, TALK GPRS IDLE or GPRS DATA mode), it remains operational while charging is in progress (provided that sufficient voltage is applied). The charging process during the Normal mode is referred to as Charge mode. If the charger is connected to the POWER pin while MC45 is in POWER DOWN mode, MC45 goes into Charge-only mode. Table 7: Comparison Charge-only and Charge mode Charge-only mode Charge mode How to activate mode Features Connecting charger to the POWER pin of · Battery can be charged while GSM engine MC45 while MC45 is remains operational and registered to the GSM network. · operating, e.g. in IDLE or TALK mode · In IDLE and TALK mode, the RS-232 interface · in SLEEP mode is accessible. AT command set can be used to full extent. · In the NON-CYCLIC SLEEP mode, the RS232 interface is not accessible at all. During the CYCLIC SLEEP mode it can be used as described in Chapter 3.3.2.3. Connecting charger to the POWER pin of · Battery can be charged while GSM engine is MC45 while MC45 is deregistered from GSM network. · Charging runs smoothly due to constant · in POWER DOWN mode current consumption. · in Normal mode: Connect charger to · The AT interface is accessible and allows to the POWER pin of MC45, then enter use the commands listed below. AT^SMSO. IMPORTANT: While trickle charging is in progress, be sure that the application is switched off. If the application is fed from the trickle charge current the module might be prevented from proceeding to software controlled charging since the current would not be sufficient. MC45_HD_01_V00.02a Page 31 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Features of Charge-only mode Once the GSM engine enters the Charge-only mode, the AT command interface presents an Unsolicited Result Code (URC) which reads: ^SYSSTART CHARGE-ONLY MODE Note that this URC will not appear when autobauding was activated (due to the missing synchronization between DTE and DCE upon start-up). Therefore, it is recommended to select a fixed baudrate before using the Charge-only mode. While the Charge-only mode is in progress, you can only use the AT commands listed in Table 8. For further instructions refer to the AT Command Set supplied with your GSM engine. Table 8: AT commands available in Charge-only mode AT command Use AT+CALA Set alarm time AT+CCLK Set date and time of RTC AT^SBC Monitor charging process AT^SCTM Note: While charging is in progress, no battery capacity value is available. To query the battery capacity disconnect the charger. If the charger connects externally to the host device no charging parameters are transferred to the module. In this case, the command cannot be used. Query temperature range, enable/disable URCs to report critical temperature ranges AT^SMSO Power down GSM engine To proceed from Charge-only mode to normal operation, it is necessary to drive the ignition line to ground. This must be implemented in your host application as described in Chapter 3.3.1.1. When the engine is in Alarm mode there is no direct way to start charging, i.e. charging will not begin even though the charger connects to the POWER pin of MC45. See also Chapter 3.3.5 which summarizes the various options of changing the mode of operation. If your host application uses the SYNC pin to control a status LED as described in Chapter 3.8.2.2, please note that the LED is off while the GSM engine is in Charge-only mode. 3.2.3.5 Charger requirements If you are using the implemented charging technique and the charging circuit recommended in Figure 3, the charger must be designed to meet the following requirements: a) Simple transformer power plug - Output voltage: 5.5V...8V (under load) - The charge current must be limited to 500mA - Voltage spikes that may occur while you connect or disconnect the charger must be limited to a maximum of 25V and must not exceed 1ms - There must not be any capacitor on the secondary side of the power plug (avoidance of current spikes at the beginning of charging) b) Supplementary requirements for a) to ensure a regulated power supply - When current is switched off a voltage peak of 10V is allowed for a maximum 1ms - When current is switched on a spike of 1.6A for 1ms is allowed MC45_HD_01_V00.02a Page 32 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.3 Power up / down scenarios 3.3.1 Turn on MC45 MC45 can be activated in a variety of ways, which are described in the following chapters: · via ignition line /IGT: starts normal operating state (see Chapters 3.3.1.1 and 3.3.1.2) · via POWER line: starts charging algorithm (see Chapters 3.2.3.4 and 3.3.1.3) · via RTC interrupt: starts Alarm mode (see Chapter 3.3.1.4) 3.3.1.1 Turn on MC45 using the ignition line /IGT (Power on) To switch on MC45 the /IGT (Ignition) signal needs to be driven to ground level for at least 100ms. This can be accomplished using an open drain/collector driver in order to avoid current flowing into this pin. BATT+ min. 10ms HiZ min. 100ms HiZ /IGT 50 to 100ms VDD ca. 180ms Internal reset max. 900ms /EMERGOFF RS-232 interface generated by GSM engine undefined defined For details please see Chapter 3.3.1.2 Figure 6: Power-on by ignition signal If configured to a fix baud rate, MC45 will send the result code ^SYSSTART to indicate that it is ready to operate. This result code does not appear when autobauding is active. See Chapter AT+IPR in [1]. In a battery operated MC45 application, the duration of the /IGT signal must be 1s minimum when the charger is connected and you may want to go from charging to Normal mode. MC45_HD_01_V00.02a Page 33 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.3.1.2 Timing of the ignition process When designing your application platform take into account that powering up MC45 requires the following steps. · The ignition line cannot be operated until VBATT+ passes the level of 3.0V. · 10ms after VBATT+ has reached 3.0V the ignition line can be switched low. The duration of the falling edge must not exceed 1ms. · Another 100ms are required to power up the module. · Ensure that VBATT+ does not fall below 3.0V while the ignition line is driven. Otherwise the module cannot be activated. · If the VDDLP line is fed from an external power supply as explained in Chapter 3.4, the /IGT line is HiZ before the rising edge of BATT+. 3.0V VBATT+ 0V HiZ HiZ /IGT 10ms min. 100ms max. 1ms Figure 7: Timing of power-on process if VDDLP is not used 3.0V VBATT+ 0V HiZ HiZ /IGT 10ms min. 100ms max. 1ms Figure 8: Timing of power-on process if VDDLP is fed from external source MC45_HD_01_V00.02a Page 34 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.3.1.3 Turn on MC45 using the POWER signal As detailed in Chapter 3.2.3.4, the charging adapter can be connected regardless of the module’s operating mode (except for Alarm mode). If the charger is connected to the POWER pins of the external charging circuit and of the module while MC45 is off, processor controlled fast charging starts (see Chapter 3.2.3.3). MC45 enters a restricted mode, referred to as Charge-only mode where only the charging algorithm will be launched. During the Charge-only mode MC45 is neither logged on to the GSM network nor is the RS232 interface fully accessible. To switch to normal operation and log on to the GSM network, the /IGT line needs to be activated. 3.3.1.4 Turn on MC45 using the RTC (Alarm mode) Another power-on approach is to use the RTC, which is constantly supplied with power from a separate voltage regulator in the power supply ASIC. The RTC provides an alert function which allows to wake up MC45 while power is off. To prevent the engine from unintentionally logging into the GSM network, this procedure only enables restricted operation, referred to as Alarm mode. It must not be confused with a wake-up or alarm call that can be activated by using the same AT command, but without switching off power. Use the AT+CALA command to set the alarm time. The RTC retains the alarm time if MC45 was powered down by AT^SMSO. Once the alarm is timed out and executed, MC45 enters into the Alarm mode. This is indicated by an Unsolicited Result Code (URC) which reads: ^SYSSTART ALARM MODE In Alarm mode only a limited number of AT commands is available. For further instructions refer to the AT Command Set. Table 9: AT commands available in Alarm mode AT command Use AT+CALA Set alarm time AT+CCLK Set date and time of RTC AT^SBC In Alarm mode, you can only query the present current consumption and check whether or not a charger is connected. The battery capacity is returned as 0, regardless of the actual voltage (since the values measured directly on the cell are not delivered to the module). AT^SCTM Query temperature range, enable/disable URCs to report critical temperature ranges AT^SMSO Power down GSM engine For the GSM engine to change from the Alarm mode to full operation (normal operating mode) it is necessary to drive the ignition line to ground. This must be implemented in your host application as described in Chapter 3.3.1.1. If your application is battery powered note that charging cannot be started while the engine is in Alarm mode, i.e. charging will not begin even though the charger connects to the POWER line. See also Chapter 3.3.5 which summarizes the various options of changing the mode of operation. If your host application uses the SYNC pin to control a status LED as described in Chapter 3.8.2.2, please note that the LED is off while the GSM engine is in Alarm mode. MC45_HD_01_V00.02a Page 35 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.3.2 Power saving SLEEP mode reduces the functionality of the MC45 module to a minimum and, thus, minimizes the current consumption to the lowest level. SLEEP mode is set with the AT+CFUN command which provides the choice of the functionality levels=0, 1, 5, 6, 7 or 8, all explained below. Further instructions of how to use AT+CFUN can be found in [1]. IMPORTANT: The AT+CFUN command can be executed before or after entering PIN1. Nevertheless, please keep in mind that power saving works only while the module is registered to the GSM network. If you attempt to activate power saving while the module is detached, the selected level will be set, though power saving does not take effect. To check whether power saving is on, you can query the status of AT+CFUN if you have chosen CYCLIC SLEEP mode. If available, you can take advantage of the status LED controlled by the SYNC pin (see Chapter 3.8.2.2). The LED stops flashing once the module starts power saving. The wake-up procedures are quite different depending on the selected SLEEP mode. Table 10 compares the wake-up events that can occur in NON-CYCLIC SLEEP mode and in the four CYCLIC SLEEP modes. 3.3.2.1 No power saving (AT+CFUN=1) The functionality level =1 is where power saving is switched off. This is the default after startup. 