THALES DIS AlS Deutschland PLS8-USR4 GSM, WCDMA, LTE Module User Manual hid pls8 us

Gemalto M2M GmbH GSM, WCDMA, LTE Module hid pls8 us

User Manual

Download: THALES DIS AlS Deutschland PLS8-USR4 GSM, WCDMA, LTE Module User Manual hid pls8 us
Mirror Download [FCC.gov]THALES DIS AlS Deutschland PLS8-USR4 GSM, WCDMA, LTE Module User Manual hid pls8 us
Document ID3344487
Application ID0CHTcO/RrsHDFO1kLOIEMA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize64.56kB (806986 bits)
Date Submitted2017-04-04 00:00:00
Date Available2017-04-04 00:00:00
Creation Date2017-03-27 16:14:41
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2017-03-27 16:31:30
Document Titlehid_pls8-us.book
Document CreatorFrameMaker 2015.0.5
Document Author: chinrich

Cinterion® PLS8-US R4
Hardware Interface Overview
Version: 03.915
DocId: PLS8-USR4_HIO_v03.915
 M2M.GEMALTO.COM
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 2 of 44
Document Name:
Cinterion® PLS8-US R4 Hardware Interface Overview
Version:
03.915
Date:
2017-03-27
DocId:
PLS8-USR4_HIO_v03.915
Status
Confidential / Preliminary
GENERAL NOTE
THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE "PRODUCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY
EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS
INFORMATION ON GEMALTO M2M PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT ARE
SUBJECT TO CHANGE AT GEMALTO M2M'S DISCRETION. GEMALTO M2M GMBH GRANTS A NONEXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHALL NOT TRANSFER, COPY,
MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE DERIVATIVE WORKS; DISASSEMBLE OR
DECOMPILE THE PRODUCT OR OTHERWISE USE THE PRODUCT EXCEPT AS SPECIFICALLY
AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN "AS IS" BASIS ONLY
AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM EXTENT PERMITTED
BY APPLICABLE LAW, GEMALTO M2M GMBH DISCLAIMS ALL WARRANTIES AND LIABILITIES.
THE RECIPIENT UNDERTAKES FOR AN UNLIMITED PERIOD OF TIME TO OBSERVE SECRECY
REGARDING ANY INFORMATION AND DATA PROVIDED TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT. THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED
ACCORDING TO GERMAN LAW.
Copyright
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be
held liable for payment of damages. All rights created by patent grant or registration of a utility model or
design patent are reserved.
Copyright © 2017, Gemalto M2M GmbH, a Gemalto Company
Trademark Notice
Gemalto, the Gemalto logo, are trademarks and service marks of Gemalto and are registered in certain
countries. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other registered trademarks or trademarks mentioned
in this document are property of their respective owners.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 3 of 44
Contents
44
Contents
Document History ....................................................................................................... 6
Introduction ................................................................................................................. 7
1.1
Supported Products ........................................................................................... 7
1.2
Related Documents ........................................................................................... 7
1.3
Terms and Abbreviations ................................................................................... 7
1.4
Regulatory and Type Approval Information ..................................................... 10
1.4.1 Directives and Standards.................................................................... 10
1.4.2 SAR requirements specific to portable mobiles .................................. 13
1.4.3 SELV Requirements ........................................................................... 14
1.4.4 Safety Precautions.............................................................................. 14
Product Concept ....................................................................................................... 15
2.1
Key Features at a Glance ................................................................................ 15
2.2
PLS8-US R4 System Overview ....................................................................... 18
Application Interface................................................................................................. 19
3.1
Operating Modes ............................................................................................. 20
3.2
Power Supply................................................................................................... 21
3.3
USB Interface................................................................................................... 22
3.4
Serial Interface ASC0 ...................................................................................... 23
3.5
UICC/SIM/USIM Interface................................................................................ 24
3.6
Digital Audio Interface...................................................................................... 26
3.7
Analog-to-Digital Converter (ADC)................................................................... 26
3.8
GPIO Interface ................................................................................................. 26
GNSS Receiver .......................................................................................................... 27
Antenna Interfaces.................................................................................................... 28
5.1
GSM/UMTS/LTE Antenna Interface................................................................. 28
5.1.1 Antenna Installation ............................................................................ 29
5.1.2 RF Line Routing Design...................................................................... 30
5.1.2.1 Line Arrangement Examples ............................................... 30
5.1.2.2 Routing Example................................................................. 32
5.2
GNSS Antenna Interface ................................................................................. 33
Mechanics.................................................................................................................. 35
6.1
Mechanical Dimensions of PLS8-US R4 ......................................................... 35
Sample Application................................................................................................... 37
Reference Approval .................................................................................................. 39
8.1
Reference Equipment for Type Approval ......................................................... 39
8.2
Compliance with FCC and IC Rules and Regulations ..................................... 40
Appendix.................................................................................................................... 42
9.1
List of Parts and Accessories........................................................................... 42

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 4 of 44
Tables
44
Tables
Table 1:
Table 2:
Table 3:
Table 4:
Table 5:
Table 6:
Table 7:
Table 8:
Table 9:
Table 10:
Table 11:
Table 12:
Table 13:

Directives .......................................................................................................
Standards of North American type approval ..................................................
Standards of European type approval............................................................
Requirements of quality .................................................................................
Standards of the Ministry of Information Industry of the
People’s Republic of China ............................................................................
Toxic or hazardous substances or elements with defined concentration
limits ...............................................................................................................
Overview of operating modes ........................................................................
Signals of the SIM interface (SMT application interface) ...............................
Return loss in the active band........................................................................
Antenna gain limits for FCC and IC................................................................
List of parts and accessories..........................................................................
Molex sales contacts (subject to change) ......................................................
Hirose sales contacts (subject to change) .....................................................
PLS8-USR4_HIO_v03.915
Confidential / Preliminary
10
10
10
11
12
12
20
24
28
40
42
43
43
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 5 of 44
Figures
44
Figures
Figure 1:
Figure 2:
Figure 3:
Figure 4:
Figure 5:
Figure 6:
Figure 7:
Figure 8:
Figure 9:
Figure 10:
Figure 11:
Figure 12:
Figure 13:
Figure 14:
Figure 15:
Figure 16:

