THALES DIS AlS Deutschland PH8-P GSM/GPRS/UMTS/HSPA Module User Manual hio
Gemalto M2M GmbH GSM/GPRS/UMTS/HSPA Module hio
Contents
- 1. User Manual
- 2. user manual
User Manual
PH8/PH8-P Version: DocId: 02.000 PH8_PH8-P_HD_v02.000 Hardware Interface Overview PH8/PH8-P Hardware Interface Overview Document Name: PH8/PH8-P Hardware Interface Overview Version: 02.000 Date: 2011-10-21 DocId: PH8_PH8-P_HD_v02.000 Status Confidential / Released GENERAL NOTE THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE "PRODUCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS INFORMATION ON CINTERION PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT ARE SUBJECT TO CHANGE AT CINTERION'S DISCRETION. CINTERION WIRELESS MODULES GMBH GRANTS A NON-EXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHALL NOT TRANSFER, COPY, MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE DERIVATIVE WORKS; DISASSEMBLE OR DECOMPILE THE PRODUCT OR OTHERWISE USE THE PRODUCT EXCEPT AS SPECIFICALLY AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN "AS IS" BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, CINTERION WIRELESS MODULES GMBH DISCLAIMS ALL WARRANTIES AND LIABILITIES. THE RECIPIENT UNDERTAKES FOR AN UNLIMITED PERIOD OF TIME TO OBSERVE SECRECY REGARDING ANY INFORMATION AND DATA PROVIDED TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT. THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW. Copyright Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Copyright © 2011, Cinterion Wireless Modules GmbH Trademark Notice Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other registered trademarks or trademarks mentioned in this document are property of their respective owners. PH8_PH8-P_HD_v02.000 Confidential / Released Page 2 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview Contents 46 Contents Introduction ................................................................................................................. 6 1.1 Related Documents ........................................................................................... 6 1.2 Terms and Abbreviations ................................................................................... 6 1.3 Regulatory and Type Approval Information ....................................................... 9 1.3.1 Directives and Standards...................................................................... 9 1.3.2 SAR requirements specific to portable mobiles .................................. 12 1.3.3 SELV Requirements ........................................................................... 13 1.3.4 Safety Precautions.............................................................................. 13 Product Concept ....................................................................................................... 15 2.1 Key Features at a Glance ................................................................................ 15 2.2 PH8/PH8-P System Overview ......................................................................... 18 Application Interface................................................................................................. 19 3.1 Operating Modes ............................................................................................. 20 3.2 Power Supply................................................................................................... 21 3.3 USB Interface................................................................................................... 22 3.4 Serial Interface ASC0 ...................................................................................... 23 3.5 UICC/SIM/USIM Interface................................................................................ 25 3.6 Analog Audio Interface..................................................................................... 27 3.7 Digital Audio Interface...................................................................................... 27 GPS Receiver............................................................................................................. 28 Antenna Interfaces.................................................................................................... 29 5.1 GSM/UMTS Antenna Interface ........................................................................ 29 5.1.1 Antenna Installation ............................................................................ 29 5.1.2 Antenna Connector ............................................................................. 30 5.2 GPS Antenna Interface .................................................................................... 34 Mechanics.................................................................................................................. 35 6.1 Mechanical Dimensions of PH8/PH8-P ........................................................... 35 6.2 Mounting PH8/PH8-P to the Application Platform............................................ 37 6.3 Board-to-Board Application Connector ............................................................ 37 Sample Application................................................................................................... 41 Reference Approval .................................................................................................. 43 8.1 Reference Equipment for Type Approval ......................................................... 43 8.2 Compliance with FCC and IC Rules and Regulations ..................................... 44 Appendix.................................................................................................................... 45 9.1 List of Parts and Accessories........................................................................... 45 PH8_PH8-P_HD_v02.000 Confidential / Released Page 3 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview Tables 46 Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8: Table 9: Table 10: Table 11: Table 12: Table 13: Table 14: Table 15: Table 16: Table 17: Directives ......................................................................................................... 9 Standards of North American type approval .................................................... 9 Standards of European type approval.............................................................. 9 Requirements of quality ................................................................................. 10 Standards of the Ministry of Information Industry of the People’s Republic of China ............................................................................ 10 Toxic or hazardous substances or elements with defined concentration limits ............................................................................................................... 11 Overview of operating modes ........................................................................ 20 DCE-DTE wiring of ASC0 .............................................................................. 24 Signals of the SIM interface (board-to-board connector) ............................... 25 Return loss in the active band........................................................................ 29 Product specifications of PH8/PH8-P antenna connectors ............................ 30 Material and finish of PH8/PH8-P antenna connectors and recommended plugs .............................................................................................................. 31 Ordering information for Hirose U.FL Series.................................................. 33 Technical specifications of Molex board-to-board connector ......................... 