3.3.2.2 NON-CYCLIC SLEEP mode (AT+CFUN=0) If level 0 has been selected (AT+CFUN=0), the serial interface is blocked. The module shortly deactivates power saving to listen to a paging message sent from the base station and then immediately resumes power saving. Level 0 is called NON-CYCLIC SLEEP mode, since the serial interface is not alternatingly made accessible as in CYCLIC SLEEP mode. The first wake-up event fully activates the module, enables the serial interface and terminates the power saving mode. In short, it takes MC45 back to the highest level of functionality =1. 3.3.2.3 CYCLIC SLEEP mode (AT+CFUN=5, 6, 7 and 8) The functionality levels AT+CFUN=5, AT+CFUN=6, AT+CFUN=7 and AT+CFUN=8 are referred to as CYCLIC SLEEP modes. The major benefit over the NON-CYCLIC SLEEP mode is that the serial interface is not permanently blocked and that packet switched calls may go on without terminating the selected CYCLIC SLEEP mode. This allows MC45 to become active, for example to perform a GPRS data transfer, and to resume power saving after the GPRS data transfer is completed. The four CYCLIC SLEEP modes give you greater flexibility regarding the wake-procedures: Basically, you can enter AT+CFUN=1 to permanently wake up the module. Also, MC45 can automatically resume power saving, after you have sent or received a short message or made a call. Please refer to Table 10 for more details. MC45_HD_01_V00.02a Page 36 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY The CYCLIC SLEEP mode is a dynamic process which alternatingly enables and disables the serial interface. The application must be configured to use hardware flow control. By setting/resetting the /CTS signal, the module indicates to the application when the UART is active. The application must wait until /CTS is set (i.e. is active low) on the physical UART before data can be sent to the module. The module starts or resumes power saving two seconds (AT+CFUN=5 or AT+CFUN=7) or ten minutes (AT+CFUN=6 or AT+CFUN=8) after the last character was sent or received. It resets the /CTS signal, and after additional 5ms, physically deactivates the UART to save power. See Figure 10. Note: If both serial interfaces RS-232(0) and RS-232(1) are connected, both are synchronized. Although not explicitly stated, all explanations given in this chapter refer equally to RS-232(0) and RS-232(1), and accordingly to /CTS0 and /CTS1. 3.3.2.4 Timing of the /CTS signal in CYCLIC SLEEP modes The /CTS signal is enabled in synchrony with the module’s paging cycle. It goes active low each time when the module starts listening to a paging message block from the base station. The timing of the paging cycle varies with the base station and can be determined by the following formula: 4.615 ms (TDMA frame duration) * 51 (number of frames) * DRX value. DRX (Discontinuous Reception) is a value from 2 to 9, resulting in paging intervals from 0.47 to 2.12 seconds. The DRX value of the base station is assigned by the network operator. If DRX > 3, i.e. if paging is performed at intervals from 0.71 to 2.12 seconds, each listening period causes the /CTS signal to go active low. If DRX is 2, i.e. if paging is done every 0.47 nd seconds, the /CTS signal is activated with every 2 listening period. The /CTS signal stays active low for 20 ms. This is followed by another 5 ms UART activity. Thus, once the /CTS signal goes active low, you have 25 ms to enter characters. In the pauses between listening to paging messages, while /CTS is high, the module resumes power saving and the AT interface is not accessible. See Figure 9. Paging message Paging message 2.12 s /CTS 20 ms Paging message 20 ms 5 ms AT interface disabled Paging message 2.12 s 2.12 s 20 ms 20 ms 5 ms 5 ms 5 ms AT interface enabled Figure 9: Timing of /CTS signal (example for a 2.12 s paging cycle) MC45_HD_01_V00.02a Page 37 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Figure 10 illustrates the CFUN=5 mode, which resets the /CTS signal 2 seconds after the last character was sent or received. The UART is kept active for another 5 ms before power saving begins. Paging message 2.12 s Paging message 2.12 s Paging message 2.12 s Paging message Beginning of power saving /CTS 20 ms 2s 1st character 5 ms 20 ms 5 ms 5 ms Last character AT interface disabled AT interface enabled Figure 10: Beginning of power saving if CFUN=5 MC45_HD_01_V00.02a Page 38 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.3.2.5 Wake up MC45 from SLEEP mode A wake-up event is any event that switches off the SLEEP mode and causes MC45 to return to full functionality. In short, it takes MC45 back to AT+CFUN=1. Definitions of the state transitions described in Table 10: Yes = MC45 exits SLEEP mode. No = MC45 does not exit SLEEP mode. Table 10: Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes Event From SLEEP mode AT+CFUN=0 to AT+CFUN=1 From SLEEP mode AT+CFUN=5 or 6 to AT+CFUN=1 From SLEEP mode AT+CFUN=7 or 8 to AT+CFUN=1 Ignition line No No No /RTS0 or /RTS1 (falling edge) Yes No No Unsolicited Result Code (URC) Yes Yes No Incoming voice or data call Yes Yes No Any AT command (incl. outgoing voice or data call, outgoing SMS) Not possible (UART disabled) No No AT+CNMI=0,0 (= default, no indication of received SMS) No No No AT+CNMI=1,1 (= displays URC upon receipt of SMS) Yes Yes No GPRS data transfer Not possible (UART disabled) No No RTC alarm Yes Yes No AT+CFUN=1 Not possible (UART disabled) Yes Yes Incoming SMS depending on mode selected by AT+CNMI: Recommendation: · In NON-CYCLIC SLEEP mode, you can set an RTC alarm to wake up MC45 and return to full functionality. This is a useful approach because, in this mode, the AT interface is not accessible. MC45_HD_01_V00.02a Page 39 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.3.3 Turn off MC45 To switch the module off the following procedures may be used: · Normal shutdown procedure: Software controlled by sending the AT^SMSO command over the RS-232 application interface. See Chapter 3.3.3.1. · Emergency shutdown: Hardware driven by switching the /EMERGOFF line of the boardto-board connector to ground = immediate shutdown of supply voltages, only applicable if the software controlled procedure fails! See Chapter 3.3.3.2. · Automatic shutdown: Takes effect if undervoltage / overvoltage is detected or if battery or board (engine) temperature exceeds critical limit. See Chapter 3.3.4. 3.3.3.1 Turn off MC45 using AT command The best and safest approach to powering down MC45 is to issue the AT^SMSO command. This procedure lets MC45 log off from the network and allows the software to enter into a secure state and safe data before disconnecting the power supply. Before switching off the device sends the result code ^SMSO: MS is OFF From this moment on, no further AT commands can be executed. Only the RTC is still active. The mode is referred to as POWER DOWN mode. While MC45 is in POWER DOWN mode the application interface is switched off and must not be fed from any other source. Therefore, your application must be designed to avoid any current flow into any digital pins of the application interface. POWER DOWN is also signalized by the VDD pin, which in this mode, is off. MC45_HD_01_V00.02a Page 40 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.3.3.2 Emergency shutdown using /EMERGOFF pin Caution: Use the /EMERGOFF pin only when, due to serious problems, the software is not responding for more than 5 seconds. Pulling the /EMERGOFF pin causes the loss of all information stored in the volatile memory since power is cut off immediately. Therefore, this procedure is intended only for use in case of emergency, e.g. if MC45 fails to shut down properly. The /EMERGOFF signal is available on the board-to-board connector. To control the /EMERGOFF line it is recommended to use an open drain / collector driver. To turn the GSM engine off, the /EMERGOFF line has to be driven to ground for ³ 3.2s. BATT+ /IGT VDD Internal reset max. 3.2s /EMERGOFF generated by GSM engine generated by external application Figure 11: Deactivating GSM engine by /EMERGOFF signal MC45_HD_01_V00.02a Page 41 of 90 How does it work: · Voltage Vbatt+ is permanently applied to the module. · The module is active while the internal reset signal is kept at high level. During operation of MC45 the baseband controller generates watchdog pulses at regular intervals. Once the EMERGOFF pin is grounded these watchdog pulses are cut off from the power supply ASIC. The power supply ASIC shuts down the internal supply voltages of MC45 after max. 3.2s and the module turns off. Consequently, the output voltage at VDD is switched off. 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.3.4 Automatic shutdown To ensure proper operation of all assemblies under varying conditions, such as temperature, input voltage, transmission power etc., MC45 features protection elements for automatic shutdown. Automatic shutdown takes effect if · the MC45 board is exceeding the critical limits of overtemperature or undertemperature · the battery is exceeding the critical limits of overtemperature or undertemperature · undervoltage is detected · overvoltage is detected. The automatic shutdown procedure is equivalent to the power-down initiated with the AT^SMSO command, i.e. MC45 logs off from the network and the software enters a secure state avoiding loss of data. This is not applicable to overvoltage shutdown, where power is cut off immediately. Alert messages transmitted before the device switches off are implemented as Unsolicited Result codes (URCs). The presentation of these URCs can be enabled or disabled with the two AT commands AT^SBC and AT^SCTM. The URC presentation mode varies with the condition, please see Chapters 3.3.4.1 to 3.3.4.4 for details. For further instructions on AT commands refer to [1]. 3.3.4.1 Temperature dependent shutdown The board temperature is constantly monitored by an internal NTC resistor located on the PCB. The NTC that detects the battery temperature must be part of the battery pack circuit as described in Chapter 3.2.3. The values detected by either NTC resistor are measured directly on the board or the battery and therefore, are not fully identical with the ambient temperature. Proceeding from the measured temperature, MC45 sends an alert in the form of a URC and switches off when exceeding the critical limits: · URCs indicating the alert level "1" or "-1" allow you to take appropriate precautions, such as protect the module or battery from exposure to extreme conditions, or save or back up data etc. The presentation of the URCs depends on the settings selected with the AT^SCTM write command: AT^SCTM=1: Presentation of URCs is always enabled. AT^SCTM=0 (default): Presentation of URCs is enabled for 15 seconds time after start-up of MC45. After 15 seconds operation, the presentation will be disabled, i.e. no alert messages can be generated. · URCs indicating the alert level "2" or "-2" are followed by immediate shutdown. The presentation of these URCs is always enabled, i.e. they will be output even though the factory setting AT^SCTMC=0 was never changed. · When the temperature is back to normal, again a message will be delivered. In this case, the URC indicates level “0”. Table 11 summarizes the maximum ratings and the associated URCs. MC45_HD_01_V00.02a Page 42 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Table 11: Temperature dependent behaviour Sending temperature alert (15 s after start-up, otherwise only if URC presentation enabled) ^SCTM_A: 1 Caution: Tamb of battery close to overtemperature limit. ^SCTM_B: 1 Caution: Tamb of board close to overtemperature limit. ^SCTM_A: -1 Caution: Tamb of battery close to undertemperature limit. ^SCTM_B: -1 Caution: Tamb of board close to undertemperature limit. ^SCTM_A: 0 Battery back to uncritical temperature range. ^SBCTM_B: 0 Board back to uncritical temperature range. Automatic shutdown (URC appears no matter whether or not presentation was enabled) ^SCTM_A: 2 Alert: Tamb of battery equal or beyond overtemperature limit. MC45 switches off. ^SCTM_B: 2 Alert: Tamb of board equal or beyond overtemperature limit. MC45 switches off. ^SCTM_A: -2 Alert: Tamb of battery equal or below undertemperature limit. MC45 switches off. ^SCTM_B: -2 Alert: Tamb of board equal or below undertemperature limit. MC45 switches off. The values stated in Table 11 are based on test conditions according to IEC 60068-2-2 (still air). 