PLS8-US R4 system overview .......................................................................
Decoupling capacitor(s) for BATT+................................................................
USB circuit .....................................................................................................
Serial interface ASC0.....................................................................................
First UICC/SIM/USIM interface ......................................................................
Second UICC/SIM/USIM interface .................................................................
Embedded Stripline line arrangement............................................................
Micro-Stripline line arrangement samples......................................................
Routing to application‘s RF connector ...........................................................
PLS8-US R4 evaluation board layer table .....................................................
Supply voltage for active GNSS antenna.......................................................
ESD protection for passive GNSS antenna ...................................................
PLS8-US R4 – top and bottom view ..............................................................
Dimensions of PLS8-US R4 (all dimensions in mm)......................................
PLS8-US R4 sample application....................................................................
Reference equipment for type approval .........................................................
PLS8-USR4_HIO_v03.915
Confidential / Preliminary
18
21
22
23
25
25
30
31
32
32
33
34
35
36
38
39
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 6 of 44
0 Document History
Document History
New document: "Cinterion® PLS8-US Hardware Interface Overview" v03.915
Chapter
What is new
---
Initial document setup.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 7 of 44
1 Introduction
14
Introduction
The document1 describes the hardware of the Cinterion® PLS8-US R4 module, designed to
connect to a cellular device application and the air interface. It helps you quickly retrieve interface specifications, electrical and mechanical details and information on the requirements to be
considered for integrating further components.
1.1
Supported Products
This document applies to the following Gemalto M2M products:
• Cinterion® PLS8-US R4 module
1.2
[1]
[2]
[3]
[4]
Related Documents
AT Command Set for your Gemalto M2M product
Release Notes for your Gemalto M2M product
Application Note 48: SMT Module Integration
Universal Serial Bus Specification Revision 2.0, April 27, 2000
1.3
Terms and Abbreviations
Abbreviation
Description
AMR
Adaptive Multirate
ANSI
American National Standards Institute
ARP
Antenna Reference Point
BIP
Bearer Independent Protocol
CE
Conformité Européene (European Conformity)
CS
Coding Scheme
CS
Circuit Switched
CSD
Circuit Switched Data
CSFB
Circuit Switched Fallback
DCS
Digital Cellular System
DL
Download
dnu
Do not use
DRX
Discontinuous Reception
DSB
Development Support Board
1.
The document is effective only if listed in the appropriate Release Notes as part of the technical documentation delivered with your Gemalto M2M product.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 8 of 44
1.3 Terms and Abbreviations
14
Abbreviation
Description
DTX
Discontinuous Transmission
EDGE
Enhanced Data rates for GSM Evolution
EFR
Enhanced Full Rate
EGSM
Extended GSM
EMC
Electromagnetic Compatibility
ESD
Electrostatic Discharge
ETS
European Telecommunication Standard
ETSI
European Telecommunications Standards Institute
FCC
Federal Communications Commission (U.S.)
FDD
Frequency Division Duplex
FR
Full Rate
GPRS
General Packet Radio Service
GSM
Global Standard for Mobile Communications
HiZ
High Impedance
HR
Half Rate
HSDPA
High Speed Downlink Packet Access
I/O
Input/Output
IMEI
International Mobile Equipment Identity
ISO
International Standards Organization
ITU
International Telecommunications Union
kbps
kbits per second
LED
Light Emitting Diode
LGA
Land Grid Array
LTE
Long term evolution
MBB
Moisture barrier bag
Mbps
Mbits per second
MCS
Modulation and Coding Scheme
MIMO
Multiple Input Multiple Output
MLCC
Multi Layer Ceramic Capacitor
MO
Mobile Originated
MS
Mobile Station, also referred to as TE
MSL
Moisture Sensitivity Level
MT
Mobile Terminated
nc
Not connected
NTC
Negative Temperature Coefficient
PCB
Printed Circuit Board

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 9 of 44
1.3 Terms and Abbreviations
14
Abbreviation
Description
PCL
Power Control Level
PCS
Personal Communication System, also referred to as GSM 1900
PD
Pull Down resistor
PDU
Protocol Data Unit
PS
Packet Switched
PSK
Phase Shift Keying
PU
Pull Up resistor
QAM
Quadrature Amplitude Modulation
R&TTE
Radio and Telecommunication Terminal Equipment
RF
Radio Frequency
rfu
Reserved for future use
ROPR
Radio Output Power Reduction
RTC
Real Time Clock
Rx
Receive Direction
SAR
Specific Absorption Rate
SELV
Safety Extra Low Voltage
SIM
Subscriber Identification Module
SMD
Surface Mount Device
SMS
Short Message Service
SMT
Surface Mount Technology
SRAM
Static Random Access Memory
SRB
Signaling Radio Bearer
TE
Terminal Equipment
TPC
Transmit Power Control
TS
Technical Specification
Tx
Transmit Direction
UL
Upload
UMTS
Universal Mobile Telecommunications System
URC
Unsolicited Result Code
USB
Universal Serial Bus
UICC
USIM Integrated Circuit Card
USIM
UMTS Subscriber Identification Module
USAT
U/SIM Application Toolkit
WB-AMR
Wideband Adaptive Multirate
WCDMA
Wideband Code Division Multiple Access

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 10 of 44
1.4 Regulatory and Type Approval Information
14
1.4
Regulatory and Type Approval Information
1.4.1
Directives and Standards
PLS8-US R4 has been designed to comply with the directives and standards listed below.
It is the responsibility of the application manufacturer to ensure compliance of the final product
with all provisions of the applicable directives and standards as well as with the technical specifications provided in the "PLS8-US R4 Hardware Interface Description".1
Table 1: Directives
99/05/EC
Directive of the European Parliament and of the council of 9 March 1999 on
radio equipment and telecommunications terminal equipment and the
mutual recognition of their conformity (in short referred to as R&TTE Directive 1999/5/EC).
The product is labeled with the CE conformity mark
2002/95/EC (RoHS 1)
2011/65/EC (RoHS 2)
Directive of the European Parliament and of the Council of
27 January 2003 (and revised on 8 June 2011) on the
restriction of the use of certain hazardous substances in
electrical and electronic equipment (RoHS)
Table 2: Standards of North American type approval
CFR Title 47
Code of Federal Regulations, Part 22, Part 24 and Part 27; US Equipment
Authorization FCC
OET Bulletin 65
(Edition 97-01)
Evaluating Compliance with FCC Guidelines for Human Exposure to
Radiofrequency Electromagnetic Fields
UL 60 950-1
Product Safety Certification (Safety requirements)
NAPRD.03 V5.30
Overview of PCS Type certification review board Mobile Equipment Type
Certification and IMEI control
PCS Type Certification Review board (PTCRB)
RSS130, RSS132,
RSS133, RSS139
Canadian Standard
Table 3: Standards of European type approval
3GPP TS 51.010-1
Digital cellular telecommunications system (Release 7); Mobile Station
(MS) conformance specification;
ETSI EN 301 511
V12.1.1
Global System for Mobile communications (GSM); Harmonized standard for
mobile stations in the GSM 900 and DCS 1800 bands covering essential
requirements under article 3.2 of the R&TTE directive (1999/5/EC)
GCF-CC V3.64
Global Certification Forum - Certification Criteria
ETSI EN 301 489-01
V1.9.2
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services;
Part 1: Common Technical Requirements
1.
Manufacturers of applications which can be used in the US shall ensure that their applications have a
PTCRB approval. For this purpose they can refer to the PTCRB approval of the respective module.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 11 of 44
1.4 Regulatory and Type Approval Information
14
Table 3: Standards of European type approval
ETSI EN 301 489-03
V1.6.1
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services;
Part 1: Specific requirements for Short-Range Devices (SRD) operating on
frequencies between 9 kHz and 25 GHz
ETSI EN 301 489-07
V1.3.1
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services;
Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)
EN 300 440-02 V1.4.1
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short
range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN covering essential requirements of
article 3.2 of the R&TTE Directive
EN 62311:2008
Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)
IEC/EN 60950-1:2006+
A11:2009+A1:2010+
A12:2011+A2:2013
Safety of information technology equipment
Table 4: Requirements of quality
IEC 60068
Environmental testing
DIN EN 60529
IP codes