38 List of parts and accessories.......................................................................... 45 Molex sales contacts (subject to change) ...................................................... 46 Hirose sales contacts (subject to change) ..................................................... 46 PH8_PH8-P_HD_v02.000 Confidential / Released Page 4 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview Figures 46 Figures Figure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: Figure 12: Figure 13: Figure 14: Figure 15: PH8/PH8-P system overview ......................................................................... USB circuit ..................................................................................................... Serial interface ASC0..................................................................................... UICC/SIM/USIM interface .............................................................................. Mechanical dimensions of PH8/PH8-P antenna connectors.......................... U.FL-R-SMT connector with U.FL-LP-040 plug ............................................. U.FL-R-SMT connector with U.FL-LP-066 plug ............................................. Specifications of U.FL-LP-(V)-040(01) plug ................................................... PH8/PH8-P – top and bottom view ................................................................ Dimensions of PH8/PH8-P (all dimensions in mm)........................................ Mating board-to-board connector 53748-0808 on application ....................... Molex board-to-board connector 52991-0808 on PH8/PH8-P ....................... Mating board-to-board connector 53748-0808 on application ....................... PH8/PH8-P sample application...................................................................... Reference equipment for type approval ......................................................... PH8_PH8-P_HD_v02.000 Confidential / Released Page 5 of 46 18 22 23 26 30 31 31 32 35 36 38 39 40 42 43 2011-10-21 PH8/PH8-P Hardware Interface Overview 1 Introduction 14 Introduction The document1 describes the hardware of the PH8/PH8-P module, designed to connect to a cellular device application and the air interface. It helps you quickly retrieve interface specifications, electrical and mechanical details and information on the requirements to be considered for integrating further components. 1.1 [1] [2] [3] Related Documents PH8/PH8-P AT Command Set PH8/PH8-P Release Notes DSB75 Support Box - Evaluation Kit for Cinterion Wireless Modules 1.2 Terms and Abbreviations Abbreviation Description AGPS Assisted GPS ANSI American National Standards Institute AMR Adaptive Multirate ARP Antenna Reference Point B2B Board-to-board connector BB Baseband BEP Bit Error Probability BTS Base Transceiver Station CB or CBM Cell Broadcast Message CE Conformité Européene (European Conformity) CS Coding Scheme CS Circuit Switched CSD Circuit Switched Data CTM Cellular Text Modem DAC Digital-to-Analog Converter DCS Digital Cellular System DL Download DRX Discontinuous Reception DSB Development Support Board 1. The document is effective only if listed in the appropriate Release Notes as part of the technical documentation delivered with your Cinterion Wireless Modules product. PH8_PH8-P_HD_v02.000 Confidential / Released Page 6 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 1.2 Terms and Abbreviations 14 Abbreviation Description DSP Digital Signal Processor DTMF Dual Tone Multi Frequency DTX Discontinuous Transmission EDGE Enhanced Data rates for GSM Evolution EFR Enhanced Full Rate EGSM Extended GSM EMC Electromagnetic Compatibility ERP Effective Radiated Power ESD Electrostatic Discharge ETS European Telecommunication Standard ETSI European Telecommunications Standards Institute FCC Federal Communications Commission (U.S.) FDD Frequency Division Duplex FDMA Frequency Division Multiple Access FR Full Rate GPRS General Packet Radio Service GPS Global Positioning System GSM Global Standard for Mobile Communications HiZ High Impedance HSDPA High Speed Downlink Packet Access HR Half Rate I/O Input/Output IF Intermediate Frequency IMEI International Mobile Equipment Identity ISO International Standards Organization ITU International Telecommunications Union kbps kbits per second LED Light Emitting Diode Mbps Mbits per second MCS Modulation and Coding Scheme MO Mobile Originated MS Mobile Station, also referred to as TE MT Mobile Terminated NMEA National Marine Electronics Association NTC Negative Temperature Coefficient PBCCH Packet Switched Broadcast Control Channel PH8_PH8-P_HD_v02.000 Confidential / Released Page 7 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 1.2 Terms and Abbreviations 14 Abbreviation Description PCB Printed Circuit Board PCL Power Control Level PCM Pulse Code Modulation PCS Personal Communication System, also referred to as GSM 1900 PDU Protocol Data Unit PS Packet Switched PSK Phase Shift Keying QAM Quadrature Amplitude Modulation R&TTE Radio and Telecommunication Terminal Equipment RF Radio Frequency ROPR Radio Output Power Reduction RTC Real Time Clock Rx Receive Direction SAR Specific Absorption Rate SELV Safety Extra Low Voltage SIM Subscriber Identification Module SLIC Subscriber Line Interface Circuit SMPL Sudden Momentary Power Loss SMS Short Message Service SNR Signal-to-Noise Ratio SRAM Static Random Access Memory SRB Signalling Radio Bearer SUPL Secure User Plane Location TDMA Time Division Multiple Access TE Terminal Equipment TPC Transmit Power Control TS Technical Specification TTFF Time To First Fix Tx Transmit Direction UL Upload UMTS Universal Mobile Telecommunications System URC Unsolicited Result Code USB Universal Serial Bus UICC USIM Integrated Circuit Card USIM UMTS Subscriber Identification Module WCDMA Wideband Code Division Multiple Access PH8_PH8-P_HD_v02.000 Confidential / Released Page 8 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 1.3 Regulatory and Type Approval Information 1.3.1 Directives and Standards PH8/PH8-P has been designed to comply with the directives and standards listed below. It is the responsibility of the application manufacturer to ensure compliance of the final product with all provisions of the applicable directives and standards as well as with the technical specifications provided in the "PH8/PH8-P Hardware Interface Description".1 Table 1: Directives 99/05/EC Directive of the European Parliament and of the council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (in short referred to as R&TTE Directive 1999/5/EC). The product is labeled with the CE conformity mark 2002/95/EC Directive of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) Table 2: Standards of North American type approval CFR Title 47 Code of Federal Regulations, Part 22, Part 24 and Part 27; US Equipment Authorization FCC OET Bulletin 65 (Edition 97-01) Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields UL 60 950-1 Product Safety Certification (Safety requirements) NAPRD.03 V5.8 Overview of PCS Type certification review board Mobile Equipment Type Certification and IMEI control PCS Type Certification Review board (PTCRB) RSS132, RSS133, RSS139 Canadian Standard Table 3: Standards of European type approval 3GPP TS 51.010-1 Digital cellular telecommunications system (Release 7); Mobile Station (MS) conformance specification; ETSI EN 301 511 V9.0.2 Global System for Mobile communications (GSM); Harmonized standard for mobile stations in the GSM 900 and DCS 1800 bands covering essential requirements under article 3.2 of the R&TTE directive (1999/5/EC) GCF-CC V3.43.1 Global Certification Forum - Certification Criteria ETSI EN 301 489-01 V1.8.1 Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common Technical Requirements 1. Manufacturers of applications which can be used in the US shall ensure that their applications have a PTCRB approval. For this purpose they can refer to the PTCRB approval of the respective module. PH8_PH8-P_HD_v02.000 Confidential / Released Page 9 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 Table 3: Standards of European type approval ETSI EN 301 489-03 V1.4.1 Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz ETSI EN 301 489-07 V1.3.1 Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS) ETSI EN 301 489-24 V1.4.1 Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for Mobile and portable (UE) radio and ancillary equipment EN 301 908-01 V3.2.