3.3.4.2 Undervoltage shutdown if battery NTC is present In applications where the module’s charging technique is used and an NTC is connected to the BATT_TEMP terminal, the software constantly monitors the applied voltage to check that the battery voltage is sufficient to set up a call. When the battery voltage decreases to VBATT+<3.6V, the following URC will be presented: ^SBC: Undervoltage To enable or disable the URC use the AT^SBC command. The URC will be enabled when you enter the write command and specify the power consumption of your GSM application. Step by step instructions are provided in [1]. The message will be reported, for example, when you attempt to set up a call while the voltage is close to the critical limit and further power loss is caused during the transmit burst. To remind you that the battery needs to be charged soon, the URC appears several times before the module switches off. 3.3.4.3 Undervoltage shutdown if no battery NTC is present The undervoltage protection is also effective in applications, where no NTC connects to the BATT_TEMP terminal. Thus, you can take advantage of this feature even though the application handles the charging process or MC45 is fed by a fixed supply voltage. All you need to do is executing the write command AT^SBC= which automatically enables the presentation of URCs. You do not need to specify . Please note, that in contrast to applications with an NTC connected to BATT_TEMP, the module will present the URC ^SBC: Undervoltage only once and will then switch off without sending any further messages. MC45_HD_01_V00.02a Page 43 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.3.4.4 Shutdown in the event of overvoltage Overvoltage protection is implemented in the PSU-ASIC. If the supply voltage raises to VBATT+ > 5.8V MC45 switches off automatically. In contrast to undervoltage shutdown · there is no URC function available · and the module turns off immediately, i.e. loss of data cannot be avoided. Remark: The PA is always connected to the supply voltage, also in case of an emergency switch off. A higher supply voltage will destroy the PA. MC45_HD_01_V00.02a Page 44 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.3.5 Summary of state transitions Table 12: State transitions of MC45 The table shows how to proceed from one mode to another (gray column = present mode, white columns = intended modes) Further mode èèè **) *) Normal mode Charge-only mode Charging in normal *)**) mode --- /IGT >100 ms at low level Connect charger to POWER (high level at POWER) No direct transition, but Wake-up from POWER via “Charge-only mode” or DOWN mode (if “Normal mode” activated with AT+CALA) /IGT (if supply voltage is above 3.0V). No automatic transition, but via POWER DOWN mode without charger 100ms < /IGT < 500ms at low level /IGT >1 s at low level Present mode POWER DOWN mode without charger POWER DOWN --mode with charger (high level at POWER pins of MC45) **) Normal mode AT^SMSO --or exceptionally /EMERGOFF pin > 3.2s at low level *) Alarm mode POWER DOWN Wake-up from POWER DOWN mode (if activated with AT+CALA) No automatic transition, Connect charger to but via “POWER POWER pin at MC45 DOWN” (high level at POWER) AT+CALA followed by AT^SMSO. MC45 enters Alarm mode when specified time is reached. Disconnect charger (MC45 POWER pin at low level) or AT^SMSO or exceptionally /EMERGOFF pin >3.2s at low level No automatic transition, but via “Charge in Normal mode” --- /IGT >1s at low level AT+CALA followed by AT^SMSO. MC45 enters Alarm mode when specified time is reached and VBATT+<3.3V Charging in normal *) **) mode Via “Charge-only mode” or exceptionally /EMERGOFF pin >3.2s at low level Disconnect charger from POWER pin at MC45 AT^SMSO --- No direct transition Alarm mode AT^SMSO or /IGT >100ms at low exceptionally /EMERGOFF level pin >3.2s at low level No transition /IGT >100ms at low level --- Charge-only mode *) See Chapter 3.2.3.4 for details on the charging mode MC45_HD_01_V00.02a **) Normal mode covers TALK, DATA, GPRS, IDLE and SLEEP modes Page 45 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.4 RTC backup The internal Real Time Clock of MC45 is supplied from a separate voltage regulator in the power supply ASIC which is also active when MC45 is in POWER DOWN status. An alarm function is provided for activating and deactivating MC45. In addition, you can use the VDDLP pin on the board-to-board connector (pin no. 43) to backup the RTC from an external capacitor or a battery (rechargeable or non-chargeable). The capacitor is charged by the BATT+ line of MC45. If the voltage supply at BATT+ is disconnected the RTC can be powered by the capacitor. The size of the capacitor determines the duration of buffering when no voltage is applied to MC45, i.e. the greater capacitor the longer MC45 will save the date and time. The following figures show various sample configurations. The voltage applied at VDDLP can be in the range from 2 to 5.5V. Please refer to Table 19 for the parameters required. BATT+ Baseband processor B2B PSU 1k RTC VDDLP Figure 12: RTC supply from capacitor BATT+ Baseband processor B2B PSU 1k RTC VDDLP Figure 13: RTC supply from rechargeable battery BATT+ Baseband processor B2B PSU 1k RTC VDDLP Figure 14: RTC supply from non-chargeable battery MC45_HD_01_V00.02a Page 46 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.5 Serial interfaces MC45 offers two serial interfaces, each operating at 2.65V level. All RS-232 signals on the board-to-board connector are low active. Both interfaces are implemented as a serial asynchronous transmitter and receiver conforming to ITU-T RS-232 Interchange Circuits DCE. The GSM engine is designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals: RS-232(0) · Port /TXD @ application sends data to the module’s /TXD0 signal line · Port /RXD @ application receives data from the module’s /RXD0 signal line RS-232(1) · Port /TXD1 @ application sends data to module’s /TXD1 signal line · Port /RXD1 @ application receives data from the module’s /RXD1 signal line MC45 Application /TXD /RXD0 /RXD /RTS0 /RTS /CTS0 /CTS /DTR0 /DTR /DSR0 /DSR /DCD0 /DCD /RING0 /RING /TXD1 /TXD1 /RXD1 /RXD1 /RTS1 /RTS1 /CTS1 /CTS1 RS-232(1) interface RS-232(0) interface RS-232(1) interface /TXD0 RS-232(0) interface (DTE) (DCE) Figure 15: RS-232 interfaces MC45_HD_01_V00.02a Page 47 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY RS-232(0) Includes the data lines /TXD0 and /RXD0, the status lines /RTS0 and /CTS0 and, in addition, the modem control lines /DTR0, /DSR0, /DCD0 and /RING0. It is primarily designed for voice, CSD, fax and GPRS services and for controlling the GSM engine with AT commands. Full Multiplex capability allows the interface to be partitioned into three virtual channels, yet with CSD and fax services only available on the first logical channel. Please note that when the RS-232(0) runs in Multiplex mode, the RS-232(1) cannot be used. The /DTR0 signal will only be polled once per second from the internal firmware of MC45. The /RING0 signal serves to indicate incoming calls and other types of URCs (Unsolicited Result Code). RS-232(1) Includes only the data lines /TXD1 and /RXD1 plus /RTS1 and /CTS1 for hardware handshake. This interface is intended for voice calls, GPRS services and for controlling the GSM engine with AT commands. It is not suited for CSD call, fax calls and Multiplex mode. When a PPP connection is in progress, no URCs can be displayed. As a result, an incoming call or any other type of URC can only be indicated after the PPP connection was terminated. Both interfaces are configured for 8 data bits, no parity and 1 stop bit, and can be operated at bit rates from 300bps to 230kbps. Autobauding is only selectable on RS-232(0) and supports the following bit rates: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps. XON/XOFF software flow control can be used on both interfaces. MC45_HD_01_V00.02a Page 48 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.6 Audio interfaces MC45 comprises three audio interfaces available on the board-to-board connector: · Two analog audio interfaces, each with a balanced analog microphone input and a balanced analog earpiece output. The second analog interface provides a supply circuit to feed an active microphone. · Serial digital audio interface (DAI) using PCM (Pulse Code Modulation) to encode analog voice signals into digital bit streams. This means you can connect up to three audio devices in any combination, all at the same time. Using the AT^SAIC command you can easily switch back and forth. MICP1 MICN1 MICP2 ADC MICN2 EPP1 EPN1 DAC EPP2 DSP Air Interface EPN2 SCLK RXDDAI RFSDAI TXDDAI TFSDAI Digital Audio Interface (DAI) Figure 16: Audio block diagram MC45 offers six audio modes which can be selected with the AT^SNFS command, no matter which of the three interfaces is currently active. The electrical characteristics of the voiceband part vary with the audio mode. For example, sending and receiving amplification, sidetone paths, noise suppression etc. depend on the selected mode and can be altered with AT commands (except for mode 1). On each audio interface you can use all audio AT commands specified in [1] to alter parameters. The only exception are the DAC and ADC gain amplifier attenuation and which cannot be modified when the digital audio interface is used, since in this case the DAC and ADC are switched off. Please refer to Chapter 6.5 for specifications of the audio interface and an overview of the audio parameters. Detailed instructions on using AT commands are presented in the "MC45 AT Command Set" [1]. Table 31 on page 83 summarizes the characteristics of the various audio modes and shows what parameters are supported in each mode. MC45_HD_01_V00.02a Page 49 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY When shipped from factory, all audio parameters of MC45 are set to interface 1 and audio mode 1. This is the default configuration optimized for the Votronic HH-SI-30.3/V1.1/0 handset and used for type approving the Siemens reference configuration. Audio mode 1 has fix parameters which cannot be modified. To adjust the settings of the Votronic handset simply change to another audio mode. 3.6.1 Microphone circuit Interface 1 This interface has no microphone supply circuit and therefore, has an impedance of 50 kW. When connecting a microphone or another signal source to interface 1 you are required to add two 100 nF capacitors, one to each line. Interface 2 This interface comes with a microphone supply circuit and can be used to feed an active microphone. If you do not use it or if you want to connect another type of signal source, for example, an op amp or a dynamic microphone, it needs to be decoupled with capacitors. Figure 17 shows the microphone inputs at both analog interfaces of MC45. 