TRIXELL PN7120 NFC Module User Manual Module rev

TRIXELL NFC Module Module rev

User Manual_Module rev.pdf

    PN7120 NFC controller      User Manual
1. Introduction     2. Architecture
  3. Contactless Interface Unit   4. Reader/Writer communication modes
  Overview for ISO/IEC 14443A/MIFARE and Jewel/Topaz PCD Reader/Writer communication mode    Overview for Felicia Reader/Writer communication mode
 Overview for ISO/IEC 14443B Reader/Writer communication mode   Overview for ISO/IEC 15693 VCD Reader/Writer communication mode    Passive communication mode
4. Applications  All devices requiring NFC functionality especially those running in an Android or Linux  environment  TVs, set-top boxes, Blu-ray decoders, audio devices  Home automation, gateways, wireless routers  Home appliances  Wearables, remote controls, healthcare, fitness  Printers, IP phones, gaming consoles, accessories   5. Quick reference
 Frequency : 13.56 MHz Host interface: I²C bus
6. Information for FCC and IC  Federal Communication Commission Interference Statement  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device,  pursuant  to  Part  15  of  the  FCC  Rules.    These  limits  are  designed  to  provide reasonable  protection  against  harmful  interference  in  a  residential  installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the  instructions,  may cause harmful interference to radio communications.    However, there is no guarantee that interference will not occur in a particular  installation.    If  this  equipment  does  cause  harmful  interference  to  radio  or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  -  Reorient or relocate the receiving antenna. -  Increase the separation between the equipment and receiver. -  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -  Consult the dealer or an experienced radio/TV technician for help.  FCC  Caution:  Any  changes  or  modifications  not  expressly  approved  by  the  party responsible for compliance could void the user's authority to operate this equipment.  This  transmitter  must  not  be  co-located  or  operating  in  conjunction  with  any  other antenna or transmitter.
This device is intended only for OEM integrators under the following conditions:  1) The transmitter module may not be co-located with any other transmitter or antenna.   2) Module approval valid only when the module is installed in the tested host or compatible series of host which have similar RF exposure characteristic with equal or larger antenna separation distance.  As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed  IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization.  End Product Labeling   The final end product must be labeled in a visible area with the following: “Contains FCC ID: VPQ-PN7120”. The grantee's FCC ID can be used only when all FCC compliance requirements are met.  Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.
Industry Canada statement: This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable.   This device is intended only for OEM integrators under the following conditions: (For module device use) 1) The transmitter module may not be co-located with any other transmitter or antenna. 2) Module approval valid only  when  the  module is installed in  the  tested host or  compatible series  of  host  which  have  similar  RF  exposure  characteristic  with  equal  or  larger  antenna separation distance.  As long  as 2 conditions above are met, further transmitter test will not be required. However, the  OEM  integrator  is  still  responsible  for  testing  their  end-product  for  any  additional compliance requirements required with this module installed.  Cet appareil est conçu uniquement pour les intégrateurs OEM dans les conditions suivantes: (Pour utilisation de dispositif module) 1) Le module émetteur peut ne pas être coïmplanté avec un autre émetteur ou antenne. 2) Approbation du Module valable que lorsque le module est installé dans l'hôte testé ou de la série  de  l'hôte  compatible  qui  ont  même  caractéristique  de  l'exposition  aux  RF  avec  la distance égale ou supérieure séparation antenne. Tant que les 2 conditions ci-dessus sont remplies, des essais supplémentaires sur l'émetteur ne seront pas nécessaires. Toutefois, l'intégrateur OEM est toujours responsable des essais sur son produit  final  pour  toutes  exigences  de  conformité  supplémentaires  requis  pour  ce  module installé.  IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location  with  another  transmitter),  then  the  Canada  authorization  is  no  longer  considered valid  and  the  IC  ID  can  not  be  used  on  the  final  product.  In  these  circumstances,  the  OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate Canada authorization.
NOTE IMPORTANTE: Dans le cas où ces conditions ne peuvent être satisfaites (par exemple pour certaines configurations d'ordinateur portable ou de certaines co-localisation avec un autre émetteur), l'autorisation du Canada n'est plus considéré comme valide et l'ID IC ne peut pas être utilisé sur le produit final. Dans ces circonstances, l'intégrateur OEM sera chargé de réévaluer le produit final (y compris l'émetteur) et l'obtention d'une autorisation distincte au Canada. End Product Labeling   The  final  end  product  must  be  labeled  in  a  visible  area  with  the  following:  “Contains  IC: 7392A-PN7120”.   Plaque signalétique du produit final Le produit final doit être étiqueté dans un endroit visible avec l'inscription suivante: "Contient des IC: 7392A-PN7120". Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. Manuel d'information à l'utilisateur final L'intégrateur  OEM  doit  être  conscient  de  ne  pas  fournir  des  informations  à  l'utilisateur  final quant  à  la  façon d'installer  ou  de  supprimer  ce  module  RF  dans  le  manuel  de  l'utilisateur  du produit final qui intègre ce module. Le  manuel  de  l'utilisateur  final  doit  inclure toutes  les  informations  réglementaires  requises  et avertissements comme indiqué  dans ce manuel.
7. Integration instruction For correct integration into an existing system, please follow the instructions: 1. Be sure to respect the connector pinouts as indicated hereafter:    Pin # Name Description 1 3V3 3.3 volts power supply 2 SCL I²C-bus serial clock input 3 SDA I²C-bus serial data 4 IRQ Interrupt request output 5 VEN Reset pin. Set the device in Hard Power Down 6 GND Ground (0V) Connector reference is BM06B-GHS-TBT. Please use a male connector compatible with this reference.  2. Respect power voltage. Do not apply voltage above 3.6 V 3. Verify that power supply can provide 170 mA.  The PN7120 modules are easily integrated into existing systems via I²C serial interfaces. Please contact sales for additional information.

Navigation menu