TSC Auto ID Technology 2009001 TSC-RFID User Manual

TSC Auto ID Technology Co., Ltd. TSC-RFID

user manual

                  TSC-RF013  Module  Protocol Manual                                    Version  1.01 2009.12.14
 TSC-RF013 Module Protocol  Manual    Contents  I、Descriptions................................................................................................2 Command Format ........................................................................................................................... 2 II、Function Summary..................................................................................3 Flags List .............................................................................................................................................. 3 Command List ................................................................................................................................... 3 Response Code List ......................................................................................................................... 3 III、Description of the Transmission.......................................................4 Select Tag ............................................................................................................................................ 4 Read Tag .............................................................................................................................................. 5 Write Tag ............................................................................................................................................. 6                                               - 1 -
  TSC-RF013 Module Protocol Manual  I、Descriptions    Mandatory Fields Optional Fields Command Format: Request: STX LENS FLAGS COMMAND DATA1 DATA2 ... DATAn CRC 0x02 8bits 8bits 8bits 8bits 8bits ... n*8bits 16bits    Response: STX LENS Response Code DATA1 DATA2 ... DATAn CRC 0x02 8bits 8bits 8bits 8bits ... n*8bits 16bits        STX is the ASCII code for a Start of Transmission. ( STX = 0x02 )       LENS specifies how many bytes are in the request or the response, not including the [STX] and not including the [LENS].       FLAGS specify command options.       COMMAND specifies the command type of the host request.       Response Code specifies the response message from the module.       DATA1, DATA2, ... , DATAn are optional for the command type data.       CRC is a two-byte field calculated by the host controller. The CRC is calculated over all the fields in the request or response not including the initiator and terminator bytes. The CRC polynomial, x16 + x12 + x5 + 1 = 0x8408, is used in a forward CRC calculation with a preset value of 0x0000.     - 2 -
 TSC-RF013 Module Protocol Manual    II、Function Summary    Flags List Value Function 0x20 General use, with CRC field. 0x68 With CRC field, Tag ID and RF transmitter stays on after the command has been executed.  0x28 With CRC field and RF transmitter stays on after the command has been executed.    Command List Value Name 0x14 SELECT_TAG 0x24 REDA_TAG 0x44 WRITE_TAG    Response Code List  Code Description 0x94 SELECT_TAG fail 0x14 SELECT_TAG pass 0xA4 READ_TAG fail 0x24 READ_TAG pass 0x44 WRITE_TAG pass 0xC4 WRITE_TAG fail                      - 3 -
  TSC-RF013 Module Protocol Manual    III、Description of the Transmission  《》 Select Tag Request : Host → Module [02] [05] [20] [14] [01] [9F 9D] 02 = STX 05 = LENS, 5 Bytes {[20][14][00][9F 9D]} 20 = FLAGS, With CRC field. 14 = COMMAND, SELECT_TAG 01 = Data1, Tag Type = I-Code SLI 9F 9D = CRC, Calculated by the host controller.   Response : Module  Host   Fail : No tag or Wrong tag [02] [03] [94] [F8 C5]   Pass: [02] [0C] [14] [01] [E0 07 00 00 30 03 EC 97] [11 AE] [E0 07 00 00 30 03 EC 97] : Tag UID   《》 Select Tag With Tag UID[E0 07 00 00 30 03 EC 97] Request : Host  Module [02] [0D] [68] [14] [01] [E0 07 00 00 30 03 EC 97] [EA BB]   Response : Module  Host   Fail : No tag or Wrong tag [02] [03] [94] [F8 C5]    Pass:    [02] [03] [14] [7C CD]                 - 4 -
   TSC-RF013 Module Protocol Manual  《》 Read Tag Request : Host  Module [02] [07] [28] [24] [01] [02]#1 [01]#2 [A3 3A] #1 : Starting Block #2 : Number of Blocks   Response : Module  Host   Fail : No tag or Wrong tag [02] [03] [A4] [C9 46]    Pass:    [02] [07] [24] [00 00 00 00] [7C CD] [00 00 00 00] : Block Data                                                  - 5 -
 TSC-RF013 Module Protocol Manual  《》 Write Tag Request : Host  Module [02] [0B] [28] [44] [01] [02]#1 [01]#2 [00 00 00 00]#3 [7A 5B] #1 : Starting Block #2 : Number of Blocks #3 : Write Data   Response : Module  Host   Fail : No tag or Wrong tag [02] [03] [C4] [AA 40]    Pass:    [02] [03] [44] [2E 48]                                                  - 6 -
 CAUTION  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.   Any changes or modifications not expressly approved by the party responsible for compliance could void the authority to operate equipment.   Information for the OEMs and Integrators   The following statement must be included with all versions of this document supplied to an OEM or integrator, but should not be distributed to the end user.        This device is intended for OEM integrators only.    Please See the full Grant of Equipment document for other restrictions.    This device must be operated and used with a locally approved access point.     Information To Be Supplied to the End User by the OEM or Integrator   The following regulatory and safety notices must be published in documentation supplied to the end user of the product or system incorporating an adapter in compliance with local regulations. Host system must be labeled with "Contains VTV2009001", FCC ID displayed on label.