2.65 V Power down MICP1 MICN1 Ri=50kΩ to ADC 1 kΩ 1 kΩ MICP2 10 µF MICN2 1 kΩ 1 kΩ Figure 17: Schematic of microphone inputs MC45_HD_01_V00.02a Page 50 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.6.2 Speech processing The speech samples from the ADC or DAI are handled by the DSP of the baseband controller to calculate e.g. amplifications, sidetone, echo cancellation or noise suppression depending on the configuration of the active audio mode. These processed samples are passed to the speech encoder. Received samples from the speech decoder are passed to the DAC or DAI after post processing (frequency response correction, adding sidetone etc.). Full rate, half rate, enhanced full rate, speech and channel encoding including voice activity detection (VAD) and discontinuous transmission (DTX) and digital GMSK modulation are also performed on the GSM baseband processor. Customer specific audio parameters can be evaluated by Siemens on customer request. These parameters can be downloaded to MC45 using an AT command. For further information refer to [6] or contact your Siemens distributor. 3.6.3 DAI timing To support the DAI function, MC45 integrates a simple five-line serial interface with one input data clock line (SCLK) and input / output data and frame lines (TXDDAI, TFSDAI, RXDDAI, RFSDAI). The serial interface is always active if the external input data clock SLCK is present, i.e. the serial interface is not clocked by the DSP of the MC45 baseband processor. SLCK must be supplied from the application and can be in a frequency range between 0.2 and 10 MHz. Serial transfer of 16-bit words is done in both directions. Data transfer to the application is initiated by the module through a short pulse of TFSDAI. The duration of the TFSDAI pulse is one SCLK period, starting at the rising edge of SLCK. During the following 16 SLCK cycles, the 16-bit sample will be transferred on the TXDDAI line. The next outgoing sample will be transferred after the next TFSDAI pulse which occurs every 125 µs. The TFSDAI pulse is the master clock of the sample transfer. From the rising edge of the TFSDAI pulse, the application has 100 µs to transfer the 16-bit input sample on the RXDDAI line. The rising edge of the RFSDAI pulse (supplied by the application) may coincide with the falling edge of TFSDAI or occur slightly later - it is only significant that, in any case, the transfer of the LSB input sample will be completed within the specified duration of 100 µs. Audio samples are transferred from the module to the application in an average of 125µs. This is determined by the 8kHz sampling rate, which is derived from and synchronized to the GSM network. As SLCK is independent of the GSM network, the distance between two succeeding sample transfers may vary about + 1 SLCK period. The application is required to adapt its sampling rate to the TFDSDAI rate. Failure to synchronize the timing between the module and the application may cause audible pops and clicks in a conversation The timing characteristics of both data transfer directions are shown in Figure 18 and Figure 19. MC45_HD_01_V00.02a Page 51 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Note: Before starting the data transfer the clock SCLK should be available for at least three cycles. After the transfer of the LSB0 the clock SCLK should be still available for at least three cycles. SLCK (input) Internal signal T = 100ns to 5,000 ns RFSDAI (input) RXDDAI (input) Flag Figure 18: DAI timing on transmit path SLCK (input) T = 100ns to 5,000 ns Internal signal TFSDAI (output) TXDDAI (output) Flag Figure 19: DAI timing on receive path MC45_HD_01_V00.02a Page 52 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.7 SIM interface The baseband processor has an integrated SIM interface compatible with the ISO 7816-3 IC Card standard. This is wired to the host interface (board-to-board connector) in order to be adapted to an external SIM card holder. Six pins on the board-to-board connector are reserved for the SIM interface. Further to the five wire SIM interface according to GSM 11.11, the CCIN pin has been added. The CCIN pin serves to detect mechanically whether or not a card is present in the card holder. To take advantage of this feature, an appropriate SIM card detect switch is required on the card holder. For example, this is true for the model supplied by Molex Deutschland GmbH, which has been tested to operate with MC45 and is part of the Siemens reference setup for type approval (Molex ordering number 91228-0001). It is recommended that the total cable length between the board-to-board connector pins on MC45 and the pins of the card holder does not exceed 200 mm in order to meet the specifications of 3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance. Note: Before removing the SIM card or inserting a new one be sure that the GSM engine has been powered down as described in Chapter 3.3.3.1. Otherwise, you run the risk of causing damage to the card, or losing data stored on the card. Table 13: Signals of the SIM interface (board-to-board connector) Signal name Description CCCLK Chipcard clock, various clock rates can be set in the baseband processor. CCVCC SIM supply voltage from PSU-ASIC CCIO Serial data line, input and output. CCRST Chipcard reset, provided by baseband processor. CCIN Input on the baseband processor for detecting the SIM card in the holder; if the SIM card is removed during operation the SIM interface shuts down immediately. This function is implemented to prevent destruction of the SIM card. Nevertheless, inserting or removing the SIM card during operation should be avoided (see Note above). IMPORTANT: The CCIN pin is solely intended for use with a SIM card. It must not be used for any other purposes. Failure to comply with this requirement may invalidate the type approval of MC45. CCGND Separate ground connection for SIM card to improve EMC. MC45_HD_01_V00.02a Page 53 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.7.1 Requirements for using the CCIN pin The module’s startup procedure involves a SIM card initialization performed within 1 second after getting started. A most important issue for reliable operation is whether the initialization procedure ends up with a high or low level of the CCIN signal: a) If, during startup of MC45, the CCIN signal on the SIM interface is high, then the status of the SIM card holder can be recognized each time the card is inserted or ejected. This can be easily achieved when the card holder comprises a card detect switch. The switch causes CCIN to go and stay high when the card is present. A low level of CCIN indicates that the holder is empty. In this case, the module keeps searching, at regular intervals, for the SIM card. Once the card is inserted, CCIN is taken high again. b) If, during startup of MC45, the CCIN signal is low, the module will also attempt to initialize the SIM card. In this case, the initialization will only be successful when the card is present. If the SIM card initialization has been done, but the card is no more operational or removed, then the module will never search again for a SIM card and only emergency calls can be made. It is strongly recommended to connect the contacts of the SIM card detect switch to the CCIN input and to the CCVCC output of the module as illustrated in the sample diagram in Figure 20. The additional switch in the CCIN line shown in Figure 20 is intended for debugging purposes only and is, normally, not required in your application. In special cases, the CCIN signal might be controlled by the host application. If so, be sure that the CCIN signal is low while the output voltage VDD is low, too. In particular, no voltage may be applied at the CCIN input, when MC45 is in POWER DOWN mode. Otherwise, proper operation of MC45 may be affected due to an electric leakage current flowing through the CCIN pin into the module. MC45_HD_01_V00.02a Page 54 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.7.2 Design considerations for SIM card holder The schematic below is a sample configuration that illustrates the Molex SIM card holder located on the DSB45 Support Box (evaluation kit used for type approval of the Siemens MC45 reference setup, see [4]). X503 is the designation used for the SIM card holder in [4]. Molex card holder GSM module Figure 20: SIM card holder of DSB45 Support Box Table 14 : Pin assignment of Molex SIM card holder on DSB45 Support Box Pin no. Signal name I/O Function CCVCC Supply voltage for SIM card, generated by the GSM engine CCRST Chip card reset, prompted by the GSM engine CCCLK Chip card clock CCGND Individual ground line for the SIM card to improve EMC CCVPP Not connected CCIO I/O Serial data line, bi-directional CCDET1 Connect to CCVCC CCDET2 Connects to the CCIN input of the GSM engine. Serves to recognize whether a SIM card is in the holder. Removing the SIM card during operation will immediately stop further transmission of signals to the card to protect the card from damage. Pins 1 through 6 are the minimum requirement according to the GSM Recommendations, while 7 and 8 are needed for the CCIN pin. Place the capacitors C1205 and C1206 (or instead one capacitor of 200nF) as close as possible to the pins 1 (CCVCC) and 4 (GND) of the card holder. Connect the capacitors to the pins via low resistance tracks. The X507 switch is not mandatory, but may be added to help the system integrator control the CCIN signal, e.g. for designing and testing purposes. When the switch is pushed open (3 is switched to 2), the line simulates an empty SIM card holder although the SIM is inserted. When closed (3 connected to 1), the line simulates that the SIM card is present. MC45_HD_01_V00.02a Page 55 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.7.3 Grounding the SIM interface To ground the SIM interface you can proceed from several approaches, depending on your individual application design. The following information is just one of several options you can apply: Potential equalization can best be achieved by applying a separate ground for the SIM interface. For example, the PCB of your application platform may be designed to include an extra ground plane for the SIM card reader, rather than connecting the CCGND pin of the board-to-board connector to the central ground on your application platform. For the SIM card ground plane, you can choose a capacitive or inductive coupling or a zero Ohm bridge. Often, a combination of capacitive and inductive coupling will yield best results. B2B connector It depends on your actual layout where to place these lines. For ease of planning and designing, you can simply place the required footprints at each side of the ground plane. This gives you the flexibility, when you test your equipment for ESD and EMC protection, to decide which of them to use, if at all. GSM engine Customer application CCGND GND GND CCGND SIM card reader CCGND GND Notes: This figure is only a simplified example to give you an idea where to place the lines. One capacitive / inductive coupling will do, if needed at all. GND Insulation Ground plane Figure 21: Connecting a separate ground for SIM interface MC45_HD_01_V00.02a Page 56 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.8 Control signals The following control signals are available (2.65V level). 