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Base Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cellular networks; Part 1: Harmonized EN for IMT-2000, introduction and common requirements of article 3.2 of the R&TTE Directive EN 301 908-02 V3.2.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Base Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cellular networks; Part 2: Harmonized EN for IMT-2000, CDMA Direct Spread (UTRA FDD) (UE) covering essential requirements of article 3.2 of the R&TTE Directive EN 300 440-02 V1.3.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive EN 62311:2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) IEC/EN 60950-1:2006 Safety of information technology equipment Table 4: Requirements of quality IEC 60068 Environmental testing DIN EN 60529 IP codes Table 5: Standards of the Ministry of Information Industry of the People’s Republic of China SJ/T 11363-2006 “Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products” (2006-06). SJ/T 11364-2006 “Marking for Control of Pollution Caused by Electronic Information Products” (2006-06). According to the “Chinese Administration on the Control of Pollution caused by Electronic Information Products” (ACPEIP) the EPUP, i.e., Environmental Protection Use Period, of this product is 20 years as per the symbol shown here, unless otherwise marked. The EPUP is valid only as long as the product is operated within the operating limits described in the Cinterion Hardware Interface Description. Please see Table 6 for an overview of toxic or hazardous substances or elements that might be contained in product parts in concentrations above the limits defined by SJ/T 11363-2006. PH8_PH8-P_HD_v02.000 Confidential / Released Page 10 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 Table 6: Toxic or hazardous substances or elements with defined concentration limits PH8_PH8-P_HD_v02.000 Confidential / Released Page 11 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 1.3.2 SAR requirements specific to portable mobiles Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM module must be in accordance with the guidelines for human exposure to radio frequency energy. This requires the Specific Absorption Rate (SAR) of portable PH8/PH8-P based applications to be evaluated and approved for compliance with national and/or international regulations. Since the SAR value varies significantly with the individual product design manufacturers are advised to submit their product for approval if designed for portable use. For European and USmarkets the relevant directives are mentioned below. It is the responsibility of the manufacturer of the final product to verify whether or not further standards, recommendations or directives are in force outside these areas. Products intended for sale on US markets ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to electromagnetic fields (EMFs) from mobile telecommunication equipment (MTE) in the frequency range 30MHz - 6GHz Products intended for sale on European markets EN 50360 Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields (300MHz - 3GHz) IMPORTANT: Manufacturers of portable applications based on PH8/PH8-P modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. PH8_PH8-P_HD_v02.000 Confidential / Released Page 12 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 1.3.3 SELV Requirements The power supply connected to the PH8/PH8-P module shall be in compliance with the SELV requirements defined in EN 60950-1. 1.3.4 Safety Precautions The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating PH8/PH8-P. Manufacturers of the cellular terminal are advised to convey the following safety information to users and operating personnel and to incorporate these guidelines into all manuals supplied with the product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Cinterion Wireless Modules assumes no liability for customer’s failure to comply with these precautions. When in a hospital or other health care facility, observe the restrictions on the use of mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guidelines posted in sensitive areas. Medical equipment may be sensitive to RF energy. The operation of cardiac pacemakers, other implanted medical equipment and hearing aids can be affected by interference from cellular terminals or mobiles placed close to the device. If in doubt about potential danger, contact the physician or the manufacturer of the device to verify that the equipment is properly shielded. Pacemaker patients are advised to keep their hand-held mobile away from the pacemaker, while it is on. Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it cannot be switched on inadvertently. The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems. Failure to observe these instructions may lead to the suspension or denial of cellular services to the offender, legal action, or both. Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots, chemical plants or where blasting operations are in progress. Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety hazard. Your cellular terminal or mobile receives and transmits radio frequency energy while switched on. Remember that interference can occur if it is used close to TV sets, radios, computers or inadequately shielded equipment. Follow any special regulations and always switch off the cellular terminal or mobile wherever forbidden, or when you suspect that it may cause interference or danger. Road safety comes first! Do not use a hand-held cellular terminal or mobile when driving a vehicle, unless it is securely mounted in a holder for speakerphone operation. Before making a call with a hand-held terminal or mobile, park the vehicle. Speakerphones must be installed by qualified personnel. Faulty installation or operation can constitute a safety hazard. PH8_PH8-P_HD_v02.000 Confidential / Released Page 13 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 1.3 Regulatory and Type Approval Information 14 IMPORTANT! Cellular terminals or mobiles operate using radio signals and cellular networks. Because of this, connection cannot be guaranteed at all times under all conditions. Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls. Remember, in order to make or receive calls, the cellular terminal or mobile must be switched on and in a service area with adequate cellular signal strength. Some networks do not allow for emergency calls if certain network services or phone features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate those features before you can make an emergency call. Some networks require that a valid SIM card be properly inserted in the cellular terminal or mobile. Bear in mind that exposure to excessive levels of noise can cause physical damage to users! With regard to acoustic shock, the cellular application must be designed to avoid unintentional increase of amplification, e.g. for a highly sensitive earpiece. A protection circuit should be implemented in the cellular application. PH8_PH8-P_HD_v02.000 Confidential / Released Page 14 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 2 Product Concept 18 Product Concept 2.1 Key Features at a Glance Feature Implementation General Frequency bands GSM/GPRS/EDGE: Quad band, 850/900/1800/1900MHz UMTS/HSPA+: PH8: Five band, 800/850/AWS1/1900/2100MHz PH8-P: Five band, 800/850/9002/1900/2100MHz GSM class Small MS Output power (according to Class 4 (+33dBm ±2dB) for EGSM850 Release 99) Class 4 (+33dBm ±2dB) for EGSM900 Class 1 (+30dBm ±2dB) for GSM1800 Class 1 (+30dBm ±2dB) for GSM1900 Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK Class 3 (+24dBm +1/-3dB) for UMTS 2100, WCDMA FDD BdI Class 3 (+24dBm +1/-3dB) for UMTS 1900,WCDMA FDD BdII Class 3 (+24dBm +1/-3dB) for UMTS AWS, WCDMA FDD BdIV1 Class 3 (+24dBm +1/-3dB) for UMTS 900, WCDMA FDD BdVIII2 Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV Class 3 (+24dBm +1/-3dB) for UMTS 800, WCDMA FDD BdVI Power supply 3.3V < VBATT+ < 4.2V Operating temperature (board temperature) Normal operation: -30°C to +85°C Restricted operation: -40°C to +95°C Physical Dimensions: 33.9mm x 50mm x 3.1mm Weight: approx. 9.5g RoHS All hardware components fully compliant with EU RoHS Directive HSPA features 3GPP Release 6, 7 DL 14.4Mbps, UL 5.7Mbps UE CAT. 1-12 supported Compressed mode (CM) supported according to 3GPP TS25.212 UMTS features 3GPP Release 4 PH8_PH8-P_HD_v02.000 Confidential / Released PS data rate – 384 kbps DL / 384 kbps UL CS data rate – 64 kbps DL / 64 kbps UL Page 15 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 2.1 Key Features at a Glance 18 Feature Implementation GSM / GPRS / EGPRS features Data transfer GPRS: • Multislot Class 12 • Full PBCCH support • Mobile Station Class B • Coding Scheme 1 – 4 EGPRS: • Multislot Class 12 • EDGE E2 power class for 8 PSK • Downlink coding schemes – CS 1-4, MCS 1-9 • Uplink coding schemes – CS 1-4, MCS 1-9 • SRB loopback and test mode B • 8-bit, 11-bit RACH • PBCCH support • 1 phase/2 phase access procedures • Link adaptation and IR • NACC, extended UL TBF • Mobile Station Class B CSD: • V.110, RLP, non-transparent • 14.4kbps • USSD SMS Point-to-point MT and MO Cell broadcast Text and PDU mode GPS Features Protocol NMEA Modes Standalone GPS Assisted GPS - Control plane - E911 - User plane - gpsOneXTRA™ General Power saving modes Power supply for active GPS antenna supported Software AT commands Hayes, 3GPP TS 27.007 and 27.005, and proprietary Cinterion Wireless Modules commands SIM Application Toolkit SAT Release 99 Audio Audio speech codecs GSM: AMR, EFR, FR, HR 3GPP: AMR Speakerphone operation, echo cancellation, noise suppression, 9 ringing tones, TTY support Firmware update Generic update from host application over ASC0 or USB Interfaces Module interface 80-pin board-to-board connector Antenna 50Ohms. Main GSM/UMTS antenna, UMTS diversity antenna, GPS antenna (active/passive) PH8_PH8-P_HD_v02.000 Confidential / Released Page 16 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 2.1 Key Features at a Glance 18 Feature Implementation USB USB 2.0 High Speed (480Mbit/s) device interface, Full Speed (12Mbit/s) compliant Serial interface ASC0: • 8-wire modem interface with status and control lines, unbalanced, asynchronous • Adjustable baud rates from 9,600bps up to 921,600bps • Supports RTS0/CTS0 hardware flow control • Multiplex ability according to GSM 07.10 Multiplexer Protocol UICC interface Supported chip cards: UICC/SIM/USIM 3V, 1.8V Status Signal line to indicate network connectivity state Audio 1 analog interface with microphone feeding 1 digital interface: PCM or I2S Power on/off, Reset Power on/off Switch-on by hardware signal IGT Switch-off by AT command (AT^SMSO) Automatic switch-off in case of critical temperature or voltage conditions Reset Orderly shutdown and reset by AT command Emergency-off Emergency-off by hardware signal EMERG_OFF if IGT is not active Special Features Phonebook SIM and phone TTY/CTM support Integrated CTM modem Antenna SAIC (Single Antenna Interference Cancellation) / DARP (Downlink Advanced Receiver Performance) Rx diversity (receiver type 3i - 16-QAM)3 Evaluation kit DSB75 1. 2. 3. DSB75 Evaluation Board designed to test and type approve Cinterion Wireless Modules and provide a sample configuration for application engineering. A special adapter is required to connect the module to the DSB75. AWS UMTS/HSPA+ band IV supported by PH8 only. 900MHz UMTS/HSPA+ band VIII supported by PH8-P only. Band VIII however, is not supported by the UMTS Rx diversity antenna. UMTS Rx diversity antenna does not support UMTS/HSPA+ band VIII. PH8_PH8-P_HD_v02.000 Confidential / Released Page 17 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 2.2 PH8/PH8-P System Overview 18 2.2 PH8/PH8-P System Overview GPS antenna GSM/UMTS antenna UMTS diversity antenna GSM/UMTS GPS Module UICC Analog audio SIM card Host application Power supply Digital audio PCM or I2S codec Power for application (VEXT) Power indication (PWR_IND) Serial ASC0 Modem interface USB RTC IGT, Emergency Off Net state/ status or On/Off Application Figure 1: PH8/PH8-P system overview PH8_PH8-P_HD_v02.000 Confidential / Released Page 18 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 3 Application Interface 28 Application Interface PH8/PH8-P is equipped with an 80-pin board-to-board connector that connects to the external application. The host interface incorporates several sub-interfaces described in the following sections: • • • • • • • Operating modes - see Section 3.1 Power supply - see Section 3.2 Serial interface USB - see Section 3.3 Serial interface ASC0 - Section 3.4 UICC/SIM/USIM interface - see Section 3.5 Analog audio interface - see Section 3.6 Digital audio interface (PCM or I2S) - see Section 3.7 PH8_PH8-P_HD_v02.000 Confidential / Released Page 19 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 3.1 Operating Modes 28 3.1 Operating Modes The table below briefly summarizes the various operating modes referred to in the following chapters. Table 7: Overview of operating modes Mode Function Normal GSM / operation GPRS / UMTS / HSPA SLEEP Power saving set automatically when no call is in progress and the USB connection is suspended by host or not present and no active communication via ASC0. GSM / GPRS / UMTS / HSPA IDLE Power saving disabled (see [1]: AT^SCFG "MEopMode/ PwrSave",) or an USB connection not suspended, but no call in progress. GSM TALK/ GSM DATA Connection between two subscribers is in progress. Power consumption depends on the GSM network coverage and several connection settings (e.g. DTX off/on, FR/EFR/HR, hopping sequences and antenna connection). The following applies when power is to be measured in TALK_GSM mode: DTX off, FR and no frequency hopping. GPRS DATA GPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and GPRS configuration (e.g. used multislot settings). EGPRS DATA EGPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and EGPRS configuration (e.g. used multislot settings). UMTS TALK/ UMTS DATA UMTS data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate. HSPA DATA HSPA data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate. Power Down Normal shutdown after sending the AT^SMSO command. Only a voltage regulator is active for powering the RTC. Software is not active. Interfaces are not accessible. Operating voltage (connected to BATT+) remains applied. Airplane mode Airplane mode shuts down the radio part of the