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 12 of 44
1.4 Regulatory and Type Approval Information
14
Table 5: Standards of the Ministry of Information Industry of the People’s Republic of China
SJ/T 11363-2006
“Requirements for Concentration Limits for Certain Hazardous Substances
in Electronic Information Products” (2006-06).
SJ/T 11364-2006
“Marking for Control of Pollution Caused by Electronic
Information Products” (2006-06).
According to the “Chinese Administration on the Control of
Pollution caused by Electronic Information Products”
(ACPEIP) the EPUP, i.e., Environmental Protection Use
Period, of this product is 20 years as per the symbol
shown here, unless otherwise marked. The EPUP is valid only as long as
the product is operated within the operating limits described in the Hardware
Interface Description.
Please see Table 6 for an overview of toxic or hazardous substances or elements that might be contained in product parts in concentrations above the
limits defined by SJ/T 11363-2006.
Table 6: Toxic or hazardous substances or elements with defined concentration limits

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 13 of 44
1.4 Regulatory and Type Approval Information
14
1.4.2
SAR requirements specific to portable mobiles
Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM/UMTS/
LTE module must be in accordance with the guidelines for human exposure to radio frequency
energy. This requires the Specific Absorption Rate (SAR) of portable PLS8-US R4 based applications to be evaluated and approved for compliance with national and/or international regulations.
Since the SAR value varies significantly with the individual product design manufacturers are
advised to submit their product for approval if designed for portable use. For US markets the
relevant directives are mentioned below. It is the responsibility of the manufacturer of the final
product to verify whether or not further standards, recommendations or directives are in force
outside these areas.
Products intended for sale on US markets
ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to electromagnetic
fields (EMFs) from mobile telecommunication equipment (MTE) in the
frequency range 30MHz - 6GHz
IMPORTANT:
Manufacturers of portable applications based on PLS8-US R4 modules are required to have
their final product certified and apply for their own FCC Grant and Industry Canada Certificate
related to the specific portable mobile.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 14 of 44
1.4 Regulatory and Type Approval Information
14
1.4.3
SELV Requirements
The power supply connected to the PLS8-US R4 module shall be in compliance with the SELV
requirements defined in EN 60950-1.
1.4.4
Safety Precautions
The following safety precautions must be observed during all phases of the operation, usage,
service or repair of any cellular terminal or mobile incorporating PLS8-US R4. Manufacturers
of the cellular terminal are advised to convey the following safety information to users and operating personnel and to incorporate these guidelines into all manuals supplied with the product. Failure to comply with these precautions violates safety standards of design, manufacture
and intended use of the product. Gemalto M2M assumes no liability for customer’s failure to
comply with these precautions.
When in a hospital or other health care facility, observe the restrictions on the use of
mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guidelines posted in sensitive areas. Medical equipment may be sensitive to RF energy.
The operation of cardiac pacemakers, other implanted medical equipment and hearing
aids can be affected by interference from cellular terminals or mobiles placed close to
the device. If in doubt about potential danger, contact the physician or the manufacturer of the device to verify that the equipment is properly shielded. Pacemaker
patients are advised to keep their hand-held mobile away from the pacemaker, while
it is on.
Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it cannot be switched on inadvertently. The operation of wireless appliances in an aircraft is
forbidden to prevent interference with communications systems. Failure to observe
these instructions may lead to the suspension or denial of cellular services to the
offender, legal action, or both.
Do not operate the cellular terminal or mobile in the presence of flammable gases or
fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots,
chemical plants or where blasting operations are in progress. Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety hazard.
Your cellular terminal or mobile receives and transmits radio frequency energy while
switched on. Remember that interference can occur if it is used close to TV sets,
radios, computers or inadequately shielded equipment. Follow any special regulations
and always switch off the cellular terminal or mobile wherever forbidden, or when you
suspect that it may cause interference or danger.
IMPORTANT!
Cellular terminals or mobiles operate using radio signals and cellular networks.
Because of this, connection cannot be guaranteed at all times under all conditions.
Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls.
Remember, in order to make or receive calls, the cellular terminal or mobile must be
switched on and in a service area with adequate cellular signal strength.
Some networks do not allow for emergency calls if certain network services or phone
features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate
those features before you can make an emergency call.
Some networks require that a valid SIM card be properly inserted in the cellular terminal or mobile.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 15 of 44
2 Product Concept
18
Product Concept
2.1
Key Features at a Glance
Feature
Implementation
General
Frequency bands
GSM/GPRS/EDGE: Quad band, 850/900/1800/1900MHz
UMTS/HSPA+: Triple band, 850 (BdV) / AWS (BdIV) / 1900MHz (BdII)
LTE: Quad band, 700 (Bd17) / 850 (Bd5) / AWS (Bd4) / 1900MHz (Bd2)
GSM class
Small MS
Output power (according to Class 4 (+33dBm ±2dB) for EGSM850
Release 99)
Class 4 (+33dBm ±2dB) for EGSM900
Class 1 (+30dBm ±2dB) for GSM1800
Class 1 (+30dBm ±2dB) for GSM1900
Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK
Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK
Class 3 (+24dBm +1/-3dB) for UMTS 1900,WCDMA FDD BdII
Class 3 (+24dBm +1/-3dB) for UMTS AWS, WCDMA FDD BdIV
Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV
Output power (according to Class 3 (+23dBm +-2dB) for LTE 1900, LTE FDD Bd2
Release 8)
Class 3 (+23dBm +-2dB) for LTE AWS, LTE FDD Bd4
Class 3 (+23dBm +-2dB) for LTE 850, LTE FDD Bd5
Class 3 (+23dBm +-2dB) for LTE 700, LTE FDD Bd17
Power supply
3.3V < VBATT+ < 4.2V
Operating temperature
(board temperature)
Normal operation: -30°C to +85°C
Extended operation: -40°C to +95°C
Physical
Dimensions: 33mm x 29mm x 2.2mm
Weight: approx. 4.5g
RoHS
All hardware components fully compliant with EU RoHS Directive
LTE features
3GPP Release 9
UE CAT 3 supported
DL 100Mbps, UL 50Mbps
2x2 MIMO in DL direction
HSPA features
3GPP Release 8
UE CAT. 14, 24
DC-HSPA+ – DL 42Mbps
HSUPA – UL 5.76Mbps
Compressed mode (CM) supported according to 3GPP TS25.212
UMTS features
3GPP Release 8