3.8.1 Inputs Table 15: Input control signals of the MC45 module Signal Pin Pin status Function Remarks Ignition /IGT Falling edge Power up MC45 Left open or HiZ No operation Active low ³ 100ms (Open drain/collector driver to GND required in cellular device application). Note: If a charger and a battery is connected to the customer application the /IGT signal must be 1s minimum. Emergency shutdown /EMERGOFF Low Power down MC45 Left open or HiZ No operation Active low ³ 3.2s (Open drain/collector driver required in cellular device application). At the /EMERGOFF signal the watchdog signal of the GSM engine can be traced (see description in Table 19). (HiZ = high impedance) MC45_HD_01_V00.02a Page 57 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.8.2 Outputs 3.8.2.1 Synchronization signal The synchronization signal serves to indicate growing power consumption during the transmit burst. The signal is generated by the SYNC pin (pin number 32). Please note that this pin can adopt two different operating modes which you can select by using the AT^SSYNC command (mode 0 and 1). For details refer to the following chapter and to the "AT Command Set". To generate the synchronization signal the pin needs to be configured to mode 0 (= default). This setting is recommended if you want your application to use the synchronization signal for better power supply control. Your platform design must be such that the incoming signal accommodates sufficient power supply to the MC45 module if required. This can be achieved by lowering the current drawn from other components installed in your application. The characteristics of the synchronization signal are explained below. Table 16: MC45 synchronization signal (if SYNC pin is set to mode 0 via AT^SSYNC) Function Pin Pin status Description Synchronization SYNC Low No operation High Indicates increased power consumption during transmission. 1 Tx 577 µs every 4.616 ms 2 Tx 1154 µs every 4.616 ms Transmit burst SYNC signal *) 300 µs Figure 22: SYNC signal during transmit burst *) The duration of the SYNC signal is always equal, no matter whether the traffic or the access burst are active. MC45_HD_01_V00.02a Page 58 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.8.2.2 Using the SYNC pin to control a status LED As an alternative to generating the synchronization signal, the SYNC pin can be used to control a status LED on your application platform. To avail of this feature you need to set the SYNC pin to mode 1 by using the AT^SSYNC command. For details see the "AT Command Set". When controlled from the SYNC pin the LED can display the functions listed in Table 17. Table 17: Coding of the status LED LED mode Operating status Off MC45 is off or run in SLEEP, Alarm or Charge-only mode 600 ms On / 600ms Off No SIM card inserted or no PIN entered, or network search in progress, or ongoing user authentication, or network login in progress. 75 ms On / 3 s Off Logged to network (monitoring control channels and user interactions). No call in progress. 75 ms on / 75 ms Off / 75 ms On / One or more GPRS contexts activated. 3 s Off Flashing Indicates GPRS data transfer: When a GPRS transfer is in progress, the LED goes on within 1 second after data packets were exchanged. Flash duration is approximately 0.5 s. On Depending on type of call: Voice call: Connected to remote party. Data call: Connected to remote party or exchange of parameters while setting up or disconnecting a call. LED Off = SYNC pin low. LED On = SYNC pin high (if LED is connected as illustrated in Figure 23) To operate the LED a buffer, e.g. a transistor or gate, must be included in your application. A sample configuration can be gathered from Figure 23. Power consumption in the LED mode is the same as for the synchronization signal mode. For details see Table 19, SYNC pin. Figure 23: LED Circuit (Example) MC45_HD_01_V00.02a Page 59 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.8.2.3 Behaviour of the /RING0 line (RS-232(0) interface only) The /RING0 line is available on the RS-232(0) interface. Its behaviour depends on the type of the call received. · When a voice call comes in the /RING0 line goes low for 1s and high for another 4s. Every 5 seconds the ring string is generated and sent over the /RXD0 line. If there is a call in progress and call waiting is activated for a connected handset or handsfree device, the /RING0 line switches to ground in order to generate acoustic signals that indicate the waiting call. 4s 4s /RING0 1s Ring string 1s Ring string 1s Ring string Figure 24: Incoming voice call · Likewise, when a Fax or data call is received, /RING0 goes low. However, in contrast to voice calls, the line remains low. Every 5 seconds the ring string is generated and sent over the /RXD0 line. 5s 5s /RING0 Ring string Ring string Ring string Figure 25: Incoming data call · All types of unsolicited result codes (URCs) also cause the /RING0 line to go low, however for 1 second only. For example, the GSM engine may be configured to output a URC upon the receipt of an SMS. As a result, if this URC type was activated with AT+CNMI=1,1, each incoming SMS causes the /RING0 line to go low. For more detailed information on URCs please refer the "MC45 AT Command Set". /RING0 1s URC Table 18: MC45 ring signal Function Pin Status Description Ring indication /RING0 Indicates an incoming call or URC. If in SLEEP mode, the cellular device application is caused to wake up. No operation MC45_HD_01_V00.02a Page 60 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 3.9 Electrical specifications of the application interface Please note that the reference voltages listed in Table 14 are the values measured directly on the MC45 module. They do not apply to the accessories connected. If an input pin is specified for Vi,h,max = 3.3V, be sure never to exceed the stated voltage. The value 3.3V is an absolute maximum rating. The Hirose DF12C board-to-board connector on MC45 is a 50-pin double-row receptacle. The names and the positions of the pins can be seen from Figure 26 which shows the top view of MC45. 26 50 BATT+ GND BATT+ GND BATT+ GND BATT+ GND BATT+ GND VDD CHARGE /RING0 POWER /DSR0 VDDLP /RTS0 /TXD0 /DTR0 /TXD1 /RTS1 RXD0 /CTS0 RXD1 /CTS1 SYNC /DCD0 BATT_TEMP /EMERGOFF RFSDAI /IGT TXDDAI GND SCLK MICN1 TFSDAI MICP1 RXDDAI MICP2 CCGND MICN2 CCIN EPN1 CCRST EPP1 CCIO EPP2 CCVCC EPN2 CCCLK MC45_HD_01_V00.02a 25 Figure 26: Pin assignment (top view on MC45) Note: Pin numbers have changed since the first release of this document (MC45_HD_01_v0001). The positions of the pins are still the same. Page 61 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Table 19: Pin assignment and electrical description of application interface Function Signal name IO Signal form and level Comments Power supply BATT+ VI = 3.3V to 4.5V VInorm = 4.1V Inorm ≈ 2A, Imax < 3A (during Tx burst) 1 Tx, peak current 577µs every 4.616ms 2 Tx, peak current 1154µs every 4.616ms Power supply input. 5 BATT+ pins to be connected in parallel. 5 GND pins to be connected in parallel. The power supply must be able to meet the requirements of current consumption in a Tx burst (up to 3A). Sending with two timeslots doubles the duration of current pulses to 1154µs (every 4.616ms)! VImin = 3.0V VImax = 15V This line signalizes to the processor that the charger is connected. If unused keep pin open. GND Charge interface POWER BATT_TEMP CHARGE ICHARGE = -300µA ... -600µA @ 3V < VCHARGE < VLOAD This line is a current source for the charge FET with a 10kW resistance between gate and source. If unused keep pin open. External supply voltage VDD VDDmin = 2.84V, VDDmax = 2.96V Imax = -10mA CLmax = 1µF Supply voltage, e.g. for an external LED or level shifter. The external digital logic must not cause any spikes or glitches on voltage VDD. Not available in POWER DOWN mode. VDD signalizes the “ON” state of the module. If unused VDD keep pin open. VDD Low Power VDDLP I/O RI =1kW VOmax ≈ 4.0V Supplies the RTC with power via an external capacitor or buffer battery if no VBATT+ is applied. If unused keep pin open. Connect NTC with RNTC ≈ 10kW @ 25°C to ground. VImin = 2.2V, VImax = 5.5V IItyp = 10µA at BATT+ = 0V Mobile in POWER DOWN mode: VImin = 1.2V MC45_HD_01_V00.02a Page 62 of 90 Input to measure the battery temperature over NTC resistor. NTC should be installed inside or near battery pack to enable the charging algorithm and deliver temperature values. If unused keep pin open. 