Tamura TMRF RFID Reader/Writer User Manual

Tamura Corporation RFID Reader/Writer

User Manual

                                   2D-53-00001000                                     TAMURA   CORPORATION  -1/ 16 -          TMRF-1-U001-KM    User’s Manual                               TAMURA   CORPORATION
                                   2D-53-00001000                                     TAMURA   CORPORATION  -2/ 16 -    1.Scope  This document is the user’s manual of Radio Frequency Identification [RFID] Reader /Writer with Universal Serial Bus [USB] for Konica Minolta Business Technologies, Inc.   2.Product Name  TMRF-1-U001-KM  (Product reference code in TAMURA corporation:N-22200066-00)   3.Outlines of product  ・This product is a compact RFID reader / writer with USB interface. ・This product can read and write data for RFID tag by 13.56MHz radio frequency with RFID  wireless interface. ・The USB interface is capable of communicating by low speed [1.5Mbps].
                                   2D-53-00001000                                     TAMURA   CORPORATION  -3/ 16 -  4.Safety Information        Read the following safety information and handling information before using TMRF-1-U001       -KM to avoid injury.    4-1.Important safety information  Failure to follow these safety instructions could result in fire, electric shock, or other injury or damage.  ○DO NOT use this product in hospitals and health care facilities, especially near of sensitive             equipments such as heart pacer to external radio frequency emissions.        ○This product assumes the activity to a general electronic instrument.(AV equipments, OA           equipments, amusement equipments, etc.)           A very advanced reliability is required and the activity to the equipment and units (medical          equipment, an aerospace plane machine, a nuclear equipment, various safety devices, etc.)   with which a trouble and malfunction of a product are directly concerned with a human   life cannot be performed.   Failure to follow these handling instructions could result in damage to TMRF-1-U001-KM or other property.     ○Since this product consists of precision electronic parts, please do not give a strong       impact.           If an impact is given to a product or it is made to fall, it will become a cause of a        crash or a trouble.   ○DO NOT put into a micro wave oven or a high-pressure container.             It becomes a cause of a trouble.  ○DO NOT use TMRF-1-U001-KM in rain or any wet location.  ○Please do not install in an unstable location.         If it is installed in a shaky stand top, a leaning place, etc., it will fall and will become a   cause of a crash or an injury.      ○Please do not pull a moving part and an attachment (especially connector) strongly,   or do not bend them.           They become a cause of a crash or a trouble.  ○Keep this product out of the direct rays of the sun.         It becomes a cause of a trouble.        ○DO NOT use window cleaners, aerosol sprays, solvents, alcohol or abrasion to clean.  ○This product is CMOS product.       Please do not keep it in the place easily charged with electricity.            It becomes a cause of a trouble.  ○When you discard this product, please process as an industrial waste. Warning Caution
                                   2D-53-00001000                                     TAMURA   CORPORATION  -4/ 16 -     4-2 .Operating condition  TAMURA Corporation will grant a nonexclusive license of this product to user on condition of the following.  ○DO NOT perform program analysis, reverse engineering, copy, change, re-distribution, etc.      ○This product is a product approved by Wireless Telegraph Law of each country. You will be punished by violation of Wireless Telegraph Law if a transmitting output is raised       by use of an external antenna, or reconstruction.       ○The specification of this product and the contents of related data may be changed without    a preliminary.       ○This product is based on regulation of the following countries.        Japan , the United States of America , Canada, Australia and New Zealand      When it is in used except the countries which indicated, TAMURA Corporation cannot take  responsibility.  ○This equipment complies with FCC/IC radiation exposure limits set forth for uncontrolled   equipment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement   C to OET65 and RSS-102 of the IC radio frequency (RF) Exposure rules.   This equipment has very low levels of RF energy that it deemed to comply without maximum permissive exposure evaluation (MPE). But it is desirable that it should be installed and operated with at least 20cm and more between the radiator and person’s body (excluding extremities :hands, wrists, feet and ankles).  ○Changes or modifications not expressly approved by the party responsible for compliance could           void the user’s authority to operate the equipment  ○This equipment has been tested and found to comply with the limits for a Class B digital device,   pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection   against harmful interference in a residential installation.   This equipment generates, uses and can radiate radio frequency energy and, if not installed and   used in accordance with the instructions, may cause harmful interference to radio communications.   However, there is no guarantee that interference will not occur in a particular installation.   If this equipment does cause harmful interference to radio or television reception, which can be   determined by turning the equipment off and on, the user is encouraged to try to correct the   interference by one or more of the following measures:   -Reorient or relocate the receiving antenna   -Increase the separation between the equipment and receiver.   -Connect the equipment into an outlet on a circuit different from that to which the receiver is   connected.   -Consult the dealer or an experienced radio/TV technician for help.  ○This device complies with Part 15 of FCC Rules and RSS-Gen of IC Rules.   Operation is subject to the following two conditions : (1) this device may not cause interference,   and (2) this device must accept any interference, including interference that may cause   undesired operation of this device.