PS data rate – 384 kbps DL / 384 kbps UL
PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 16 of 44
2.1 Key Features at a Glance
18
Feature
Implementation
GSM / GPRS / EGPRS features
Data transfer
GPRS:
• Multislot Class 12
• Mobile Station Class B
• Coding Scheme 1 – 4
EGPRS:
• Multislot Class 12
• EDGE E2 power class for 8 PSK
• Downlink coding schemes – CS 1-4, MCS 1-9
• Uplink coding schemes – CS 1-4, MCS 1-9
• SRB loopback and test mode B
• 8-bit, 11-bit RACH
• 1 phase/2 phase access procedures
• Link adaptation and IR
• NACC, extended UL TBF
• Mobile Station Class B
SMS
Point-to-point MT and MO
Cell broadcast
Text and PDU mode
Software
AT commands
Hayes, 3GPP TS 27.007 and 27.005, and proprietary Gemalto M2M commands
Firmware update
Generic update from host application over USB and ASC0
U/SIM application toolkit
USAT letter c; with BIP
Audio
Audio speech codecs
GSM: WB-AMR, AMR, EFR, FR, HR
3GPP: WB-AMR, AMR
Speakerphone operation, echo cancellation, noise suppression, 9 ringing
tones
VoLTE support for multiple operators, with CSFB
GNSS Features
Protocol
NMEA (for GPS, GLONASS and Galileo related sentences)
Modes
Standalone GNSS
Assisted GNSS
- Control plane - E911
- User plane - gpsOneXTRA™
General
Power saving modes
Power supply for active antenna
Interfaces
Module interface

Surface mount device with solderable connection pads (SMT application
interface).
Land grid array (LGA) technology ensures high solder joint reliability and
provides the possibility to use an optional module mounting socket.
For more information on how to integrate SMT modules see also [3]. This
application note comprises chapters on module mounting and application
layout issues as well as on additional SMT application development
equipment.
PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 17 of 44
2.1 Key Features at a Glance
18
Feature
Implementation
Antenna
50. GSM/UMTS/LTE main antenna, UMTS/LTE Diversity/MIMO
antenna, (active/passive) GNSS antenna
USB
USB 2.0 High Speed (480Mbit/s) device interface
Serial interface
ASC0:
• 8-wire modem interface with status and control lines, unbalanced,
asynchronous
• Adjustable baud rates: 115,200bps to 921,600bps
• Supports RTS0/CTS0 hardware flow control
UICC interface
2 UICC interfaces (switchable)
Supported chip cards: UICC/SIM/USIM 3V, 1.8V
Audio
1 digital interface (PCM or I2S)
Status
Signal line to indicate network connectivity state
RING0
Signal line to indicate incoming calls and other types of URCs
Power on/off, Reset
Power on/off
Switch-on by hardware signal IGT
Switch-off by AT command (AT^SMSO) or IGT
Automatic switch-off in case of critical temperature or voltage conditions
Reset
Orderly shutdown and reset by AT command
Emergency-off
Emergency-off by hardware signal EMERG_OFF if IGT is not active
Special Features
Antenna
SAIC (Single Antenna Interference Cancellation) / DARP (Downlink
Advanced Receiver Performance)
Rx Diversity (receiver type 3i - 64-QAM) / MIMO
GPIO
10 I/O pins of the application interface programmable as GPIO.
GPIOs can be configured as low current indicator (LCI).
GPIO1 can be configured as dead reckoning synchronization signal.
GPIO2 can be configured as 700MHz antenna switch control signal.
GPIOs can be configured as remote host wakeup lines.
Programming is done via AT commands.
ADC inputs
Analog-to-Digital Converter with three unbalanced analog inputs.
Evaluation kit
Evaluation module
PLS8-US R4 module soldered onto a dedicated PCB that can be connected to an adapter in order to be mounted onto the DSB75.
DSB75
DSB75 Development Support Board designed to test and type approve
Gemalto M2M modules and provide a sample configuration for application engineering. A special adapter is required to connect the PLS8-US
R4 evaluation module to the DSB75.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 18 of 44
2.2 PLS8-US R4 System Overview
18
2.2
PLS8-US R4 System Overview
GSM/UMTS/LTE
Antenna diversity
GNSS antenna
Application
GNSS active
antenna supply,
current limiter
Serial
ASC0
ADC
Modem interface
USB
Host application
GPIO
Module
GSM/UMTS/LTE
GNSS
UICC
SIM
card
SIM
card
Power
supply
Digital
audio
PCM or I2S
codec
Power for application
(VEXT)
Power indication
(PWR_IND)
Power
supply
RTC
IGT,
Emergency Off
Net state/
status
or
On/Off
Figure 1: PLS8-US R4 system overview

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 19 of 44
3 Application Interface
27
Application Interface
PLS8-US R4 is equipped with an SMT application interface (LGA pads) that connects to the
external application. The host interface incorporates several sub-interfaces described in the following sections:
•
•
•
•
•
•
•
•
Operating modes - see Section 3.1
Power supply - see Section 3.2
Serial interface USB - see Section 3.3
Serial interface ASC0 - Section 3.4
UICC/SIM/USIM interface - see Section 3.5
Digital audio interface (PCM or I2S) - see Section 3.6
ADC interface - Section 3.7
GPIO interface - Section 3.8

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 20 of 44
3.1 Operating Modes
27
3.1
Operating Modes
The table below briefly summarizes the various operating modes referred to in the following
chapters.
Table 7: Overview of operating modes
Mode
Function
Normal
GSM / GPRS /
operation UMTS / HSPA /
LTE SLEEP
Power saving set automatically when no call is in progress and the USB
connection is detached and no active communication via ASC0. Also,
the GNSS active antenna mode has to be turned off or set to "auto".
GSM / GPRS /
UMTS / HSPA /
LTE IDLE
Power saving disabled or an USB connection active, but no data transfer in progress.
GPRS DATA
GPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and
GPRS configuration (e.g. used multislot settings).
EGPRS DATA
EGPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and
EGPRS configuration (e.g. used multislot settings).
UMTS DATA
UMTS data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate.
HSPA DATA
HSPA data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate.
LTE DATA
LTE data transfer in progress. Power consumption depends on network
settings (e.g. TPC Pattern) and data transfer rate.
Power
Down
Normal shutdown after sending the AT^SMSO command. Only a voltage regulator is active
for powering the RTC. Software is not active. Interfaces are not accessible. Operating voltage (connected to BATT+) remains applied.
Airplane
mode
Airplane mode shuts down the radio part of the module, causes the module to log off from
the GSM/GPRS network and disables all AT commands whose execution requires a radio
connection.
Airplane mode can be controlled by AT command (see [1]).