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Function Signal name IO Signal form and level Comments Ignition /IGT RI ≈ 100kW, CI ≈ 1nF VILmax = 0.5V at Imax = -20µA VOpenmax = 2.3V Input to switch the mobile ON. The line must be driven low by an Open Drain or Open Collector driver. ON Emergency shutdown (Watchdog) /EMERGOFF ~~~ |____| ~~~ Active Low ³ 100ms RI ≈22kW VILmax = 0.5V at Imax = -100µA VOpenmax = 2.73V Signal ~~~ |______| ~~~ Active Low ³ 3.2s Watchdog: VOLmax = 0.35V at I = 10µA VOHmin= 2.25V at I = -10µA fOmin = 0.16Hz fOmax = 1.55Hz Synchronization SYNC VOLmax = 0.2V at I = 1mA VOHmin = 2.35V at I = -1mA VOHmax = 2.73V 1 Tx, 877µs impulse each 4.616ms and 2 Tx, 1454µs impulse each 4.616ms, with 300µs forward time. SIM interface CCIN This line must be driven by an Open Drain or Open Collector driver. Emergency shutdown deactivates the power supply to the module. The module can be reset if /IGT is activated after emergency shutdown. To switch the mobile off use the AT^SMSO command. /EMERGOFF also indicates the internal watchdog function. If unused keep pin open. Indicates increased current consumption during uplink transmission burst. Note that timing is different during handover. Alternatively used to control status LED. If unused keep pin open. RI ≈ 100kW VILmax = 0.5V VIHmin = 2.15V at I = 20µA, VIHmax=3.3V at I = 30µA CCIN = high, SIM card holder closed (no card recognition) CCRST RO ≈47W VOLmax = 0.25V at I = 1mA VOHmin = 2.3V at I = -1mA VOHmax = 2.73V CCIO IO RI ≈10kW VILmax = 0.5V VIHmin = 1.95V, VIHmax=3.3V Maximum cable length 200mm to SIM card holder. All signals of SIM interface are protected against ESD with a special diode array. Usage of CCGND is mandatory. See Chapter 3.7.3 for details on grounding. RO ≈220W VOLmax = 0.4V at I = 1mA VOHmin = 2.15V at I = -1mA VOHmin = 2.55V at I = -20µA VOHmax = 2.96V CCCLK RO ≈220W VOLmax = 0.4V at I = 1mA VOHmin = 2.15V at I = -1mA VOHmax = 2.73V CCVCC ROmax = 5W CCVCCmin = 2.84V, CCVCCmax = 2.96V Imax = -20mA CCGND MC45_HD_01_V00.02a Ground Page 63 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Function Signal name IO Signal form and level Comments RS-232 (0) interface /RXD0 /TXD0 First serial interface for AT commands or data stream. /CTS0 VOLmax = 0.2V at I = 1mA VOHmin = 2.35V at I = -1mA VOHmax = 2.73V /RTS0 /DTR0 /DCD0 /DSR0 /RING0 /RXD1 /TXD1 /CTS1 /RTS1 RFSDAI RXDDAI SCLK TFSDAI TXDDAI RS-232 (1) interface Digital audio interface EPP1 EPN1 MICP1 MICN1 MICP2 MICN2 Explanation of signal names: P = positive, N = negative Analog audio EPP2 interfaces EPN2 VILmax = 0.5V VIHmin = 1.95V, VIHmax=3.3V /DTR0, RTS0: Imax = -90µA at VIN = 0V /TXD0: Imax = -260µA at VIN = 0V VOLmax = 0.2V at I = 1mA VOHmin = 2.35V at I = -1mA VOHmax = 2.73V VILmax = 0.5V VIHmin = 1.95V, VIHmax=3.3V IImax = -90µA at VIN = 0V If unused keep pins open. Second serial interface for AT commands. Please note that the /TXD1 pin draws, for 350ms, an additional current of max. 60µA when MC45 is activated. See timing characteristics in Figure 6 If unused keep pins open. VOLmax = 0.2V at I = 1mA VOHmin = 2.35V at I = -1mA VOHmax = 2.73V If unused keep pins open. VILmax = 0.5V VIHmin = 1.95V, VIHmax=3.3V IImax = 330µA at VIN = 3.3V VOmax = 3.7Vpp See also Table 32. The audio output is balanced and can directly operate an earpiece. If unused keep pins open. VOmax = 3.7Vpp See also Table 32. Balanced audio output. Can be used to directly operate an earpiece. If unused keep pins open. RI ≈ 50kW differential VImax = 1.03Vpp See also Table 33. Balanced microphone input. To be decoupled with 2 capacitors (CK = 100nF), if connected to a microphone or another device. If unused keep pins open. RI = 2kW differential VImax = 1.03Vpp See also Table 33. Balanced microphone input. Can be used to directly feed an active microphone. If used for another signal source, e.g. op amp, to be decoupled with capacitors. If unused keep pins open. AGND MC45_HD_01_V00.02a Please note that the /TXD0 pin draws, for 350ms, an additional current of max. 60µA when MC45 is activated. See timing characteristics in Figure 6 Separate ground connection for external audio circuits. Page 64 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 4 Antenna interface (antenna reference point – ARP) To suit the physical design of individual applications MC45 offers two alternative approaches to connecting the antenna: The standard layout of MC45 comprises an antenna connector from Hirose assembled on the component side of the PCB (top view on MC45) plus a antenna pad placed on the bottom side. Both solutions can only be applied alternatively: Whenever an antenna is plugged to the Hirose connector, the pad must not be used. Vice versa, if the antenna is soldered to the pad, then the Hirose connector must be left empty. Both RF interfaces have an impedance of 50Ω. MC45 is capable of sustaining a total mismatch at the antenna connector or pad without any damage, even when transmitting at maximum RF power. To help you choose an appropriate antenna, Chapters 5.4 and 8 provide technical specifications and ordering information. The external antenna must be matched properly to achieve best performance regarding radiated power, DC-power consumption and harmonic suppression. Matching networks are not included on the MC45 PCB and should be placed in the host application. Regarding the return loss MC45 provides the following values: Table 20: Return loss State of module Return loss of module Recommended return loss of application Receive > 8dB > 12dB Transmit not applicable > 12dB Idle < 5dB not applicable MC45_HD_01_V00.02a Page 65 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 5 Physical characteristics 5.1 Mechanical dimensions of MC45 Figure 27 shows the top view on MC45 and provides an overview of the mechanical dimensions of the board. For further details see Figure 28. Size: 53 +0.2 x 34 +0.2 x 3.5+0.3 mm Weight: 10g Figure 27: MC45 – top view MC45_HD_01_V00.02a Page 66 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Board-to-board connector MC45 All dimensions in millimeter Figure 28: Mechanical dimensions of MC45 MC45_HD_01_V00.02a Page 67 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Ø1 .1 Ground pad, e.g. for heat dissipator or connection to host device TP 402 14.42 4.75 0.00 0.00 15.50 TP GND 24.40 26.90 10.60 TP BATT+ Figure 29: MC45 bottom view MC45_HD_01_V00.02a Page 68 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 5.2 Mounting MC45 onto the application platform There are many ways to properly install MC45 in the host device. An efficient approach is to mount the MC45 PCB to a frame, plate, rack or chassis. Fasteners can be M1.6 or M1.8 screws plus suitable washers, circuit board spacers, or customized screws, clamps, or brackets. In addition, the board-to-board connection can also be utilized to achieve better support. If the bottom of MC45 faces the holding device, only use the ground pad for the connection. To avoid short circuits ensure that the remaining sections of the MC45 PCB do not come into contact with the host device since there are a number of test points. The ground pad can also be used to attach cooling elements, e.g. a heat sink. Figure 29 shows the ground pad on the bottom of MC45 and the positions of all test points. Particular attention should be paid to the test point TP 402. Placed beneath the ground pad it has been added for manufacturing only. When the pad is used for grounding the unit or connecting a heat sink, extra care must be taken not to contact this test point. The antenna pad on the bottom of the MC45 PCB must not be influenced by any other PCBs, components or by the housing of the host device. It needs to be surrounded by a restricted space as described in Chapter 5.4.2. To prevent mechanical damage, be careful not to force, bend or twist the module. Be sure it is positioned flat against the host device. Note: Detailed mounting instructions and recommendations for integrating MC45 into the host application shall be provided in later releases of this document. MC45_HD_01_V00.02a Page 69 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 5.3 Board-to-board connector This chapter provides specifications for the 50-pin board-to-board connector which serves as physical interface to the host application. The receptacle assembled on the MC45 PCB is type Hirose DF12C. Mating headers from Hirose are available in different stacking heights. Figure 30: Hirose DF12C receptacle on MC45 Figure 31: Header Hirose DF12 series Table 21: Ordering information DF12 series Item Part number Stacking height (mm) HRS number Receptacle on MC45 DF12C(3.0)-50DS-0.5V(81) 3-5 537-0694-9-81 Headers DF12 series DF12E(3.0)-50DP-0.5V(81) 3.0 537-0834-6-** DF12E(3.5)-50DP-0.5V(81) 3.5 537-0534-2-** DF12E(4.0)-50DP-0.5V(81) 4.0 537-0559-3-** DF12E(5.0)-50DP-0.5V(81) 5.0 537-0584-0-** Notes: The headers listed above are without boss and metal fitting. Please contact Hirose for details on other types of mating headers. Asterixed HRS numbers denote different types of packaging. Table 22: Electrical and mechanical characteristics of the Hirose DF12C connector Parameter Specification (50 pin Board to Board connector) Number of Contacts 50 Quantity delivered 2000 Connectors per Tape & Reel Voltage 50V Current Rating 0.5A max per contact Resistance 0.05 Ohm per contact Dielectric Withstanding Voltage 500V RMS min Operating Temperature -45°C...+125°C Contact Material phosphor bronze (surface: gold plated) Insulator Material PA , beige natural Stacking height 3.0 mm ; 3.5 mm ; 4.0 mm ; 5.0 mm Insertion force 21.8N Withdrawal force 1st 10N Withdrawal force 50th 10N Maximum connection cycles 50 MC45_HD_01_V00.02a Page 70 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 5.3.1 Mechanical dimensions of the Hirose DF12 connector Figure 32: Mechanical dimensions of Hirose DF12 connector 5.3.2 Adapter cabling The board-to-board connection is primarily intended for direct contact between both connectors. If this assembly solution does not fit into your application design ensure that the used adapter cable meets the following requirements: · · Maximum length: 200 mm Type of cable: Flexible cable or flexible printed circuit board designed to mate with the Hirose receptacle and headers specified above. The equipment submitted for type approving the Siemens reference setup of MC45 includes a 160mm adapter cable. See Chapter 7.1. MC45_HD_01_V00.02a Page 71 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 5.4 Antenna design This chapter describes the various options of connecting an external antenna to MC45. Be sure that all peripherals are applied according to the manufacturer’s antenna specifications. For internal antenna equipment, you are advised to use the services of a consultant or fullservice house. 5.4.1 Hirose antenna connector MC45 uses an ultra-miniature SMT antenna connector supplied from Hirose Ltd. The product name is: U.FL-R-SMT The position of the antenna connector on the MC45 board can be seen in Figure 28. Figure 33: Mechanical dimensions of U.FL-R-SMT connector Table 23: Product specifications of U.FL-R-SMT connector Item Specification Conditions Nominal impedance 50 W Rated frequency DC to 3 GHz Operating temp:-40°c to + 90°C Operating humidity: max. 90% Ratings Mechanical characteristics Female contact holding force 0.15 N min Measured with a Æ 0.475 pin gauge Repetitive operation Contact resistance: Center 25 mW Outside 15mW 30 cycles of insertion and disengagement Vibration No momentary disconnections of 1 µs; No damage, cracks and looseness of parts Frequency of 10 to 100 Hz, single amplitude of 1.5 mm, acceleration of 59 m/s2, for 5 cycles in the direction of each of the 3 axes Shock No momentary disconnections of Acceleration of 735 m/s2, 11 ms 1 µs. duration for 6 cycles in the No damage, cracks and looseness direction of each of the 3 axes of parts. Environmental characteristics Humidity resistance MC45_HD_01_V00.02a No damage, cracks and looseness Exposure to 40°C, humidity of of parts. 