11 March 1998 FCC ID: BBD3—1BE—S APPENDIX B OPERATlNG/SERVICE/INSTRUCTION MANUAL E1 GENERAL SPECIFICATIONS FREQUENCY RANGE: 400 — 512 MHZ BANDWIDTH: 1 7 MHz OPERRTING MODE : FM POWER POWER NOMINAL FUSE MODEL INPUT OUTPUT CURRENT DRAIN PAS-IAC 1-4W 25-50W 8 AMPS 15 AMPS PAG—lAC-Z 3-6W 25—50“ B AMPS 15 AMPS PA6—1AE 1—4W 70-100W 20 AMPS 25 AMPS PAS—lAE-2 3-6W 70—100“ 20 AMPS 25 AMPS FAG—13C ' 8—15W 25-50“ 7 AMPS 10 AMPS PAG—lBE S-lSW 70—100W 16 AMPS 20 AMPS PAS—IFE 20-40W 70—100W 15 AMPS 20 AMPS PAG—lBEE 10W 200“ PAS—IAEE SW 250W,280MHZ NOTE: 100 WATTS MINIMUM OUTPUT AVAILABLE IF SPECIFIED OPERATING TEMPERATURE RANGE: -30' to +50' Celsius OPERATING VOLTAGE: Minimum 11 VDC, maximum 14 VDC, as measured at the DC input connector. Rated voltage is 13.8 Volts and all specifications are given at 13.8 Volts. Reduced Dc voltage will result in a decrease in power output and efficiency. BIA DUTY CYCLE: 100% RECEIVER INSERTION L055: 1 dB maximum (400-512 MHz), when optional receive relay is specified. HARMONIC'ATTENUATION: All harmonics —56dB minimum at 20 watts rising to -67dB minimum at 250 watts. CONNECTORS: TYPE N Female on RF input and output. DC input is a two terminal barrier strip unless unit is supplied with Ac power supply.