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 21 of 44
3.2 Power Supply
27
3.2
Power Supply
PLS8-US R4 needs to be connected to a power supply at the SMT application interface - 4 lines
BATT+, and GND. There are two separate voltage domains for BATT+:
• BATT+_RF with 2 lines for the RF power amplifier supply
• BATT+ with 2 lines for the general power management.
The main power supply from an external application has to be a single voltage source and has
to be expanded to two sub paths (star structure). Each voltage domain must be decoupled by
application with low ESR capacitors (> 47µF MLCC @ BATT+; > 4x47µF MLCC @ BATT+_RF)
as close as possible to LGA pads. Figure 2 shows a sample circuit for decoupling capacitors
for BATT+.
Module
1x
SMT interface
BATT+
BATT+_RF
BATT+
4x
Decoupling capacitors
e.g. 47µF X5R MLCC
GND
Figure 2: Decoupling capacitor(s) for BATT+
The power supply of PLS8-US R4 must be able to provide the peak current during the uplink
transmission.
All key functions for supplying power to the device are handled by the power management IC.
It provides the following features:
• Stabilizes the supply voltages for the baseband using switching regulators and low drop linear voltage regulators.
• Switches the module's power voltages for the power-up and -down procedures.
• Delivers, across the VEXT line, a regulated voltage for an external application.
• LDO to provide SIM power supply.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 22 of 44
3.3 USB Interface
27
3.3
USB Interface
PLS8-US R4 supports a USB 2.0 High Speed (480Mbps) device interface. The USB interface
is primarily intended for use as command and data interface and for downloading firmware.
The USB host is responsible for supplying the VUSB_IN line. This line is for voltage detection
only. The USB part (driver and transceiver) is supplied by means of BATT+. This is because
PLS8-US R4 is designed as a self-powered device compliant with the “Universal Serial Bus
Specification Revision 2.0”1.
Module
SMT
VREG (3V075)
BATT+
GND
lin. reg.
USB part1)
VBUS
Detection only
VUSB_IN 2)
1µF
RS
DP
DN
RS
Host wakeup
USB_DP 3)
USB_DN 3)
RING0
1)
All serial (including R S ) and pull-up resistors for data lines are implemented .
Since VUSB_IN is used for detection only it is recommended not to add any further
blocking capacitors on the VUSB _IN line.
2)
3)
If the USB interface is operated in High Speed mode (480MHz), it is recommended to take
special care routing the data lines USB _DP and USB_DN. Application layout should in this
case implement a differential impedance of 90 ohms for proper signal integrity.
Figure 3: USB circuit
To properly connect the module's USB interface to the external application, a USB 2.0 compatible connector and cable or hardware design is required. Furthermore, the USB modem driver
distributed with PLS8-US R4 needs to be installed.
1.
The specification is ready for download on http://www.usb.org/developers/docs/usb20_docs/

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 23 of 44
3.4 Serial Interface ASC0
27
3.4
Serial Interface ASC0
PLS8-US R4 offers an 8-wire unbalanced, asynchronous modem interface ASC0 conforming
to ITU-T V.24 protocol DCE signaling. The electrical characteristics do not comply with ITU-T
V.28. The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit
or inactive state).
PLS8-US R4 is designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals:
• Port TXD @ application sends data to the module’s TXD0 signal line
• Port RXD @ application receives data from the module’s RXD0 signal line
Figure 4: Serial interface ASC0
Features:
• Includes the data lines TXD0 and RXD0, the status lines RTS0 and CTS0 and, in addition,
the modem control lines DTR0, DSR0, DCD0 and RING0.
• The RING0 signal serves to indicate incoming calls and other types of URCs (Unsolicited
Result Code). It can also be configured to send pulses to the host application, for example
to remotely wake up the application from power saving state. See [1] for details on how to
configure the RING0 line by AT^SCFG.
• Configured for 8 data bits, no parity and 1 stop bit.
• ASC0 can be operated at fixed bit rates from 115200bps up to 921600bps.
• Supports RTS0/CTS0 hardware flow control.
• Wake up from SLEEP mode by RTS0 activation.
Note: If the ASC0 serial interface is the application’s only interface, it is suggested to connect
test points on the USB signal lines as a potential tracing possibility.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 24 of 44
3.5 UICC/SIM/USIM Interface
27
3.5
UICC/SIM/USIM Interface
PLS8-US R4 has two integrated UICC/SIM/USIM interfaces compatible with the 3GPP 31.102
and ETSI 102 221. These are wired to the host interface in order to be connected to an external
SIM card holder. Five pads on the SMT application interface are reserved for each of the SIM
two interfaces.
The UICC/SIM/USIM interfaces support 3V and 1.8V SIM cards.
The CCINx signal serves to detect whether a tray (with SIM card) is present in the card holder.
Using the CCINx signal is mandatory for compliance with the GSM 11.11 recommendation if
the mechanical design of the host application allows the user to remove the SIM card during
operation. To take advantage of this feature, an appropriate SIM card detect switch is required
on the card holder. For example, this is true for the model supplied by Molex, which has been
tested to operate with PLS8-US R4 and is part of the Gemalto M2M reference equipment submitted for type approval. See Chapter 9 for Molex ordering numbers.
Table 8: Signals of the SIM interface (SMT application interface)
Signal
Description
GND
Ground connection for SIM interfaces. Optionally a separate SIM ground line using e.g.,
pad N11 may be used to improve EMC.
CCCLK1
CCCLK2
Chipcard clock lines for 1st and 2nd SIM interface.
CCVCC1 SIM supply voltage lines for 1st and 2nd SIM interface.
CCVCC2
CCIO1
CCIO2
Serial data lines for 1st and 2nd SIM interface, input and output.
CCRST1 Chipcard reset lines for 1st and 2nd SIM interface.
CCRST2
CCIN1
CCIN2
Input on the baseband processor for detecting a SIM card tray in the holder. If the SIM is
removed during operation the SIM interface is shut down immediately to prevent destruction of the SIM. The CCINx signal is active low.
The CCINx signal is mandatory for applications that allow the user to remove the SIM card
during operation.
The CCINx signal is solely intended for use with a SIM card. It must not be used for any
other purposes. Failure to comply with this requirement may invalidate the type approval of
PLS8-US R4.
Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after
removing the SIM card during operation. Also, no guarantee can be given for properly initializing any SIM card that the user inserts after having removed the SIM card during operation. In
this case, the application must restart PLS8-US R4.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 25 of 44
3.5 UICC/SIM/USIM Interface
27
open: Card removed
closed: Card inserted
SMT application interface
CCIN1
Module
CCRST1
1nF
SIM /
UICC
CCCLK1
GND
CCIO1
CCVCC1
220nF
Figure 5: First UICC/SIM/USIM interface
The total cable length between the SMT application interface pads on PLS8-US R4 and the
pads of the external SIM card holder must not exceed 100mm in order to meet the specifications of 3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance.
To avoid possible cross-talk from the CCCLKx signal to the CCIOx signal be careful that both
lines are not placed closely next to each other. A useful approach is using the GND line to
shield the CCIOx line from the CCCLKx line.
Note: Figure 5 shows how to connect a SIM card holder to the first SIM interface. With the second SIM interface some internally integrated components on the SIM circuit will have to be externally integrated as shown for the second SIM interface in Figure 6.
22k*
Module
SMT application interface
VEXT
CCIN2
Open: Card removed
Closed: Card inserted
2k2
100pF*
CCRST2
1nF
SIM /
UICC
CCCLK2
GND
CCIO2
10k
CCVCC2
220nF
* Should be placed
as close as possible
to SMT application
interface
Figure 6: Second UICC/SIM/USIM interface