95% for a total of 96 hours Insulation resistance: 100 MW min. at high humidity 500 MW min when dry Page 72 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Temperature cycle No damage, cracks and looseness of parts. Contact resistance: Center 25 mW Outside 15mW Temperature: +40°C ® 5 to 35°C ® +90°C ® 5 to 35°C Time: 30 min. ® within 5 min. ® 30 min. within 5 min Salt spray test No excessive corrosion 48 hours continuous exposure to 5% salt water Table 24: Material and finish of U.FL-R-SMT connector and recommended plugs Part Material Finish Shell Phosphor bronze Silver plating Male center contact Brass Gold plating Female center contact Phosphor bronze Gold plating Insulator Plug: Receptacle: PBT LCP Black Beige Mating plugs and cables can be chosen from the Hirose U.FL Series. Examples are shown below and listed in Table 25. For latest product information please contact your Hirose dealer or visit the Hirose home page, for example http://www.hirose.com. Figure 34: U.FL-R-SMT connector with U.FL-LP-040 plug Figure 35: U.FL-R-SMT connector with U.FL-LP-066 plug MC45_HD_01_V00.02a Page 73 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY In addition to the connectors illustrated above, the U.FL-LP-(V)-040(01) version is offered as an extremely space saving solution. This plug is intended for use with extra fine cable (up to Æ 0.81 mm) and minimizes the mating height to 2 mm. See Figure 36 which shows the Hirose datasheet. Figure 36: Specifications of U.FL-LP-(V)-040(01) plug MC45_HD_01_V00.02a Page 74 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Table 25: Ordering information for Hirose U.FL Series Item Part number HRS number Connector on MC45 U.FL-R-SMT CL331-0471-0-10 Right-angle plug shell for Æ 0.81 mm cable U.FL-LP-040 CL331-0451-2 Right-angle plug for Æ 0.81 mm cable U.FL-LP(V)-040 (01) CL331-053-8-01 Right-angle plug for Æ 1.13 mm cable U.FL-LP-066 CL331-0452-5 Right-angle plug for Æ 1.32 mm cable U.FL-LP-066 CL331-0452-5 Extraction jig E.FL-LP-N CL331-04441-9 5.4.2 Antenna pad The antenna pad on the bottom of the MC45 PCB must not come into contact with the holding device or any other components of the host application. The pad must be a surrounded by a restricted area filled with air, which must also be reserved 0.8 mm in height. Hirose antenna connector RF section MC45 PCB Antenna pad Restricted area Figure 37: Restricted area around antenna pad MC45_HD_01_V00.02a Page 75 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6 Electrical, reliability and radio characteristics 6.1 Absolute maximum ratings Absolute maximum ratings for supply voltage and voltages on digital and analog pins of MC45 are listed in Table 26. Exceeding these values will cause permanent damage to MC45. The power supply shall be compliant with the SELV safety standard defined in EN60950. The supply current must be limited according to Table 26. Table 26: Absolute maximum ratings Parameter Min Max Unit Peak current of power supply 4.0 RMS current of power supply (during one TDMA-frame) 0.7 Voltage at digital pins -0.3 3.3 Voltage at analog pins -0.3 3.0 Voltage at digital / analog pins in POWER DOWN mode -0.25 +0.25 Voltage at POWER pin 15 Voltage at CHARGE pin 15 Differential load resistance between EPNx and EPPx 15 6.2 Operating temperatures Test conditions were specified in accordance with IEC 60068-2 (still air). Table 27: Operating temperatures Parameter Ambient temperature (according to GSM 11.10) Restricted operation *) Min Typ Max Unit -20 25 55 °C -25 to -20 55 to 70 °C -29 -18 >70 >60 °C °C +45 °C Automatic shutdown MC45 board temperature Battery temperature Charging temperature (software controlled fast charging) *) **) **) MC45 works, but deviations from the GSM specification may occur. Tamb max = 70°C, conditions: GSM 900 PCL and VBATT+ max <4.0V MC45_HD_01_V00.02a Page 76 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6.3 Reliability characteristics The test conditions stated below are an extract of the complete test specifications. Table 28: Summary of reliability test conditions Type of test Conditions Standard Vibration Frequency range: 10-20 Hz; acceleration: 3.1mm amplitude DIN IEC 68-2-6 Frequency range: 20-500 Hz; acceleration: 5g Duration: 2h per axis = 10 cycles; 3 axes Shock half-sinus Acceleration: 500g DIN IEC 68-2-27 Shock duration: 1msec 1 shock per axis 6 positions (± x, y and z) Dry heat Temperature: +70 ±2°C Test duration: 16 h EN 60068-2-2 Bb ETS 300019-2-7 Humidity in the test chamber: < 50% Temperature change (shock) Low temperature: -40°C ±2°C DIN IEC 68-2-14 Na High temperature: +85°C ±2°C Changeover time: < 30s (dual chamber system) ETS 300019-2-7 Test duration: 1 h Number of repetitions: 100 Damp heat cyclic High temperature: +55°C ±2°C DIN IEC 68-2-30 Db Low temperature: +25°C ±2°C Humidity: 93% ±3% ETS 300019-2-5 Number of repetitions: 6 Test duration: 12h + 12h Cold (constant exposure) Temperature: -40 ±2°C DIN IEC 68-2-1 Test duration: 16 h MC45_HD_01_V00.02a Page 77 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6.4 Power supply ratings Table 29: Power supply ratings Parameter Description Conditions BATT+ Reference points on MC45: TP BATT+ and TP GND Supply voltage Min 3.3 Typ Max 4.1 Unit 4.5 400 mV Voltage must stay within the min/max values, including voltage drop, ripple, spikes. Voltage drop during transmit burst Normal condition, power control level for Pout max Voltage ripple Normal condition, power control level for Pout max mV @ f<200kHz 50 @ f>200kHz IBATT+ Average supply 3) current POWER DOWN mode 50 µA SLEEP mode @ DRX = 6 TBD mA IDLE mode EGSM 900 TBD mA GSM 1800/1900 TBD 1) TALK mode EGSM 900 300 2) GSM 1800/1900 IDLE GPRS TBD GSM 1800/1900 TBD 360 2) GSM 1800/1900 DATA mode GPRS, 1) (3 Rx, 2 Tx) EGSM 900 GSM 1800/1900 Peak supply current Power level (during 577µs transmission slot every 4.6ms) 1) Power control level PCL 5 2) Power control level PCL 0 3) All average supply current values @ IVDD = 0mA Page 78 of 90 mA mA 460 mA 330 TBD 2) 1) 400 270 EGSM 900 DATA mode GPRS, 1) (4 Rx, 1 Tx) EGSM 900 MC45_HD_01_V00.02a 100 mA TBD 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6.4.1 Current consumption during transmit burst The diagrams provided in Figure 38 and Figure 39 illustrate the typical current consumption of the application caused during a transmit burst. The typical peak current is shown vs. the power level for 900 MHz, 1800 MHz and 1900 MHz and vs. the return loss of the antenna. Test conditions: All measurements have been performed at Tamb= 25°C, VBATT+ nom = 4.1V. The reference points used on MC45 are the BATT+ and GND contacts (test points are shown in Figure 29). All curves are for one TX slot, that is, for example, a voice call, CSD call or Class 8 GPRS. Figures for Class 10 GPRS activities will be published in later releases of this document. Changing the conditions, e.g. in terms of temperature or voltage, will cause different results. The current will be maximized when the maximum supply voltage is used together with a total reflection at the RF interface. PCS PCS 1200 200 180 160 Avg Current (mA) Burst Current (mA) 1000 800 600 400 140 120 100 80 60 40 200 20 10 12 14 16 10 12 14 16 10 12 14 16 Power Level Power Level PCN PCN 1400 250 1200 Avg Current (mA) Burst Current (mA) 200 1000 800 600 400 150 100 50 200 10 12 14 16 Power Level GSM GSM 1800 300 1600 250 Avg Current (mA) 1400 Burst Current (mA) Power Level 1200 1000 800 600 200 150 100 400 50 200 11 13 15 17 19 21 11 13 15 17 19 21 Power Level Power Level Test conditions: Tamb= 25°C, VBATT+ nom = 4.1V measured at TP BATT+ and GND, 1 TX slot Figure 38: Typical current consumption vs. power level MC45_HD_01_V00.02a Page 79 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Burst Current : GSM Ch50 Average Current : GSM Ch50 3500 500 450 3000 Current (mA) Pw rClass5 2000 Pw rClass10 1500 Pw rClass15 Pw rClass19 1000 Current (mA) 400 2500 350 Pw rClass5 300 Pw rClass10 250 Pw rClass15 200 Pw rClass19 150 100 500 50 10 20 30 40 10 20 30 40 Return Loss (dB) Return Loss (dB) Burst Current : PCN Ch711 Average Current : PCN Ch711 300 1600 1400 250 Pw rClass0 1000 Pw rClass5 800 Pw rClass10 600 Pw rClass15 Current (mA) Current (mA) 1200 200 Pw rClass0 Pw rClass5 150 Pw rClass10 100 Pw rClass15 400 50 200 10 20 30 40 10 20 30 40 Return Loss (dB) Return Loss (dB) Burst Current : PCS Ch761 Average Current : PCS Ch761 250 1600 1400 200 Pw rClass0 1000 Pw rClass5 800 Pw rClass10 600 Pw rClass15 400 Current (mA) Current (mA) 1200 Pw rClass0 150 Pw rClass5 Pw rClass10 100 Pw rClass15 50 200 10 20 30 40 Return Loss (dB) 10 20 30 40 Return Loss (dB) Test conditions: Tamb= 25°C, VBATT+ nom = 4.1V measured at TP BATT+ and GND, 1 TX slot Figure 39: Typical current consumption vs. return loss MC45_HD_01_V00.02a Page 80 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6.5 Electrical characteristics of the voiceband part 6.5.1 Setting audio parameters by AT commands The audio modes 2 to 6 can be adjusted according to the parameters listed below. Each audio mode is assigned a separate set of parameters. Table 30: Audio parameters adjustable by AT command Parameter Influence to Range Gain range Calculation inBbcGain MICP/MICN analogue amplifier gain of baseband controller before ADC 0...7 0...42dB 6dB steps inCalibrate digital attenuation of input signal after ADC 0...32767 -∞...0dB 20 * log (inCalibrate/ 32768) outBbcGain EPP/EPN analogue output gain of baseband controller after DAC 0...3 6dB steps outCalibrate[n] n = 0...4 digital attenuation of output signal after speech decoder, before summation of sidetone and DAC 0...32767 -∞...+6dB 20 * log (2 * outCalibrate[n]/ 32768) 0...32767 -∞...0dB 20 * log (sideTone/ 32768) 0...-18dB present for each volume step[n] sideTone digital attenuation of sidetone is corrected internally by outBbcGain to obtain a constant sidetone independent of output volume Note: The parameters inCalibrate, outCalibrate and sideTone accept also values from 32768 to 65535. These values are internally truncated to 32767. MC45_HD_01_V00.02a Page 81 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6.5.2 Audio programming model The audio programming model shows how the signal path can be influenced by varying the AT command parameters. The model is the same for all three interfaces, except for the parameters and which cannot be modified on the digital audio interface is being used, since in this case the DAC is switched off. The parameters inBbcGain and inCalibrate can be set with AT^SNFI. All the other parameters are adjusted with AT^SNFO. 2,65V 1k MIC2 inCalibrate 1k -¥...0dB 10uF 1k +0..42dB in 6dB-steps 1k inBbcGain speechcoder sideTone (0dB; -6db, 12dB; -18dB) speechdecoder outCalibrate[n] n = 0...4 outBbcGain AT parameter Figure 40: AT audio programming model MC45_HD_01_V00.02a Page 82 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6.5.3 Characteristics of audio modes The electrical characteristics of the voiceband part depend on the current audio mode set with the AT^SNFS command. Table 31: Voiceband characteristics (typical), all values preliminary Audio mode no. AT^SNFS= 1 (Default settings, not adjustable) Name Default Handset Basic Handsfree Headset User Handset Plain Codec 1 Plain Codec 2 Purpose DSB with M20T handset Siemens Car Kit Portable Siemens Headset DSB with individual handset Direct access to speech coder Direct access to speech coder Gain setting via AT command. Defaults: inBbcGain outBbcGain Fix Adjustable Adjustable Adjustable Adjustable Adjustable 4 (24dB) 1 (-6dB) 2 (12dB) 1 (-6dB) 5 (30dB) 2 (-12dB) 4 (24dB) 1 (-6dB) 0 (0dB) 0 (0dB) 0 (0dB) 0 (0dB) Default audio interface Power supply ON ON ON ON OFF OFF Sidetone ON --- Adjustable Adjustable Adjustable Adjustable Volume control OFF Adjustable Adjustable Adjustable Adjustable Adjustable Limiter (receive) ON ON ON ON --- --- --- --- --- --- ON --- --- --- 1) 4) Compressor (receive) --- ON AGC (send) --- --- Echo control (send) Suppression Cancellation + --suppression Suppression --- --- --- up to 10dB 10dB --- --- --- MIC input signal for 0dBm0 @ 1024 Hz (default gain) 23mV 58mV 7.5mV @ 23mV -3dBm0 due to AGC 315mV 315mV EP output signal in mV rms. @ 0dBm0, 1024 Hz, no load (default gain); @ 3.14 dBm0 284mV 120mV default @ max volume 300mV 284mV default @ default @ max volume max volume 895mV 895mV 3.7Vpp 3.7Vpp Sidetone gain at default settings 22.8dB 0dB sideTone 3) = 8192 0dB sideTone 3) = 8192 Noise suppression 1) 2) 3) 4) 2) -∞ dB Affected by AGC, 13dB @ 7.5mV (MIC) 22.8dB Adaptive, receive volume increases with higher ambient noise level. In audio modes with noise reduction, the microphone input signal for 0dBm0 shall be measured with a sine burst signal for a tone duration of 5 seconds and a pause of 2 sec. The sine signal appears as noise and, after approx. 