                                   2D-53-00001000                                     TAMURA   CORPORATION  -5/ 16 -      4-3. Notes of use     ○DO NOT move adjustment parts of this product.  ○When a metal thing is near this product or this product is covered by a metal thing, the characteristic may deteriorate remarkably.  ○DO NOT insert a USB connector by force (even if it does not put in strong power,   it can insert smoothly). It is NOT connectable unless it inserts at the right direction and the right angle. When you cannot insert, please check direction of a connector once again, without   inserting by force.  ○DO NOT use it in the environment where this product dews.    5.Product structure    RFID R/W with USB [TMRF-1-U001-KM]                           ①USB connector        ②RF CAP (The jack for external antennas) ※Prohibition of use        ③The hole for a strap        ④USB CAP                                            ④ ① ② ③
                                   2D-53-00001000                                     TAMURA   CORPORATION  -6/ 16 -   6.USB Control commands  6-1.USB communications protocol (host    -> RFID R/W -> tag)   Calling    device request bmRequestType = 0x43,0xC3 bRequest       =100+No. (The following table) wValue         = not used wIndex         = not used wLength        = byte count data        = parameter data       1~3  4 ~ n  n+1  n+3 command parameter CRC16 EOT The following table The following table  2bytes  0x04 CRC16  calculation  value   parameter=From command to EOT considers it as 1 text.             No command  function  parameter1 parameter2  parameter3   00  “U00”  ROM Version Read  XX,XX YMD  Nothing      ○01 “U01” Inventory  Nothing      ○02 “U02” Stay Quiet  UID(8)      ○03  “U03”  N Block Read(All data) (Max=9Blocks) UID(8) SBlock#(1) Block count(1) ○04  “U04”  N Block Write(All data)        ×05  “U05”  Read Single Block  UID(8)*1  Block#(1)    ○06  “U06”  Write Single Block  UID(8)*1 Block#(1)  data(4)  ○07 “U07” Lock Block  UID(8)*1 Block#(1)    ○08  “U08”  Read Multi Blocks (Max=9Blocks) UID(8)*1 SBlock#(1) Block count(1) ○09  “U09”  Write Multi Blocks        ×10 “U10” Select Tag  UID(8)      ○11  “U11”  Reset to Ready  UID(8)*1      ○12 “U12” Write AFI  UID(8)*1 AFI(1)    ○13 “U13” Lock AFI  UID(8)*1     ○14 “U14” Write DSFID  UID(8)*1 DSFID(1)    ○15 “U15” Lock DSFID  UID(8)*1     ○16  “U16”  Get System Information  UID(8)*1      ○17  “U17”  Get Multi Block Security Status  UID(8)*1 Sdata(1), data count(1)  ○18  “U18”  Write 2 Blocks  UID(8)*1 Block#(1), 2(1) data1(4), data2(4) ○19  “U19”  Lock 2 Blocks  UID(8)*1  Block#1(1)    ○20 “U20”         ×21 “U21” Special process1(Buzzer  etc) command data    ○22 “U22”         ×    notes:S=start、Block#=01∼64           Block count:Serial line max = 9 /USB max=9           “U03” is the same as “U08”         Special process1(command):0x80= Buzzer function(ON),0x40= Buzzer function(OFF),0x01= Buzzer(ON)      "U18 [Write 2 Blocks]" and "U19 [Lock 2 Blocks]" are Tag-it. It is original command.                     Configuration of UID : There are 2 ways that all 8 bytes are assigned and an implementation-supplier code   is assigned.                     (*1)                  E0 MM XX XX XX XX XX XX -> 00 MM XX XX XX XX XX XX   [MM : an implementation-supplier code assigned = 04(Philips),05(My-D),07(TI)]