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 26 of 44
3.6 Digital Audio Interface
27
3.6
Digital Audio Interface
PLS8-US R4 supports a digital audio interface that can be employed either as pulse code modulation interface or as inter IC sound interface. Operation of these interface variants is mutually
exclusive, and can be configured by AT command (see [1]). Default setting is pulse code modulation.
3.7
Analog-to-Digital Converter (ADC)
PLS8-US R4 provides three unbalanced ADC input lines: ADC1_IN, ADC2_IN and ADC3_IN.
They can be used to measure three independent, externally connected DC voltages in the
range of 0.3V to 3.075V.
3.8
GPIO Interface
PLS8-US R4 has 10 GPIOs for external hardware devices. Each GPIO can be configured for
use as input or output. All settings are AT command controlled.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 27 of 44
4 GNSS Receiver
27
GNSS Receiver
PLS8-US R4 integrates a GNSS receiver that offers the full performance of GPS/GLONASS/
Galileo technology. The GNSS receiver is able to continuously track all satellites in view, thus
providing accurate satellite position data.
The integrated GNSS receiver supports the NMEA protocol via USB or ASC0 interface. NMEA
is a combined electrical and data specification for communication between various (marine)
electronic devices including GNSS receivers. It has been defined and controlled by the US
based National Marine Electronics Association. For more information on the NMEA Standard
please refer to http://www.nmea.org.
Depending on the receiver’s knowledge of last position, current time and ephemeris data, the
receiver’s startup time (i.e., TTFF = Time-To-First-Fix) may vary: If the receiver has no knowledge of its last position or time, a startup takes considerably longer than if the receiver has still
knowledge of its last position, time and almanac or has still access to valid ephemeris data and
the precise time.
By default, the GNSS receiver is switched off. It has to be switched on and configured using AT
commands. For more information on how to control the GNSS interface via the AT commands
see [1].

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 28 of 44
5 Antenna Interfaces
34
Antenna Interfaces
5.1
GSM/UMTS/LTE Antenna Interface
The PLS8-US R4 GSM/UMTS/LTE antenna interface comprises a GSM/UMTS/LTE main antenna as well as a UMTS/LTE Rx diversity/MIMO antenna to improve signal reliability and quality1. The interface has an impedance of 50. PLS8-US R4 is capable of sustaining a total
mismatch at the antenna interface without any damage, even when transmitting at maximum
RF power.
The external antennas must be matched properly to achieve best performance regarding radiated power, modulation accuracy and harmonic suppression. Matching networks are not included on the PLS8-US R4 PCB and should be placed in the host application, if the antenna
does not have an impedance of 50.
Regarding the return loss PLS8-US R4 provides the following values in the active band:
Table 9: Return loss in the active band
State of module
Return loss of module
Recommended return loss of application
Receive
> 8dB
> 12dB
Transmit
not applicable
> 12dB
Idle
< 5dB
not applicable
1.
By delivery default the UMTS/LTE Rx diversity/MIMO antenna is configured as available for the module
since its usage is mandatory for LTE. Please refer to [1] for details on how to configure antenna settings.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 29 of 44
5.1 GSM/UMTS/LTE Antenna Interface
34
5.1.1
Antenna Installation
The antenna is connected by soldering the antenna pads (ANT_MAIN; ANT_DRX_MIMO) and
their neighboring ground pads directly to the application’s PCB.
The distance between the antenna pads and their neighboring GND pads has been optimized
for best possible impedance. To prevent mismatch, special attention should be paid to these
pads on the application’ PCB.
The wiring of the antenna connection, starting from the antenna pad to the application’s antenna should result in a 50 line impedance. Line width and distance to the GND plane need to
be optimized with regard to the PCB’s layer stack.
To prevent receiver desensitization due to interferences generated by fast transients like high
speed clocks on the external application PCB, it is recommended to realize the antenna connection line using embedded Stripline rather than Micro-Stripline technology. Please see Section 5.1.2 for examples of how to design the antenna connection in order to achieve the
required 50 line impedance.
For type approval purposes, the use of a 50 coaxial antenna connector (U.FL-R-SMT) might
be necessary. In this case the U.FL-R-SMT connector should be placed as close as possible
to PLS8-US R4‘s antenna pad.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 30 of 44
5.1 GSM/UMTS/LTE Antenna Interface
34
5.1.2
5.1.2.1
RF Line Routing Design
Line Arrangement Examples
Several dedicated tools are available to calculate line arrangements for specific applications
and PCB materials - for example from http://www.polarinstruments.com/ (commercial software)
or from http://web.awrcorp.com/Usa/Products/Optional-Products/TX-Line/ (free software).
Embedded Stripline
This below figure shows line arrangement examples for embedded stripline.
Figure 7: Embedded Stripline line arrangement

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 31 of 44
5.1 GSM/UMTS/LTE Antenna Interface
34
Micro-Stripline
This section gives two line arrangement examples for micro-stripline.
Figure 8: Micro-Stripline line arrangement samples

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 32 of 44
5.1 GSM/UMTS/LTE Antenna Interface
34
5.1.2.2
Routing Example
Interface to RF Connector
Figure 9 shows a sample connection of a module‘s antenna pad at the bottom layer of the module PCB with an application PCB‘s coaxial antenna connector. Line impedance depends on line
width, but also on other PCB characteristics like dielectric, height and layer gap. The sample
stripline width of 0.33mm is recommended for an application with a PCB layer stack resembling
the one of the PLS8-US R4 evaluation board shown in Figure 10. For different layer stacks the
stripline width will have to be adapted accordingly.
GND
e.g.
ANT_
MAIN
GND
Stripline (50 ohms) on top
layer of evaluation board from
antenna pad to module edge
Width = 0.33 mm
Ground connection
Edge of module PCB
50 ohms microstrip line
GND
GND
E.g., U.FL antenna
connector
Figure 9: Routing to application‘s RF connector
Figure 10: PLS8-US R4 evaluation board layer table