12 sec, is attenuated by the noise reduction by up to 10dB. See AT^SNFO command in [1]. Audio mode 5 and 6 are identical. With AT^SAIC, you can easily switch mode 5 to the second interface. Therefore, audio mode 6 is only kept for compatibility to earlier Siemens GSM products. MC45_HD_01_V00.02a Page 83 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Note: With regard to acoustic shock, the cellular application must be designed to avoid sending false AT commands that might increase amplification, e.g. for a high sensitive earpiece. A protection circuit should be implemented in the cellular application. 6.5.4 Voiceband receive path Test conditions: · The values specified below were tested to 1kHz and 0dB gain stage, unless otherwise stated. · Parameter setup: gs = 0dB means audio mode = 5 for EPP1 to EPN1 and 6 for EPP2 to EPN2, inBbcGain= 0, inCalibrate = 32767, outBbcGain = 0, OutCalibrate = 16384, sideTone = 0. Table 32: Voiceband receive path Parameter Min Typ Max Unit Test condition / remark Differential output voltage (peak to peak) 3.33 3.7 4.07 from EPPx to EPNx gs = 0dB @ 3.14 dBm0 no load Differential output gain settings (gs) at 6dB stages (outBbcGain) -18 dB Set with AT^SNFO Fine scaling by DSP (outCalibrate) -∞ dB Set with AT^SNFO 100 mV gs = 0dB, outBbcGain = 0 and -6dB Ω from EPPx to EPNx Output differential DC offset Differential output resistance Differential load capacitance 1000 pF from EPPx to EPNx Absolute gain accuracy 0.8 dB Variation due to change in temperature and life time Attenuation distortion dB for 300...3900Hz, @ EPPx/EPNx (333Hz) / @ EPPx/EPNx (3.66kHz) Out-of-band discrimination 60 dB for f > 4kHz with in-band test signal@ 1kHz and 1kHz RBW gs = gain setting MC45_HD_01_V00.02a Page 84 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6.5.5 Voiceband transmit path Test conditions: · The values specified below were tested to 1kHz and 0dB gain stage, unless otherwise stated. · Parameter setup: Audio mode = 5 for MICP1 to MICN1 and 6 for MICP2 to MICN2, inBbcGain= 0, inCalibrate = 32767, outBbcGain = 0, OutCalibrate = 16384, sideTone = 0 Table 33: Voiceband transmit path Parameter Min Typ Input voltage (peak to peak) Max Unit 1.03 Test condition/Remark MICP1 to MICN1, MICP2 to MICN2 Input amplifier gain in 6dB steps (inBbcGain) 42 dB Set with AT^SNFI Fine scaling by DSP (inCalibrate) -∞ dB Set with AT^SNFI Input impedance MIC1 50 kΩ Input impedance MIC2 2.0 kΩ Microphone supply voltage ON Ri = 4kΩ Microphone supply voltage OFF ; Ri = 4kΩ 2.57 2.17 1.77 2.65 2.25 1.85 2.73 2.33 1.93 Microphone supply in POWER DOWN mode MC45_HD_01_V00.02a no supply current @ 100µA @ 200µA See Figure 17 Page 85 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6.6 Air interface Test conditions: All measurements have been performed at Tamb= 25°C, VBATT+ nom = 4.1V. The reference points used on MC45 are the BATT+ and GND contacts (test points are shown in Figure 29). Table 34: Air Interface Parameter Min Typ Max Unit Frequency range E-GSM 900 880 915 MHz Uplink (MS ® BTS) GSM 1800 1710 1785 MHz GSM 1900 1850 1910 MHz Frequency range E-GSM 900 925 960 MHz Downlink (BTS ® MS) GSM 1800 1805 1880 MHz GSM 1900 1930 1990 MHz E-GSM 900 31 33 35 dBm GSM 1800 28 30 32 dBm GSM 1900 28 30 32 RF power @ ARP with 50Ω load Number of carriers Duplex spacing E-GSM 900 174 GSM 1800 374 GSM 1900 299 E-GSM 900 45 MHz GSM 1800 95 MHz GSM 1900 80 Carrier spacing 200 Multiplex, Duplex kHz TDMA / FDMA, FDD Time slots per TDMA frame Frame duration 4.615 ms Time slot duration 577 µs Modulation GMSK Receiver input sensitivity @ ARP E-GSM 900 -102 -105 dBm BER Class II < 2.4% GSM 1800 -102 -105 dBm GSM 1900 -102 -105 dBm MC45_HD_01_V00.02a Page 86 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 6.7 Electrostatic discharge The GSM engine is not protected against Electrostatic Discharge (ESD) in general. Consequently, it is subject to ESD handling precautions that typically apply to ESD sensitive components. Proper ESD handling and packaging procedures must be applied throughout the processing, handling and operation of any application that incorporates a MC45 module. Special ESD protection provided on MC45: Antenna interface: one spark discharge line (spark gap) SIM interface: clamp diodes for protection against overvoltage. The remaining ports of MC45 are not accessible to the user of the final product (since they are installed within the device) and therefore, are only protected according to the “Human Body Model” requirements. MC45 has been tested and found to comply with the EN 61000-4-2 standard. The measured values can be gathered from the following table. Table 35: Measured electrostatic values Specification / Requirements Contact discharge Air discharge ESD at SIM port ± 4kV ± 8kV ESD at antenna port ± 4kV ± 8kV ETSI EN 301 489-7 Human Body Model (Test conditions: 1.5 kW, 100 pF) ESD at the module Note: ± 1kV Please note that the values may vary with the individual application design. For example, it matters whether or not the application platform is grounded over external devices like a computer or other equipment, such as the Siemens reference application described in Chapter 7. MC45_HD_01_V00.02a Page 87 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 7 Reference Approval 7.1 Reference Equipment The Siemens reference setup that will be submitted to type approve MC45 consists of the following components: · Siemens MC45 cellular engine · Development Support Box (DSB45) · Flex cable (160 mm) from Hirose DF12C receptacle on MC45 to Hirose DF12 connector on DSB45. Please note that this cable is not included in the scope of delivery of DSB45. · SIM card reader integrated on the DSB45 · Handset type Votronic HH-SI-30.3/V1.1/0 · PC as MMI Antenna or 50 W cable to system simulator Antenna PC RS-232 GSM engine DSB45 Flex cable 160mm DAI cable for acoustic measuring SIM DAI Box Power supply Handset Acoustic tester Figure 41: Reference equipment for approval MC45_HD_01_V00.02a Page 88 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY 8 List of parts and accessories Table 36: List of parts and accessories Description Supplier Ordering information MC45 Siemens Siemens ordering number L36880-N8300-A100 Siemens Car Kit Portable Siemens Siemens ordering number: L36880-N3015-A117 DSB45 Support Box Siemens Siemens ordering number: LS36880-N8301-A100 Votronic Handset VOTRONIC Votronic HH-SI-30.3/V1.1 VOTRONIC Entwicklungs- und Produktionsgesellschaft für elektronische Geräte mbH Saarbrücker Str. 8 D-66386 St. Ingbert Phone: 06 89 4 / 92 55-0 Fax: 06 89 4 / 92 55-88 e-mail: contact@votronic.com SIM card holder incl. push button ejector and slide-in tray Molex Ordering numbers: Battery cell XWODA Shenzhen Xwoda Electronic Co., Ltd 91228 91236 Sales contacts are listed in Table 37. To place orders or obtain more information please contact: Shenzhen Xwoda Electronic Co., Ltd Unit 3003, Yingjingyuan,Zhongdian Garden, Shenzhen 518032 P.R.China Contact: Edward Lau or Andy Zhao Phone: +86-755-7623789 ext. 314 Fax: +86-755-7623078 Email: Edward-lau@xwoda.com.cn Email: Andy-zhao@Xwoda.com.cn Info: Http://xwoda.com.cn DF12C board-to-board connector Hirose See Chapter 5.3 for details on receptacle on MC45 and mating headers Sales contacts are listed in Table 38. U.FL-R-SMT antenna connector Hirose See Chapter 5.4 for details on connector, mating plugs and cables U.FL-R-SMT Sales contacts are listed in Table 38. MC45_HD_01_V00.02a Page 89 of 90 12.08.2002 MC45 Hardware Interface Description PRELIMINARY Table 37: Molex sales contacts (subject to change) Molex Molex Deutschland GmbH American Headquarters For further information please click: Felix-Wankel-Str. 11 D-74078 Heilbronn-Biberach Phone: +49(7066)9555 0 Fax: +49(7066)9555 29 Email: mxgermany@molex.com Lisle, Illinois 60532 U.S.A. Phone: 1-800-78MOLEX Fax: 630-969-1352 Molex Singapore Pte. Ltd. Jurong, Singapore Phone: 65-268-6868 Fax: 65-265-6044 Molex Japan Co. Ltd. Yamato, Kanagawa, Japan Phone: 81-462-65-2324 Fax: 81-462-65-2366 http://www.molex.com/ Molex China Distributors Beijing, Room 1319, Tower B, COFCO Plaza No. 8, Jian Guo Men Nei Street, 100005 Beijing People's Republic of China Phone: 86-10-6526-9628 Phone: 86-10-6526-9728 Phone: 86-10-6526-9731 Fax: 86-10-6526-9730 Table 38: Hirose sales contacts (subject to change) Hirose Ltd. For further information please click: http://www.hirose.com Hirose Electric UK, Ltd Crownhill Business Centre 22 Vincent Avenue, Crownhill Milton Keynes, MK8 OAB Phone: 44-1908-305400 Fax: 44-1908-305401 MC45_HD_01_V00.02a Hirose Electric (U.S.A.) Inc 2688 Westhills Court Simi Valley, CA 93065 Phone: 805-522-7958 Fax: 805-522-3217 Hirose Electric GmbH Zeppelinstrasse 42 73760 Ostfildern Kemnat 4 Phone: +49 711 4560-021 Fax +49 711 4560-729 E-mail info@hirose.de Hirose Electric Co., Ltd. 5-23, Osaki 5 Chome, Shinagawa-Ku Tokyo 141, Japan Phone: 03-3491-9741 Fax: 03-3493-2933 Hirose Electric Co., Ltd. Eroupean Brance First class Building 4F Beechavenue 46, 1119PV Schiphol-Rijk, Netherlands Phone: 31-20-6557-460 Fax: 31-20-6557-469 Page 90 of 90 12.08.2002
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2002:08:12 16:24:03+02:00 Subject : Hardware Interface Description Create Date : 2002:08:12 14:19:50Z Page Count : 90 Creation Date : 2002:08:12 14:19:50Z Mod Date : 2002:08:12 16:24:03+02:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : Metadata Date : 2002:08:12 16:24:03+02:00 Creator : Title : MC45 Description : Hardware Interface Description Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools