TP Link Technologies CPE610 5GHz 300Mbps 23dBi Outdoor CPE User Manual TE7CPE610

TP-Link Technologies Co., Ltd. 5GHz 300Mbps 23dBi Outdoor CPE TE7CPE610

User Manual

Download: TP Link Technologies CPE610 5GHz 300Mbps 23dBi Outdoor CPE User Manual TE7CPE610
Mirror Download [FCC.gov]TP Link Technologies CPE610 5GHz 300Mbps 23dBi Outdoor CPE User Manual TE7CPE610
Document ID3548567
Application ID13xr2xFtsboGhvilEhwpqQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize220.25kB (2753178 bits)
Date Submitted2017-09-07 00:00:00
Date Available2017-09-08 00:00:00
Creation Date2017-09-01 09:56:54
Producing SoftwareAcrobat Distiller 15.0 (Windows)
Document Lastmod2017-09-01 09:57:55
Document TitleTE7CPE610_User Manual.pdf
Document CreatorAdobe Illustrator CC 2015 (Windows)
Document Author: SharonJiang

Installation Guide
Outdoor CPE
CPE610
Contents
Overview
Package Contents
Hardware Overview
Hardware Connection
Site Consideration
Hardware Installation
Power Supply
Lightning & ESD Protection
Software Configuration
15
Logging in to the PharOS
Configuration for a Typical Application
Antenna Alignment
18
Specifications
19
FAQ
20
Overview
TP-Link's Pharos series outdoor CPEs are dedicated to outdoor
wireless network solutions. This guide is applicable to the product
CPE610.
Package Contents
Pharos CPE
Center Reflector Panel
Side Reflector Panels
(Qty.2)
Rear Cover
Mounting Bracket
(For CPE)
Protective Cap
Bolts with Nut and Lock
Washer Assemblies
(M6×110, Qty.2)
Bolts with Nut and Lock
Washer Assemblies
(M6×70)
Pole-mount Clamp
Installation Guide
Outdoor CPE
Power Cord
Passive PoE Adapter
CPE610
Installation Guide
Mounting Bracket
(For PoE Adapter)
ST3×10 Self-tapping Screws
(Qty.2)
D3×28 Plastic Wall Anchors
(Qty.2)
Hardware Overview
Bottom View
Reflector Assembly
Securing Arms
Bubble Level
Rear Cover
Mounting Bracket
Pole-mount Clamp
Panel Layout
On: The wireless function is enabled.
On: A device is connected to this port, but there
is no activity.
Flashing: A device is connected to this port, and
is active.
On: The CPE is powered on.
RESET
Press and hold for 5 seconds to reset the CPE to
its factory defaults.
ETHERNET
The port is to connect to the POE port of the
provided PoE adapter for both data transmission
and power supply through Ethernet cabling.
Passive PoE Adapter
Remote Reset
Press and hold for 5 seconds to reset the CPE
to its factory defaults.
Power LED
On: Power on.
Off: Power off.
Hardware Connection
Site Consideration
Mounting Height
Ensure a clear line of sight between the wireless devices for
optimum performance. An elevated location is recommended as
obstacles like trees, buildings and large steel structures will
weaken the wireless signal. See 'Q2' in 'FAQ' for details about
how to calculate the minimum mounting height of the devices.
Line of Sight
Side View
Orientation
Install the CPE devices so that they point towards the devices
that will receive the signal. You can orient the devices with the
help of Google Maps, GPS and some landmarks. The horizontal
bandwidth of CPE610 is 6.8°.
shenzhen
Be ori
am zo
w nta
id l
th
Lin
of
Si
gh
Hardware Installation
1. Attach the Side Reflector Panels to the Center Reflector Panel
as follows:
a. Insert the two mounting studs on the Center Reflector
Panel into the large opening of the slots on the Side
Reflector Panel.
b. Slide the Side Reflector Panel until the mounting studs are
positioned over the narrow opening of the slots, and the top
edges of the panels should be aligned when done.
c. Repeat step a and step b to attach the other Side Reflector
Panel.
d. (Optional) Attach the Side Reflector Panels to the Center
Reflector Panel more securely using four M2.5x8 bolts and
nuts (not provided). This is recommended if the CPE device
is exposed to extreme weather, such as strong winds.
2. Attach the Rear Cover to the reflector assembly as follows:
a. While holding the reflector assembly, align the raised edges
on the back with the Securing Arms of the Rear Cover, and
align the Snap Hooks on the Rear Cover with the slots on
the Center Reflector Panel.
b. Attach the Rear Cover to the reflector assembly. Press upon
the Rear Cover at the four positions marked in the diagram
below in sequence until it locks into place.
WARNING: To avoid damage, do not place the panels on a flat
surface or push down on it.
3. Insert the Pharos CPE into the Rear Cover until the CPE locks
into place.
4. Connect the Ethernet cable to the Pharos CPE.
a. Connect the Ethernet cable to the Ethernet port.
Note: The length of the Ethernet cable is up to 60m for steady
power supply.
b. Attach the Protective Cap to the Rear Cover.
5. Attach the Mounting Bracket to the Rear Cover until the
grooves on the Mounting Bracket are positioned over the pins
on the Rear Cover.
10
6. Secure the Mounting Bracket to the Rear Cover using M6x70
Bolts with Nut and Lock Washer Assemblies.
7. Attach the CPE assembly to the pole using two Pole-mount
Clamps and two M6x110 Bolts with Nut and Lock Washer
Assemblies.
a. Insert the two Bolts into the Mounting Bracket.
11
b. Secure the Pole-mount Clamps with Nuts and Washers.
Note: Suitable pole diameters range from 15mm to 70mm.
8. Adjust the azimuth and elevation angle of the CPE device to
achieve maximum signal strength.
12
Power Supply
Connecting the PoE Adapter
Connect the devices as shown in the figure below.
PoE
LAN
Ethernet cable
length up to 60m
Mounting the PoE Adapter (Optional)
Note: To ensure the passive PoE adapter is attached most securely, it is
recommended to install the adapter with the Ethernet port facing upward.
1. Drill two holes on the wall
2. Attach the passive PoE
and insert the plastic wall
adapter to the mounting
anchors into the the holes.
bracket by sliding the adapter
Secure the mounting bracket in the direction of the arrows
to the wall.
until it locks into place.
13
Lightning & ESD Protection
Proper grounding is extremely important for outdoor devices.
By using shielded CAT5e (or above) cable with ground wire and
the provided PoE adapter, you can effectively eliminate ESD
attacks.
CPE
Grounded 3-wire
Power Outlet
Shielded CAT5e (or above)
Cable with Ground Wire
PoE Adapter with
Earth Ground
Sheath
Twisted Pair
Ground Wire
Cable Shield
Secondary Cable Shield
14
6RIWZDUH&RQĆŽJXUDWLRQ
This chapter introduces the login to the PharOS Web Interface
and the software configurations.
Logging in to the PharOS
1. Before accessing the PharOS Web Interface, you need to
assign a static IP address 192.168.0.X (X ranges between 2
and 253, e.g. 192.168.0.10) to your computer.
2. Open a web browser, type http://192.168.0.254 into the
address field and press Enter (Windows) or return (Mac). It is
recommended to use the latest version of Google Chrome,
Firefox or Safari.
192.168.0.254
3. Enter admin for both User Name and Password, then select
the Language from the drop-down list. Read and agree to the
terms of use, then click Login.
15
4. Change the default User Name and Password for security
purposes. You can then start to configure your CPE.
For subsequent logins, use the new username and password.
For more configurations, please visit
http://www.tp-link.com/support to download the User Guide of
PharOS products in the download center.
&RQĆŽJXUDWLRQIRUD7\SLFDO$SSOLFDWLRQ
The typical topology is as follows: Multiple wireless bridges are
built among the access point and the clients. Follow the
instructions below to configure the Access Point and the Client.
For simplicity, we will take one wireless bridge as an example.
Access Point
Client
Client
Client
&RQĆŽJXUHWKH$FFHVV3RLQW $3
1.
2.
3.
4.
Log in to PharOS and go to the Quick Setup page.
Operation Mode: Select Access Point and click Next.
LAN Settings: Click Next.
Wireless AP Settings:
a. Create a new SSID (Network name) for your wireless
network.
b. Select WPA-PSK/WPA2-PSK for the Security method and
create a PSK Password to protect your AP.
16
c. Enter the distance between the Access Point and the
Client into the Distance Setting field.
d. Select the MAXtream checkbox (Refer to Q3 in FAQ for
details about MAXtream), and click Next.
5. Finish: Verify your settings and click Finish to complete the
configuration.
&RQĆŽJXUHWKH&OLHQW
1. Log in to PharOS and go to the Quick Setup page.
2. Operation Mode: Select Client and click Next.
3. LAN Settings: Change the IP Address to 192.168.0.X (X
ranges between 2 and 253), the same subnet as the access
point, and click Next.
4. Wireless Client Settings:
a. Click Survey and select the SSID of the Access Point in
the AP list, then click Connect.
b. Select WPA-PSK/WPA2-PSK from the Security option,
enter the same PSK password and distance value of the
Access Point, then click Next.
5. Finish: Verify your settings and click Finish to complete the
configuration.
For more configurations, please visit
http://www.tp-link.com/support to download the User Guide of
PharOS products in the download center.
17
$QWHQQD$OLJQPHQW
In order to get the best performance, you can precisely align the
direction of the CPE with the assistance of Wireless Signal
Quality on the STATUS page of the PharOS Web Interface.
Adjust the direction of the CPE until the
SNR reaches a maximum.
WBS+Antenna
WBS+Antenna
18
6SHFLĆŽFDWLRQV
HARDWARE FEATURES
Interface
LAN: 10/100Mbps Ethernet port
RESET: Button to restore the device to its
factory defaults
Power Supply
24V passive PoE adapter included
ESD Protection 1
15kV
Lightning Protection 1
Up to 6kV
Operating Temperature
-40℃ to 70℃ (-40℉
to 158℉)
Operating Humidity
10% to 90%
&HUWLĆŽFDWLRQ
CE, FCC, RoHS, IP65
WIRELESS FEATURES
Antenna Gain
20.8dBi
Vertical-Polarization
Port
Azimuth Beamwidth: 8.9°
Elevation Beamwidth: 7.1°
Horizontal-Polarization
Port
Azimuth Beamwidth: 8.0°
Elevation Beamwidth: 6.8°
802.11 Standards
11a/n
Note:
1. Estimation is based on shielded CAT5e(or above) cable with an
integrated grounding wire.
19
)$4
Q1. How to restore the CPE to its factory default settings?
With the CPE powered on, press and hold the RESET
button on the CPE or the Remote Reset button on the
passive PoE adapter for about 5 seconds.
Method 1:
RESET Button:
Press & hold for about 5 seconds
Method 2:
Remote Reset Button:
Press & hold for about 5 seconds
20
Q2. How to calculate the minimum mounting height
of the devices?
In order to maximize the received signal strength of the
devices, you need to minimize the effect of the
out-of-phase signals, which is caused by obstacles in the
path between the transmitter and the receiver. Fresnel
Zone is a usual method to calculate this path, as shown in
the formula and the figure below.
d2
d1
h = the height of
obstacle at this point
H h+r*(1 40%)
(H is the height of the CPE)
where,
d1 u d 2 c
˜
d1  d 2 f
r = Fresnel zone radius in meters
c = 3x108 m/s, speed of light
f = operating frequency of the
devices in Hz
d1 & d2 = the distances between the
point and the devices in meters
For example, assume d1 is 2km, d2 is 8km, and f is 2.4GHz,
then r would be 14.142m. Considering a toleration of 40%,
allowable radius would be 8.485m. Assume h is 10m, then
the result of the minimum mounting height based on this
point would be 18.485m. Similarly, calculate the results
based on all the points where there are obstacles, and the
maximum value would be the final result.
For more information, please refer to:
http://en.wikipedia.org/wiki/Fresnel_zone
21
Q3. What is Pharos MAXtream?
Pharos MAXtream is a proprietary protocol developed on
the basis of Time Division Multiple Access (TDMA) by
TP-Link.
The MAXtream technology has the following advantages:
Eliminates hidden node collisions & improves channel
efficiency.
Lower latency, higher throughput, larger network
capacity & more stability.
Improves the QoS for video, voice and sound data
stream.
By dividing the timing of transmission into different time
slots, MAXtream allows the Pharos devices to transmit in
rapid succession, one after another, each stream using its
own time slot to transmit and receive frames, which greatly
reduces the chance of collision.
Pharos MAXtream is a non-standard Wi-Fi protocol that is
only compatible with TP-Link’s Pharos series products.
Please note that you will not be able to connect other Wi-Fi
devices to an AP with MAXtream enabled.
Q4. How can I use Spectrum Analysis to find the
appropriate channel for the devices?
1. Log in to PharOS, click Spectrum Analysis in the tools
drop-down list, a window will pop up to remind you that all
wireless connections will be lost during spectrum analysis.
Click Yes to continue to the Spectrum Analysis page.
22
2. Click Start, PharOS will begin to analyze the power of
frequency. Observe the curves for a period of time, and
then click Stop. Note that the relatively low and continuous
part of the average curve indicates less radio noise. Here,
we use the figure below as an example.
3. When choosing channel/frequency, you should avoid the
spectrum with large radio noise. In this example, the
recommended channel/ frequency is 112/5560MHz.
23
)&&67$7(0(17
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at
his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that
may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Note: The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment. Such modifications could void
the user’s authority to operate the equipment.
)&&5)5DGLDWLRQ([SRVXUH6WDWHPHQW
This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment. This device and its antenna must not be co-located or
operating in conjunction with any other antenna or transmitter.
“To comply with FCC RF exposure compliance requirements, this grant is
applicable to only Mobile Configurations. The antennas used for this transmitter
must be installed to provide a separation distance of at least 20 cm from all
persons and must not be co-located or operating in conjunction with any other
antenna or transmitter.”
CE 0ark Warning
5)([SRVXUH,QIRUPDWLRQ
This device meets the EU requirements (2014/53/EU Article 3.1a) on the limitation
of exposure of the general public to electromagnetic fields by way of health
protection.
This is a class A product. In a domestic environment, this product may cause radio
interference, in which case the user may be required to take adequate measures.
цѧѥћѪѡѩѨќѧѩџѫѽѡѥљїѤѥўњѽћѤѥѨѦѧїљџѢїѣџѨџѨѩќѣџъѡѧшмцчхѤїљѽћѦѥљѽћѤѽѨѩѳљџѣѥњїѣ
ѤѥѧѣїѩџљѤџѬћѥѡѪѣќѤѩѽљѩїљџѣѥњїѣѰѥѦќѧќћјїѮќѤѽѮџѤѤџѣџўїѡѥѤѥћїљѮџѣџїѡѩїѣџ
ъѡѧїѾѤџ
Safety InfRUPation
• Keep the device away from water, fire, humidity or hot environments.
• Do not attempt to disassemble, repair, or modify the device.
• Do not use damaged charger or USB cable to charge the device.
• Do not use any other chargers than those recommended.
• Do not use the device where wireless devices are not allowed.
• Adapter shall be installed near the equipment and shall be easily accessible.
Use only power supplies which are provided by manufacturer and in the
original packing of this product. If you have any questions, please don't hesitate to
contact us.
For EU/EFTA, this product can be used in the following countries:
AT / BE / BG / CH / CY / CZ / DE / DK / EE / EL / EF / FI / FR / HR / HU / IE / IS / IT / LI / LT /
LU / LV / MT / NL / NO / PL / PT / RO / SE / SI / SK / UK
([SODQDWLRQRIWKHV\PEROVRQWKHSURGXFWODEHO
Symbol
Explanation
DC voltage
RECYCLING
This product bears the selective sorting symbol for Waste
electrical and electronic equipment (WEEE). This means that
this product must be handled pursuant to European directive
2012/19/EU in order to be recycled or dismantled to minimize
its impact on the environment.
User has the choice to give his product to a competent
recycling organization or to the retailer when he buys a new
electrical or electronic equipment.
For technical support, User Guide and other information, please
visit http://www.tp-link.com/support, or simply scan the QR code.
The products of TP-Link partly contain software code developed by third parties, including
software code subject to the GNU General Public License (“GPL”). As applicable, the terms of the
GPL and any information on obtaining access to the respective GPL Code used in TP-Link
products are available to you in GPL-Code-Centre under (http://www.tp-link.com/en/support/gpl/).
The respective programs are distributed WITHOUT ANY WARRANTY and are subject to the
copyrights of one or more authors. For details, see the GPL Code and other terms of the GPL.
Š 2017 TP-Link
7106507710 REV1.0.0

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : SharonJiang
Create Date                     : 2017:09:01 09:56:54+08:00
Modify Date                     : 2017:09:01 09:57:55+08:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Format                          : application/pdf
Title                           : TE7CPE610_User Manual.pdf
Creator                         : SharonJiang
Rights                          : © 2012-2013 Ubiquiti Networks, Inc. All rights reserved.