                                   2D-53-00001000                                     TAMURA   CORPORATION  -7/ 16 -      No command  function  parameter1 parameter2  parameter3   23 “U23”          24 “U24”          25 “U25”          26 “U26”          27 “U27”          28 “U28”          29 “U29”          30            31 “U31”* Inventory  Nothing       ○32 “U32”* Stay Quiet  UID(8)      ○33  “U33”*  N Block Read(All data) (Max=9Blocks) UID(8)*1 SBlock#(1), Block count(1)  ○34            35  “U35”*  Read Single Block  UID(8)*1  Block#(1)    ○36  “U36”*  Write Single Block UID(8)*1 Block#(1) data(4) ○37 “U37”* Lock Block  UID(8)*1  Block#(1)    ○38  “U38”*  Read Multi Blocks  UID(8)*1 SBlock#(1) Block count(1) ○39            40 “U40”* Select Tag  UID(8)      ○41  “U41”*  Reset to Ready  UID(8)*1      ○42 “U42”* Write AFI  UID(8)*1  AFI(1)    ×43 “U43”* Lock AFI  UID(8)*1      ×44 “U44”* Write DSFID  UID(8)*1  DSFID(1)    ×45 “U45”* Lock DSFID  UID(8)*1      ×46  “U46”*  Get System Information  UID(8)*1      ×47  “U47”*  Get Multi Block Security Status  UID(8)*1 Sdata(1), data count(1)  ×48 “U48”*          49 “U49”*          50           51           52                 ●* is command of a My-D card.           ●My-D assumes 124Page (248Block) with the architecture of 4 bytes/Block now.         ●Since the write-in result of My-D has returned transmission data as it is, read is required for it again.
                                   2D-53-00001000                                     TAMURA   CORPORATION  -8/ 16 -    6-2.    USB communications protocol (tag    -> RFID R/W -> host)   1        2~4                      5~n                 n+1       n+3 ENQ command  parameter  CRC16 EOT 0x05  The following table  The following table  2bytes  0x04  CRC16  calculation   Value      From ENQ to EOT considers it as 1 text          CRC16 : JIS X 6323-3(Part III: Refer to Collision Prevention and Transmission Protocol) ISO/IEC 13239  No command  function  parameter1 parameter2  parameter3   00  “R00”  ROM Version  XX,XX YMD  Version(2)  YY(1),MM(1)  DD(1)  ○01 “R01” Inventory  DSFID(1) UID(8)    ○02 “R02” Stay Quiet  UID(8)      ○03  “R03”  N Block Read(All data) (Max=9Blocks) UID(8)*1 SBlock#(1), Block count(1) The part of the number of9Blocks(45) ○04  “R04”  N Block Write(All data)        ×05  “R05”  Read Single Block  UID(8)*1  Block#(1)  Security(1), data(4) ○06  “R06”  Write Single Block  UID(8)*1 Block#(1)  Dummy(1), data(4) ○07 “R07” Lock Block  UID(8)*1 Block#(1)  Security(1), data(4) ○08  “R08”  Read Multi Blocks (Max=9Blocks) UID(8)*1 SBlock#(1), Block count(1) The part of the number of9Block(45) ○09  “R09”  Write Multi Blocks        ×10 “R10” Select Tag  UID(8)      ○11  “R11”  Reset to Ready  UID(8)*1      ○12 “R12” Write AFI  Flag(1), UID(8)*1 DSFID(1), AFI(1) VICC(2), IC(1) ○13 “R13” Lock AFI  UID(8)*1     ○14 “R14” Write DSFID  Flag(1), UID(8)*1 DSFID(1), AFI(1) VICC(2), IC(1) ○15 “R15” Lock DSFID  UID(8)*1     ○16  “R16”  Get System Information  Flag(1), UID(8)*1 DSFID(1), AFI(1) VICC(2), IC(1) ○17  “R17”  Get Multi Block Security Status  UID(8)*1 Sdata(1), data count(1) The part of the number of32Block(32) ○18  “R18”  Write 2 Blocks  UID(8)*1 Block#(1), 2(1)  ○19  “R19”  Lock 2 Blocks  UID(8)*1  Block#1(1)    ○20  “R99”  Error return  Error flag(1) Error code(1)    ○      notes:S=start、Block#=01∼64             (byte count):The number in a parenthesis                    It is related with an error return and is a reference of error handling.             “R03” is the same as “R08”             The segment which is less than the Block number of "R03", "R08", and "R17" is filled up with 0.             YY=A.D.(2000+YY)                    "R18 [Write 2 Blocks]" and "R19 [Lock 2 Blocks]" are Tag-it. It is original command.
