TandD RTR50X Wireless Thermo Recorder User Manual RTR 05B1 indd

TandD Corporation Wireless Thermo Recorder RTR 05B1 indd

Contents

Additional Users Manula 2

Download: TandD RTR50X Wireless Thermo Recorder User Manual RTR 05B1 indd
Mirror Download [FCC.gov]TandD RTR50X Wireless Thermo Recorder User Manual RTR 05B1 indd
Document ID1144082
Application IDo2w4urPJTyBxfSxOSPzK5w==
Document DescriptionAdditional Users Manula 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize29.27kB (365896 bits)
Date Submitted2009-07-24 00:00:00
Date Available2009-07-25 00:00:00
Creation Date2005-04-21 13:07:20
Producing SoftwareAdobe PDF Library 6.0
Document Lastmod2009-06-19 09:41:35
Document TitleRTR_05B1.indd
Document CreatorAdobe InDesign CS_J (3.0)

About this Product
This product is a Large Capacity Battery Pack especially designed for use with our
RTR-500x Series data loggers.
Caution: If this product is used in combination with any product other than those
specified above, T&D Corporation shall in no manner, whatsoever,
guarantee the operation of this product.
Package Contents
The package contains the following:
RTR-500B1
Large Capacity Battery Pack
Large Capacity Battery Pack
Rubber Packing
Attachment hook
Drying agent
(Silica Gel)
Double-sided
Adhesive Tape × 1
(for fastening silica gel)
Screw ×2
(extras for fastening back of
main unit)
Specifications
Power
Battery Life
Shimadachi 817-1, Matsumoto, Nagano 390-0852 Japan
Tel:+81-263-40-0131 Fax:+81-263-40-3152
E-mail: support@tandd.com
Homepage: http://www.tandd.com/
2009.04 16004244230 3rd Edition
: Lithium Battery ×1(LS26500)
: about 2 years and 6 months
(Monitoring at 1 minute interval=about 20
months ※ 1)
Waterproof Capability : Splash proof
Weight
: about 75g (including lithium battery)
Operating Temperature: -40-80℃※ 2
Note:
※ 1:Battery Life varies depending on measuring environment,
recording interval, transmission frequency, and ambient
temperature. The battery life estimated here is calculated using
a new battery under normal operating conditions and in no way
should be understood as a guarantee of battery life.
※ 2:Operating temperature depends on the specifications for the data
logger being used.
How to Attach
Caution: If you do not wish to lose the recorded data, please finish this operation
in less than 1 minute from the time that you remove the battery from the
RTR-500x Series unit. (We suggest that you download recorded data
before attaching the adaptor. For details about downloading data, see
the User’s Manual that comes with the software you are using or the
Base Unit being used for our Thermo Recorder RTR-500x Series Data
Loggers.)
5. Making sure that the 2 electrical wires are in the grooves as in
diagram A (below left), insert A (as in right diagram) into the battery
space of the RTR-500x Series unit. Close the case and fasten the
screws.
1. Remove the back lid from the RTR-500x Series unit, open the unit
and take out the battery.
2. Attach the double-sided adhesive tape to the back of the drying agent
and fix to the inner side of the RTR-500B1.
3. Insert the accompanying lithium battery into the battery pack.
4.Check the RTR-500B1 rubber packing for abrasions, cuts and dirt. If
the packing is in good condition, insert into the grooves making sure
that it is properly fit.
Caution:
●
●
Abrasions or dirt may cause small opening to occur through which water
or other foreign objects can enter and cause damage to the unit.
The rubber packing is a special item and is not sold in stores. If it
becomes damaged, please replace it by ordering [Maintenance Set](TR00P1) or by ordering a new [Large Capacity Battery Pack Battery Set]
(RTR-500B2).
Caution: If the electrical wires are not properly in their grooves, the lid
may not completely close. Please make sure that the wires are
in their grooves before continuing.
If no recording settings have been made before carrying out this
operation, recording will begin from the time section A is inserted into
the battery space.
※ If, after inserting section A, nothing appears in the unit's LCD display,
please repeat the steps above and attach again, For details about the
display, see the appropriate user's manual for the RTR-500x Series
unit.
6. If necessary, put on the attachment hook.
◆ Notices about this User's Manual
● Please
read this manual carefully before using the product.
rights of this User's Manual belong to T&D Corporation. It is prohibited to
use, duplicate and/or arrange a part or whole of this User's Manual without
the permission of T&D Corporation.
● Please follow the safety precautions carefully. We cannot guarantee nor are
we responsible for safety if this product is used in any manner other than was
intended.
● T&D Corporation accepts no responsibility for any malfunction of and /or
trouble with this product or with your computer that is caused by the improper
handling of this product and will deem such trouble or malfunction as falling
outside the conditions for free repair of the attached warranty.
● T&D Corporation accepts no responsibility for any result or effects from using
this User's Manual.
● All
◆ Notices about this User's Manual
● Figures
and illustrations in this manual may be slightly simplified and may
differ from the actual product.
● On screen messages, figures or illustrations in this manual may vary slightly