Metadata Date                   : 2017:09:01 09:57:55+08:00
Creator Tool                    : Adobe Illustrator CC 2015 (Windows)
Thumbnail Width                 : 256
Thumbnail Height                : 212
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 3954 bytes, use -b option to extract)
Instance ID                     : uuid:2b9a914b-d71c-4473-992c-ec7c5d0d3e31
Original Document ID            : xmp.did:F77F11740720681180839ACE20804D07
Document ID                     : xmp.did:35136552-5a20-9d4d-9495-e4a12023ab05
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:d3b29a12-5528-4e5f-b1b3-4273c0b14e71
Derived From Document ID        : xmp.did:4e5218a5-feb5-42bb-b42f-a7e80ba4b5a7
Derived From Original Document ID: xmp.did:F77F11740720681180839ACE20804D07
Derived From Rendition Class    : proof:pdf
History Action                  : converted, saved, saved
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh), Adobe Illustrator CC (Windows), Adobe Illustrator CC 2015 (Windows)
History Changed                 : /, /, /
History When                    : 2013:06:05 16:34-07:00, 2015:02:04 15:45:16+08:00, 2017:08:29 14:31:32+08:00
History Instance ID             : xmp.iid:2f95ba9a-b6ca-0b44-b57e-0be431c93c02, xmp.iid:35136552-5a20-9d4d-9495-e4a12023ab05
Manifest Link Form              : EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference
Manifest Reference File Path    : \\file.tp-link.net\RD文档\规范及模板\说明书制作流程\4. 说明书编写规范\说明书认证警语规范\认证图标\垃圾桶.png, \\file.tp-link.net\RD文档\规范及模板\说明书制作流程\4. 说明书编写规范\说明书认证警语规范\认证图标\二.png, E:\a~任务\说明书\BS210\参考IG\张珊提供\网址图.png, E:\a~任务\说明书\BS210\参考IG\张珊提供\IP地址图.png, F:\工作\3.项目\CPE610(UN) 1.0\文件\IG\截图\截图.png, F:\工作\3.项目\二维码.png, E:\a~任务\说明书\BS210\参考IG\beijing\fengmian_6-2.png
Manifest Reference Document ID  : 0, 0
Manifest Reference Instance ID  : 0, 0
Ingredients File Path           : \\file.tp-link.net\RD文档\规范及模板\说明书制作流程\4. 说明书编写规范\说明书认证警语规范\认证图标\垃圾桶.png, \\file.tp-link.net\RD文档\规范及模板\说明书制作流程\4. 说明书编写规范\说明书认证警语规范\认证图标\二.png, E:\a~任务\说明书\BS210\参考IG\张珊提供\网址图.png, E:\a~任务\说明书\BS210\参考IG\张珊提供\IP地址图.png, F:\工作\3.项目\CPE610(UN) 1.0\文件\IG\截图\截图.png, F:\工作\3.项目\二维码.png, E:\a~任务\说明书\BS210\参考IG\beijing\fengmian_6-2.png
Ingredients Document ID         : 0, 0
Ingredients Instance ID         : 0, 0
Producer                        : Acrobat Distiller 15.0 (Windows)
Trapped                         : False
N Pages                         : 1
Has Visible Transparency        : True
Has Visible Overprint           : True
Max Page Size W                 : 110.000000
Max Page Size H                 : 170.000000
Max Page Size Unit              : Millimeters
Font Name                       : ArialMT, MyriadPro-Regular, SymbolMT, TimesNewRomanPSMT, TimesNewRomanPS-ItalicMT, TP-LinkAktiv-Light, TP-LinkAktiv-Regular, TP-LinkAktiv-Medium, STKaiti, AdobeSongStd-Light
Font Family                     : Arial, Myriad Pro, Symbol, Times New Roman, Times New Roman, TP-Link Aktiv, TP-Link Aktiv, TP-Link Aktiv, 华文楷体, Adobe 宋体 Std
Font Face                       : Regular, Regular, Regular, Regular, Italic, Light, Regular, Medium, Regular, L
Font Type                       : Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type
Font Version                    : Version 5.06, Version 2.106;PS 2.000;hotconv 1.0.70;makeotf.lib2.5.58329, Version 5.00, Version 5.07, Version 5.07, Version 1.000, Version 1.000, Version 1.000, Version 1.02, Version 5.017;PS 5.002;hotconv 1.0.67;makeotf.lib2.5.33168
Font Composite                  : False, False, False, False, False, False, False, False, False, False
Font File Name                  : arial.ttf, MyriadPro-Regular.otf, symbol.ttf, times.ttf, timesi.ttf, TP-LinkAktiv_Lt.ttf, TP-LinkAktiv_Rg.ttf, TP-LinkAktiv_Md.ttf, STKAITI.TTF, AdobeSongStd-Light.otf
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Groups Group Name        : 默认色板组
Swatch Groups Group Type        : 0
Swatch Groups Colorants L       : 69.019608
Swatch Groups Colorants A       : 0
Swatch Groups Colorants B       : -1
Swatch Groups Colorants Swatch Name: outline
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Tint    : 100.000000
Swatch Groups Colorants Mode    : CMYK
Swatch Groups Colorants Cyan    : 0.000000
Swatch Groups Colorants Magenta : 0.000000
Swatch Groups Colorants Yellow  : 0.000000
Swatch Groups Colorants Black   : 80.000001
Page Count                      : 28
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TE7CPE610

Navigation menu