                                   2D-53-00001000                                     TAMURA   CORPORATION  -9/ 16 -      No command  function  parameter1 parameter2  parameter3   21           22           23 “R23”          24 “R24”          25 “R25”          26 “R26”          27 “R27”          28 “R28”          29 “R29”          30            31 “R31”* Inventory  DSFID(1) UID(8)    ○32 “R32”* Stay Quiet  UID(8)      ○33  “R33”*  N Block Read(All data) (Max=9Blocks) UID(8)*1 SBlock#(1), Block count(1) The part of the number of9Blocks(45) ○34            35  “R35”*  Read Single Block  UID(8)*1 Block#(1)  Security(1) data(4) ○36  “R36”*  Write Single Block  UID(8)*1 Block#(1)  Dummy(1), data(4) ○37 “R37”* Lock Block  UID(8)*1 Block#(1)  Security(1), data(4) ○38  “R38”*  Read Multi Blocks (Max=9Blocks) UID(8)*1 SBlock#(1), Block count(1) The part of the number of9Blocks(45) ○39            40 “R40”* Select Tag  UID(8)      ○41  “R41”*  Reset to Ready  UID(8)*1      ○42 “R42”* Write AFI  Flag(1), UID(8)*1 DSFID(1), AFI(1) VICC(2), IC(1) ×43 “R43”* Lock AFI  UID(8)*1      ×44 “R44”* Write DSFID  Flag(1), UID(8)*1 DSFID(1) AFI(1) VICC(2), IC(1) ×45 “R45”* Lock DSFID  UID(8)*1      ×46  “R46”*  Get System Information  Flag(1), UID(8)*1 DSFID(1), AFI(1) VICC(2), IC(1) ×47 “R47”*          48 “R48”*          49 “R49”*          50                 ●* is command of a My-D card.           ●My-D assumes 124Page (248Block) with the architecture of 4 bytes/Block now.         ●Since the write-in result of My-D has returned transmission data as it is, read is required for it again.
                                   2D-53-00001000                                     TAMURA   CORPORATION  -10/ 16 -   6-3.Error handling      It consists of 2bytes of the error flag/error code.       The 1st byte : =0 → It is an error flag on a processing.   The 2nd byte is an error code.      The 1st byte : ≠0 → It is an error flag on a standards.   The 2nd byte is an error code.       receive data 1  2 3 4 5  6  7  8  9 ENQ R 9 9 Error flag Error code CRC16(L) CRC16(H) EOT         flag=0  → code = 1    :    The error under processing of Tag-it → code = 2    :    A processing of Tag-it times out.          flag≠0  →   :  JIS X 6323-3 Refer to (ISO/IEC 15693-3) :  Tag-it HF-I Transponder Inlay                  Extended Commands and Options
                                   2D-53-00001000                                     TAMURA   CORPORATION  -11/ 16 -   7. Attention       (1) After a command transmission, please put "WAIT" and read a response.      (2) Since an error may return depend on PC (personal computer) used, please add a retry  processing.      (3) This product assumes 1 block to be 4 bytes.         my-d corresponds as follows, although 1 block has 8-byte composition.            The 1-4 blocks of my-d cannot be read and written.                       (4)The error flag and error code at the time of setting the parameter which exceeded the         block span by [N Block Read] [Read Multi Block] [Get Multi Block Security Status]         are variable depend on the category of tag and parameter.                      (5) When a command is sent to tag in "Select status", the first byte "E0" in the UID parameter   should be changed to "10"
                                   2D-53-00001000                                     TAMURA   CORPORATION  -12/ 16 -        (6) Any error code is not returned if it performs the [Write AFI] processing to the I-CODE2   tag AFI locked.            (7) Any error code is not returned if it performs the [Lock AFI] processing to the I-CODE2  tag AFI locked.      (8) Any error code is not returned if it performs the [Write DSFID ] processing to the I-CODE2   tag DSFID locked.      (9) Any error code is not returned if it performs the [Lock    DSFID ] processing to the I-CODE2   tag DSFID locked.      (10) When you perform "Read" and "Write", without setting up UID in particular, please         perform a single byte set of an implementation-supplier code.      (11) An error occurs when 29 or more blocks are set to I-CODE2 with single byte setting as an   implementation-supplier code.      (12) This product performs with to the following tag or the tag in which IC was used.         TAG-IT HFI                    [TEXAS INSTRUMENTS]        I-CODE2       SL2  ICS20  [PHILIPS] my-d           SRF  55V10P   [Infineon Technologies]
                                   2D-53-00001000                                     TAMURA   CORPORATION  -13/ 16 -  8. Product specification     8-1.Interface specification  (1)USB interface  (1-1)Connector          (1-2) Standard                        USB1.1 Low Speed         (2)External antenna interface             The miniaturized antenna is built in this product.             It is prohibition to connect an external antenna.     8-2.Mechanical specification                                            Weight : 20g or less   Pin No. function Signal 1 Vbus +5V 2 D- Serial data(-) 3 D+ Serial data(+) 4 GND GND ①④
                                   2D-53-00001000                                     TAMURA   CORPORATION  -14/ 16 -      8-3.General specification  Radio Frequency   : 13.56MHz  Correspondence standard : ISO15693  Voltage of operation   : +4.75V ~ +5.25V  Consumption current  : 100mA or less  LED(green)    : Power-up lighting  LED(red)    : Blink at the time of a datacomm with a tag.  Operating temperature  : 0°C~+40°C (+32°F~+104°F)  Operating humidity  : 20~80%RH (non-condensation)  Storage temperature  : -20°C~60°C (-4°F~+140°F)  Storage humidity   : 10~90%RH (non-condensation)
                                   2D-53-00001000                                     TAMURA   CORPORATION  -15/ 16 -    9.Guarantee     【About guarantee】       This guarantee promises a gratis repair, when the product I was allowed to supply should be        broken down by the normal activity according to this product specification.    【Term of a guarantee】       Three months after the delivery.    【Inapplicable guarantee】                  Even if it is within the term of a guarantee, when it corresponds to the following list item,                 it becomes inapplicable gratis repair .      (1) The damage or the trouble by the handling from which it deviated by the written content      of the " attention ."      (2) Damage by the natural disaster of a thunderbolt, a Fire, storm and flood damages,       an earthquake, and others and pollution, damage from salt water, a static electricity, etc.      (3) The trouble resulting from other connected units and other external factors.      (4) Externally caused injury of the main frame after a Delivery.      (5) When an event is NOT reproduced at TAMURA Corporation.   【Other attention】  (1) When the damage which is contrary to the "attention" written content of this product, and originates in a user's intentionally and negligence occurs, TAMURA Corporation   DOES NOT take the responsibility.  (2) When the damage concerning direct and the indirect target resulting from an activity of this product occurs, the responsibility is NOT taken except for the case where there is negligence in which TAMURA Corporation is serious.  (3) Guarantee is effective only in an application country.
                                   2D-53-00001000                                     TAMURA   CORPORATION  -16/ 16 -   10.Model specification     10-1.Specification number (Japan)          The model specification of TMRF-1-U001-KM is as follows.         10-2. Wireless Telegraph Law             Since the following acts serve as a fault of Wireless Telegraph Law, please do not         perform them by any means.              (1) Use an external antenna.            (2) Convert this product.   11. Reference     Tamura Corporation    Broadcom B.U.      1-19-43, Higashi-Oizumi, Nerima-ku, Tokyo, 178-8511 Japan    URL:http://www.tamura-ss.co.jp          Model name Attestation numberTM-RFRW-U001 AC-04097