or be simplified from the actual messages and product.
● We
sincerely hope that the contents of this manual are true and complete. If
you find any information to have been omitted, or if the information within is
confusing or mistaken please, contact your retailer or T&D Corporation.
®
®
®
● Microsoft , Windows and WindowsNT are registered trademarks of
Microsoft Corporation USA and are binding in the USA and all other
countries. Company names and product names are trademarks or registered
trademarks of each company.
● This User's Manual cannot be reissued, so please keep it in a safe place.
● Please carefully read this User's Manual and Free Repair Warranty.
※ Please carefully observe the following safety measures when using our product.
To prevent any loss or damage to our customers, other people and / or property, and to ensure the proper use of our products we ask that before using our product you
carefully read, understand and follow the safety rules and precautions for our products as outlined below.
Explanation of Picture Symbols]
[Explanation of Warning Symbols]
These entries are actions that absolutely under no
DANGER circumstance should be taken. The taking of such an action
may cause serious personal physical damage or death.
These entries are actions that if taken may lead to physical
CAUTION
injury or damage to persons or things.
This symbol denotes an important warning or caution. Inside or
near the symbol will appear another symbol giving details.
stands for FIRE OR ELECTROCUTION)
(EX:
This symbol denotes a forbidden action. Inside or near the symbol
will appear another symbol giving details.
(EX:
stands for DO NOT TAKE APART)
This symbol denotes an action that you must take. Inside or near
the symbol will appear another symbol giving details.
DANGER
Do not take apart, repair or modify the main unit.
If water or a foreign object enters the case, immediately cease using it.
It may cause fire, electrocution or damage. Ask the shop where
you purchased the product or T&D Corporation to carry out any
repairs.
Store all batteries, sensors and Thermo Recorder units out of the reach
of children. It is dangerous to swallow batteries.
If any smoke or strange smells are emitted from the unit, immediately
cease using it.
Please be careful when using the units in overly hot or cold
environments; touching the units may cause burns or frostbite.
Continued use may cause fire, electrocution or damage.
Do not use any batteries other than those that are recommended. It
may cause fire or damage.
CAUTION
T&D is not responsible for any malfunction or trouble caused by the use
of our product or any problem caused by the malfunction of our unit.
Please be fully aware of this before using our product.
This product has been designed for private or industrial use only.
It is not for use in situations where strict safety precautions are
necessary such as in connection with medical equipment whether
directly or indirectly.
Do not drop or expose the unit to strong impact.
Battery terminals may provide insufficient contact due to age or
vibration. Please be careful not to lose data due to insufficient contact.
Battery life depends on the measurement environment, communication
frequency, recording interval and battery quality.
Pay attention to water leakage or foreign objects entering into the unit
case as in the following cases.
● The case was closed with dust, hair, etc., on the rubber packing or
in the groove for the packing.
● The rubber packing becomes damaged. (In this case, please
purchase the optional maintenance set.)
Remove batteries from any unit that is not to be used for a long period
of time. Batteries left in a unit not being used for a long time may leak
and cause a malfunction.
Do not use or store the unit in places such as listed below:
It may cause electrocution, fire or damage to the unit or to your
computer.
● Areas
exposed to direct sunlight.
exposed to water or high-pressure water flow.
● Areas exposed to organic solvents and corrosive gas.
● Areas exposed to strong magnetic fields.
● Areas exposed to static electricity.
● Areas exposed to fire or overheating.
● Areas exposed to excessive dust or smoke.
● Areas

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:5a6041be-5885-4f75-8543-413a1db7c5bb
Create Date                     : 2005:04:21 13:07:20Z
Modify Date                     : 2009:06:19 09:41:35+09:00
Metadata Date                   : 2009:06:19 09:41:35+09:00
Creator Tool                    : Adobe InDesign CS_J (3.0)
Version ID                      : 1
Rendition Class                 : proof:pdf
Document ID                     : adobe:docid:indd:f3f83bb5-b20b-11d9-8366-9861856b9e20
Manifest Link Form              : ReferenceStream, ReferenceStream
Manifest Reference Instance ID  : uuid:5cc98719-3412-40b2-b9d8-7d09fb48b3c9, uuid:4ebeb6b8-5370-4932-8c87-ecfa08a27f58
Manifest Reference Document ID  : uuid:61b3d0e0-4640-43bb-90fa-b732cd19f40f, uuid:03e8eabe-d9e5-4c91-9fcd-f0a960e6eaaf
Format                          : application/pdf
Title                           : RTR_05B1.indd
Trapped                         : False
Creator                         : Adobe InDesign CS_J (3.0)
Producer                        : Adobe PDF Library 6.0
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SRDRTR50X

Navigation menu