TYCOFETY KANTECH 15KTMULSCKP Smart Card Reader User Manual My
TYCO SAFETY PRODUCTS / KANTECH Smart Card Reader My
Users Manual
SmartCard Reader Mullion Single Gang Technical Specifications Model KT-MUL-MT-KP / KT-MUL-MT Typical Read Range 13.56 MHz MIFARE Plus X, encrypted sector, ID-1 Credentials (Cards) KT-MUL-SC-KP / KT-MUL-SC KT-SG-MT-KP / KT-SG-MT Up to 1.2" Typical Read Range 125 kHz ioProx ID-1 Credentials (Cards) KT-SG-SC-KP / KT-SG-SC Up to 1.6" Up to 1.8" Up to 2.0" Input Voltage 5VDC to 15VDC Power Consumption @ 12V 175mA 70mA 160mA 70mA Operating Humidity 175mA 70mA Operating Temperature 70mA -40C to +70C (-40F to +158F) Environmental Rating IP57 Dimensions (H.W.D.) mm 115.8 x 44.6 x 24.7 Dimensions (H.W.D.) in 4.56 x 1.75 x 0.97 Weight 108g (0.24lb) 106g (0.23lb) 115.8 x 71.5 x 24.7 4.56 x 2.81 x 0.97 105g (0.23lb) 103g (0.23lb) Housing 173g (0.38lb) 166g (0.37lb) 170g (0.37lb) 161g (0.35lb) Polycarbonate, Smoked Black RF Technologies 13.56 MHz and 125 kHz Capacitive Touch Keypad with backlighting 13.56 MHz 13.56 MHz and 125 kHz LED Indicator 13.56 MHz Multi-Color Bar: Red, Green, Yellow, Blue, Configurable Sounder Integrated Tamper Optical Inputs Wiegand or RS-485: LED and Buzzer RS-485: 2 to 4 (configurable, using double device) Output RS-485: 1 supervised, open-drain, up to 750mA Wiring Terminal 6 Screwless Poles Mounting Mullion Communication North American Single Gang RS-485 Bus AES-128 Encrypted or Wiegand Wiegand Formats Supported Credentials 160mA 0 to 95% non-condensing 26-bit / 34-bit / Kantech XSF / Kantech SSF MIFARE Plus X and ISO/IEC 14443A 13.56MHz 125kHz ioProx ioProx Cabling 3 Twisted pairs AWG 22 unshielded, up to 250' (75m) Security Supports AES-128 Encryption between the Credential and the Reader as well as between the Reader and the Access Controller Firmware Fully upgradable via RS-485 Certifications FCC, CE, UL, NIST, FIPS 197, RoHS, WEEE Flammability Rating UL94 V-0 Warranty Limited Lifetime Compatible Access Control Units: Wiegand XSF KT-300, KT-400 and KT-1 Wiegand SSF KT-300, KT-400 and KT-1 RS485 KT-400 and KT-1 SmartCard Reader Mounting Instructions Follow these instructions to install the reader: 1. Pull the controller’s wires in the wall through the hole in the mounting bracket. 2. Affix the mounting plate to the wall using two screws (#6-32). 3. If a higher level of tamper detection is desired, cut the plastic tamper tab from the mounting bracket. 4. Secure the white reflector tab back into the mounting plate hole with a screw. (#6-32). 5. After having wired the reader as per the drawings below, insert the top hook of the cover into the mounting plate tab and complete the procedure by pressing the bottom part into place until the bottom hook is in place. 6. If a more secure installation is desired, install the provided screw at the bottom of the reader. You may also use the provided security screw instead for an even safer installation. (#6-32). Models:KT-MUL-MT and KT-MUL-MT-KP FCC ID: V8515KTMULMTKP IC: 5690B-KTMULMTKP Models: KT-SG-MT and KT-SG-MT-KP FCC ID: V8515KTSGMTKP IC: 5690B-KTSGMTKP Models: KT-MUL-SC and KT-MUL-SC-KP FCC ID: V8515KTMULSCKP IC: 5690B-KTMULSCKP Models: KT-SG-SC and KT-SG-SC-KP FCC ID: V8515KTSGSCKP IC: 5690B-KTSGSCKP FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by KANTECH could void your authority to use this equipment. This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart “B” of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the equipment off and on, the user is encouraged to tr y to correct the interference by one or more of the following measures: -Re-orient the receiving antenna -Relocate the alarm control with respect to the receiver -Move the alarm control away from the receiver -Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCC useful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402, Stock # 004-000-00345-4. INDUSTRY CANADA STATEMENT CAN-ICES-3(B)/NMB-3(B) Wiring Chart via Wiegand Wiring Chart via RS485 Wiring Chart via RS485 (Lock Wiring) UL294 Performance Levels: Destructive Attack: Level I (no attack test) Line Security: Level III (AES128 line security) Endurance: Level IV (100,000 cycles) Standby Power: Level I (no integral standby power) Installation location and wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70. There is no maintenance required and there are no replacement parts required for these devices. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit _____________________________________________________________________________________________________________________ accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. This device complies with Part 15 Class B of the FCC rules. Operation is subject to the following two conditions: (1) Mullion Single Gang FCC ID: V8515KTSGMTKP this device may not cause harmful interference, and (2) this device must accept any interference received including FCC ID: V8515KTMULMTKP IC: 5690B-KTSGMTKP interference that may cause undesired operation. This class B digital apparatus meets all requirements of the Cana- IC: 5690B-KTMULMTKP dian Interference Causing Equipment Regulations CAN ICES-3 (B) / NMB-3 (B). Copyright © 2015 Tyco International Ltd. and its Respective Companies. All rights reserved • Specifications may change without notice Tel.: 1 (450) 444-2030 • Toll Free: 1-888-222-1560 • Fax: 1 (450) 444-2029 • www.kantech.com D29009033R001
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : cfournier Create Date : 2015:10:08 14:30:07-04:00 Modify Date : 2015:12:04 10:38:41-05:00 Subject : Has XFA : No Language : en-us XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2015:12:04 10:38:41-05:00 Format : application/pdf Description : Creator : cfournier Title : My Document Keywords : Producer : madbuild Document ID : uuid:92f1876f-a616-4a1e-8f35-c22c8fe5a11d Instance ID : uuid:6e049b65-f195-4f20-99ab-5c8ec22bd42b Page Mode : UseOutlines Page Count : 2EXIF Metadata provided by EXIF.tools