TP Link Technologies CPE220 2.4GHz 300Mbps 12dBi Outdoor CPE User Manual CPE220 Rev6
TP-Link Technologies Co., Ltd. 2.4GHz 300Mbps 12dBi Outdoor CPE CPE220 Rev6
CPE220-User Manual Rev6
Installation Guide Outdoor CPE CPE210 / CPE220 / CPE510 / CPE520 CONTENTS Overview Hardware Connection Site Consideration Ethernet Cable Selection Connection and Installation Lightning & ESD Protection Software Configuration Login to Pharos Antenna Alignment 11 Specifications 12 Frequently Asked Questions (FAQ) 13 Overview TP-LINK's Pharos series outdoor CPEs are dedicated to remote pointto-point connection. This guide is applicable to products including CPE210, CPE220, CPE510 and CPE520. • Package Contents Installation Guide Power Cord Outdoor CPE CPE210 / CPE220 / CPE510 / CPE520 Pharos CPE Passive PoE Adapter Pole Mounting Straps Installation Guide TERMS OF USE: TP-LINK's Pharos series outdoor CPEs must be professionally installed. Shielded Ethernet cable and earth grounding must be used as conditions of product warranty. TOUGHCable is designed for outdoor installations. It is the customer’s responsibility to follow local country regulations, including operation within legal frequency channels, output power, and Dynamic Frequency Selection (DFS) requirements. • Panel Layout Pharos CPE: Grouding Terminal Shielded Ethernet Port LAN0 (Passive PoE in) Shielded Ethernet Port LAN1 Passive PoE Adapter: Power LED The Power LED indicates the electricity current situation: green (0~0.8A), red (0.8A~1A). Remote POE Reset LAN RESET Hardware Connection 1. Site Consideration • Mounting Height Ensure a clear line of sight between the wireless devices for an optimum performance. An elevated location is recommended as obstacles like trees, buildings and large steel structures will weaken the wireless signal. See Q2 in FAQ for details about how to calculate the minimum mounting height of the devices. line of sight Side View • Orientation Install the CPE devices with their fronts facing the signal receivers. You can orient the devices with the assistance of Google Map, GPS and some landmarks according to the horizontal beamwidth listed below. Models CPE210 CPE220 CPE510 CPE520 Horizontal Beamwidth 65° 45° 45° 50° shenzhen Be oriz am on w tal id th lin of sig ht 2. Ethernet Cable Preparation 1. Select the adequate type of Ethernet cable. The shielded CAT5e cable with ground wire (refer to the figure below) is prior to the general shielded CAT5e cable during the whole cabling. The former can more effectively protect your devices against ESD attacks under brutal outdoor environment. Sheath Twisted Pair Ground Wire Cable Shield Secondary Cable Shield Shielded RJ45 Connector Shielded CAT5e Cable with Ground Wire 2. Review the routes of connecting the POE Adapter to the CPE and evaluate the Ethernet cable length for all the connections, then prepare adequate Ethernet cable. 3. Connection and Installation 5734 MADE IN CHINA 5GHz 300Mbps 13dBi Outdoor CPE Power: 24V 1A Model: CPE510 Default Settings: IP: 192.168.0.254 Username: admin Password: admin This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference,and (2) this device must accept any interference received, including interference that may cause undesired operation. IC:8853A-CPE510 FCC ID:TE7CPE510 Please connect and install the device as shown in the figure below. The product is suitable for indoor installation. Connect the PoE Adapter to a power outlet with the power cord. Power over Ethernet up to 60m Connect the LAN0 (POE IN) port of the CPE to the PoE port of the PoE Adapter. Slide to replace the cover of the CPE when all connections are finished. At the selected site, approximately align the CPE to the direction that you have oriented. Fasten the CPE with the provided Pole Mounting Straps to a pole or mounting bracket. Connect the LAN port of the PoE Adapter to a computer, router or switch. 4. Lightning & ESD Protection Proper grounding is extremely important for outdoor devices. Pharos CPEs provide two methods to protect the devices from damage of lightning and ESD attacks as shown in the figure below. Two Methods: CPE 1 Shielded CAT5e Cable with Ground Wire & PoE Adapter with Earth Ground 2 Grounding Terminal and Cable Grounding Terminal Grounding Cable Shielded CAT5e Cable with Ground Wire PoE Adapter with Earth Ground Earth Ground In most cases, adopting either of the two methods can be adequate, but adopting both of them can offer more effective protection. Software Configuration This chapter introduces the login to the Pharos Web Interface and the software configurations to implement Point-to-Point application. 1. Login to PharOS 1. Before accessing the PharOS Web Interface, you need to assign a static IP address 192.168.0.x (2≤x≤253) to your computer. We use 192.168.0.10 as an example in the figure below. 2. Open your web browser, type 'http://192.168.0.254' in the address field and press 'Enter'. It is recommended to use the latest version of Google Chrome, Safari or Firefox. 3. The 'Login' page will appear, set the parameters as below. • Username: admin • Password: admin • Region: select according to your country/region • Select 'I agree to these terms of use' • Click 'Login' 4. At the first login, change the 'Password' for safety. For subsequent logins, you only need to enter the username and password that you have set to log in. 5. Then you will log in to the PharOS Web Interface and see the Status page, shown as the figure below. 10 Antenna Alignment In order to get the best performance, you can precisely align the direction of the CPE with the assistance of 'Wireless Signal Quality' on STATUS page of the Pharos Web Interface. WISP Adjust the direction of the CPE until the device reaches the highest SNR 18dB 22dB 24dB 22dB 18dB 11 Specifications HARDWARE FEATURES Dimensions Interface CPE520/CPE220: 275.83*79*60.3mm CPE510/CPE210: 224.34*79*60.3mm LAN0: 10/100Mbps Ethernet Port(PoE IN) LAN1: 10/100Mbps Ethernet Port GND: Grounding Terminal for Lightning Protection RESET: Button to restore the device to Factory Default Power Supply 24V Passive PoE Adapter Included ESD Protection1) 15kV Lightning Protection1) 6kV Operating Temperature -30℃ ~60℃ (-22℃ ~158℃ ) Operating Humidity 5% ~ 95 % Certification CE, FCC, RoHS, IPX5 WIRELESS FEATURES Models CPE210 CPE220 CPE510 CPE520 Antenna Gain 9dBi 12dBi 13dBi 16dBi Horizontal Beamwidth/ Elevation Beamwidth2) 65°/ 45° 45°/ 30° 45°/ 33° 50°/ 20° Maximum Transmit Power3) 27dBm 30dBma 27dBm 30dBm Operating Frequency 2.42.4835GHz 2.42.4835GHz 5.155.85GHz 5.155.85GHz 802.11 Standards 11b/g/n 11b/g/n 11a/n 11a/n Note 1) Estimation is based on copper grounding cable and shielded CAT5e cable with ESD drain wire. 2) Beamwidth values may vary throughout operating frequency. 3) Maximum transmit power and operating frequency may vary in different countries or regions. 12 Frequently Asked Questions (FAQ) Q1. How to restore the CPE to its factory default settings? With the CPE powered on, press and hold the 'RESET' button of the CPE or the 'Remote Reset' button of the Passive PoE Adapter for about 8 seconds until the Wireless Signal Strength LEDs flash. Pharos CPE: RESET Passive PoE Adapter: Remote Reset 13 Q2. How to calculate the minimum mounting height of the devices? In order to maximize the received signal strength of the devices, installers need to minimize the effect of the out-of-phase signals, which is caused by obstacles in the path between the transmitter and the receiver. Fresnel Zone is a usual method to calculate this path, as shown in the formula and the figure below. d2 d1 h = the height of obstacle at this point H h+r*(1 40%) (H is the height of the CPE) r= d1 × d 2 c ⋅ d1 + d 2 f where, r = Fresnel zone radius in meters c = 3x108 m/s, speed of light f = operating frequency of the devices in Hz d1 & d2 = the distances between the point and the devices in meters For example, assume d1 is 2km, d2 is 8km, and f is 2.4GHz, then r would be 14.142m. Considering a toleration of 40%, allowable radius would be 8.485m. Assume h is 10m, then the result of the minimum mounting height based on this point would be 18.485m. Similarly, calculate the results based on all the points where there are obstacles, and the maximum value would be the final result. For more information, please refer to http://en.wikipedia.org/wiki/Fresnel_zone 14 Q3. How can I use Spectrum Analysis to find the appropriate channel for the devices? 1. Log in to PharOS, on the 'WIRELESS' page, you can find the 'Spectrum Analysis' button as shown in the figure below. Click the button. 2. The following window will pop up. Click 'Yes' and you will then get into the Spectrum Analysis page. 3. Select the 'Frequency Range' and click the 'Start' button, the PharOS will begin to analyze the power of the frequency. Watch the curves for a period of time, and then click 'Stop'. Mark the relatively low and continuous part of the average curve, and note the corresponding frequency range. Here we take the figure below as an example. 15 4. Close the Spectrum Analysis Window, and then you will get back to the Wireless page. For the Channel/Frequency option, it is recommended to select a value whose frequency is within the noted frequency range. So, in this example, the recommended Channel/Frequency is 116/5580MHz. 16 FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. To comply with FCC RF exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.” CE Mark Warning This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. IC STATEMENT This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам нормативних документів та вимогам, що передбачені чинними законодавчими актами України. 17 Safety Information • When product has power button, the power button is one of the way to shut off the product; When there is no power button, the only way to completely shut off power is to disconnect the product or the power adapter from the power source. • Don’t disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the limited warranty. If you need service, please contact us. • Avoid water and wet locations. 注意! 依據 低功率電波輻射性電機管理辦法 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自 變更頻率、加大功率或變更原設計之特性或功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通行;經發現有干擾現象時, 應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信規定作業之無線電信。 低功率射頻電機需忍受合法通信或工業、科學以及醫療用電波輻射性電機設備之干擾 。 減少電磁波影響,請妥適使用。 於 5.25GHz 至 5.35GHz 區域內操作之無線設備的警告聲明 工作頻率 5.250~5.350GHz 該頻段限於室內使用。 安全諮詢及注意事項 ●請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。 ●清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。 ●注意防潮,請勿將水或其他液體潑灑到本產品上。 ●插槽與開口供通風使用,以確保本產品的操作可靠並防止過熱,請勿堵塞或覆蓋開口。 ●請勿將本產品置放於靠近熱源的地方。除非有正常的通風,否則不可放在密閉位置中。 ●請不要私自打開機殼,不要嘗試自行維修本產品,請由授權的專業人士進行此項工作。 此為甲類資訊技術設備,于居住環境中使用時,可能會造成射頻擾動,在此種情況下,使用 者會被要求採取某些適當的對策。 This product can be used in the following countries: AT / BG / BY / CA / CZ / DE / DK / EE / ES / FI / FR / GB / GR / HU / IE / IT LT / LV / MT / NL / NO / PL / PT / RO / RU / SE / SK / TR / UA 18 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright © 2014 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved. Website: http://www.tp-link.com Tel: +86 755 26504400 E-mail: support@tp-link.com 7106504648 REV1.0.0 19
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2015:03:27 15:52:44+08:00 Creator : Adobe InDesign CC (Windows) Modify Date : 2015:04:23 09:19:46+08:00 Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2015:04:23 09:19:46+08:00 Creator Tool : Adobe InDesign CC (Windows) Instance ID : uuid:aca43769-de5b-4db8-a066-6f8444a0fe31 Original Document ID : xmp.did:A4B61609949AE311863EA088DDCCFADC Document ID : xmp.id:b3243f96-d560-0b40-8334-84d8638b9662 Rendition Class : proof:pdf History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Windows) History Changed : / History When : 2015:03:27 15:52:44+08:00 Derived From Instance ID : xmp.iid:715db9db-8bde-f841-a4a5-5abf4fbb0f62 Derived From Document ID : xmp.did:A4B61609949AE311863EA088DDCCFADC Derived From Original Document ID: xmp.did:A4B61609949AE311863EA088DDCCFADC Derived From Rendition Class : default Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 21EXIF Metadata provided by EXIF.tools