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 33 of 44
5.2 GNSS Antenna Interface
34
5.2
GNSS Antenna Interface
In addition to the RF antenna interface PLS8-US R4 also has a GNSS antenna interface. The
GNSS pad itself is the same as for the RF antenna interface (see Section 5.1.1).
It is possible to connect active or passive GNSS antennas. In either case they must have 50
impedance. The simultaneous operation of GSM/UMTS/LTE and GNSS is implemented.
PLS8-US R4 provides the supply voltage VGNSS for the GNSS active antenna (3.05V). It has
to be enabled by software when the GNSS receiver becomes active, otherwise VGNSS should
be off (power saving). VGNSS is not short circuit protected. This will have to be provided for by
an external application. The DC voltage should be fed back via ANT_GNSS_DC for coupling
into the GNSS antenna path. Figure 11 shows the flexibility in realizing the power supply for an
active GNSS antenna by giving two sample circuits realizing the supply voltage for an active
GNSS antenna - one with short circuit protection and one with an external LDO employed.
Module
SMT interface
typ 3.05V max. 50mA
Not short circuit protected!
VGNSS
Short circuit
protection
(Imax=50mA)
100nF
ANT_GNSS_DC
Active
GNSS
antenna
(Optional)
10k
1uF
10nH
ESD
protection
ANT_GNSS
To GNSS
receiver
Supply with short circuit protection
External
voltage
Module
SMT interface
Enable
VGNSS
100nF
LDO
ANT_GNSS_DC
Active
GNSS
antenna
(Optional)
10k
10nH
1uF
ESD
protection
ANT_GNSS
To GNSS
receiver
Supply with external LDO employed
Figure 11: Supply voltage for active GNSS antenna

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 34 of 44
5.2 GNSS Antenna Interface
34
Figure 12 shows sample circuits realizing ESD protection for a passive GNSS antenna.
Module
SMT interface
VGNSS
100nF
Not used
ANT_GNSS_DC
(Optional)
0R
ESD
protection
Passive
GNSS
antenna
10nH
ANT_GNSS
To GNSS
receiver
Figure 12: ESD protection for passive GNSS antenna

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 35 of 44
6 Mechanics
36
Mechanics
6.1
Mechanical Dimensions of PLS8-US R4
Figure 13 shows a 3D view1 of PLS8-US R4 and provides an overview of the board's mechanical dimensions. For further details see Figure 14.
Length:
33mm
Width:
29mm
Height:
2.2mm
Top view
Bottom view
Figure 13: PLS8-US R4 – top and bottom view
1.
The coloring of the 3D view does not reflect the module’s real color.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 36 of 44
6.1 Mechanical Dimensions of PLS8-US R4
36
Internal use;
Not to be soldered
Figure 14: Dimensions of PLS8-US R4 (all dimensions in mm)

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 37 of 44
7 Sample Application
38
Sample Application
Figure 15 shows a typical example of how to integrate an PLS8-US R4 module with an application.
The PWR_IND line is an open collector that needs an external pull-up resistor which connects
to the voltage supply VCC µC of the microcontroller. Low state of the open collector pulls the
PWR_IND signal low and indicates that the PLS8-US R4 module is active, high level notifies
the Power Down mode.
If the module is in Power Down mode avoid current flowing from any other source into the module circuit, for example reverse current from high state external control lines. Therefore, the
controlling application must be designed to prevent reverse flow.
While developing SMT applications it is strongly recommended to provide test points
for certain signals, i.e., lines to and from the module - for debug and/or test purposes.
The SMT application should allow for an easy access to these signals. For details on
how to implement test points see [3].
The EMC measures are best practice recommendations. In fact, an adequate EMC strategy for
an individual application is very much determined by the overall layout and, especially, the position of components.
Some LGA pads are connected to clocks or high speed data streams that might interfere with
the module’s antenna. The RF receiver would then be blocked at certain frequencies (self interference). The external application’s PCB tracks connected to these pads should therefore
be well shielded or kept away from the antenna. This applies especially to the USB and UICC/
SIM interfaces.
Disclaimer:
No warranty, either stated or implied, is provided on the sample schematic diagram shown in
Figure 15 and the information detailed in this section. As functionality and compliance with national regulations depend to a great amount on the used electronic components and the individual application layout manufacturers are required to ensure adequate design and operating
safeguards for their products using PLS8-US R4 modules.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 38 of 44
7 Sample Application
38
ALS3
Current
limiter
<60mA
Figure 15: PLS8-US R4 sample application

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 39 of 44
8 Reference Approval
41
Reference Approval
8.1
Reference Equipment for Type Approval
The Gemalto M2M reference setup submitted to type approve PLS8-US R4 is shown in Figure
16. The module (i.e., the evaluation module) is connected to the DSB75 by means of a flex cable and a special DSB75 adapter. The GSM/UMTS/LTE test equipment is connected via edge
mount SMA connectors soldered to the module’s antenna pads.
For ESD tests and evaluation purposes, it is also possible connect the module to the GSM/
UMTS/LTE test equipment through an SMA-to-Hirose-U.FL antenna cable and the SMA antenna connectors of the DSB75 adapter.
A further option is to mount the evaluation module directly onto the DSB75 adapter’s 80-pin
board-to-board connector and to connect the test equipment as shown below.
A udio
test equipm ent
V otronic
handset
na
lo
ga
ud
io
D etail:
If u
sin
ga
Edge m ount SM A connectors
m an ually soldered to anten na pads
Standard
80 polig Flex
E valuation
m odule
E valuation
m odule
U ranus
USB
SM
At
H ir
os
COM1
(A SC 0)
S IM card
holder
eU
.F L
GNSS
test equipm ent
ca
b le
A N T3
U M TS /LTE R x D iversity/
M IM O
A N T2
G S M /U M TS /LTE
test equipm ent
D S B 75 adapter
A N T1
P ow er
A udio
GND
G S M /U M TS/LTE
A ud io
D S B 75
USB
cable
PC
P ow er
supply
Figure 16: Reference equipment for type approval