module, causes the module to log off from the GSM/GPRS network and disables all AT commands whose execution requires a radio connection. Airplane mode can be controlled by AT command (see [1]). PH8_PH8-P_HD_v02.000 Confidential / Released Page 20 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 3.2 Power Supply 28 3.2 Power Supply PH8/PH8-P needs to be connected to a power supply at the board-to-board connector - 5 lines each BATT+ and GND. The power supply of PH8/PH8-P has to be a single voltage source at BATT+. It must be able to provide the peak current during the uplink transmission. All key functions for supplying power to the device are handled by the power management IC. It provides the following features: • Stabilizes the supply voltages for the baseband using switching regulators and low drop linear voltage regulators. • Switches the module's power voltages for the power-up and -down procedures. • Delivers, across the VEXT line, a regulated voltage for an external application. This voltage is not available in Power-down mode and can be reduced via AT command to save power. • SIM switch to provide SIM power supply. PH8_PH8-P_HD_v02.000 Confidential / Released Page 21 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 3.3 USB Interface 28 3.3 USB Interface PH8/PH8-P supports a USB 2.0 High Speed (480Mbit/s) device interface that is Full Speed (12Mbit/s) compliant. The USB interface is primarily intended for use as command and data interface and for downloading firmware. The USB host is responsible for supplying the VUSB_IN line. This line is for voltage detection only. The USB part (driver and transceiver) is supplied by means of BATT+. This is because PH8/PH8-P is designed as a self-powered device compliant with the “Universal Serial Bus Specification Revision 2.0”1. Module B2B VREG (3V075) lin. reg. BATT+ GND USB part1) VBUS Detection only VUSB_IN USB_DP2) USB_DN2) DP DN Host wakeup RING0 WAKEUP 1) All serial and pull-up resistors for data lines are implemented. If the USB interface is operated in High Speed mode (480MHz), it is recommended to take special care routing the data lines USB_DP and USB_DN. Application layout should in this case implement a differential impedance of 90Ohm for proper signal integrity. 2) Figure 2: USB circuit To properly connect the module's USB interface to the host a USB 2.0 compatible connector is required. Furthermore, the USB modem driver distributed with PH8/PH8-P needs to be installed. While the USB connection is active, the module will not change into SLEEP Mode. To enable switching into SLEEP mode the USB host must bring its USB interface into Suspend state (see “Universal Serial Bus Specification Revision 2.0“1 for a description of the Suspend state). On incoming calls PH8/PH8-P will then generate a remote wake up request to resume the USB connection (active low). If configured for SDPORT=6, i.e., if using a CDC ACM compatible USB driver on the host system, a selective suspend on the USB host may not be supported and the module may therefore not be able to change into SLEEP mode. As an alternative to the regular USB remote wakeup mechanism it is possible to employ the RING0 or WAKEUP line to wake up the host application. The benefit is that the RING0 or WAKEUP lines can wake up the host application in case of incoming calls or other events signalized by URCs while the USB interface is suspended or shut down. 1. The specification is ready for download on http://www.usb.org/developers/docs/ PH8_PH8-P_HD_v02.000 Confidential / Released Page 22 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 3.4 Serial Interface ASC0 28 3.4 Serial Interface ASC0 PH8/PH8-P offers an 8-wire unbalanced, asynchronous modem interface ASC0 conforming to ITU-T V.24 protocol DCE signalling. The electrical characteristics do not comply with ITU-T V.28. The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit or inactive state). PH8/PH8-P is designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals: • Port TXD @ application sends data to the module’s TXD0 signal line • Port RXD @ application receives data from the module’s RXD0 signal line Figure 3: Serial interface ASC0 Features: • Includes the data lines TXD0 and RXD0, the status lines RTS0 and CTS0 and, in addition, the modem control lines DTR0, DSR0, DCD0 and RING0. • ASC0 is designed for controlling GSM/UMTS voice calls, transferring data and for controlling the module with AT commands. • Full multiplexing capability allows the interface to be partitioned into virtual channels. • The RING0 signal serves to indicate incoming calls and other types of URCs (Unsolicited Result Code). It can also be used to send pulses to the host application, for example to wake up the application from power saving state. See [1] for details on how to configure the RING0 line by AT^SCFG. • Configured for 8 data bits, no parity and 1 stop bit. • ASC0 can be operated at fixed bit rates from 9600bps up to 921600bps. • Supports RTS0/CTS0 hardware flow control. • Wake up from SLEEP mode by RTS0 activation (high to low transition). Note. If the ASC0 serial interface is the application’s only interface, it is suggested to connect test points on the USB signal lines as a potential tracing possibility. PH8_PH8-P_HD_v02.000 Confidential / Released Page 23 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 3.4 Serial Interface ASC0 28 Table 8: DCE-DTE wiring of ASC0 V.24 circuit DCE DTE Line function Signal direction Line function Signal direction 103 TXD0 Input TXD Output 104 RXD0 Output RXD Input 105 RTS0 Input RTS Output 106 CTS0 Output CTS Input 108/2 DTR0 Input DTR Output 107 DSR0 Output DSR Input 109 DCD0 Output DCD Input 125 RING0 Output RING Input PH8_PH8-P_HD_v02.000 Confidential / Released Page 24 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 3.5 UICC/SIM/USIM Interface 28 3.5 UICC/SIM/USIM Interface PH8/PH8-P has an integrated UICC/SIM/USIM interface compatible with the 3GPP 31.102 and ETSI 102 221. This is wired to the host interface in order to be connected to an external SIM card holder. Six pins on the board-to-board connector are reserved for the SIM interface. The UICC/SIM/USIM interface supports 3V and 1.8V SIM cards. The CCIN signal serves to detect whether a tray (with SIM card) is present in the card holder. Using the CCIN signal is mandatory for compliance with the GSM 11.11 recommendation if the mechanical design of the host application allows the user to remove the SIM card during operation. To take advantage of this feature, an appropriate SIM card detect switch is required on the card holder. For example, this is true for the model supplied by Molex, which has been tested to operate with PH8/PH8-P and is part of the Cinterion reference equipment submitted for type approval. See Chapter 9 for Molex ordering numbers. Table 9: Signals of the SIM interface (board-to-board connector) Signal Description CCGND Separate ground connection for SIM card to improve EMC. Be sure to use this ground line for the SIM interface rather than any other ground line or plane on the module. CCCLK Chipcard clock CCVCC SIM supply voltage. CCIO Serial data line, input and output. CCRST Chipcard reset CCIN Input on the baseband processor for detecting a SIM card tray in the holder. If the SIM is removed during operation the SIM interface is shut down immediately to prevent destruction of the SIM. The CCIN signal is active low. The CCIN signal is mandatory for applications that allow the user to remove the SIM card during operation. The CCIN signal is solely intended for use with a SIM card. It must not be used for any other purposes. Failure to comply with this requirement may invalidate the type approval of PH8/ PH8-P. Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after removing the SIM card during operation. Also, no guarantee can be given for properly initializing any SIM card that the user inserts after having removed the SIM card during operation. In this case, the application must restart PH8/PH8-P. PH8_PH8-P_HD_v02.000 Confidential / Released Page 25 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 3.5 UICC/SIM/USIM Interface 28 open: Card removed closed: Card inserted Module Board-to-board connector CCIN CCRST 1n CCCLK SIM / UICC CCGND CCIO CCVCC 220n Figure 4: UICC/SIM/USIM interface The total cable length between the board-to-board connector pins on PH8/PH8-P and the pads of the external SIM card holder must not exceed 100mm in order to meet the specifications of 3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance. To avoid possible cross-talk from the CCCLK signal to the CCIO signal be careful that both lines are not placed closely next to each other. A useful approach is using the CCGND line to shield the CCIO line from the CCCLK line. PH8_PH8-P_HD_v02.000 Confidential / Released Page 26 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 3.6 Analog Audio Interface 28 3.6 Analog Audio Interface PH8/PH8-P has an analog audio interface with a balanced analog microphone input and a balanced analog earpiece output. A supply voltage and an analog ground connection are provided at dedicated lines. PH8/PH8-P offers eight audio modes which can be selected with the AT^SNFS command. The electrical characteristics of the voiceband part vary with the audio mode. For example, sending and receiving amplification, sidetone paths, noise suppression etc. depend on the selected mode and can in parts be altered with AT commands (except for mode 1). When shipped from factory, all audio parameters of PH8/PH8-P are set to audio mode 1. This is the default configuration optimised for the Votronic HH-SI-30.3/V1.1/0 handset and used for type approving the Cinterion Wireless Modules reference configuration. Audio mode 1 has fix parameters which cannot be modified. To adjust the settings of the Votronic handset simply change to another audio mode. 3.7 Digital Audio Interface PH8/PH8-P supports a digital audio interface that can be employed either as pulse code modulation or as inter IC sound interface. Operation of these interface variants is mutually exclusive. PH8_PH8-P_HD_v02.000 Confidential / Released Page 27 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 4 GPS Receiver 28 GPS Receiver PH8/PH8-P integrates a GPS receiver that offers the full performance of GPS technology. The GPS receiver is able to continuously track all satellites in view, thus providing accurate satellite position data. The integrated GPS receiver supports the NMEA protocol via USB or ASC0 interface. NMEA is a combined electrical and data specification for communication between various (marine) electronic devices including GPS receivers. It has been defined and controlled by the USbased National Marine Electronics Association. For more information on the NMEA Standard please refer to http://www.nmea.org. Depending on the receiver’s knowledge of last position, current time and ephemeris data, the receiver’s startup time (i.e., TTFF = Time-To-First-Fix) may vary: If the receiver has no knowledge of its last position or time, a startup takes considerably longer than if the receiver has still knowledge of its last position, time and almanac or has still access to valid ephimeris data and the precise time. By default, the GPS receiver is switched off. It has to be switched on and configured using AT commands. For more information on how to control the GPS interface via the AT command AT^SGPSC see [1]. PH8_PH8-P_HD_v02.000 Confidential / Released Page 28 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 5 Antenna Interfaces 34 Antenna Interfaces 5.1 GSM/UMTS Antenna Interface The PH8/PH8-P GSM/UMTS antenna interface comprises a main GSM/UMTS antenna as well as an optional UMTS Rx diversity antenna to improve signal reliability and quality1. The interface has an impedance of 50Ω. PH8/PH8-P is capable of sustaining a total mismatch at the antenna interface without any damage, even when transmitting at maximum RF power. The external antenna must be matched properly to achieve best performance regarding radiated power, DC-power consumption, modulation accuracy and harmonic suppression. Matching networks are not included on the PH8/PH8-P PCB and should be placed in the host application, if the antenna does not have an impendance of 50Ω. Regarding the return loss PH8/PH8-P provides the following values in the active band: Table 10: Return loss in the active band State of module Return loss of module Recommended return loss of application Receive > 8dB > 12dB Transmit not applicable > 12dB Idle < 5dB not applicable The connection of the antenna or other equipment must be decoupled from DC voltage. This is necessary because the antenna connector is DC coupled to ground via an inductor for ESD protection. 5.1.1 Antenna Installation The U.FL antenna connector from Hirose/Molex of the main GSM/UMTS antenna has been chosen as antenna reference point (ARP) for the Cinterion Wireless Modules reference equipment submitted to type approve PH8/PH8-P. See Section 5.1.2 for details. All RF data specified throughout this manual is related to the ARP. The positions of the module’s antenna connectors can be seen in Figure 9. 1. By delivery default the optional UMTS Rx diversity antenna is configured as available for the module. To avoid negative side effects and performance degradation it is recommended to disable the diversity antenna path if - the host application does not support a diversity antenna - the host application includes a diversity antenna - but a 3G network simulator is used for development and performance tests. Please refer to [1] for details on how to configure antenna settings. PH8_PH8-P_HD_v02.000 Confidential / Released Page 29 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 5.1 GSM/UMTS Antenna Interface 34 5.1.2 Antenna Connector PH8/PH8-P uses either an ultra-miniature SMT antenna connector from Hirose Ltd: U.FL-RSMT, or the Molex 07341201 U.FL antenna connector. Both connectors have identical mechanical dimensions (see Figure 5). Minor differences in product specifications are mentioned in Table 11. The position of the antenna connectors on the PH8/PH8-P board can be seen in Figure 9. Figure 5: Mechanical dimensions of PH8/PH8-P antenna connectors Table 11: Product specifications of PH8/PH8-P antenna connectors Item Specification Conditions Nominal impedance 50 Rated frequency DC to 3GHz Operating temp:-40°C to + 90°C Operating humidity: max. 90% Ratings Mechanical characteristics Repetitive operation Contact resistance: Center 25m Outside 15m 30 cycles of insertion and disengagement Vibration No momentary disconnections of 1µs. Frequency of 10 to 100Hz, single No damage, cracks and looseness of amplitude of 1.5mm, acceleration parts. of 59m/s2, for 5 cycles in the direction of each of the 3 axes Shock No momentary disconnections of 1µs. Acceleration of 735m/s2, 11ms No damage, cracks and looseness of duration for 6 cycles in the direction of each of the 3 axes parts. Environmental characteristics Humidity resistance No damage, cracks and looseness of parts. Insulation resistance: 100M min. at high humidity 500M min. when dry Exposure to 40°C, humidity of 95% for a total of 96 hours Temperature cycle No damage, cracks and looseness of parts. Contact resistance: Center 25m Outside 15m Temperature: +40°C 5 to 35°C +90°C 5 to 35°C Time: 30min within 5min 30min within 5min Salt spray test No excessive corrosion 48 hours continuous exposure to 5% salt water PH8_PH8-P_HD_v02.000 Confidential / Released Page 30 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 5.1 GSM/UMTS Antenna Interface 34 Table 12: Material and finish of PH8/PH8-P antenna connectors and recommended plugs Part Material Finish Shell Phosphor bronze Hirose: Silver plating Molex: Gold plating Male center contact Brass Gold plating Female center contact Phosphor bronze Gold plating Insulator Receptacle: LCP Hirose: Beige, Molex: Ivory Mating plugs and cables can be chosen from the Hirose U.FL Series or from other antenna equipment manufacturers like Molex or IMS. Examples from the Hirose U.FL Series are shown below and listed in Table 13. For latest product information please contact your respective antenna equipment manufacturer. Figure 6: U.FL-R-SMT connector with U.FL-LP-040 plug Figure 7: U.FL-R-SMT connector with U.FL-LP-066 plug PH8_PH8-P_HD_v02.000 Confidential / Released Page 31 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 5.1 GSM/UMTS Antenna Interface 34 In addition to the connectors illustrated above, the U.FL-LP-(V)-040(01) version is offered as an extremely space saving solution. This plug is intended for use with extra fine cable (up to Ø 0.81mm) and minimizes the mating height to 2mm. See Figure 8 which shows the Hirose data sheet. Figure 8: Specifications of U.FL-LP-(V)-040(01) plug PH8_PH8-P_HD_v02.000 Confidential / Released Page 32 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 5.1 GSM/UMTS Antenna Interface 34 Table 13: Ordering information for Hirose U.FL Series Item Part number HRS number Connector on PH8/PH8-P U.FL-R-SMT CL331-0471-0-10 Right-angle plug shell for Ø 0.81mm cable U.FL-LP-040 CL331-0451-2 Right-angle plug for Ø 0.81mm cable U.FL-LP(V)-040 (01) CL331-053-8-01 Right-angle plug for Ø 1.13mm cable U.FL-LP-068 CL331-0452-5 Right-angle plug for Ø 1.32mm cable U.FL-LP-066 CL331-0452-5 Extraction jig E.FL-LP-N CL331-04441-9 PH8_PH8-P_HD_v02.000 Confidential / Released Page 33 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 5.2 GPS Antenna Interface 34 5.2 GPS Antenna Interface In addition to the RF antenna interface PH8/PH8-P also has a GPS antenna interface. See Section 6.1 to find out where the GPS antenna connector is located. The GPS antenna installation and connector are the same as for the RF antenna interface (see Section 5.1.1 and Section 5.1.2). It is possible to connect active or passive GPS antennas. In either case they must have 50 Ohm impedance. The simultaneous operation of GSM and GPS has been implemented. Active 3V GPS antennas can be supplied via the GPS antenna interface, if the supply voltage is switched on. This is done by AT command: AT^SGPSC="Power/Antenna" to configure the use of an active GPS antenna and AT^SGPSC="Engine" to start the GPS receiver (for command details see [1]). The available current is limited to prevent short circuits. PH8_PH8-P_HD_v02.000 Confidential / Released Page 34 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 6 Mechanics 40 Mechanics 6.1 Mechanical Dimensions of PH8/PH8-P Figure 9 shows the top view of PH8/PH8-P and provides an overview of the board's mechanical dimensions. For further details see Figure 10. Length: 50.00mm Width: 33.90mm Height: 3.10mm Pin 80 Pin 1 Application interface (board-to-board connector) GSM/UMTS antenna Pin 41 Pin 40 UMTS diversity antenna Top view GPS antenna Bottom view Figure 9: PH8/PH8-P – top and bottom view PH8_PH8-P_HD_v02.000 Confidential / Released Page 35 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 6.1 Mechanical Dimensions of PH8/PH8-P 40 Figure 10: Dimensions of PH8/PH8-P (all dimensions in mm) PH8_PH8-P_HD_v02.000 Confidential / Released Page 36 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 6.2 Mounting PH8/PH8-P to the Application Platform 40 6.2 Mounting PH8/PH8-P to the Application Platform There are many ways to properly install PH8/PH8-P in the host device. An efficient approach is to mount the PH8/PH8-P PCB to a frame, plate, rack or chassis. Fasteners can be M2 screws plus suitable washers, circuit board spacers, or customized screws, clamps, or brackets. In addition, the board-to-board connection can also be utilized to achieve better support. For proper grounding it is strongly recommended to use large ground plane on the bottom of board in addition to the five GND pins of the board-to-board connector. The ground plane may also be used to attach cooling elements, e.g. a heat sink or thermally conductive tape. To prevent mechanical damage, be careful not to force, bend or twist the module. Be sure it is positioned flat against the host device. 6.3 Board-to-Board Application Connector This section provides the specifications of the 80-pin board-to-board connector used to connect PH8/PH8-P to the external application. Connector mounted on the PH8/PH8-P module: Type: Supplier: 52991-0808 SlimStack Receptacle 80 pins, 0.50mm pitch, for stacking heights of 3.0 or 4.0mm, see Figure 12 for details. Molex, http//www.molex.com PH8_PH8-P_HD_v02.000 Confidential / Released Page 37 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 6.3 Board-to-Board Application Connector 40 Table 14: Technical specifications of Molex board-to-board connector Parameter Specification (80-pin B2B connector) Electrical Number of Contacts 80 Contact spacing 0.5mm (.020") Voltage 50V Rated current 0.5A max per contact Contact resistance 50m max per contact Insulation resistance > 100M Dielectric Withstanding Voltage 500V AC (for 1 minute) Physical Insulator material (housing) White glass-filled LCP plastic, flammability UL 94V 0 Contact material Plating: Gold over nickel Insertion force 1st Insertion force 30 < 74.4N th < 65.6N Withdrawal force 1st > 10.8N Maximum connection cycles 30 (@ 70m max per contact) Mating connector types for the customer's application offered by Molex: Figure 11: Mating board-to-board connector 53748-0808 on application • • 53748-0808 SlimStack Plug, 3mm stacking height, see Figure 13 for details. 53916-0808 SlimStack Plug, 4mm stacking height Note: There is no inverse polarity protection for the board-to-board connector. It is therefore very important that the board-to-board connector is connected correctly to the host application, i.e., pin1 must be connected to pin1, pin2 to pin 2, etc. Pin locations are shown in Figure 9. PH8_PH8-P_HD_v02.000 Confidential / Released Page 38 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 6.3 Board-to-Board Application Connector 40 Figure 12: Molex board-to-board connector 52991-0808 on PH8/PH8-P PH8_PH8-P_HD_v02.000 Confidential / Released Page 39 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 6.3 Board-to-Board Application Connector 40 Figure 13: Mating board-to-board connector 53748-0808 on application PH8_PH8-P_HD_v02.000 Confidential / Released Page 40 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 7 Sample Application 42 Sample Application Figure 14 shows a typical example of how to integrate an PH8/PH8-P module with an application. The audio interface demonstrates the balanced connection of microphone and earpiece. This solution is particularly well suited for internal transducers. The PWR_IND line is an open collector that needs an external pull-up resistor which connects to the voltage supply VCC µC of the microcontroller. Low state of the open collector pulls the PWR_IND signal low and indicates that the PH8/PH8-P module is active, high level notifies the Power-down mode. If the module is in Power-down mode avoid current