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 40 of 44
8.2 Compliance with FCC and IC Rules and Regulations
41
8.2
Compliance with FCC and IC Rules and Regulations
The Equipment Authorization Certification for the Gemalto M2M modules reference application
described in Section 8.1 will be registered under the following identifiers:
•
PLS8-US R4:
FCC Identifier QIPPLS8-USR4
Industry Canada Certification Number: 7830A-PLS8USR4
Granted to Gemalto M2M GmbH
Manufacturers of mobile or fixed devices incorporating PLS8-US R4 modules are authorized
to use the FCC Grants and Industry Canada Certificates of the PLS8-US R4 modules for their
own final products according to the conditions referenced in these documents. In this case, the
FCC label of the module shall be visible from the outside, or the host device shall bear a second
label stating "Contains FCC ID: QIPPLS8-USR4" and accordingly “Contains IC: 7830APLS8USR4“. The integration is limited to fixed or mobile categorized host devices, where a
separation distance between the antenna and any person of min. 20cm can be assured during
normal operating conditions.
For mobile and fixed operation configurations the antenna gain, including cable loss, must not
exceed the limits listed in the following Table 10 for FCC and IC.
Table 10: Antenna gain limits for FCC and IC
Operating band
FCC limit
IC limit
Unit
Maximum gain in lower operating bands with f< 1GHz
(GSM850, WCDMA BdV, LTE Bd5 / Bd17
3.25
0.18
dBi
Maximum gain in higher operating bands with f=1700MHz
(WCDMA BdIV, LTE Bd4)
5.5
5.5
dBi
Maximum gain in higher operating bands with f=1900MHz
(GSM1900, WCDMA BdII, LTE Band 2)
2.51
2.51
dBi
IMPORTANT:
Manufacturers of portable applications incorporating PLS8-US R4 modules are required to
have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. This is mandatory to meet the SAR requirements
for portable mobiles (see Section 1.4 for detail).
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 41 of 44
8.2 Compliance with FCC and IC Rules and Regulations
41
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules and with Industry Canada license-exempt RSS
standard(s). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This Class B digital apparatus complies with Canadian ICES-003.
If Canadian approval is requested for devices incorporating PLS8-US R4 modules the above
note will have to be provided in the English and French language in the final user documentation. Manufacturers/OEM Integrators must ensure that the final user documentation does not
contain any information on how to install or remove the module from the final product.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 42 of 44
9 Appendix
43
Appendix
9.1
List of Parts and Accessories
Table 11: List of parts and accessories
Description
Supplier
Ordering information
PLS8-US R4
Gemalto M2M Standard module
Gemalto M2M IMEI:
Packaging unit (ordering) number: L30960-N3410-A400
Module label number: S30960-S3410-A400-11
Customer IMEI module:
Packaging unit (ordering) number:
L30960-N3415-A400
Module label number:
S30960-S3415-A400-11
PLS8-US R4
Evaluation Module
Gemalto M2M Packaging unit (ordering) number: L30960-N3411-A400
DSB75 Support Box
Gemalto M2M Ordering number: L36880-N8811-A100
DSB75 adapter for mounting the evaluation module
Gemalto M2M Ordering number: L30960-N2301-A100
Votronic handset for
approval purposes
Votronic /
Gemalto M2M ordering number: L36880-N8301-A107
Gemalto M2M Votronic ordering number: HH-SI-30.3/V1.1/0
Votronic
Entwicklungs- und Produktionsgesellschaft für elektronische Geräte mbH
Saarbrücker Str. 8
66386 St. Ingbert
Germany
Phone: +49-(0)6 89 4 / 92 55-0
Fax: +49-(0)6 89 4 / 92 55-88
Email: contact@votronic.com
SIM card holder incl. push
button ejector and slide-in
tray
Molex
Ordering numbers: 91228
91236
Sales contacts are listed in Table 12.
U.FL antenna connector
Hirose or
Molex
Sales contacts are listed in Table 12 and Table 13.
1.
Note: At the discretion of Gemalto M2M, module label information can either be laser engraved on the
module’s shielding or be printed on a label adhered to the module’s shielding.

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
Cinterion® PLS8-US R4 Hardware Interface Overview
Page 43 of 44
9.1 List of Parts and Accessories
43
Table 12: Molex sales contacts (subject to change)
Molex
For further information please click:
http://www.molex.com
Molex Deutschland GmbH
Otto-Hahn-Str. 1b
69190 Walldorf
Germany
Phone: +49-6227-3091-0
Fax: +49-6227-3091-8100
Email: mxgermany@molex.com
American Headquarters
Lisle, Illinois 60532
U.S.A.
Phone: +1-800-78MOLEX
Fax: +1-630-969-1352
Molex China Distributors
Beijing,
Room 1311, Tower B, COFCO Plaza
No. 8, Jian Guo Men Nei Street, 100005
Beijing
P.R. China
Phone: +86-10-6526-9628
Fax: +86-10-6526-9730
Molex Singapore Pte. Ltd.
110, International Road
Jurong Town,
Singapore 629174
Molex Japan Co. Ltd.
1-5-4 Fukami-Higashi,
Yamato-City,
Kanagawa, 242-8585
Japan
Phone: +65-6-268-6868
Fax: +65-6-265-6044
Phone: +81-46-265-2325
Fax: +81-46-265-2365
Table 13: Hirose sales contacts (subject to change)
Hirose Ltd.
For further information please click:
http://www.hirose.com
Hirose Electric (U.S.A.) Inc
2688 Westhills Court
Simi Valley, CA 93065
U.S.A.
Phone: +1-805-522-7958
Fax: +1-805-522-3217
Hirose Electric Europe B.V.
German Branch:
Herzog-Carl-Strasse 4
73760 Ostfildern
Germany
Phone: +49-711-456002-1
Fax: +49-711-456002-299
Email: info@hirose.de
Hirose Electric Europe B.V.
UK Branch:
First Floor, St. Andrews House,
Caldecotte Lake Business Park,
Milton Keynes MK7 8LE
Great Britain
Hirose Electric Co., Ltd.
5-23, Osaki 5 Chome,
Shinagawa-Ku
Tokyo 141
Japan
Hirose Electric Europe B.V.
Hogehillweg 8
1101 CC Amsterdam Z-O
Netherlands
Phone: +44-1908-369060
Fax: +44-1908-369078
Phone: +81-03-3491-9741
Fax: +81-03-3493-2933
Phone: +31-20-6557-460
Fax: +31-20-6557-469

PLS8-USR4_HIO_v03.915
Confidential / Preliminary
2017-03-27
44
About Gemalto
Gemalto (Euronext NL0000400653 GTO) is the world leader in digital security with 2015 annual
revenues of €3.1 billion and blue-chip customers in over 180 countries. Our 14,000+ employees
operate out of 118 offices, 45 personalization and data centers, and 27 research and software
development centers located in 49 countries.
Gemalto develops secure embedded software and secure products which we design and
personalize. Our platforms and services manage these secure products, the confidential data they
contain and the trusted end-user services they enable. Our innovations enable our clients to offer
trusted and convenient digital services to billions of individuals.
Gemalto thrives with the growing number of people using its solutions to interact with the digital
and wireless world.
For more information please visit
m2m.gemalto.com, www.facebook.com/gemalto, or Follow@gemaltom2m on twitter.
Gemalto M2M GmbH
Werinherstrasse 81
81541 Munich
Germany
 M2M.GEMALTO.COM
© Gemalto 2017. All rights reserved. Gemalto, the Gemalto logo, are trademarks and service marks of Gemalto and are registered in certain countries. April 2013
We are at the heart of the rapidly evolving digital society. Billions of people worldwide increasingly
want the freedom to communicate, travel, shop, bank, entertain and work - anytime, everywhere
- in ways that are enjoyable and safe. Gemalto delivers on their expanding needs for personal
mobile services, payment security, authenticated cloud access, identity and privacy protection,
eHealthcare and eGovernment efficiency, convenient ticketing and dependable machine-tomachine (M2M) applications.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : chinrich
Create Date                     : 2017:03:27 16:14:41Z
Modify Date                     : 2017:03:27 16:31:30+02:00
Language                        : en
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.150055, 2012/11/19-18:45:32
Format                          : application/pdf
Creator                         : chinrich
Title                           : hid_pls8-us.book
Creator Tool                    : FrameMaker 2015.0.5
Metadata Date                   : 2017:03:27 16:31:30+02:00
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:90cc4f60-a67e-40e9-8510-71af82632ab1
Instance ID                     : uuid:efe65aa8-c589-49c1-9dd6-80ffb609d3a6
Page Mode                       : UseOutlines
Page Count                      : 44
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QIPPLS8-USR4

Navigation menu