flowing from any other source into the module circuit, for example reverse current from high state external control lines. Therefore, the controlling application must be designed to prevent reverse flow. If an external level controller is required, this can be done by using for example a 5V I/O tolerant buffer/driver like a "74AVC4T245" with OE (Output Enable) controlled by PWR_IND. The EMC measures are best practice recommendations. In fact, an adequate EMC strategy for an individual application is very much determined by the overall layout and, especially, the position of components. Disclaimer: No warranty, either stated or implied, is provided on the sample schematic diagram shown in Figure 14 and the information detailed in this section. As functionality and compliance with national regulations depend to a great amount on the used electronic components and the individual application layout manufacturers are required to ensure adequate design and operating safeguards for their products using PH8/PH8-P modules. PH8_PH8-P_HD_v02.000 Confidential / Released Page 41 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 7 Sample Application 42 Figure 14: PH8/PH8-P sample application PH8_PH8-P_HD_v02.000 Confidential / Released Page 42 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 8 Reference Approval 44 Reference Approval 8.1 Reference Equipment for Type Approval The Cinterion Wireless Modules reference setup submitted to type approve PH8/PH8-P is shown in the following figure1. The module is connected to the DSB75 via a special adapter and either mounted directly onto the adapter or connected using a flex cable: Figure 15: Reference equipment for type approval 1. For RF performance tests a mini-SMT/U.FL to SMA adapter with attached 6dB coaxial attenuator is chosen to connect the module directly to the GSM/UMTS/GPS test equipment instead of employing the SMA antenna connectors on the PH8/PH8-P-DSB75 adapter as shown in Figure 15. The following products are recommended: Hirose SMA-Jack/U.FL-Plug conversion adapter HRMJ-U.FLP(40) (for details see see http://www.hirose-connectors.com/ or http://www.farnell.com/ Aeroflex Weinschel Fixed Coaxial Attenuator Model 3T/4T (for details see http://www.aeroflex.com/ams/weinschel/pdfiles/wmod3&4T.pdf) PH8_PH8-P_HD_v02.000 Confidential / Released Page 43 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 8.2 Compliance with FCC and IC Rules and Regulations 44 8.2 Compliance with FCC and IC Rules and Regulations The Equipment Authorization Certification for the Cinterion Wireless Modules reference application described in Section 8.1 will be registered under the following identifiers: • PH8: FCC Identifier QIPPH8 Industry Canada Certification Number: 7830A-PH8 Granted to Cinterion Wireless Modules GmbH • PH8-P: FCC Identifier QIPPH8-P Industry Canada Certification Number: 7830A-PH8P Granted to Cinterion Wireless Modules GmbH Manufacturers of mobile or fixed devices incorporating PH8/PH8-P modules are authorized to use the FCC Grants and Industry Canada Certificates of the PH8/PH8-P modules for their own final products according to the conditions referenced in these documents. In this case, the FCC label of the module shall be visible from the outside, or the host device shall bear a second label stating "Contains FCC ID QIPPH8" resp. "Contains FCC ID QIPPH8-P", and accordingly “Contains IC 7830A-PH8“ resp. “Contains IC 7830A-PH8P“. The integration is limited to fixed or mobile categorised host devices, where a separation distance between the antenna and any person of min. 20cm can be assured during normal operating conditions. For mobile and fixed operation configurations the antenna gain, including cable loss, must not exceed the limits that are stated on the FCC Grant. IMPORTANT: Manufacturers of portable applications incorporating PH8/PH8-P modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. This is mandatory to meet the SAR requirements for portable mobiles. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. PH8_PH8-P_HD_v02.000 Confidential / Released Page 44 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 9 Appendix 46 Appendix 9.1 List of Parts and Accessories Table 15: List of parts and accessories Description Supplier Ordering information PH8 Cinterion Standard module Cinterion Wireless Modules IMEI: Ordering number: L30960-N1900-A200 Customer IMEI: Ordering number: L30960-N1905-A200 PH8-P Cinterion Standard module Cinterion Wireless Modules IMEI: Ordering number: L30960-N1910-A200 Customer IMEI: Ordering number: L30960-N1915-A200 DSB75 Support Box Cinterion Ordering number: L36880-N8811-A100 DSB75 adapter for mounting the PH8/PH8-P evaluation module Cinterion Ordering number: L30960-N1802-A100 Votronic Handset VOTRONIC Votronic HH-SI-30.3/V1.1/0 VOTRONIC Entwicklungs- und Produktionsgesellschaft für elektronische Geräte mbH Saarbrücker Str. 8 66386 St. Ingbert Germany Phone: +49-(0)6 89 4 / 92 55-0 Fax: +49-(0)6 89 4 / 92 55-88 Email: contact@votronic.com SIM card holder incl. push button ejector and slide-in tray Molex Ordering numbers: 91228 91236 Sales contacts are listed in Table 16. Board-to-board connector Molex Sales contacts are listed in Table 16. U.FL antenna connector Hirose or Molex Sales contacts are listed in Table 16 and Table 17. PH8_PH8-P_HD_v02.000 Confidential / Released Page 45 of 46 2011-10-21 PH8/PH8-P Hardware Interface Overview 9.1 List of Parts and Accessories 46 Table 16: Molex sales contacts (subject to change) Molex For further information please click: http://www.molex.com Molex Deutschland GmbH Felix-Wankel-Str. 11 4078 Heilbronn-Biberach Germany Phone: +49-7066-9555 0 Fax: +49-7066-9555 29 Email: mxgermany@molex.com American Headquarters Lisle, Illinois 60532 U.S.A. Phone: +1-800-78MOLEX Fax: +1-630-969-1352 Molex China Distributors Beijing, Room 1319, Tower B, COFCO Plaza No. 8, Jian Guo Men Nei Street, 100005 Beijing P.R. China Phone: +86-10-6526-9628 Phone: +86-10-6526-9728 Phone: +86-10-6526-9731 Fax: +86-10-6526-9730 Molex Singapore Pte. Ltd. Jurong, Singapore Phone: +65-268-6868 Fax: +65-265-6044 Molex Japan Co. Ltd. Yamato, Kanagawa, Japan Phone: +81-462-65-2324 Fax: +81-462-65-2366 Table 17: Hirose sales contacts (subject to change) Hirose Electric (U.S.A.) Inc 2688 Westhills Court Simi Valley, CA 93065 U.S.A. Hirose Electric GmbH Herzog-Carl-Strasse 4 73760 Ostfildern Germany Phone: +1-805-522-7958 Fax: +1-805-522-3217 Phone: +49-711-456002-1 Fax: +49-711-456002-299 Email: info@hirose.de Hirose Electric UK, Ltd Crownhill Business Centre 22 Vincent Avenue, Crownhill Milton Keynes, MK8 OAB Great Britain Hirose Electric Co., Ltd. 5-23, Osaki 5 Chome, Shinagawa-Ku Tokyo 141 Japan Phone: +44-1908-305400 Fax: +44-1908-305401 Phone: +81-03-3491-9741 Fax: +81-03-3493-2933 Hirose Electric Co., Ltd. European Branche First class Building 4F Beechavenue 46 1119PV Schiphol-Rijk Netherlands Hirose Ltd. For further information please click: http://www.hirose.com PH8_PH8-P_HD_v02.000 Confidential / Released Page 46 of 46 Phone: +31-20-6557-460 Fax: +31-20-6557-469 2011-10-21
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : ctna0151 Create Date : 2011:10:21 09:43:04Z Modify Date : 2011:10:21 10:12:42+02:00 XMP Toolkit : Adobe XMP Core 4.2.2-c063 53.352624, 2008/07/30-18:12:18 Creator Tool : FrameMaker 9.0 Metadata Date : 2011:10:21 10:12:42+02:00 Format : application/pdf Title : hio.book Creator : ctna0151 Producer : Acrobat Distiller 9.4.6 (Windows) Document ID : uuid:4ddad4cd-2c42-4ddc-a363-65136ae6d801 Instance ID : uuid:55a958ed-4abd-40c6-bfc5-81a7f60bbd8e Page Mode : UseOutlines Page Count : 46EXIF Metadata provided by EXIF.tools